931 resultados para Speech Intelligibility


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Audiometry is the main way with which hearing is evaluated, because it is a universal and standardized test. Speech tests are difficult to standardize due to the variables involved, their performance in the presence of competitive noise is of great importance. Aim: To characterize speech intelligibility in silence and in competitive noise from individuals exposed to electronically amplified music. Material and Method: It was performed with 20 university students who presented normal hearing thresholds. The speech recognition rate (SRR) was performed after fourteen hours of sound rest after the exposure to electronically amplified music and once again after sound rest, being studied in three stages: without competitive noise, in the presence of Babble-type competitive noise, in monotic listening, in signal/ noise ratio of + 5 dB and with the signal/ noise ratio of 5 dB. Results: There was greater damage in the SRR after exposure to the music and with competitive noise, and as the signal/ noise ratio decreases, the performance of individuals in the test also decreased. Conclusion: The inclusion of competitive noise in the speech tests in the audiological routine is important, because it represents the real disadvantage experienced by individuals in daily listening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluates the Speech Intelligibility Index (SII) as a tool to describe hearing loss and predict when hearing aids would be appropriate for pediatric oncology patients who have received or are currently receiving cisplatin. The efficacy of the SII is compared to the Brock grade which is commonly used for patients with ototoxic hearing loss secondary to cisplatin treatment. The SII is a discrete measure that precisely reflects the patient’s functional hearing status and is highly correlated with the need for audiologic intervention.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This dissertation examines the frequency response that results in the maximum level of speech intelligibility for persons with noise-induced hearing loss.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reviews a study to validate a speech intelligibility measure for profoundly deaf children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper was a study to examine the effect of bandlimiting on speech intelligibility.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When speech is in competition with interfering sources in rooms, monaural indicators of intelligibility fail to take account of the listener’s abilities to separate target speech from interfering sounds using the binaural system. In order to incorporate these segregation abilities and their susceptibility to reverberation, Lavandier and Culling [J. Acoust. Soc. Am. 127, 387–399 (2010)] proposed a model which combines effects of better-ear listening and binaural unmasking. A computationally efficient version of this model is evaluated here under more realistic conditions that include head shadow, multiple stationary noise sources, and real-room acoustics. Three experiments are presented in which speech reception thresholds were measured in the presence of one to three interferers using real-room listening over headphones, simulated by convolving anechoic stimuli with binaural room impulse-responses measured with dummy-head transducers in five rooms. Without fitting any parameter of the model, there was close correspondence between measured and predicted differences in threshold across all tested conditions. The model’s components of better-ear listening and binaural unmasking were validated both in isolation and in combination. The computational efficiency of this prediction method allows the generation of complex “intelligibility maps” from room designs. © 2012 Acoustical Society of America

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to determine the influence of hearing protection devices (HPDs) on the understanding of speech in young adults with normal hearing, both in a silent situation and in the presence of ambient noise. The experimental research was carried out with the following variables: five different conditions of HPD use (without protectors, with two earplugs and with two earmuffs); a type of noise (pink noise); 4 test levels (60, 70, 80 and 90 dB[A]); 6 signal/noise ratios (without noise, + 5, + 10, zero, - 5 and - 10 dB); 5 repetitions for each case, totalling 600 tests with 10 monosyllables in each one. The variable measure was the percentage of correctly heard words (monosyllabic) in the test. The results revealed that, at the lowest levels (60 and 70 dB), the protectors reduced the intelligibility of speech (compared to the tests without protectors) while, in the presence of ambient noise levels of 80 and 90 dB and unfavourable signal/noise ratios (0, -5 and -10 dB), the HPDs improved the intelligibility. A comparison of the effectiveness of earplugs versus earmuffs showed that the former offer greater efficiency in respect to the recognition of speech, providing a 30% improvement over situations in which no protection is used. As might be expected, this study confirmed that the protectors' influence on speech intelligibility is related directly to the spectral curve of the protector's attenuation. (C) 2003 Elsevier B.V. Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: In the Swiss version of the Freiburg speech intelligibility test five test words from the original German recording which are rarely used in Switzerland have been exchanged. Furthermore, differences in the transfer functions between headphone and loudspeaker presentation are not taken into account during calibration. New settings for the levels of the individual test words in the recommended recording and small changes in calibration procedures led us to make a verification of the currently used normative values.PATIENTS AND METHODS: Speech intelligibility was measured in 20 subjects with normal hearing using monosyllabic words and numbers via headphones and loudspeakers.RESULTS: On average, 50% speech intelligibility was reached at levels which were 7.5 dB lower under free-field conditions than for headphone presentation. The average difference between numbers and monosyllabic words was found to be 9.6 dB, which is considerably lower than the 14 dB of the current normative curves.CONCLUSIONS: There is a good agreement between our measurements and the normative values for tests using monosyllabic words and headphones, but not for numbers or free-field measurements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION The Rondo is a single-unit cochlear implant (CI) audio processor comprising the identical components as its behind-the-ear predecessor, the Opus 2. An interchange of the Opus 2 with the Rondo leads to a shift of the microphone position toward the back of the head. This study aimed to investigate the influence of the Rondo wearing position on speech intelligibility in noise. METHODS Speech intelligibility in noise was measured in 4 spatial configurations with 12 experienced CI users using the German adaptive Oldenburg sentence test. A physical model and a numerical model were used to enable a comparison of the observations. RESULTS No statistically significant differences of the speech intelligibility were found in the situations in which the signal came from the front and the noise came from the frontal, ipsilateral, or contralateral