1000 resultados para fixture design
Influence of abutment-to-fixture design on reliability and failure mode of all-ceramic crown systems
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
When machining a large-scale aerospace part, the part is normally located and clamped firmly until a set of features are machined. When the part is released, its size and shape may deform beyond the tolerance limits due to stress release. This paper presents the design of a new fixing method and flexible fixtures that would automatically respond to workpiece deformation during machining. Deformation is inspected and monitored on-line, and part location and orientation can be adjusted timely to ensure follow-up operations are carried out under low stress and with respect to the related datum defined in the design models.
Resumo:
In this paper, manufacturability analysis and collection of design aspects is made for a microwave test-fixture. Aspects of applying systematic design for a microwave test-fixture design and manufacturing are also analysed. Special questionnaires for the component and machining are made in order to enable necessary information to ensure DFM(A) – aspects of the component. The aspects of easy manufacturing for machining the microwave test-fixture are collected. Material selection is discussed and manufacturing stages of prototype manufacturing are presented.
Resumo:
Tällä hetkellä hitsauksen automatisointiaste on hyvin pieni alumiinivenevalmistuksessa. Automatisointiasteen kasvattaminen on ensiarvoisen tärkeää kilpailukyvyn säilyttämiseksi, sekä edelleen nostamiseksi. Automatisointiasteen kasvattamisen esteenä ei ole teknologian puute, vaan suunnitellut tuotteet soveltuvat huonosti robotisoituun hitsaukseen. Lisäksi liitettävien osien tarkkuus on monissa tapauksissa puutteellinen, joten robottihitsaus on monessa tapauksessa mahdotonta. Robottihitsauksessa vaaditaan osien hyvää paikoittamista ja siihen tarvitaan kiinnittimiä. Kuitenkin alumiinivenevalmistuksessa valmistusmäärät ovat sen verran pieniä, että tuotekohtaisia kiinnittimiä ei kannata hankkia tai valmistaa. Siksi kiinnittimiltä vaaditaan joustavuutta ja modulaarisuutta, jotta samalla kiinnittimellä voi hitsata useita vastaavia piirteitä omaavia tuotteita. Tässä työssä tutkittiin modulaarisia kiinnittimiä, edistyneitä kiinnitinsuunnitteluprosesseja, osavalmistustarkkuuksia, tuotemoduloinnin hyödyntämistä ja alumiinin robottihitsauksen erityispiirteitä. Työssä suunniteltiin ja simuloitiin modulaarinen hitsauskiinnitin, jota käytetään tietyn alumiinivenemallin erillisenä osakokoonpanona valmistettavan jäykisterakennekonseptin hitsaamiseen. Suunnittelu ja simulointi tehtiin Delmia V5R20 -ohjelmistolla. Jäykisterakenne on modulaarinen tuoterakenne, jossa käytetään itsepaikoittavia liitoksia helpottamaan osien asettelua ja yksinkertaistamaan kiinnitintä. Kiinnitin soveltuu joustavasti erikokoisten jäykisterakenneosakokoonpanojen valmistukseen. Lisäksi suunniteltua kiinnitintä verrattiin kaupalliseen modulaariseen Demmeler -kiinnitinjärjestelmään. Jäykisterakenteen osakokoonpanon hitsaaminen robotilla lyhentää valmistusaikaa verrattuna nykytilaan, kun osat voidaan asettaa kiinnittimeen nopeasti ja luotettavasti. Samalla jäykisterakenteen tekeminen erillisenä osakokoonpanona lyhentää veneen rungon loppukokoonpanoaikaa ja mahdollistaa hitsausrobotin käytön myös veneen muiden hitsien hitsaamisessa. Modulaarisilla hitsauskiinnittimillä saavutetaan alumiiniveneiden nykyisillä valmistusmäärillä skaalaetuja, joita tuotekohtaisella kiinnittimellä ei voi saavuttaa.
