978 resultados para dental implantation
Resumo:
The aim of this literature review is to discuss the use of dental implants in growing patients and the influence of maxillary and mandibular skeletal and dental growth on the stability of those implants. It is recommended to wait for the completion of dental and skeletal growth, except for severe cases of ectodermal dysplasia.
Resumo:
The oral rehabilitation by dental implants in patients with diabetes remains a controversial issue. The aim of this study was to evaluate the influence of diabetes mellitus and insulin therapy on the bone healing around dental implants using torque removal. Twenty-seven rabbits were randomly divided into 3 groups with 9 animals each: control (C) group, induced diabetic (D) group, and insulin-treated diabetic (ITD) group (10 U/day). After 1 week, one implant was inserted at the tibial metaphysis of the animals. The glucose levels were periodically evaluated through the glucose-oxidase enzymatic method. The animals were killed at 4, 8, and 12 weeks after surgery and the biomechanical test was performed using a torque manometer. Statistically significant differences regarding the removal torque of the implant could not be found at 4 weeks (P = 0.2) among groups. Group C showed statistically higher values than groups D and ITD at the experimental periods of 8 (P = 0.0001 and P = 0.0002, respectively) and 12 weeks (P = 0.0053 and P = 0.001, respectively). There were no statistical differences between D and ITD groups in any of the experimental periods. Diabetes mellitus has negatively influenced the mechanical retention of implants placed at the tibial metaphysis of rabbits. Therapy with insulin did not induce any changes.
Resumo:
Purpose: Tissue reactions to 4 different implant surfaces were evaluated in regard to the development and progression of ligature-induced peri-implantitis. Materials and Methods: In 6 male mongrel dogs, a total of 36 dental implants with different surfaces (9 titanium plasma-sprayed, 9 hydroxyapatite-coated, 9 acid-etched, and 9 commercially pure titanium) were placed 3 months after mandibular premolar extraction. After 3 months with optimal plaque control, abutment connection was performed. Forty-five days later, cotton ligatures were placed around the implants to induce peri-implantitis. At baseline and 20, 40, and 60 days after placement, the presence of plaque, peri-implant mucosal redness, bleeding on probing, probing depth, clinical attachment loss, mobility, vertical bone loss, and horizontal bone loss were assessed. Results: The results did not show significant differences among the surfaces for any parameter during the study (P > .05). All surfaces were equally susceptible to ligature-induced peri-implantitis over time (P < .001). Correlation analysis revealed a statistically significant relationship between width of keratinized tissue and vertical bone loss (r 2 = 0.81; P = .014) and between mobility and vertical bone loss (r 2 = 0.66; P = .04), both for the titanium plasma-sprayed surface. Discussion and Conclusions: The present data suggest that all surfaces were equally susceptible to experimental peri-implantitis after a 60-day period.
Resumo:
This study evaluated 3 implant surfaces in a dog model: (1) resorbable-blasting media + acid-etched (RBMa), alumina-blasting + acid-etching (AB/AE), and AB/AE + RBMa (hybrid). All of the surfaces were minimally rough, and Ca and P were present for the RBMa and hybrid surfaces. Following 2 weeks in vivo, no significant differences were observed for torque, bone-to-implant contact, and bone-area fraction occupied measurements. Newly formed woven bone was observed in proximity with all surfaces.
Resumo:
OBJECTIVE: The aim of this study was to gather information and discuss the predictability of implant-supported prostheses in patients with bruxism by performing a literature review. METHODS: In order to select the studies included in this review, a detailed search was performed in PubMed and Medline databases, using the following key words: bruxism, dental implants, implant supported prosthesis, and dental restoration failure. Items that were included are: case reports, randomized controlled trials, in vitro studies, literature and systematic reviews, with or without meta-analysis, of the last 20 years that addressed the theme. Articles without abstracts, animal studies, articles in languages other than English and articles from journals unrelated to the dental field were excluded. RESULTS: after analysis according to inclusion and exclusion criteria, 28 articles were selected from a total of 54. It is known from the array of scientific articles which have assessed, either through retrospective, prospective or experimental studies, that the biomechanical and biological impact of bruxism on implant-supported prostheses is small, and that the literature has contributed little to exemplify the prosthetic limits of safety for the specialist from a clinical point of view. CONCLUSION: Although there is still no general consensus on this matter, most of the literature review articles do provide clinical guidelines that contribute to implant supported prostheses longevity and stability in patients with bruxism.