side. The signal-to-noise ratio (SNR) was significantly better with the Opus 2 in the case with the noise presented from the back (4.4 dB, p < 0.001). The differences in the SNR were significantly worse with the Rondo processors placed further behind the ear than closer to the ear. CONCLUSION The study indicates that CI users with the receiver/stimulator implanted in positions further behind the ear are expected to have higher difficulties in noisy situations when wearing the single-unit audio processor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the speech intelligibility in noise with a new cochlear implant (CI) processor that uses a pinna effect imitating directional microphone system. STUDY DESIGN Prospective experimental study. SETTING Tertiary referral center. PATIENTS Ten experienced, unilateral CI recipients with bilateral severe-to-profound hearing loss. INTERVENTION All participants performed speech in noise tests with the Opus 2 processor (omnidirectional microphone mode only) and the newer Sonnet processor (omnidirectional and directional microphone mode). MAIN OUTCOME MEASURE The speech reception threshold (SRT) in noise was measured in four spatial settings. The test sentences were always presented from the front. The noise was arriving either from the front (S0N0), the ipsilateral side of the CI (S0NIL), the contralateral side of the CI (S0NCL), or the back (S0N180). RESULTS The directional mode improved the SRTs by 3.6 dB (p < 0.01), 2.2 dB (p < 0.01), and 1.3 dB (p < 0.05) in the S0N180, S0NIL, and S0NCL situations, when compared with the Sonnet in the omnidirectional mode. There was no statistically significant difference in the S0N0 situation. No differences between the Opus 2 and the Sonnet in the omnidirectional mode were observed. CONCLUSION Speech intelligibility with the Sonnet system was statistically different to speech recognition with the Opus 2 system suggesting that CI users might profit from the pinna effect imitating directionality mode in noisy environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effects of posteroventral pallidotomy on perceptual and physiological measures of articulatory function and speech intelligibility in Parkinson disease (M). The study examined 11 participants with M who underwent posteroventral pallidotomy Physiological measures of hp and tongue function. and perceptual measures of speech intelligibility were obtained prepallidotomy and 3 months postpallidotomy. The participants with PD were also assessed on the Unified Parkinsons Disease Rating Scale (UPDRS Part III) In addition, the study included a group of 16 participants with PD who did not undergo pallidotomy and a group of 30 nonneurologically impaired participants. Analyses of physiological articulatory function and speech intelligibility did not reveal corresponding improvements in motor speech function as observed in general limb motor function postpallidotomy. Overall, individual reliable change analyses revealed that the majority of surgical PD participants demonstrated no reliable change on perceptual and physiological measures of articulation. The cur rent study revealed preliminary evidence that articulatury function and speech intelligibility did not change following posteroventral pallidotomy in a group of individuals with PD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An important aspect of speech perception is the ability to group or select formants using cues in the acoustic source characteristics-for example, fundamental frequency (F0) differences between formants promote their segregation. This study explored the role of more radical differences in source characteristics. Three-formant (F1+F2+F3) synthetic speech analogues were derived from natural sentences. In Experiment 1, F1+F3 were generated by passing a harmonic glottal source (F0 = 140 Hz) through second-order resonators (H1+H3); in Experiment 2, F1+F3 were tonal (sine-wave) analogues (T1+T3). F2 could take either form (H2 or T2). In some conditions, the target formants were presented alone, either monaurally or dichotically (left ear = F1+F3; right ear = F2). In others, they were accompanied by a competitor for F2 (F1+F2C+F3; F2), which listeners must reject to optimize recognition. Competitors (H2C or T2C) were created using the time-reversed frequency and amplitude contours of F2. Dichotic presentation of F2 and F2C ensured that the impact of the competitor arose primarily through informational masking. In the absence of F2C, the effect of a source mismatch between F1+F3 and F2 was relatively modest. When F2C was present, intelligibility was lowest when F2 was tonal and F2C was harmonic, irrespective of which type matched F1+F3. This finding suggests that source type and context, rather than similarity, govern the phonetic contribution of a formant. It is proposed that wideband harmonic analogues are more effective informational maskers than narrowband tonal analogues, and so become dominant in across-frequency integration of phonetic information when placed in competition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The role of source properties in across-formant integration was explored using three-formant (F1+F2+F3) analogues of natural sentences (targets). In experiment 1, F1+F3 were harmonic analogues (H1+H3) generated using a monotonous buzz source and second-order resonators; in experiment 2, F1+F3 were tonal analogues (T1+T3). F2 could take either form (H2 or T2). Target formants were always presented monaurally; the receiving ear was assigned randomly on each trial. In some conditions, only the target was present; in others, a competitor for F2 (F2C) was presented contralaterally. Buzz-excited or tonal competitors were created using the time-reversed frequency and amplitude contours of F2. Listeners must reject F2C to optimize keyword recognition. Whether or not a competitor was present, there was no effect of source mismatch between F1+F3 and F2. The impact of adding F2C was modest when it was tonal but large when it was harmonic, irrespective of whether F2C matched F1+F3. This pattern was maintained when harmonic and tonal counterparts were loudness-matched (experiment 3). Source type and competition, rather than acoustic similarity, governed the phonetic contribution of a formant. Contrary to earlier research using dichotic targets, requiring across-ear integration to optimize intelligibility, H2C was an equally effective informational masker for H2 as for T2.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The recent developments on Hidden Markov Models (HMM) based speech synthesis showed that this is a promising technology fully capable of competing with other established techniques. However some issues still lack a solution. Several authors report an over-smoothing phenomenon on both time and frequencies which decreases naturalness and sometimes intelligibility. In this work we present a new vowel intelligibility enhancement algorithm that uses a discrete Kalman filter (DKF) for tracking frame based parameters. The inter-frame correlations are modelled by an autoregressive structure which provides an underlying time frame dependency and can improve time-frequency resolution. The system’s performance has been evaluated using objective and subjective tests and the proposed methodology has led to improved results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper examines the effect of amplification bandwidth on speech intelligibility using multiple speech samples.