994 resultados para STANDARD BASE EXCESS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the impact of acute PaCO(2) temporal variation on the standard base excess (SBE) value in critically ill patients. Methods: A total of 265 patients were prospectively observed; 158 were allocated to the modeling group, and 107 were allocated to the validation group. Two models were developed in the modeling group (one including and one excluding PaCO(2) as a variable determinant of SBE), and both were tested in the validation group. Results: In the modeling group, the mathematical model including SIDai, SIG, L-lactate, albumin, phosphate, and PaCO(2) had a predictive superiority in comparison with the model without PaCO(2) (R(2) = 0.978 and 0.916, respectively). In the validation group, the results were confirmed with significant F change statistics (R(2) change = 0.059, P < .001) between the model with and without PaCO(2). A high correlation (R = 0.99, P < .001) and agreement (bias = -0.25 mEq/L, limits of agreement 95% = -0.72 to 0.22 mEq/L) were found between the model-predicted SBE value and the SBE calculated using the Van Slyke equation. Conclusions: Acute PaCO(2), temporal variation is related to SBE changes in critically ill patients. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aims of this study were to determine whether standard base excess (SBE) is a useful diagnostic tool for metabolic acidosis, whether metabolic acidosis is clinically relevant in daily evaluation of critically ill patients, and to identify the most robust acid-base determinants of SBE. Thirty-one critically ill patients were enrolled. Arterial blood samples were drawn at admission and 24 h later. SBE, as calculated by Van Slyke's (SBE VS) or Wooten's (SBE W) equations, accurately diagnosed metabolic acidosis (AUC = 0.867, 95%CI = 0.690-1.043 and AUC = 0.817, 95%CI = 0.634-0.999, respectively). SBE VS was weakly correlated with total SOFA (r = -0.454, P < 0.001) and was similar to SBE W (r = -0.482, P < 0.001). All acid-base variables were categorized as SBE VS <-2 mEq/L or SBE VS <-5 mEq/L. SBE VS <-2 mEq/L was better able to identify strong ion gap acidosis than SBE VS <-5 mEq/L; there were no significant differences regarding other variables. To demonstrate unmeasured anions, anion gap (AG) corrected for albumin (AG A) was superior to AG corrected for albumin and phosphate (AG A+P) when strong ion gap was used as the standard method. Mathematical modeling showed that albumin level, apparent strong ion difference, AG A, and lactate concentration explained SBE VS variations with an R² = 0.954. SBE VS with a cut-off value of <-2 mEq/L was the best tool to diagnose clinically relevant metabolic acidosis. To analyze the components of SBE VS shifts at the bedside, AG A, apparent strong ion difference, albumin level, and lactate concentration are easily measurable variables that best represent the partitioning of acid-base derangements.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: La hemorragia digestiva (HVDA) es la principal causa de descompensación en pacientes con cirrosis. Caracterizar el estado ácido-base de estos pacientes sería útil para reflejar la severidad del sangrado e identificar pacientes con alto riesgo de complicación. Objetivo: Describir el estado ácido-base de los pacientes que consultaron a urgencias con cirrosis descompensada por HVDA y posteriormente fueron manejados en la unidad de cuidado intensivo (UCI) o fallecieron. Métodos: Se realizó el análisis del estado ácido-base a 10 pacientes con estas características, utilizando tres métodos distintos. Resultados: El perfil ácido-base encontrado fue: acidosis metabólica por iones no medidos, acidosis láctica, alcalosis por hipoalbuminemia y anión gap elevado en la mayoría de pacientes. Conclusiones: La teoría de Henderson-Hasselbach no fue suficiente para identificar pacientes con alto riesgo, debería implementarse concomitantemente el análisis anión gap, base déficit y el método físico–químico, para entender los fenómenos acido base de estos pacientes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To determine the effects of storage of arterial and venous blood samples in ice water on blood gas and acid-base measurements.Design: Prospective, in vitro, laboratory study.Setting: School of veterinary medicine.Subjects: