950 resultados para SUPPLEMENTAL INTRAOSSEOUS INJECTION


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. We compared the anesthetic efficacy of inferior alveolar nerve block (IANB) plus buccal infiltration (BI) and IANB plus periodontal ligament (PDL) articaine injections in patients with irreversible pulpitis in the mandibular first molar. Study design. Fifty-seven volunteers, patients with irreversible pulpitis in the mandibular first molar admitted to the Department of Stomatology, Second Affiliated Hospital, Sun Yat-Sen University, randomly received conventional IANB, containing 1.7 mL 4% articaine/HCl with 1:100,000 epinephrine, plus either BI or PDL injections containing 0.4 mL articaine/HCl with 1: 100,000 epinephrine. The patients recorded the pain of the injections and endodontic access on a Heft-Parker visual analog scale (VAS). Results. According to the VAS scores, all patients experienced no or mild pain with BI and PDL injections after the application of IANB. Anesthetic success occurred in 81.48% for IANB plus BI (IANB/BI) compared with 83.33% for IANB plus PDL injection (IANB/PDL injection). None of the observed differences between the 2 groups was significant (P > .05). Conclusion. Both injection combinations resulted in high anesthetic success in patients with irreversible pulpitis in the mandibular first molar. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;108:e89-e93)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to compare the anesthetic efficacy of 0.5% bupivacaine with 1:200,000 epinephrine with that of 2% lidocaine with 1:100,000 epinephrine during pulpectomy in patients with irreversible pulpitis in mandibular posterior teeth. Methods: Seventy volunteers, patients with irreversible pulpitis admitted to the Emergency Center of the School of Dentistry at the University of Sao Paulo, randomly received a conventional inferior alveolar nerve block containing 3.6 mL of either 0.5% bupivacaine with 1:200,000 epinephrine or 2% lidocaine with 1:100,000 epinephrine. During the subsequent pulpectomy, we recorded the patients subjective assessments of lip anesthesia, the absence/presence of pulpal anesthesia through electric pulp stimulation, and the absence/presence of pain through a verbal analog scale. Results: All patients reported lip anesthesia after the application of either inferior alveolar nerve block. By measuring pulpal anesthesia success with the pulp tester, lidocaine had a higher success rate (42.9%) than bupivacaine (20%). For patients reporting none or mild pain during pulpectomy, the success rate of bupivacaine was 80% and lidocaine was 62.9%. There were only statistically significant differences to the success of pulpal anesthesia. Conclusions: Neither of the solutions resulted in an effective pain control during irreversible pulpitis treatments of mandibular molars. (J Endod 2012;38:594-597)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the effect of the first and repeated intravitreal injections of ranibizumab (1.25mg; 0.05ml) on retrobulbar blood flow velocities in patients with wet age-related macular degeneration (AMD). Methods: This prospective non randomized study included twenty consecutive AMD patients. Time- averaged mean blood flow velocities (BFVs) in the central retinal, temporal posterior ciliary and ophthalmic arteries (CRA, TPCA and OA) were measured by ultrasound imaging before, 2 days and 3 weeks after the first injection of ranibizumab, then 6 months after supplemental monthly injections if required. At each visit, complete ophthalmological examination was performed, including best corrected visual acuity measurement according to ETDRS protocol and OCT. Results: In the treated eyes, ranibizumab injection was followed by a significant improvement in visual acuity (from 44.4 ± 21.7, to 50.9±25.9 (p<0.01) at month 6, and a decrease in mean central macular thickness from 377±115 to 267 ± 74 µm (p<0.001) at month 6. At day 2 mean BFVs decreased by 16% in the CRA and by 20% in TPCA (p<0.001, both), then remained stable. Mean BFVs did not change in OA at the day 2 but decreased at week 3 by 18% (p<0.001). Supplemental injections did not lead to additional effects at month 6. No effect was tabulated in the fellow eye. Conclusions: We report an early decrease in mean BFV in CRA and TPRA following intravitreal injections of ranibizumab corresponding to vasoconstrictive effect of this drug. Decrease in mean BFV in all retrobulbar arteries from the week 3 suggests that ranibizumab proceeds to a local and regional vasoconstrictive and antiangiogenic effects after local diffusion. Thus, ranibizumab could induce an actual