950 resultados para automotive measurement system


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This Thesis project is a part of the research conducted in Solar industry. ABSOLICON Solar Concentrator AB has invented and started production of the prospective solar concentrated system Absolicon X10. The aims of this Thesis project are designing, assembling, calibrating and putting in operation the automatic measurement system intended to evaluate distribution of density of solar radiation in the focal line of the concentrated parabolic reflectors and to measure radiation from the artificial source of light being a calibration-testing tool.On the basis of the requirements of the company’s administration and needs of designing the concentrated reflectors the operation conditions for the Sun-Walker were formulated. As the first step, the complex design of the whole system was made and division on the parts was specified. After the preliminary conducted simulation of the functions and operation conditions of the all parts were formulated.As the next steps, the detailed design of all the parts was made. Most components were ordered from respective companies. Some of the mechanical components were made in the workshop of the company. All parts of the Sun-Walker were assembled and tested. The software part, which controls the Sun-Walker work and conducts measurements of solar irradiation, was created on the LabVIEW basis. To tune and test the software part, the special simulator was designed and assembled.When all parts were assembled in the complete system, the Sun-Walker was tested, calibrated and tuned.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most external assessments of cervical range of motion assess the upper and lower cervical regions simultaneously. This study investigated the within and between days reliability of the clinical method used to bias this movement to the upper cervical region, namely measuring rotation of the head and neck in a position of full cervical flexion. Measurements were made using the Fastrak measurement system and were conducted by one operator. Results indicated high levels of within and between days repeatability (range of ICC2,1 values: 0.85-0.95). The ranges of axial rotation to right and left, measured with the neck positioned in full flexion, were approximately 56% and 50%, respectively of total cervical rotation, which relates well to the proportional division of rotation in the upper and lower cervical regions. These results suggest that this method of measuring rotation would be appropriate for use in subject studies where movement dysfunction is present in the upper cervical region, such as those with cervicogenic headache. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In any business it is very important to measure the performance and it helps to select key information to make better decisions on time. This research focuses on the design and implementation of a performance measurement system in a Portuguese medium size firm operating in the specialized health care transformation vehicles industry. From the evidence that outputs from Auto Ribeiro’s current information system is misaligned with the company’s objectives and strategy, this research tries to solve this business problem through the development of a Balanced Scorecard analysis, although there are some issues, which deserve further development.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work had two primary objectives: 1) to produce a working prototype for automated printability assessment and 2) to perform a study of available machine vision and other necessary hardware solutions. The three printability testing methods, IGT Picking,He¬liotest, and mottling, considered in this work have several different requirements and the task was to produce a single automated testing system suitable for all methods. A system was designed and built and its performance was tested using the Heliotest. Working proto¬types are important tools for implementing theoretical methods into practical systems and testing and demonstrating the methodsin real life conditions. The system was found to be sufficient for the Heliotest method. Further testing and possible modifications related to other two test methods were left for future works. A short study of available systems and solutions concerning image acquisition of machine vision was performed. The theoretical part of this study includes lighting systems, optical systems and image acquisition tools, mainly cameras and the underlying physical aspects for each portion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, a LIDAR-based 3D Dynamic Measurement System is presented and evaluated for the geometric characterization of tree crops. Using this measurement system, trees were scanned from two opposing sides to obtain two three-dimensional point clouds. After registration of the point clouds, a simple and easily obtainable parameter is the number of impacts received by the scanned vegetation. The work in this study is based on the hypothesis of the existence of a linear relationship between the number of impacts of the LIDAR sensor laser beam on the vegetation and the tree leaf area. Tests performed under laboratory conditions using an ornamental tree and, subsequently, in a pear tree orchard demonstrate the correct operation of the measurement system presented in this paper. The results from both the laboratory and field tests confirm the initial hypothesis and the 3D Dynamic Measurement System is validated in field operation. This opens the door to new lines of research centred on the geometric characterization of tree crops in the field of agriculture and, more specifically, in precision fruit growing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis was produced for the Technology Marketing unit at the Nokia Research Center. Technology marketing was a new function at Nokia Research Center, and needed an established framework with the capacity to take into account multiple aspects for measuring the team performance. Technology marketing functions had existed in other parts of Nokia, yet no single method had been agreed upon for measuring their performance. The purpose of this study was to develop a performance measurement system for Nokia Research Center Technology Marketing. The target was that Nokia Research Center Technology Marketing had a framework for separate metrics; including benchmarking for starting level and target values in the future planning (numeric values were kept confidential within the company). As a result of this research, the Balanced Scorecard model of Kaplan and Norton, was chosen for the performance measurement system for Nokia Research Center Technology Marketing. This research selected the indicators, which were utilized in the chosen performance measurement system. Furthermore, performance measurement system was defined to guide the Head of Marketing in managing Nokia Research Center Technology Marketing team. During the research process the team mission, vision, strategy and critical success factors were outlined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study is to create measurement system that is capable to measure performance in basic industry’s service centers. First it is examined what is performance and how it can be measured. The study also introduces commonly known measurement frameworks. After theory the study investigates how companies in the field of basic industry measure their operations in practise. The investigation is done examining three case examples and by analyzing survey results from basic industry companies. On the survey results focus is on what meters and measurement systems companies use. It is also viewed what measurement problems companies have faced. In the applied part of the study harmonized performance measurement system is created. The framework of the measurement system is introduced and measurement system for the target company is created. The target company felt that the harmonized performance measurement system has good potential and continues to develop it further.