Resumo:
Tämän diplomityön tarkoituksena oli kehittää robottihitsauksen toimintoja KKR Steel Oy:ssä. Tärkeimmät tutkimuskohteet olivat robottisolujen toiminnan tehostaminen ja uusien robottihitsaukseen sopivien tuotteiden kartoittaminen. Työ on jaettu teoreettiseen ja käytännön osuuteen. Teoriaosassa perehdytään kirjallisuuskatsauksen kautta robottihitsauksen perusteisiin, hitsauksen robotisointiin sekä tuottavuuteen ja laatuun. Robottihitsauksen osuudessa käsitellään hitsausrobotin rakennetta, siihen liittyviä oheislaitteita ja robottien ohjelmointia. Hitsauksen robotisoinnissa selvitetään syitä robottihitsauksen käyttöönotolle, robotisoitavilta tuotteilta vaadittavia ominaisuuksia sekä erilaisia toimenpiteitä robottiaseman toiminnan tehostamiseksi. Tuottavuuteen liittyvässä osuudessa selvitetään erilaisten laskentakaavojen ja tunnuslukujen käyttöä ja merkitystä hitsauksessa. Käytännön osuudessa kartoitettiin yrityksen robottihitsauksen lähtötilanne ja selvitettiin ongelmakohtien perusteella kehittämistoimenpiteitä. Tutkimuksissa seurattiin ja havainnoitiin hitsaustuotannon eri vaiheita, minkä perusteella laadittiin erilaisia parannuskeinoja. Toimenpiteistä saatavan hyödyn arviointiin käytettiin yrityksen tuotantoon sopivia mittareita kuten läpimenoaikaa ja kaariaikasuhdetta. Havaittujen ongelmakohtien perusteella ryhdyttiin kehittämään hitsauskiinnittimien suunnittelua ja käsittelylaitteiden käyttöä hitsaustuotannossa sekä hyödyntämään etäohjelmointia tuotteiden viennissä robottiasemille. Lisäksi robottiasemien käyttöastetta pyrittiin nostamaan tutkimalla käsinhitsattavia tuotteita ja siirtämällä niistä robotille soveltuvimmat robottiasemille hitsattavaksi.
Resumo:
Hybrid bioisoster derivatives from N-acylhydrazones and furoxan groups were designed with the objective of obtaining at least a dual mechanism of action: cruzain inhibition and nitric oxide (NO) releasing activity. Fifteen designed compounds were synthesized varying the substitution in N-acylhydrazone and in furoxan group as well. They had its anti-Trypanosoma cruzi activity in amastigotes forms, NO releasing potential and inhibitory cruzain activity evaluated. The two most active compounds (6, 14) both in the parasite amastigotes and in the enzyme contain the nitro group in para position of the aromatic ring. The permeability screening in Caco-2 cell and cytotoxicity assay in human cells were performed for those most active compounds and both showed to be less cytotoxic than the reference drug, benznidazole. Compound 6 was the most promising, since besides activity it showed good permeability and selectivity index, higher than the reference drug. Thereby the compound 6 was considered as a possible candidate for additional studies.
Resumo:
Split-plot design (SPD) and near-infrared chemical imaging were used to study the homogeneity of the drug paracetamol loaded in films and prepared from mixtures of the biocompatible polymers hydroxypropyl methylcellulose, polyvinylpyrrolidone, and polyethyleneglycol. The study was split into two parts: a partial least-squares (PLS) model was developed for a pixel-to-pixel quantification of the drug loaded into films. Afterwards, a SPD was developed to study the influence of the polymeric composition of films and the two process conditions related to their preparation (percentage of the drug in the formulations and curing temperature) on the homogeneity of the drug dispersed in the polymeric matrix. Chemical images of each formulation of the SPD were obtained by pixel-to-pixel predictions of the drug using the PLS model of the first part, and macropixel analyses were performed for each image to obtain the y-responses (homogeneity parameter). The design was modeled using PLS regression, allowing only the most relevant factors to remain in the final model. The interpretation of the SPD was enhanced by utilizing the orthogonal PLS algorithm, where the y-orthogonal variations in the design were separated from the y-correlated variation.
