1000 resultados para Tridimensional analysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective The aim of this study was to evaluate repair after endodontic surgery using two- and tridimensional imaging methods. Materials and methods Periapical radiographs and cone beam computed tomography (CBCT) were performed before the surgeries and after 48 h (baseline), 4 months, and 8 months. The area (square millimeters) of periapical lesions in CBCT and in radiographs was compared regarding the percentage of repair. In the CBCT, multiple areas were converted to volume. Repeated-measures analyses and paired t tests (α=0.05) were used to compare the methods. Correlation coefficients were calculated between the periods of evaluation within the CBCT volumetric analysis. Bland-Altman plots were used to compare the methods, based on the 95 % limits of agreement for the difference of the means. Results Baseline showed a larger lesion volume (192.54 mm3 ) than 4-month (79.79 mm3 ) and 8-month (47.51 mm3 ) periods. No differences were found in the percentage of repair in the first 4 months and after 8 months. The volumetric analysis showed a higher percentage of repair when the first and last 4 months were compared. No differences were found in the percentage of repair by area in the CBCTs. Repair of 73 % was obtained after 8 months. Similar results were observed by the Bland-Altman agreement analyses. Conclusions The percentage of repair varied after 8 months, when lower values were obtained by volumetric evaluation. Clinical relevance Considering the outcome at follow-up periods over 4 months, tridimensional evaluation by CBCT is more capable of determining the absence of periapical bone repair than conventional two-dimensional radiographs. Therefore, the use of CBCT would be suggested only for more complex cases with slower evolution of repair or for the association of factors that make prognosis difficult after surgery.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de mestrado em Engenharia Humana

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Durante a análise sísmica de estruturas complexas, o modelo matemático empregado deveria incluir não só as distribuicões irregulares de massas e de rigidezes senão também à natureza tridimensional da ecitação sísmica. Na prática, o elevado número de graus de liberdade involucrado limita este tipo de análise à disponibilidade de grandes computadoras. Este trabalho apresenta um procedimento simplificado, para avaliar a amplificação do movimento sísmico em camadas de solos. Sua aplicação permitiria estabelecer critérios a partir dos quais avalia-se a necessidade de utilizar modelos de interação solo-estrutura mais complexos que os utilizados habitualmente. O procedimento proposto possui as seguientes características : A- Movimento rígido da rocha definido em termos de três componentes ortagonais. Direção de propagação vertical. B- A ecuação constitutiva do solo inclui as características de não linearidade, plasticidade, dependência da história da carga, dissipação de energia e variação de volume. C- O perfil de solos é dicretizado mediante um sistema de massas concentradas. Utiliza-se uma formulação incremental das equações de movimento com integração directa no domínio do tempo. As propriedades pseudo-elásticas do solo são avaliadas em cada intervalo de integração, em função do estado de tensões resultante da acção simultânea das três componentes da excitação. O correcto funcionamento do procedimento proposto é verificado mediante análises unidimensionais (excitação horizontal) incluindo estudos comparativos com as soluções apresentadas por diversos autores. Similarmente apresentam-se análises tridimensionais (acção simultânea das três componentes da excitação considerando registros sísmicos reais. Analisa-se a influência que possui a dimensão da análise (uma análise tridimensional frente a três análises unidimensionais) na resposta de camadas de solos submetidos a diferentes níveis de exçitação; isto é, a limitação do Princípio de Superposisão de Efeitos.