hypoperfusion of the treated eye which could correspond to a vascular side effect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Forty Hampshire and 40 Suffolk ewes were allotted to one of four groups (VitA, VitE, VitA&E, Control) in a 2 x 2 factorial treatment arrangement to evaluate the effect of supplemental vitamin E (0 or 300 IU) and vitamin A (0 or 250,000 IU) on reproductive performance. Laparoscopy and ultrasonography were used to measure ovulation rate, embryonic loss, and fetal loss. Serum profiles of a-tocopherol (vitamin E) and retinol (vitamin A) also were monitored. There were no differences (P>.05) among treatment groups in any reproductive trait. Suffolk ewes exhibited a higher (P<.02) ovulation rate than Hampshire ewes, and yearling ewes incurred higher (P<.001) embryonic loss than other age groups, resulting in a lower (P<.001) litter size. Serum levels of a-tocopherol were higher (P<.05) for Hampshire than for Suffolk ewes and were lower (P<.001) in yearling ewes versus ewes two years of age and older. Serum levels of a-tocopherol declined (P<.01) throughout the study in VitA and Control ewes but remained unchanged in VitE and VitA&E ewes. Serum level of retinol remained unchanged in VitA ewes, whereas the level increased (P<.01) initially in VitE, VitA&E, and Control ewes before declining toward initial levels. Correlations were detected between ovulation rate and the change of pre-mating a-tocopherol serum level (r=-.29; P<.02), the change in pre-mating retinol serum level (r=-.50; P<.02) and the interval from vitamin A injection (r=-.60; P<.05). These data indicate significant influences of breed, age, and treatment on a-tocopherol and retinol serum levels in ewes and suggest that the timing of vitamin A administration may influence ovulation rate; however, vitamin supplementation, administered at random stages of the estrous cycle, was unable to alter flock reproductive performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation limit is about 3×10--4 mol L-1 and approximately 30 determinations can be performed in an hour. The results were compared with those obtained with a reference HPLC method. Statistical comparisons were done using the Student's t procedure and the F test. Complete agreement was found at the 0.95 significance level between the proposed flow injection and the HPLC procedures. The two methods present similar precision, i.e., for HPLC the mean relative standard deviation was ca. 1.2% and for FIA ca. 1.6%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the development and evaluation of a hyphenated flow injection-capillary electrophoresis system with on-line pre-concentration is described. Preliminary tests were performed to investigate the influence of flow rates over the analytical signals. Results revealed losses in terms of sensitivity of the FIA-CE system when compared to the conventional CE system. To overcome signal decrease and to make the system more efficient, a lower flow rate was set and an anionic resin column was added to the flow manifold in order to pre-concentrate the analyte. The pre-concentration FIA-CE system presented a sensitivity improvement of about 660% and there was only a small increase of 8% in total peak dispersion. These results have confirmed the great potential of the proposed system for many analytical tasks especially for low concentration samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a sequential injection chromatography procedure for determination of picloram in waters exploring the low backpressure of a 2.5 cm long monolithic C18 column. Separation of the analyte from the matrix was achieved in less than 60 s using a mobile phase composed by 20:80 (v v-1) acetonitrile:5.0 mmol L-1 H3PO4 and flow rate of 30 μL s-1. Detection was made at 223 nm with a 40 mm optical path length cell. The limits of detection and quantification were 33 and 137 μg L-1, respectively. The proposed method is sensitive enough to monitor the maximum concentration level for picloram in drinking water (500 μg L-1). The sampling frequency is 60 analyses per hour, consuming only 300 μL of acetonitrile per analysis. The proposed methodology was applied to spiked river water samples and no statistically significant differences were observed in comparison to a conventional HPLC-UV method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes a photo-reactor to perform in line degradation of organic compounds by photo-Fenton reaction using Sequential Injection Analysis (SIA) system. A copper phthalocyanine-3,4',4²,4²¢-tetrasulfonic acid tetrasodium salt dye solution was used as a model compound for the phthalocyanine