164 resultados para flicker


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the relative contributions of rods, cones and melanopsin to pupil responses in humans using temporal sinusoidal stimulation for light levels spanning the low mesopic to photopic range. Methods: A four-primary Ganzfeld photostimulator controlled flicker stimulations at seven light levels (-2.7 to 2 log cd/m2) and five frequencies (0.5 to 8Hz). Pupil diameter was measured using a high-resolution eyetracker. Three kinds of sinusoidal photoreceptor modulations were generated using silent substitution: 1) rod modulation, 2) cone modulation, and 3) combined rod and cone modulation in phase (Experiment 1) or phase shifted (Experiment 2) from a fixed rod phase. The melanopsin excitation was computed for each condition. A vector sum model was used to estimate the relative contribution of rods, cones and melanopsin to the pupil response. Results: From Experiment 1, the pupil frequency response peaked at 1Hz at two mesopic light levels for the three modulation conditions. Analyzing the rod-cone phase difference for the combined modulations (Experiment 2) identified a V-shaped response amplitude with a minimum between 135° and 180°. The pupil response phases increased as cone modulation phase increased. The pupil amplitude increased with increasing light level for cone and combined in-phase rod and cone modulation, but not for the rod modulation. Conclusions: These results demonstrate that cone- and rod-pathway contributions are more predominant than melanopsin contribution to the phasic pupil response. The combined rod, cone and melanopsin inputs to the phasic state of the pupil light reflex follow linear summation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The experimental portion of this thesis tries to estimate the density of the power spectrum of very low frequency semiconductor noise, from 10-6.3 cps to 1. cps with a greater accuracy than that achieved in previous similar attempts: it is concluded that the spectrum is 1/fα with α approximately 1.3 over most of the frequency range, but appearing to have a value of about 1 in the lowest decade. The noise sources are, among others, the first stage circuits of a grounded input silicon epitaxial operational amplifier. This thesis also investigates a peculiar form of stationarity which seems to distinguish flicker noise from other semiconductor noise.

In order to decrease by an order of magnitude the pernicious effects of temperature drifts, semiconductor "aging", and possible mechanical failures associated with prolonged periods of data taking, 10 independent noise sources were time-multiplexed and their spectral estimates were subsequently averaged. If the sources have similar spectra, it is demonstrated that this reduces the necessary data-taking time by a factor of 10 for a given accuracy.

In view of the measured high temperature sensitivity of the noise sources, it was necessary to combine the passive attenuation of a special-material container with active control. The noise sources were placed in a copper-epoxy container of high heat capacity and medium heat conductivity, and that container was immersed in a temperature controlled circulating ethylene-glycol bath.

Other spectra of interest, estimated from data taken concurrently with the semiconductor noise data were the spectra of the bath's controlled temperature, the semiconductor surface temperature, and the power supply voltage amplitude fluctuations. A brief description of the equipment constructed to obtain the aforementioned data is included.

The analytical portion of this work is concerned with the following questions: what is the best final spectral density estimate given 10 statistically independent ones of varying quality and magnitude? How can the Blackman and Tukey algorithm which is used for spectral estimation in this work be improved upon? How can non-equidistant sampling reduce data processing cost? Should one try to remove common trands shared by supposedly statistically independent noise sources and, if so, what are the mathematical difficulties involved? What is a physically plausible mathematical model that can account for flicker noise and what are the mathematical implications on its statistical properties? Finally, the variance of the spectral estimate obtained through the Blackman/Tukey algorithm is analyzed in greater detail; the variance is shown to diverge for α ≥ 1 in an assumed power spectrum of k/|f|α, unless the assumed spectrum is "truncated".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report experiments on hot-electron stressing in commercial III-V nitride based heterojunction fight-emitting diodes. Stressing currents ranging from 100 mA to 200 mA were used. Degradations in the device properties were investigated through detailed studies of the I-V characteristics, electroluminescence, Deep-Level Transient Fourier Spectroscopy and flicker noise. Our experimental data demonstrated significant distortions in the I-V characteristics. The room temperature electroluminescence of the devices exhibited 25% decrement in the peak emission intensity. Concentration of the deep-levels was examined by measuring the Deep-Level Transient Fourier Spectroscopy, which indicated an increase in the density of deep-traps from 2.7 x 10(13) cm(-3) to 4.21 x 10(13) cm(-3) at E-1 = E-C - 1.1eV. The result is consistent with our study of 1/f noise, which exhibited up to three orders of magnitude increase in the voltage noise power spectra. Our experiments show large increase in both the interface traps and deep-levels resulted from hot-carrier stressing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate whether two methods of measuring macular pigment-namely, heterochromatic flicker photometry (HFP) and resonance Raman spectroscopy (RRS)--yield comparable data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The OSCAR test, a clinical device that uses counterphase flicker photometry, is believed to be sensitive to the relative numbers of long-wavelength and middle-wavelength cones in the retina, as well as to individual variations in the spectral positions of the photopigments. As part of a population study of individual variations in perception, we obtained OSCAR settings from 1058 participants. We report the distribution characteristics for this cohort. A randomly selected subset of participants was tested twice at an interval of at least one week: the test-retest reliability (Spearman's rho) was 0.80. In a whole-genome association analysis we found a provisional association with a single nucleotide polymorphism (rs16844995). This marker is close to the gene RXRG, which encodes a nuclear receptor, retinoid X receptor γ. This nuclear receptor is already known to have a role in the differentiation of cones during the development of the eye, and we suggest that polymorphisms in or close to RXRG influence the relative probability with which long-wave and middle-wave opsin genes are expressed in human cones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A common problem in video surveys in very shallow waters is the presence of strong light fluctuations, due to sun light refraction. Refracted sunlight casts fast moving patterns, which can significantly degrade the quality of the acquired data. Motivated by the growing need to improve the quality of shallow water imagery, we propose a method to remove sunlight patterns in video sequences. The method exploits the fact that video sequences allow several observations of the same area of the sea floor, over time. It is based on computing the image difference between a given reference frame and the temporal median of a registered set of neighboring images. A key observation is that this difference will have two components with separable spectral content. One is related to the illumination field (lower spatial frequencies) and the other to the registration error (higher frequencies). The illumination field, recovered by lowpass filtering, is used to correct the reference image. In addition to removing the sunflickering patterns, an important advantage of the approach is the ability to preserve the sharpness in corrected image, even in the presence of registration inaccuracies. The effectiveness of the method is illustrated in image sets acquired under strong camera motion containing non-rigid benthic structures. The results testify the good performance and generality of the approach