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of this research is creating a performance measurement system for accounting services of a large paper industry company. In this thesis there are compared different performance measurement system and then selected two systems, which are presented and compared more detailed. Performance Prism system is the used framework in this research. Performance Prism using success maps to determining objectives. Model‟s target areas are divided into five groups: stakeholder satisfaction, stakeholder contribution, strategy, processes and capabilities. The measurement system creation began by identifying stakeholders and defining their objectives. Based on the objectives are created success map. Measures are created based on the objectives and success map. Then is defined needed data for measures. In the final measurement system, there are total just over 40 measures. Each measure is defined specific target level and ownership. Number of measures is fairly large, but this is the first version of the measurement system, so the amount is acceptable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulsed electroacoustic (PEA) method is a commonly used non-destructive technique for investigating space charges. It has been developed since early 1980s. These days there is continuing interest for better understanding of the influence of space charge on the reliability of solid electrical insulation under high electric field. The PEA method is widely used for space charge profiling for its robust and relatively inexpensive features. The PEA technique relies on a voltage impulse used to temporarily disturb the space charge equilibrium in a dielectric. The acoustic wave is generated by charge movement in the sample and detected by means of a piezoelectric film. The spatial distribution of the space charge is contained within the detected signal. The principle of such a system is already well established, and several kinds of setups have been constructed for different measurement needs. This thesis presents the design of a PEA measurement system as a systems engineering project. The operating principle and some recent developments are summarised. The steps of electrical and mechanical design of the instrument are discussed. A common procedure for measuring space charges is explained and applied to verify the functionality of the system. The measurement system is provided as an additional basic research tool for the Corporate Research Centre of ABB (China) Ltd. It can be used to characterise flat samples with thickness of 0.2–0.5 mm under DC stress. The spatial resolution of the measurement is 20 μm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the problems that slows the development of off-line programming is the low static and dynamic positioning accuracy of robots. Robot calibration improves the positioning accuracy and can also be used as a diagnostic tool in robot production and maintenance. A large number of robot measurement systems are now available commercially. Yet, there is a dearth of systems that are portable, accurate and low cost. In this work a measurement system that can fill this gap in local calibration is presented. The measurement system consists of a single CCD camera mounted on the robot tool flange with a wide angle lens, and uses space resection models to measure the end-effector pose relative to a world coordinate system, considering radial distortions. Scale factors and image center are obtained with innovative techniques, making use of a multiview approach. The target plate consists of a grid of white dots impressed on a black photographic paper, and mounted on the sides of a 90-degree angle plate. Results show that the achieved average accuracy varies from 0.2mm to 0.4mm, at distances from the target from 600mm to 1000mm respectively, with different camera orientations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance measurement produces information about the operation of the business process. On the basis of this information performance of the company can be followed and improved. Balanced performance measurement system can monitor performance of several perspectives and business processes can be led according to company strategy. Major part of the costs of a company is originated from purchased goods or services are an output of the buying process emphasising the importance of a reliable performance measurement of purchasing process. In the study, theory of balanced performance measurement is orientated and framework of purchasing process performance measurement system is designed. The designed balanced performance measurement system of purchasing process is tested in case company paying attention to the available data and to other environmental enablers. The balanced purchasing performance measurement system is tested and improved during the test period and attention is paid to the definition and scaling of objectives. Found development initiatives are carried out especially in the scaling of indicators. Finally results of the study are evaluated, conclusions and additional research areas proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis the basic structure and operational principals of single- and multi-junction solar cells are considered and discussed. Main properties and characteristics of solar cells are briefly described. Modified equipment for measuring the quantum efficiency for multi-junction solar cell is presented. Results of experimental research single- and multi-junction solar cells are described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis examines how content marketing is used in B2B customer acquisition and how content marketing performance measurement system is built and utilized in this context. Literature related to performance measurement, branding and buyer behavior is examined in the theoretical part in order to identify the elements influence on content marketing performance measurement design and usage. Qualitative case study is chosen in order to gain deep understanding of the phenomenon studied. The case company is a Finnish software vendor, which operates in B2B markets and has practiced content marketing for approximately two years. The in-depth interviews were conducted with three employees from marketing department. According to findings content marketing performance measurement system’s infrastructure is based on target market’s decision making processes, company’s own customer acquisition process, marketing automation tool and analytics solutions. The main roles of content marketing performance measurement system are measuring performance, strategy management and learning and improvement. Content marketing objectives in the context of customer acquisition are enhancing brand awareness, influencing brand attitude and lead generation. Both non-financial and financial outcomes are assessed by single phase specific metrics, phase specific overall KPIs and ratings related to lead’s involvement.