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this study was to evaluate stress distribution in the hybrid layer produced by two adhesive systems using three-dimensional finite element analysis (FEA). Four FEA models (M) were developed: Mc, a representation of a dentin specimen (41 x 41 x 82 mu m) restored with composite resin, exhibiting the adhesive layer, hybrid layer (HL), resin tags, peritubular dentin, and intertubular dentin to simulate the etch-and-rinse adhesive system; Mr, similar to Mc, with lateral branches of the adhesive; Ma, similar to Mc, however without resin tags and obliterated tubule orifice, to simulate the environment for the self-etching adhesive system; Mat, similar to Ma, with tags. A numerical simulation was performed to obtain the maximum principal stress (sigma(max)). The highest sigma(max) in the HL was observed for the etch-and-rinse adhesive system. The lateral branches increased the sigma(max) in the HL. The resin tags had a little influence on stress distribution with the self-etching system. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Long-term follow-up after endovascular aneurysm repair (EVAR) is very scarce, and doubt remains regarding the durability of these procedures. We designed a retrospective cohort study to assess long-term clinical outcome and morphologic changes in patients with abdominal aortic aneurysms (AAAs) treated by EVAR using the Excluder endoprosthesis (W. L. Gore and Associates, Flagstaff, Ariz). METHODS: From 2000 to 2007, 179 patients underwent EVAR in a tertiary institution. Clinical data were retrieved from a prospective database. All patients treated with the Excluder endoprosthesis were included. Computed tomography angiography (CTA) scans were retrospectively analyzed preoperatively, at 30 days, and at the last follow-up using dedicated tridimensional reconstruction software. For patients with complications, all remaining CTAs were also analyzed. The primary end point was clinical success. Secondary end points were freedom from reintervention, sac growth, types I and III endoleak, migration, conversion to open repair, and AAA-related death or rupture. Neck dilatation, renal function, and overall survival were also analyzed. RESULTS: Included were 144 patients (88.2% men; mean age, 71.6 years). Aneurysms were ruptured in 4.9%. American Society of Anesthesiologists classification was III/IV in 61.8%. No patients were lost during a median follow-up of 5.0 years (interquartile range, 3.1-6.4; maximum, 11.2 years). Two patients died of medical complications ≤ 30 days after EVAR. The estimated primary clinical success rates at 5 and 10 years were 63.5% and 41.1%, and secondary clinical success rates were 78.3% and 58.3%, respectively. Sac growth was observed in 37 of 142 patients (26.1%). Cox regression showed type I endoleak during follow-up (hazard ratio, 3.74; P = .008), original design model (hazard ratio, 3.85; P = .001), and preoperative neck diameter (1.27 per mm increase, P = .006) were determinants of sac growth. Secondary interventions were required in 32 patients (22.5%). The estimated 10-year rate of AAA-related death or rupture was 2.1%. Overall life expectancy after AAA repair was 6.8 years. CONCLUSIONS: EVAR using the Excluder endoprosthesis provides a safe and lasting treatment for AAA, despite the need for maintained surveillance and secondary interventions. At up to 11 years, the risk of AAA-related death or postimplantation rupture is remarkably low. The incidences of postimplantation sac growth and secondary intervention were greatly reduced after the introduction of the low-permeability design in 2004.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Determinar valores de referência para o volume da placenta entre 7 e 10 semanas e 6 dias de gestação por meio da ultrassonografia tridimensional utilizando o método XI VOCAL (eXtended Imaging Virtual Organ Computer-aided Analysis). MATERIAIS E MÉTODOS: Realizou-se estudo de corte transversal com 70 gestantes normais entre 7 e 10 semanas e 6 dias. Para o cálculo de volume, utilizou-se o método XI VOCAL com delimitação de dez planos adjacentes. Foram determinadas médias, medianas, desvios-padrão, valores máximo e mínimo para o volume da placenta. Para avaliar a correlação do volume da placenta com a idade gestacional, foi criado gráfico de dispersão, sendo o ajuste realizado pelo coeficiente de determinação (R²). RESULTADOS: A média do volume da placenta variou de 4,6 cm³ (2,6-8,6 cm³) a 28,9 cm³ (11,4-66,9 cm³). O volume da placenta (VP) se mostrou altamente correlacionado com a idade gestacional (IG), sendo o melhor ajuste com a regressão exponencial [VP = exp(0,582 × IG + 0,063); R² = 0,82]. CONCLUSÃO: Valores de referência para o volume da placenta no primeiro trimestre de gestação utilizando o método XI VOCAL foram determinados.