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The visual systems of birds are hypothesized to have higher temporal resolution than those of humans, suggesting that they may be able to perceive the flicker emitted from conventional low-frequency fluorescent lights (LF; 100 Hz in Europe, 120 Hz in the U.S.A.). These lights are commonly used in the housing of captive birds and this may affect both their welfare and performance in experiments. We carried out mate choice experiments on European starlings, Sturnus vulgaris, under both low- and high-frequency fluorescent lights (HF; > 30 kHz, at which flicker is imperceptible). Indicators of male condition and size, together with the reflectance spectra and length of the males' throat feathers, were also recorded to ascertain which variables correlated with female preference. Females ranked males consistently under HF, but not LF, lighting, and individual females chose different males under the two lighting types. Under HF lighting, females chose to spend more time with males that had longer throat feathers. The flicker rate of the light clearly affected the choices made by the females, possibly because of nonspecific stress effects or decreased discrimination ability. Our results imply that careful interpretation of mate choice experiments is needed, especially with regard to the lighting types used, to elucidate the real cause behind any variation shown. (c) 2006 The Association for the Study of Animal Behaviour. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is common practice for captive birds to be kept under fluorescent lighting, which typically flickers at either 100Hz (UK) or 120 Hz (USA). Such lighting was developed for human vision and it is thought that birds may be able to detect higher frequencies of flicker than humans. For humans, 100Hz fluorescent lighting has been linked to eyestrain, headaches and migraine, even though this rate of flicker is above the human perceptual flicker-fusion frequency of around 60 Hz. Keeping birds under 100 Hz lighting is therefore potentially detrimental to their welfare. We studied the preferences of wild-caught European starlings, Sturnus vulgaris, for high-frequency (HF, >30 kHz) fluorescent lighting versus conventional low-frequency (LF, 100 Hz) fluorescent lighting. The flicker frequency of the HF lighting would be undetectable to the nervous system of any animal. We also exposed starlings to either HF or LF light for 2 weeks, and investigated the degree of stress caused by each environment by monitoring their behaviour and plasma corticosterone levels. Groups of starlings showed a preference for HF lighting over LF lighting (P < 0.001), which indicates that they can detect a difference between the two lighting conditions and find the HF lighting preferable. However, there were no measurable differences in behaviour or plasma corticosterone levels when the birds were housed under either HF or LF for 2 weeks, thus providing initial evidence that housing starlings under 100Hz lighting may not be detrimental to the welfare of starlings during early captivity. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To measure heterochromatic flicker electroretinograms (ERGs) at high (36 Hz) and intermediate (12 Hz) temporal frequencies to evaluate luminance and cone opponent responses, respectively, in glaucoma eyes with (perimetric) and without (preperimetric) visual field defects. METHODS. Flicker ERGs were recorded from one randomly chosen dilated eye of 32 patients (mean age, 61 +/- 11 years; 15 men, 17 women) from the Erlangen Glaucoma Registry and from 24 healthy volunteers (mean age, 43 +/- 11 years; 14 men, 10 women). Red and green light-emitting diodes in a Ganzfeld stimulator were sine wave-modulated in counterphase. The responses were measured at 36 Hz, the frequency at which ERGs reflect activity of the luminance pathway, and at 12 Hz, the frequency at which ERGs reflect chromatic activity. RESULTS. Response amplitudes were similar in glaucoma patients and controls. Phase differences were observed in patients with visual field defects (perimetric) compared with the control group at 36 and 12 Hz in the first harmonic and second harmonic responses. Patients without visual field defects (preperimetric) showed phase differences for the second harmonic component at 36 Hz. No age effect on response amplitudes and phases was found in any of the subject groups (controls and patients). CONCLUSIONS. The responses displayed phase differences but not amplitude differences in perimetric glaucoma patients at both 36 and 12 Hz, suggesting that both magnocellular and parvocellular pathways are affected. Preperimetric glaucoma patients also showed phase differences. The response phase may be sensitive to early dysfunction of the inner retina. (ClinicalTrials.gov number, NCT00494923.) (Invest Ophthalmol Vis Sci. 2011;52:6757-6765) DOI:10.1167/iovs.11-7538