Resumo:
In Brazil, the consumption of extra-virgin olive oil (EVOO) is increasing annually, but there are no experimental studies concerning the phenolic compound contents of commercial EVOO. The aim of this work was to optimise the separation of 17 phenolic compounds already detected in EVOO. A Doehlert matrix experimental design was used, evaluating the effects of pH and electrolyte concentration. Resolution, runtime and migration time relative standard deviation values were evaluated. Derringer's desirability function was used to simultaneously optimise all 37 responses. The 17 peaks were separated in 19min using a fused-silica capillary (50μm internal diameter, 72cm of effective length) with an extended light path and 101.3mmolL(-1) of boric acid electrolyte (pH 9.15, 30kV). The method was validated and applied to 15 EVOO samples found in Brazilian supermarkets.
Resumo:
Herein we describe the synthesis of a focused library of compounds based on the structure of goniothalamin (1) and the evaluation of the potential antitumor activity of the compounds. N-Acylation of aza-goniothalamin (2) restored the in vitro antiproliferative activity of this family of compounds. 1-(E)-But-2-enoyl-6-styryl-5,6-dihydropyridin-2(1H)-one (18) displayed enhanced antiproliferative activity. Both goniothalamin (1) and derivative 18 led to reactive oxygen species generation in PC-3 cells, which was probably a signal for caspase-dependent apoptosis. Treatment with derivative 18 promoted Annexin V/7-aminoactinomycin D double staining, which indicated apoptosis, and also led to G2 /M cell-cycle arrest. In vivo studies in Ehrlich ascitic and solid tumor models confirmed the antitumor activity of goniothalamin (1), without signs of toxicity. However, derivative 18 exhibited an unexpectedly lower in vivo antitumor activity, despite the treatments being administered at the same site of inoculation. Contrary to its in vitro profile, aza-goniothalamin (2) inhibited Ehrlich tumor growth, both on the ascitic and solid forms. Our findings highlight the importance of in vivo studies in the search for new candidates for cancer treatment.
Resumo:
An HPLC-PAD method using a gold working electrode and a triple-potential waveform was developed for the simultaneous determination of streptomycin and dihydrostreptomycin in veterinary drugs. Glucose was used as the internal standard, and the triple-potential waveform was optimized using a factorial and a central composite design. The optimum potentials were as follows: amperometric detection, E1=-0.15V; cleaning potential, E2=+0.85V; and reactivation of the electrode surface, E3=-0.65V. For the separation of the aminoglycosides and the internal standard of glucose, a CarboPac™ PA1 anion exchange column was used together with a mobile phase consisting of a 0.070 mol L(-1) sodium hydroxide solution in the isocratic elution mode with a flow rate of 0.8 mL min(-1). The method was validated and applied to the determination of streptomycin and dihydrostreptomycin in veterinary formulations (injection, suspension and ointment) without any previous sample pretreatment, except for the ointments, for which a liquid-liquid extraction was required before HPLC-PAD analysis. The method showed adequate selectivity, with an accuracy of 98-107% and a precision of less than 3.9%.
Resumo:
For centuries, specific instruments or regular toothbrushes have routinely been used to remove tongue biofilm and improve breath odor. Toothbrushes with a tongue scraper on the back of their head have recently been introduced to the market. The present study compared the effectiveness of a manual toothbrush with this new design, i.e., possessing a tongue scraper, and a commercial tongue scraper in improving breath odor and reducing the aerobic and anaerobic microbiota of tongue surface. The evaluations occurred at 4 moments, when the participants (n=30) had their halitosis quantified with a halimeter and scored according to a 4-point scoring system corresponding to different levels of intensity. Saliva was collected for counts of aerobic and anaerobic microorganisms. Data were analyzed statistically by Friedman's test (p<0.05). When differences were detected, the Wilcoxon test adjusted for Bonferroni correction was used for multiple comparisons (group to group). The results confirmed the importance of mechanical cleaning of the tongue, since this procedure provided an improvement in halitosis and reduction of aerobe and anaerobe counts. Regarding the evaluated methods, the toothbrush's tongue scraper and conventional tongue scraper had a similar performance in terms of breath improvement and reduction of tongue microbiota, and may be indicated as effective methods for tongue cleaning.
