943 resultados para deuterated standard
Resumo:
A short and efficient synthesis of heptadeuterated 2,2,4,4,5,7,7-d7-cholestane (1) from cholesterol (3) is described. The deuterated material will be useful for the analysis of different sources of petroleum in analytical geochemistry laboratories as internal standard for quantification of steranes via gas chromatography-mass spectrometry (GC-MS).
Resumo:
Malondialdehyde (MDA) is a natural and widespread genotoxin. Given its potentially deleterious effects, it is of interest to establish the identities of the cell types containing this aldehyde. We used in situ chemical trapping with 2-thiobarbituric acid and mass spectrometry with a deuterated standard to characterize MDA pools in the vegetative phase in Arabidopsis thaliana. In leaves, MDA occurred predominantly in the intracellular compartment of mesophyll cells and was enriched in chloroplasts where it was derived primarily from triunsaturated fatty acids (TFAs). High levels of MDA (most of which was unbound) were found within dividing cells in the root tip cell proliferation zone. The bulk of this MDA did not originate from TFAs. We confirmed the localization of MDA in transversal root sections. In addition to MDA in proliferating cells near the root tip we found evidence for the presence of MDA in pericyle cells. Remodeling of non-TFA-derived MDA pools occurred when seedlings were infected with the fungus Botrytis cinerea. Treatment of uninfected seedlings with mediators of plant stress responses (jasmonic acid or salicylic acid) increased seedling MDA levels over 20-fold. In summary, major pools of MDA are associated with cell division foci containing stem cells. The aldehyde is pathogen-inducible in these regions and its levels are increased by cellular mediators that impact defense and growth.
Resumo:
A previous study has shown the possibility to identify methane (CH4 ) using headspace-GC-MS and quantify it with a stable isotope as internal standard. The main drawback of the GC-MS methods discussed in literature for CH4 measurement is the absence of a specific internal standard necessary to perform quantification. However, it becomes essential to develop a safer method to limit the manipulation of gaseous CH4 and to precisely control the injected amount of gas for spiking and calibration by comparison with external calibration. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate a labeled gas as an internal standard in a vial on the basis of the formation of CH4 by the reaction of Grignard reagent methylmagnesium chloride with deuterated water. This method allows precise measurement of CH4 concentrations in gaseous sample as well as in a solid or a liquid sample after a thermodesorption step in a headspace vial. A full accuracy profile validation of this method is then presented.
Resumo:
High-resolution Fourier transform infrared spectra have been recorded and analyzed for the ν3, ν4, ν5, and ν6 fundamental bands of trans-DONO, and for the ν4 fundamental of cis-DONO. The spectral resolution was better than 0.01 cm−1, and the bands have been fitted using an asymmetric top Hamiltonian with a standard deviation of around 0.0006 cm−1.
A Feasibility Study Of Fricke Dosimetry As An Absorbed Dose To Water Standard For 192ir Hdr Sources.
Resumo:
High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brachytherapy sources is presented in this study. The main goal of this paper is to demonstrate the potential usefulness of the Fricke dosimetry technique for the standardization of the quantity absorbed dose to water for 192Ir sources. A molded, double-walled, spherical vessel for water containing the Fricke solution was constructed based on the Fricke system. The authors measured the absorbed dose to water and compared it with the doses calculated using the AAPM TG-43 report. The overall combined uncertainty associated with the measurements using Fricke dosimetry was 1.4% for k = 1, which is better than the uncertainties reported in previous studies. These results are promising; hence, the use of Fricke dosimetry to measure the absorbed dose to water as a standard for HDR 192Ir may be possible in the future.
Resumo:
PURPOSE: To evaluate the sensitivity and specificity of machine learning classifiers (MLCs) for glaucoma diagnosis using Spectral Domain OCT (SD-OCT) and standard automated perimetry (SAP). METHODS: Observational cross-sectional study. Sixty two glaucoma patients and 48 healthy individuals were included. All patients underwent a complete ophthalmologic examination, achromatic standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec Inc., Dublin, California). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters and global indices of SAP. Subsequently, the following MLCs were tested using parameters from the SD-OCT and SAP: Bagging (BAG), Naive-Bayes (NB), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Random Forest (RAN), Ensemble Selection (ENS), Classification Tree (CTREE), Ada Boost M1(ADA),Support Vector Machine Linear (SVML) and Support Vector Machine Gaussian (SVMG). Areas under the receiver operating characteristic curves (aROC) obtained for isolated SAP and OCT parameters were compared with MLCs using OCT+SAP data. RESULTS: Combining OCT and SAP data, MLCs' aROCs varied from 0.777(CTREE) to 0.946 (RAN).The best OCT+SAP aROC obtained with RAN (0.946) was significantly larger the best single OCT parameter (p<0.05), but was not significantly different from the aROC obtained with the best single SAP parameter (p=0.19). CONCLUSION: Machine learning classifiers trained on OCT and SAP data can successfully discriminate between healthy and glaucomatous eyes. The combination of OCT and SAP measurements improved the diagnostic accuracy compared with OCT data alone.
Resumo:
A compact frequency standard based on an expanding cold (133)CS cloud is under development in our laboratory. In a first experiment, Cs cold atoms were prepared by a magneto-optical trap in a vapor cell, and a microwave antenna was used to transmit the radiation for the clock transition. The signal obtained from fluorescence of the expanding cold atoms cloud is used to lock a microwave chain. In this way the overall system stability is evaluated. A theoretical model based on a two-level system interacting with the two microwave pulses enables interpretation for the observed features, especially the poor Ramsey fringes contrast. (C) 2008 Optical Society of America.