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a reprodutibilidade interobservador dos índices de vascularização do Doppler de amplitude tridimensional (Doppler de amplitude 3D) no primeiro trimestre de gestação. MATERIAIS E MÉTODOS: Realizou-se estudo de reprodutibilidade com 32 gestantes normais entre 7 e 10 semanas e 6 dias. Para o cálculo do volume tridimensional dos embriões utilizou-se o método VOCAL (Virtual Organ Computer-aided AnaLysis) com ângulo de rotação de 12°. Em seguida obtiveram-se, automaticamente, os três índices vasculares do Doppler de amplitude 3D: índice de vascularização (VI), índice de fluxo (FI) e índice de vascularização e fluxo (VFI). Para o cálculo da variabilidade interobservador, um examinador realizou uma segunda medida dos 32 embriões e um segundo examinador realizou uma terceira medida dos mesmos volumes, ambos desconhecendo os resultados do outro. Utilizaram-se, para análise estatística, o coeficiente de correlação intraclasse (CCI) e gráficos de Bland-Altman. RESULTADOS: Observou-se boa reprodutibilidade interobservador dos três índices vasculares. O VI apresentou CCI = 0,9 e média da diferença = -1,1; o FI apresentou CCI = 0,9 e média da diferença = -0,5; e o VFI apresentou CCI = 0,9 e média da diferença = -1,1. CONCLUSÃO: Os índices vasculares do Doppler de amplitude 3D do embrião no primeiro trimestre de gestação foram altamente reprodutíveis, em especial o FI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a reprodutibilidade do volume do braço e coxa fetais aferido pela ultrassonografia tridimensional utilizando o método eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL). MATERIAIS E MÉTODOS: Realizou-se estudo de reprodutibilidade com 43 fetos normais entre 20 e 37 semanas. Para o cálculo do volume do braço e coxa fetais utilizou-se o método XI VOCAL com delimitação de 10 planos consecutivos. Para o cálculo da variabilidade interobservador, um examinador realizou uma medida do volume do braço e coxa dos 43 fetos, enquanto um segundo examinador, sem o conhecimento prévio dos resultados do primeiro examinador, realizou uma segunda medida dos mesmos volumes. Utilizaram-se, para os cálculos estatísticos, o coeficiente de correlação intraclasse (ricc), gráficos de Bland-Altman e teste t-Student pareado (p). RESULTADOS: Observou-se alta reprodutibilidade interobservador. Para o volume do braço, obtiveram-se ricc = 0,996 (intervalo de confiança [IC] 95%: 0,992; 0,998) e média das diferenças = 0,13 ± 1,29% (95% limites de concordância: -2,54; +2,54%). Para o volume da coxa, obtiveram-se ricc = 0,997 (IC 95%: 0,995; 0,999) e média das diferenças = 0,24 ± 7,60% (95% limites de concordância: -7,6; +7,6%). CONCLUSÃO: O volume do braço e coxa fetais aferido pela ultrassonografia tridimensional utilizando o método XI VOCAL apresentou elevada reprodutibilidade interobservador.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a reprodutibilidade intra e interobservador do Doppler de amplitude tridimensional (3D power Doppler) na avaliação do fluxo sanguíneo cerebral do território da artéria cerebral média. MATERIAIS E MÉTODOS: Foi realizado estudo transversal com 20 gestantes normais entre 26 e 34 semanas. O território da artéria cerebral média mais próximo ao transdutor foi selecionado e o volume foi calculado utilizando-se o método Virtual Organ Computer-aided AnaLysis. Posteriormente, obtiveram-se os índices do 3D power Doppler: índice de vascularização (VI), índice de fluxo (FI) e índice de vascularização-fluxo (VFI). Utilizaram-se, para os cálculos, o coeficiente de correlação intraclasse (CCI) e gráficos de Bland-Altman. RESULTADOS: Foi observada boa concordância intra e interobservador, com CCI > 0,90 para todos os índices do 3D power Doppler: VI [CCI = 0,992 (IC 95%: 0,981-0,997)], FI [CCI = 0,999 (IC 95%: 0,998-0,999)], VFI [CCI = 0,995 (IC 95%: 0,987-0,998)]. Reprodutibilidade interobservador: VI [CCI = 0,988 (IC 95%: 0,970-0,995)], FI [CCI = 0,999 (IC 95%: 0,997-1,000)], VFI [CCI = 0,994 (IC 95%: 0,994-0,998)]. CONCLUSÃO: O 3D power Doppler mostrou-se um método prático, fácil e com boa reprodutibilidade intra e interobservador, com o IF evidenciando a melhor concordância intra e interobservador