family, whose pigments have a large use in automotive coatings industry. Based on preliminary tests, 97% of color removal was obtained from a solution containing 20 µmol L-1 of this dye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cell therapy approaches for biologic cardiac repair hold great promises, although basic fundamental issues remain poorly understood. In the present study we examined the effects of timing and routes of administration of bone marrow cells (BMC) post-myocardial infarction (MI) and the efficacy of an injectable biopolymer scaffold to improve cardiac cell retention and function. Methodology/Principal Findings: (99m)Tc-labeled BMC (6x10(6) cells) were injected by 4 different routes in adult rats: intravenous (IV), left ventricular cavity (LV), left ventricular cavity with temporal aorta occlusion (LV(+)) to mimic coronary injection, and intramyocardial (IM). The injections were performed 1, 2, 3, or 7 days post-MI and cell retention was estimated by gamma-emission counting of the organs excised 24 hs after cell injection. IM injection improved cell retention and attenuated cardiac dysfunction, whereas IV, LV or LV* routes were somewhat inefficient (< 1%). Cardiac BMC retention was not influenced by timing except for the IM injection that showed greater cell retention at 7 (16%) vs. 1, 2 or 3 (average of 7%) days post-MI. Cardiac cell retention was further improved by an injectable fibrin scaffold at day 3 post-MI (17 vs. 7%), even though morphometric and function parameters evaluated 4 weeks later displayed similar improvements. Conclusions/Significance: These results show that cells injected post-MI display comparable tissue distribution profile regardless of the route of injection and that there is no time effect for cardiac cell accumulation for injections performed 1 to 3 days post-MI. As expected the IM injection is the most efficient for cardiac cell retention, it can be further improved by co-injection with a fibrin scaffold and it significantly attenuates cardiac dysfunction evaluated 4 weeks post myocardial infarction. These pharmacokinetic data obtained under similar experimental conditions are essential for further development of these novel approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the coupling of a biomimetic sensor to a flow injection system for the sensitive determination of paracetamol. The sensor was prepared as previously described in the literature (M. D. P. T. Sotomayor, A. Sigoli, M. R. V. Lanza, A. A. Tanaka and L. T. Kubota, J. Braz. Chem. Soc., 2008, 19, 734) by modifying a glassy carbon electrode surface with a Nafion (R) membrane doped with iron tetrapyridinoporphyrazine (FeTPyPz), a biomimetic catalyst of the P450 enzyme. The performance of the sensor for paracetamol detection was investigated and optimized in a flow injection system (FIA) using a wall jet electrochemical cell. Under optimized conditions a wide linear response range (1.0 x 10(-5) to 5.0 x 10(-2) mol L(-1)) was obtained, with a sensitivity of 2579 (+/- 129) mu A L mu mol(-1). The detection and quantification limits of the sensor for paracetamol in the FIA system were 1.0 and 3.5 mu mol L(-1), respectively. The analytical frequency was 51 samples h(-1), and over a period of five days (320 determinations) the biosensor maintained practically the same response. The system was successfully applied to paracetamol quantification in seven pharmaceutical formulations and in water samples from six rivers in Sao Paulo State, Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow system designed with solenoid micro-pumps is proposed for fast and greener spectrophotometric determination of free glycerol in biodiesel. Glycerol was extracted from samples without using organic solvents. The determination involves glycerol oxidation by periodate, yielding formaldehyde followed by formation of the colored (3,5-diacetil-1,4-dihidrolutidine) product upon reaction with acetylacetone. The coefficient of variation, sampling rate and detection limit were estimated as 1.5% (20.0 mg L(-1) glycerol, n =10), 34 h(-1), and 1.0 mg L(-1) (99.7% confidence level), respectively. A linear response was observed from 5 to 50 mg L(-1), with reagent consumption estimated as 345 mu g of KIO(4) and 15 mg of acetylacetone per determination. The procedure was successfully applied to the analysis of biodiesel samples and the results agreed with the batch reference method at the 95% confidence level. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a downscaled multicommuted flow injection analysis setup for photometric determination is described. The setup consists of a flow system module and a LED based photometer, with a total internal volume of about 170 mu L The system was tested by developing an analytical procedure for the photometric determination of iodate in table salt using N,N-diethyl-henylenediamine (DPD) as the chromogenic reagent. Accuracy was accessed by applying the paired r-test between results obtained using the proposed procedure and a reference method, and no significant difference at the 95% confidence level was observed. Other profitable features, such as a low reagent consumption of 7.3 mu g DPD per determination: a linear response ranging from 0.1 up to 3.0 m IO(3)(-), a relative standard deviation of 0.9% (n = 11) for samples containing 0.5 m IO(3)(-), a detection limit of 17 mu g L(-1) IO(3)(-), a sampling throughput of 117 determination per hour, and a waste generation 600 mu L per determination, were also achieved. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analytical procedure for multiple standard additions of arsenic species using sequential injection analysis (SIA) is proposed for their quantification in seafood extracts. SIA presented flexibility for generating multiple specie standards at the ng mL(-1) concentration level by adding different volumes of As(III), As(V), monomethylarsonic (MMA) and dimethylarsinic (DMA) to the sample. The mixed sample plus standard solutions were delivered from SIA to fill the HPLC injection loop. Subsequently, As species were separated by HPLC and analyzed by atomic fluorescence spectrometry (AFS). The proposed system comprised two independently controlled modules, with the HPLC loop acting as the intermediary device. The analytical frequency was enhanced by combining the actions of both modules. While the added sample was flowing through the chromatographic column towards the detection system, the SIA program started performing the standard additions to another sample. The proposed method was applied to spoiled seafood extracts. Detection limits based on 3 sigma for As(III), As(V), MMA and DMA were 0.023, 0.39, 0.45 and 1.0 ng mL(-1), respectively. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel flow-based strategy for implementing simultaneous determinations of different chemical species reacting with the same reagent(s) at different rates is proposed and applied to the spectrophotometric catalytic determination of iron and vanadium in Fe-V alloys. The method relies on the influence of Fe(II) and V(IV) on the rate of the iodide oxidation by Cr(VI) under acidic conditions, the Jones reducing agent is then needed Three different plugs of the sample are sequentially inserted into an acidic KI reagent carrier stream, and a confluent Cr(VI) solution is added downstream Overlap between the inserted plugs leads to a complex sample zone with several regions of maximal and minimal absorbance values. Measurements performed on these regions reveal the different degrees of reaction development and tend to be more precise Data are treated by multivariate calibration involving the PLS algorithm The proposed system is very simple and rugged Two latent variables carried out ca 95% of the analytical information and the results are in agreement with ICP-OES. (C) 2010 Elsevier B V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and reliable method for Hg determination in fish samples has been developed. Lyophilised fish tissue samples were extracted in a 25% (w/v) tetramethylammonium hydroxide (TMAH) solution; the extracts were then analysed by FI-CVAFS. This method can be used to determine total and inorganic Hg, using the same FI manifold. For total Hg determination, a 0.1% (w/v) KMnO(4) solution was added to the FI manifold at the sample zone, followed by the addition of a 0.5% (w/v) SnCl(2) solution, whereas inorganic Hg was determined by adding a 0.1% (w/v) L-cysteine solution followed by a 1.0% (w/v) SnCl(2) solution to the FI system. The organic fraction was determined as the difference between total and inorganic Hg. Sample preparation, reagent consumption and parameters that can influence the FI-CVAFS performance were also evaluated. The limit of detection for this method is 3.7 ng g(-1) for total Hg and 4.3 ng g(-1) for inorganic Hg. The relative standard deviation for a 1.0 mu gL(-1) CH(3)Hg standard solution (n = 20) was 1.1%, and 1.3% for a 1.0 mu gL(-1) Hg(2+) standard solution (n = 20). Accuracy was assessed by the analysis of Certified Reference Material (dogfish: DORM-2, NRCC). Recoveries of 99.1% for total Hg and 93.9% inorganic Hg were obtained. Mercury losses were not observed when sample solutions were re-analysed after a seven day period of storage at 4 degrees C.