Resumo:
In this work we investigate the duality linking standard and tachyon scalar field homogeneous and isotropic cosmologies in N + 1 dimensions. We determine the transformation between standard and tachyon scalar fields and between their associated potentials, corresponding to the same background evolution. We show that, in general, the duality is broken at a perturbative level, when deviations from a homogeneous and isotropic background are taken into account. However, we find that for slow-rolling fields the duality is still preserved at a linear level. We illustrate our results with specific examples of cosmological relevance, where the correspondence between scalar and tachyon scalar field models can be calculated explicitly.
Resumo:
We study the massless scalar, Dirac, and electromagnetic fields propagating on a 4D-brane, which is embedded in higher-dimensional Gauss-Bonnet space-time. We calculate, in the time domain, the fundamental quasinormal modes of a spherically symmetric black hole for such fields. Using WKB approximation we study quasinormal modes in the large multipole limit. We observe also a universal behavior, independent on a field and value of the Gauss-Bonnet parameter, at an asymptotically late time.
Resumo:
An analytical procedure for multiple standard additions of arsenic species using sequential injection analysis (SIA) is proposed for their quantification in seafood extracts. SIA presented flexibility for generating multiple specie standards at the ng mL(-1) concentration level by adding different volumes of As(III), As(V), monomethylarsonic (MMA) and dimethylarsinic (DMA) to the sample. The mixed sample plus standard solutions were delivered from SIA to fill the HPLC injection loop. Subsequently, As species were separated by HPLC and analyzed by atomic fluorescence spectrometry (AFS). The proposed system comprised two independently controlled modules, with the HPLC loop acting as the intermediary device. The analytical frequency was enhanced by combining the actions of both modules. While the added sample was flowing through the chromatographic column towards the detection system, the SIA program started performing the standard additions to another sample. The proposed method was applied to spoiled seafood extracts. Detection limits based on 3 sigma for As(III), As(V), MMA and DMA were 0.023, 0.39, 0.45 and 1.0 ng mL(-1), respectively. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Background: Although the Clock Drawing Test (CDT) is the second most used test in the world for the screening of dementia, there is still debate over its sensitivity specificity, application and interpretation in dementia diagnosis. This study has three main aims: to evaluate the sensitivity and specificity of the CDT in a sample composed of older adults with Alzheimer`s disease (AD) and normal controls; to compare CDT accuracy to the that of the Mini-mental State Examination (MMSE) and the Cambridge Cognitive Examination (CAMCOG), and to test whether the association of the MMSE with the CDT leads to higher or comparable accuracy as that reported for the CAMCOG. Methods: Cross-sectional assessment was carried out for 121 AD and 99 elderly controls with heterogeneous educational levels from a geriatric outpatient clinic who completed the Cambridge Examination for Mental Disorder of the Elderly (CAMDEX). The CDT was evaluated according to the Shulman, Mendez and Sunderland scales. Results: The CDT showed high sensitivity and specificity. There were significant correlations between the CDT and the MMSE (0.700-0.730; p < 0.001) and between the CDT and the CAMCOG (0.753-0.779; p < 0.001). The combination of the CDT with the MMSE improved sensitivity and specificity (SE = 89.2-90%; SP = 71.7-79.8%). Subgroup analysis indicated that for elderly people with lower education, sensitivity and specificity were both adequate and high. Conclusions: The CDT is a robust screening test when compared with the MMSE or the CAMCOG, independent of the scale used for its interpretation. The combination with the MMSE improves its performance significantly, becoming equivalent to the CAMCOG.
Resumo:
A Thermodynamic air-standard cycle was envisaged for Ranque-Hilsh (R-H) or Vortex Tubes to provide relevant Thermodynamic analysis and tools for setting operating limits according to the conservation laws of mass and energy, as well as the constraint of the Second Law of Thermodynamics. The study used an integral or control volume approach and resulted in establishing working equations for evaluating the performance of an R-H tube. The work proved that the coefficient of performance does not depend on the R-H tube operating mode, i.e., the same value is obtained independently if the R-H tube operates either as a heat pump or as a refrigeration device. It was also shown that the isentropic coefficient of performance displays optima values of cold and hot mass fractions for a given operating pressure ratio. Finally, the study was concluded by comparing the present analysis with some experimental data available in the literature for operating pressures ranging 2-11 atm. (C) 2010 Elsevier Ltd and IIR. All rights reserved.
Resumo:
This work shows a comparison between the analog performance of standard and strained Si n-type triple-gate FinFETs with high-K dielectrics and TiN gate material. Different channel lengths and fin widths are studied. It is demonstrated that both standard and strained FinFETs with short channel length and narrow fins have similar analog properties, whereas the increase of the channel length degrades the early voltage of the strained devices, consequently decreasing the device intrinsic voltage gain with respect to standard ones. Narrow strained FinFETs with long channel show a degradation of the Early voltage if compared to standard ones suggesting that strained devices are more subjected to the channel length modulation effect. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
In stored grains, smaller depositions and great variation with respect to theoretical insecticide doses are frequently found. The objective of this work was to study the effectiveness of the standard method (ISO 5682/1-1996) employed to evaluate hydraulic nozzles used in stored corn and wheat grain protection experiments. The transversal volumetric distribution and droplet spectrum of a model TJ-60 8002EVS nozzle were determined in order to calibrate a spraying system for an application rate of 5 L/t and to obtain theoretical concentrations of 10 and 0.5 mg/kg of fenitrothion and esfenvalerate, respectively. After treatment, the corn and wheat grains were processed and deposition was analyzed by gas chromatography. The type of grain did not have any influence on insecticide deposition and was dependent upon insecticide only. The insecticide deposits on the grains only reached 42.1 and 38.2% of the intended theoretical values for fenitrothion and esfenvalerate concentrations, respectively. These results demonstrate the ineffectiveness of the standard evaluation method for hydraulic nozzles employed in stored grain protection experiments.