Development of human visual system analysis for the implementation of a new instrument for flicker measurement


Autoria(s): Masi, Maria Gabriella
Contribuinte(s)

Peretto, Lorenzo

Data(s)

07/04/2011

Resumo

Flicker is a power quality phenomenon that applies to cycle instability of light intensity resulting from supply voltage fluctuation, which, in turn can be caused by disturbances introduced during power generation, transmission or distribution. The standard EN 61000-4-15 which has been recently adopted also by the IEEE as IEEE Standard 1453 relies on the analysis of the supply voltage which is processed according to a suitable model of the lamp – human eye – brain chain. As for the lamp, an incandescent 60 W, 230 V, 50 Hz source is assumed. As far as the human eye – brain model is concerned, it is represented by the so-called flicker curve. Such a curve was determined several years ago by statistically analyzing the results of tests where people were subjected to flicker with different combinations of magnitude and frequency. The limitations of this standard approach to flicker evaluation are essentially two. First, the provided index of annoyance Pst can be related to an actual tiredness of the human visual system only if such an incandescent lamp is used. Moreover, the implemented response to flicker is “subjective” given that it relies on the people answers about their feelings. In the last 15 years, many scientific contributions have tackled these issues by investigating the possibility to develop a novel model of the eye-brain response to flicker and overcome the strict dependence of the standard on the kind of the light source. In this light of fact, this thesis is aimed at presenting an important contribution for a new Flickermeter. An improved visual system model using a physiological parameter that is the mean value of the pupil diameter, has been presented, thus allowing to get a more “objective” representation of the response to flicker. The system used to both generate flicker and measure the pupil diameter has been illustrated along with all the results of several experiments performed on the volunteers. The intent has been to demonstrate that the measurement of that geometrical parameter can give reliable information about the feeling of the human visual system to light flicker.

Formato

application/pdf

Identificador

http://amsdottorato.unibo.it/3270/1/Masi_Maria_Gabriella_tesi.pdf

urn:nbn:it:unibo-2371

Masi, Maria Gabriella (2011) Development of human visual system analysis for the implementation of a new instrument for flicker measurement, [Dissertation thesis], Alma Mater Studiorum Università di Bologna. Dottorato di ricerca in Ingegneria elettrotecnica <http://amsdottorato.unibo.it/view/dottorati/DOT261/>, 23 Ciclo. DOI 10.6092/unibo/amsdottorato/3270.

Idioma(s)

en

Publicador

Alma Mater Studiorum - Università di Bologna

Relação

http://amsdottorato.unibo.it/3270/

Direitos

info:eu-repo/semantics/openAccess

Palavras-Chave #ING-INF/07 Misure elettriche e elettroniche
Tipo

Tesi di dottorato

NonPeerReviewed