999 resultados para echo-signal


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study has developed an improved subjective approach of classification in conjunction with Step wise DFA analysis to discriminate Chinese sturgeon signals from other targets. The results showed that all together 25 Chinese sturgeon echo-signals were detected in the spawning ground of Gezhouba Dam during the last 3 years, and the identification accuracy reached 90.9%. In Stepwise DFA, 24 out of 67 variables were applied in discrimination and identification. PCA combined with DFA was then used to ensure the significance of the 24 variables and detailed the identification pattern. The results indicated that we can discriminate Chinese sturgeon from other fish species and noise using certain descriptors such as the behaviour variables, echo characteristics and acoustic cross-section characteristics. However, identification of Chinese sturgeon from sediments is more difficult and needs a total of 24 variables. This is due to the limited knowledge about the acoustic-scattering properties of the substrate regions. Based on identified Chinese sturgeon individuals, 18 individuals were distributed in the region between the site of Gezhouba Dam and Miaozui reach, with a surface area of about 3.4 km(2). Seven individuals were distributed in the region between Miaozui and Yanshouba reach, with a surface area of about 13 km(2).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Since the discovery of the nuclear magnetic resonance (NMR) phenomenon, countless NMR techniques have been developed that are today indispensable tools in physics, chemistry, biology, and medicine. As one of the main obstacles in NMR is its notorious lack of sensitivity, different hyperpolarization (HP) methods have been established to increase signals up to several orders of magnitude. In this work, different aspects of magnetic resonance, using HP noble gases, are studied, hereby combining different disciplines of research. The first part examines new fundamental effects in NMR of HP gases, in theory and experiment. The spin echo phenomenon, which provides the basis of numerous modern experiments, is studied in detail in the gas phase. The changes of the echo signal in terms of amplitude, shape, and position, due to the fast translational motion, are described by an extension of the existing theory and computer simulations. With this knowledge as a prerequisite, the detection of intermolecular double-quantum coherences was accomplished for the first time in the gas phase. The second part of this thesis focuses on the development of a practical method to enhance the dissolution process of HP 129Xe, without loss of polarization or shortening of T1. Two different setups for application in NMR spectroscopy and magnetic resonance imaging (MRI) are presented. The continuous operation allows biological and multidimensional spectroscopy in solutions. Also, first in vitro MRI images with dissolved HP 129Xe as contrast agent were obtained at a clinical scanner.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The in situ real time measurement of the regression rate of a melting interface (RRMI) is performed by the ultrasonic measurement system reported here. The RRMI is the rate at which a solid/liquid interface (SLI) moves along a metallic rod while burning in an oxygen-enriched atmosphere and is an important flatnmability indicator. The ultrasonic transducer and associated equipment used to drive the transducer and record the echo signal is described, along with the process that transforms the acquired signals into a RRMI value. Test rods of various metals and geometric shapes were burned at several test conditions in different test facilities. The RRMI results with quantified errors are presented and reviewed. The effect of reduced gravity on burning metals is important to space-applications and RRMI results obtained in a reduced gravity environment are also presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To prospectively evaluate a 3-dimensional spoiled gradient-dual-echo (3D SPGR-DE) magnetic resonance imaging (MRI) sequence for the qualitative and quantitative analysis of liver fat content (LFC) in patients with the suspicion of fatty liver disease using histopathology as the standard of reference.