Resumo:
Surface treatment interferes with the primary stability of dental implants because it promotes a chemical and micromorphological change on the surface and thus stimulates osseointegration. This study aimed to evaluate the effects of different surface treatments on primary stability by analyzing insertion torque (IT) and pullout force (PF). Eight samples of implants with different surface treatments (TS - external hexagon with acid surface treatment; and MS - external hexagon, machined surface), all 3.75 mm in diameter x 11.5 mm in length, were inserted into segments of artificial bones. The IT of each sample was measured by an electronic torquemeter, and then the pullout test was done with a universal testing machine. The results were subjected to ANOVA (p < 0.05), followed by Tukey's test (p < 0.05). The IT results showed no statistically significant difference, since the sizes of the implants used were very similar, and the bone used was not highly resistant. The PF values (N) were, respectively, TS = 403.75 +/- 189.80 and MS = 276.38 +/- 110.05. The implants were shown to be different in terms of the variables of maximum force (F = 4.401, p = 0.0120), elasticity in maximum flexion (F = 3.672, p = 0.024), and relative stiffness (F = 4.60, p = 0.01). In this study, external hexagonal implants with acid surface treatment showed the highest values of pullout strength and better stability, which provide greater indication for their use.
Resumo:
Little data concerning the perceived success of implant therapy in comparison with endodontic treatment exists. While the criteria used to measure the outcome of each modality are not the same, it is not clear if this is appreciated by practicing dentists. The purpose of the study was to evaluate the perceived outcome of implant therapy in comparison to endodontic treatment. A 23 question Web-based survey was distributed to 648 dentists who matriculated from the University of Connecticut School Of Dental Medicine over the past 30 years. The response rate was 47%. Sixty-seven percent of respondents were general dentists. Forty-nine percent of respondents did not know different criteria exist in the literature and are used to evaluate implant and root canal treatment. Fifty-four percent of dentists felt the prognosis of implant therapy was the same as or better than endodontic treatment of teeth with vital pulps. Thirty percent of responders thought root canal treatment of teeth with necrotic pulp was superior to implants and only 16% thought retreatment was preferable. Treatment planning for implant placement vs. retreatment of a restorable tooth was 46% and 32%, respectively. A third of the respondents felt that the role of endodontics will decline in the future. Dentists’ primary source of information regarding implant therapy was continuing education; however, their primary source of information regarding endodontic treatment was their dental program. Dentists felt the prognosis of implant therapy was as good or superior to endodontic treatment of teeth with vital, necrotic or previously treated pulps.
Resumo:
Calcium phosphate salts, or more specifically hydroxyapatite, are products of great interest in the fields of medical and dental science due to their biocompatibility and osteoconduction property. Deproteinized xenografts are primarily constituted of natural apatites, sintered or not. Variations in the industrial process may affect physicochemical properties and, therefore, the biological outcome. The purpose of this work was to characterize the physical and chemical properties of deproteinized xenogenic biomaterials, Bio-Oss (Geistlich Biomaterials, Wolhuser, Switzerland) and Gen-Ox (Baumer S.A., Brazil), widely used as bone grafts. Scanning electron microscopy, infrared region spectroscopy, X-ray diffraction, thermogravimetry and degradation analysis were conducted. The results show that both materials presented porous granules, composed of crystalline hydroxyapatite without apparent presence of other phases. Bio-Oss presented greater dissolution in Tris-HCl than Gen-Ox in the degradation test, possibly due to the low crystallinity and the presence of organic residues. In conclusion, both commercial materials are hydroxyapatite compounds, Bio-Oss being less crystalline than Gen-Ox and, therefore, more prone to degradation.
Resumo:
This study evaluated fracture torque by torsion, in relation to the length and diameter of orthodontic mini-implants, to demonstrate their viability for clinical and experimental use based on the torque recommended by the manufacturers. The fractures at the moment of insertion, whose incidence in the literature is around 4%, are principally due to excessive force and the inability of the implant to resist rotational forces. Thirty orthodontic mini-implants of three commercial brands available in Brazil (Neodent 1.6 x 9 mm, Dentoflex 1.6 x 9 mm and Kopp 1.6 x 9 mm) were attached to a device made specifically for this research, leaving the mini-implants with sufficient stability. The miniimplants were submitted to torsion torque, using a digital torque wrench, until their breaking point. The values obtained with the test were submitted to analysis of variance and the Tukey test. The mean values of mini-implant ruptures were 26 N.cm for group A (Dentoflex), 25.4 N. cm for group B (Kopp) and 32.8 N.cm for group C (Neodent). From the Tukey test we could observe that the relationships between the means of the Dentoflex and Neodent groups, and between the Kopp and Neodent groups, were significant. Between the Dentoflex and Kopp groups, significance was nonexistent. All the values found in our research for fracture torque were higher than the limits recommended by the manufacturers for clinical use in orthodontics. The highest values were found in the Neodent group.
Resumo:
Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.