Resumo:
This study evaluated the effect of specimens' design and manufacturing process on microtensile bond strength, internal stress distributions (Finite Element Analysis - FEA) and specimens' integrity by means of Scanning Electron Microscopy (SEM) and Laser Scanning Confocal Microscopy (LCM). Excite was applied to flat enamel surface and a resin composite build-ups were made incrementally with 1-mm increments of Tetric Ceram. Teeth were cut using a diamond disc or a diamond wire, obtaining 0.8 mm² stick-shaped specimens, or were shaped with a Micro Specimen Former, obtaining dumbbell-shaped specimens (n = 10). Samples were randomly selected for SEM and LCM analysis. Remaining samples underwent microtensile test, and results were analyzed with ANOVA and Tukey test. FEA dumbbell-shaped model resulted in a more homogeneous stress distribution. Nonetheless, they failed under lower bond strengths (21.83 ± 5.44 MPa)c than stick-shaped specimens (sectioned with wire: 42.93 ± 4.77 MPaª; sectioned with disc: 36.62 ± 3.63 MPa b), due to geometric irregularities related to manufacturing process, as noted in microscopic analyzes. It could be concluded that stick-shaped, nontrimmed specimens, sectioned with diamond wire, are preferred for enamel specimens as they can be prepared in a less destructive, easier, and more precise way.
Resumo:
This work describes the construction and testing of a simple pressurized solvent extraction (PSE) system. A mixture of acetone:water (80:20), 80 ºC and 103.5 bar, was used to extract two herbicides (Diuron and Bromacil) from a sample of polluted soil, followed by identification and quantification by high-performance liquid chromatography coupled with diode array detector (HPLC-DAD). The system was also used to extract soybean oil (70 ºC and 69 bar) using pentane. The extracted oil was weighed and characterized through the fatty acid methyl ester analysis (myristic (< 0.3%), palmitic (16.3%), stearic (2.8%), oleic (24.5%), linoleic (46.3%), linolenic (9.6%), araquidic (0.3%), gadoleic (< 0.3%), and behenic (0.3%) acids) using high-resolution gas chromatography with flame ionization detection (HRGC-FID). PSE results were compared with those obtained using classical procedures: Soxhlet extraction for the soybean oil and solid-liquid extraction followed by solid-phase extraction (SLE-SPE) for the herbicides. The results showed: 21.25 ± 0.36% (m/m) of oil in the soybeans using the PSE system and 21.55 ± 0.65% (m/m) using the soxhlet extraction system; extraction efficiency (recovery) of herbicides Diuron and Bromacil of 88.7 ± 4.5% and 106.6 ± 8.1%, respectively, using the PSE system, and 96.8 ± 1.0% and 94.2 ± 3.9%, respectively, with the SLP-SPE system; limit of detection (LOD) and limit of quantification (LOQ) for Diuron of 0.012 mg kg-1 and 0.040 mg kg-1, respectively; LOD and LOQ for Bromacil of 0.025 mg kg-1 and 0.083 mg kg-1, respectively. The linearity used ranged from 0.04 to 1.50 mg L-1 for Diuron and from 0.08 to 1.50 mg L-1 for Bromacil. In conclusion, using the PSE system, due to high pressure and temperature, it is possible to make efficient, fast extractions with reduced solvent consumption in an inert atmosphere, which prevents sample and analyte decomposition.
Resumo:
This paper revisits the design of L and S band bridged loop-gap resonators (BLGRs) for electron paramagnetic resonance applications. A novel configuration is described and extensively characterized for resonance frequency and quality factor as a function of the geometrical parameters of the device. The obtained experimental results indicate higher values of the quality factor (Q) than previously reported in the literature, and the experimental analysis data should provide useful guidelines for BLGR design.