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To study the utility of fractional calculus in modeling gradient-recalled echo MRI signal decay in the normal human brain. METHODS We solved analytically the extended time-fractional Bloch equations resulting in five model parameters, namely, the amplitude, relaxation rate, order of the time-fractional derivative, frequency shift, and constant offset. Voxel-level temporal fitting of the MRI signal was performed using the classical monoexponential model, a previously developed anomalous relaxation model, and using our extended time-fractional relaxation model. Nine brain regions segmented from multiple echo gradient-recalled echo 7 Tesla MRI data acquired from five participants were then used to investigate the characteristics of the extended time-fractional model parameters. RESULTS We found that the extended time-fractional model is able to fit the experimental data with smaller mean squared error than the classical monoexponential relaxation model and the anomalous relaxation model, which do not account for frequency shift. CONCLUSIONS We were able to fit multiple echo time MRI data with high accuracy using the developed model. Parameters of the model likely capture information on microstructural and susceptibility-induced changes in the human brain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Single scan longitudinal relaxation measurement experiments enable rapid estimation of the spin-lattice relaxation time (T-1) as the time series of spin relaxation is encoded spatially in the sample at different slices resulting in an order of magnitude saving in time. We consider here a single scan inversion recovery pulse sequence that incorporates a gradient echo sequence. The proposed pulse sequence provides spectra with significantly enhanced signal to noise ratio leading to an accurate estimation of T-1 values. The method is applicable for measuring a range of T-1 values, thus indicating the possibility of routine use of the method for several systems. A comparative study of different single scan methods currently available is presented, and the advantage of the proposed sequence is highlighted. The possibility of the use of the method for the study of cross-correlation effects for the case of fluorine in a single shot is also demonstrated. Copyright (C) 2015 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Single scan longitudinal relaxation measurement experiments enable rapid estimation of the spin-lattice relaxation time (T-1) as the time series of spin relaxation is encoded spatially in the sample at different slices resulting in an order of magnitude saving in time. We consider here a single scan inversion recovery pulse sequence that incorporates a gradient echo sequence. The proposed pulse sequence provides spectra with significantly enhanced signal to noise ratio leading to an accurate estimation of T-1 values. The method is applicable for measuring a range of T-1 values, thus indicating the possibility of routine use of the method for several systems. A comparative study of different single scan methods currently available is presented, and the advantage of the proposed sequence is highlighted. The possibility of the use of the method for the study of cross-correlation effects for the case of fluorine in a single shot is also demonstrated. Copyright (C) 2015 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Functional MRI (fMRI) can detect blood oxygenation level dependent (BOLD) hemodynamic responses secondary to neuronal activity. The most commonly used method for detecting fMRI signals is the gradient-echo echo-planar imaging (EPI) technique because of its sensitivity and speed. However, it is generally believed that a significant portion of these signals arises from large veins, with additional contribution from the capillaries and parenchyma. Early experiments using diffusion-weighted gradient-echo EPI have suggested that intra-voxel incoherent motion (IVIM) weighting inherent in the sequence can selectively attenuate contributions from different vessels based on the differences in the mobility of the blood within them. In the present study, we used similar approach to characterize the apparent diffusion coefficient (ADC) distribution within the activated areas of BOLD contrast. It is shown that the voxel values of the ADCs obtained from this technique can infer various vascular contributions to the BOLD signal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In most diffusion tensor imaging (DTI) studies, images are acquired with either a partial-Fourier or a parallel partial-Fourier echo-planar imaging (EPI) sequence, in order to shorten the echo time and increase the signal-to-noise ratio (SNR). However, eddy currents induced by the diffusion-sensitizing gradients can often lead to a shift of the echo in k-space, resulting in three distinct types of artifacts in partial-Fourier DTI. Here, we present an improved DTI acquisition and reconstruction scheme, capable of generating high-quality and high-SNR DTI data without eddy current-induced artifacts. This new scheme consists of three components, respectively, addressing the three distinct types of artifacts. First, a k-space energy-anchored DTI sequence is designed to recover eddy current-induced signal loss (i.e., Type 1 artifact). Second, a multischeme partial-Fourier reconstruction is used to eliminate artificial signal elevation (i.e., Type 2 artifact) associated with the conventional partial-Fourier reconstruction. Third, a signal intensity correction is applied to remove artificial signal modulations due to eddy current-induced erroneous T2(∗) -weighting (i.e., Type 3 artifact). These systematic improvements will greatly increase the consistency