Resumo:
OBJECTIVES: This systematic review aims to assess the risks (both thromboembolic and bleeding) of an oral anticoagulation therapy (OAT) patient undergoing implant therapy and to provide a management protocol to patients under OAT undergoing implant therapy. MATERIAL AND METHODS: Medline, Cochrane Data Base of Systematic Reviews, the Cochrane Central Register of Controlled Trials and EMBASE (from 1980 to December 2008) were searched for English-language articles published between 1966 and 2008. This search was completed by a hand research accessing the references cited in all identified publications. RESULTS: Nineteen studies were identified reporting outcomes after oral surgery procedures (mostly dental extractions in patients on OAT following different management protocols and haemostatic therapies). Five studies were randomized-controlled trials (RCTs), 11 were controlled clinical trials (CCTs) and three were prospective case series. The OAT management strategies as well as the protocols during and after surgery were different. This heterogeneity prevented any possible data aggregation and synthesis. The results from these studies are very homogeneous, reporting minor bleeding in very few patients, without a significant difference between the OAT patients who continue with the vitamin K antagonists vs. the patients who stopped this medication before surgery. These post-operative bleeding events were controlled only with local haemostatic measures: tranexamic acid mouthwashes, gelatine sponges and cellulose gauzes's application were effective. Post-operative bleeding did not correlate with the international normalised ratio (INR) status. In none of the studies was a thromboembolic event reported. CONCLUSIONS: OAT patients (INR 2-4) who do not discontinue the AC medication do not have a significantly higher risk of post-operative bleeding than non-OAT patients and they also do not have a higher risk of post-operative bleeding than OAT patients who discontinue the medication. In patients with OAT (INR 2-4) without discontinuation, topical haemostatic agents were effective in preventing post-operative bleeding. OAT discontinuation is not recommended for minor oral surgery, such as single tooth extraction or implant placement, provided that this does not involve autogenous bone grafts, extensive flaps or osteotomy preparations extending outside the bony envelope. Evidence does not support that dental implant placement in patients on OAT is contraindicated.
Resumo:
OBJECTIVES: The aim of this systematic review is to evaluate, analysing the dental literature, whether: * Patients on intravenous (IV) or oral bisphosphonates (BPs) can receive oral implant therapy and what could be the risk of developing bisphosphonate-related osteonecrosis of the jaw (BRONJ)? * Osseointegrated implants could be affected by BP therapy. MATERIAL AND METHODS: A Medline search was conducted and all publications fulfilling the inclusion and exclusion criteria from 1966 until December 2008 were included in the review. Moreover, the Cochrane Data Base of Systematic Reviews, and the Cochrane Central Register of Controlled Trials and EMBASE (from 1980 to December 2008) were searched for English-language articles published between 1966 and 2008. Literature search was completed by a hand research accessing the references cited in all identified publications. RESULTS: The literature search rendered only one prospective and three retrospective studies. The prospective controlled non-randomized clinical study followed patients with and without BP medication up to 36 months after implant therapy. The patients in the experimental group had been on oral BPs before implant therapy for periods ranging between 1 and 4 years. None of the patients developed BRONJ and implant outcome was not affected by the BP medication. The three selected retrospective studies (two case-controls and one case series) yielded very similar results. All have followed patients on oral BPs after implant therapy, with follow-up ranging between 2 and 4 years. BRONJ was never reported and implant survival rates ranged between 95% and 100%. The literature search on BRONJ including guidelines and recommendations found 59 papers, from which six were retrieved. Among the guidelines, there is a consensus on contraindicating implants in cancer patients under IV-BPs and not contraindicating dental implants in patients under oral-BPs for osteoporosis. CONCLUSIONS: From the analysis of the one prospective and the three retrospective series (217 patients), the placement of an implant may be considered a safe procedure in patients taking oral BPs for <5 years with regard to the occurrence of BRONJ since in these studies no BRONJ has been reported. Moreover, the intake of oral-BPs did not influence short-term (1-4 years) implant survival rates.
Resumo:
Currently, there are several techniques for the rehabilitation of atrophic maxillary ridges in literature. The grafting procedure using autogenous bone is considered ideal by many researchers, as it shows osteogenic capability and causes no antigenic reaction. However, this type of bone graft has some shortcomings, mainly the restricted availability of donor sites. In recent years, several alternatives have been investigated to supply the disadvantages of autogenous bone grafts. In such studies, allogeneic bone grafts, which are obtained from individuals with different genetic load, but from the same species, have been extensively used. They can be indicated in cases of arthroplasty, surgical knee reconstruction, large bone defects, and in oral and maxillofacial reconstruction. Besides showing great applicability and biocompatibility, this type of bone is available in unlimited quantities. on the other hand, allogeneic bone may have the disadvantage of transmitting infectious diseases. Atrophic maxillae can be treated with bone grafts followed by osseointegrated implants to obtain aesthetic and functional oral rehabilitation. This study aimed to show the viability of allogeneic bone grafting in an atrophic maxilla, followed by oral rehabilitation with dental implant and protocol-type prosthesis within a 3-year follow-up period by means of a clinical case report.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)