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to investigate whether there is an ocular interaction in the flicker ERG responses reflecting luminance and cone opponency in normal human subjects. Flicker ERGs were recorded from one dilated eye of 10 healthy volunteers. Each subject was tested twice: once with and once without occluding the opposite eye. Red and green LEDs were modulated in counterphase in a Ganzfeld stimulator. ERG responses were recorded for different ratios of the modulation in the red and green LEDs and at 12 and 36 Hz. The amplitudes and phases of the fundamental components were compared between the conditions with and without occlusion. The 12-Hz flicker ERGs reflected activity of the cone opponent channel, whereas the 36-Hz data reflected luminance activity. There were no significant differences between the conditions with and without occluding the opposite eye for any of the stimulus protocols. Ocular interaction is absent in flicker ERGs reflecting cone opponent and luminance activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To refine methods of electroretinographical (ERG) recording for the analysis of low retinal potentials under scotopic conditions in advanced retinal degenerative diseases. Standard Ganzfeld ERG equipment (Diagnosys LLC, Cambridge, UK) was used in 27 healthy volunteers (mean age 28 +/- A SD 8.5 years) to define the stimulation protocol. The protocol was then applied in clinical routine and 992 recordings were obtained from patients (mean age 40.6 +/- A 18.3 years) over a period of 5 years. A blue stimulus with a flicker frequency of 9 Hz was specified under scotopic conditions to preferentially record rod-driven responses. A range of stimulus strengths (0.0000012-6.32 scot. cd s/mA(2) and 6-14 ms flash duration) was tested for maximal amplitudes and interference between rods and cones. Analysis of results was done by standard Fourier Transformation and assessment of signal-to-noise ratio. Optimized stimulus parameters were found to be a time-integrated luminance of 0.012 scot. cd s/mA(2) using a blue (470 nm) flash of 10 ms duration at a repetition frequency of 9 Hz. Characteristic stimulus strength versus amplitude curves and tests with stimuli of red or green wavelength suggest a predominant rod-system response. The 9 Hz response was found statistically distinguishable from noise in 38% of patients with otherwise non-recordable rod responses according to International Society for Clinical Electrophysiology of Vision standards. Thus, we believe this protocol can be used to record ERG potentials in patients with advanced retinal diseases and in the evaluation of potential treatments for these patients. The ease of implementation in clinical routine and of statistical evaluation providing an observer-independent evaluation may further facilitate its employment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flicker is a power quality phenomenon that applies to cycle instability of light intensity resulting from supply voltage fluctuation, which, in turn can be caused by disturbances introduced during power generation, transmission or distribution. The standard EN 61000-4-15 which has been recently adopted also by the IEEE as IEEE Standard 1453 relies on the analysis of the supply voltage which is processed according to a suitable model of the lamp – human eye – brain chain. As for the lamp, an incandescent 60 W, 230 V, 50 Hz source is assumed. As far as the human eye – brain model is concerned, it is represented by the so-called flicker curve. Such a curve was determined several years ago by statistically analyzing the results of tests where people were subjected to flicker with different combinations of magnitude and frequency. The limitations of this standard approach to flicker evaluation are essentially two. First, the provided index of annoyance Pst can be related to an actual tiredness of the human visual system only if such an incandescent lamp is used. Moreover, the implemented response to flicker is “subjective” given that it relies on the people answers about their feelings. In the last 15 years, many scientific contributions have tackled these issues by investigating the possibility to develop a novel model of the eye-brain response to flicker and overcome the strict dependence of the standard on the kind of the light source. In this light of fact, this thesis is aimed at presenting an important contribution for a new Flickermeter. An improved visual system model using a physiological parameter that is the mean value of the pupil diameter, has been presented, thus allowing to get a more “objective” representation of the response to flicker. The system used to both generate flicker and measure the pupil diameter has been illustrated along with all the results of several experiments performed on the volunteers. The intent has been to demonstrate that the measurement of that geometrical parameter can give reliable information about the feeling of the human visual system to light flicker.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'attività di tesi consiste sia nella calibrazione di un banco di misura per analisi di rumore a basse frequenze nei dispositivi MOSFET di potenza, sia nella valutazione dei relativi e successivi dati sperimentali (con particolare attenzione anche ai processi di stress e recupero applicati ai dispositivi).