and accuracy of DTI measurements, expanding the utility of DTI in translational applications where quantitative robustness is much needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The coefficients of an echo canceller with a near-end section and a far-end section are usually updated with the same updating scheme, such as the LMS algorithm. A novel scheme is proposed for echo cancellation that is based on the minimisation of two different cost functions, i.e. one for the near-end section and a different one for the far-end section. The approach considered leads to a substantial improvement in performance over the LMS algorithm when it is applied to both sections of the echo canceller. The convergence properties of the algorithm are derived. The proposed scheme is also shown to be robust to noise variations. Simulation results confirm the superior performance of the new algorithm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A family of stochastic gradient algorithms and their behaviour in the data echo cancellation work platform are presented. The cost function adaptation algorithms use an error exponent update strategy based on an absolute error mapping, which is updated at every iteration. The quadratic and nonquadratic cost functions are special cases of the new family. Several possible realisations are introduced using these approaches. The noisy error problem is discussed and the digital recursive filter estimator is proposed. The simulation outcomes confirm the effectiveness of the proposed family of algorithms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For a digital echo canceller it is desirable to reduce the adaptation time, during which the transmission of useful data is not possible. LMS is a non-optimal algorithm in this case as the signals involved are statistically non-Gaussian. Walach and Widrow (IEEE Trans. Inform. Theory 30 (2) (March 1984) 275-283) investigated the use of a power of 4, while other research established algorithms with arbitrary integer (Pei and Tseng, IEEE J. Selected Areas Commun. 12(9)(December 1994) 1540-1547) or non-quadratic power (Shah and Cowan, IEE.Proc.-Vis. Image Signal Process. 142 (3) (June 1995) 187-191). This paper suggests that continuous and automatic, adaptation of the error exponent gives a more satisfactory result. The family of cost function adaptation (CFA) stochastic gradient algorithm proposed allows an increase in convergence rate and, an improvement of residual error. As special case the staircase CFA algorithm is first presented, then the smooth CFA is developed. Details of implementations are also discussed. Results of simulation are provided to show the properties of the proposed family of algorithms. (C) 2000 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a novel bipolar time-spread (TS) echo hiding based watermarking method is proposed for stereo audio signals, to overcome the low robustness problem in the traditional TS echo hiding method. At the embedding, echo signals with opposite polarities are added to both channels of the host audio signal. This improves the imperceptibility of the watermarking scheme, since added watermarks have similar effects in both channels. Then decoding part is developed, in order to improve the robustness of the watermarking scheme against common attacks. Since these novel embedding and decoding methods utilize the advantage of two channels in stereo audio signals, it significantly reduces the interference of host signal at watermark extraction which is the main reason for error detection in the traditional TS echo hiding based watermarking under closed-loop attack. The effectiveness of the proposed watermarking scheme is theoretically analyzed and verified by simulations under common attacks. The proposed echo hiding method outperforms conventional TS echo hiding based watermarking when their perceptual qualities are similar.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In audio watermarking, the robustness against pitch-scaling attack, is one of the most challenging problems. In this paper, we propose an algorithm, based on traditional time-spread(TS) echo hiding based audio watermarking to solve this problem. In TS echo hiding based watermarking, pitch-scaling attack shifts the location of pseudonoise (PN) sequence which appears in the cepstrum domain. Thus, position of the peak, which occurs after correlating with PN-sequence changes by an un-known amount and that causes the error. In the proposed scheme, we replace PN-sequence with unit-sample sequence and modify the decoding algorithm in such a way it will not depend on a particular point in cepstrum domain for extraction of watermark. Moreover proposed algorithm is applied to stereo audio signals to further improve the robustness. Experimental results illustrate the effectiveness of the proposed algorithm against pitch-scaling attacks compared to existing methods. In addition to that proposed algorithm also gives better robustness against other conventional signal processing attacks.