Six healthy dogs.Measurements and main results: Baseline measurements of partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), pH, hemoglobin concentration (tHb), oxyhemoglobin saturation, and oxygen content (ContO(2)) were made. Bicarbonate (HCO3) and standard base excess (SBE) were calculated. Arterial and venous blood samples were separated into 1 and 3 mL samples, anaerobically transferred into 3 mL plastic syringes, and stored in ice water for 6 hours. Measurements were repeated at 15, 30 minutes, and 1, 2, 4, and 6 hours after baseline measurements. Arterial (a) PO2 increased significantly from baseline after 30 minutes of storage in the 1 mL samples and after 2 hours in the 3 mL samples. Venous (v) PO2 was significantly increased from baseline after 4 hours in the 1 mL samples and after 6 hours in the 3 mL samples. The pHa significantly decreased after 2 hours of storage in the 1 mL samples and after 4 hours in the 3 mL samples. In both the 1 and 3 mL samples, pHv decreased significantly only after 6 hours. Neither the arterial nor the venous PCO2 values changed significantly in the 1 mL samples and increased only after 6 hours in the 3 mL samples. No significant changes in tHb, ContO(2), SBE, or HCO3 were detected.Conclusions: the PO2 of arterial and venous blood increased significantly when samples were stored in plastic syringes in ice water. These increases are attributable to the diffusion of oxygen from and through the plastic of the syringe into the blood, which occurred at a rate that exceeded metabolic consumption of oxygen by the nucleated cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Food base excess (BE, mEq/kg) can be calculated from the diet macroelements, together with either the sulfur amino acids methionine and cysteine (BEaa) or total sulfur (BEs) concentrations. The present study compared the use of sulfur or methionine and cysteine for calculating the food BE (experiment 1) and investigated the influence of food BE on blood gas analysis and the urine pH of cats, and proposes a prediction equation to estimate the urine pH of cats fed kibble diets based on the calculated food BE (experiments 2 and 3). In experiment 1, nine healthy, adult cats were used in a change-over design and fed with nine commercial dry cat foods. The cats were housed in metabolism cages over seven days for adaptation and three days for total urine collection. All of the urine produced over 24h was pooled by cat and diet. The cats' acid-base status was assessed through blood gas analysis after 10 days of diet consumption. A mean difference of -115mEq/kg between BEs and BEaa was observed, which could be explained by a greater concentration of sulfur in the whole diet than in methionine and cysteine. Urine pH presented a stronger correlation with food BEs (R2=0.95; P<0.001) than with food BEaa (R2=0.86; P<0.001). Experiment 2 included 30 kibble diets, and each diet was tested in six cats. The food BEs varied between -180 and +307mEq/kg, and the urine pH of the cats varied between 5.60 and 7.74. A significant correlation was found between the measured urine pH and the food BEs (urinary pH=6.269+[0.0036×BEs]+[0.000003×BEs2]; R2=0.91; P<0.001). In experiment 3, eight kibble diets were tested (food BEs between -187mEq/kg and +381mEq/kg) to validate the equation proposed in experiment 2 and to compare the obtained results with previously published formulae. The results of the proposed formula presented a high concordance correlation coefficient (0.942) and high accuracy (0.979) with the measured values, and the estimates of urine pH did not differ from the values obtained in cats (P>0.05). The cats' venous blood pH, bicarbonate, and blood BE were correlated with food BEs (P<0.001); the consumption of diets with low food BEs induced a reduction in these parameters. In conclusion, food macroelement composition has a strong influence on cats' acid-base equilibrium and food BEs calculation is a useful tool to formulate and balance kibble diets for felines. © 2013 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This study was designed to evaluate serum potassium level variation in a porcine model of hemorrhagic shock ( HS). Methods: Eight pigs were studied in a controlled hemorrhage model of HS. Blood withdrawal began at a 50 mL/min to 70 mL/min rate, adjusted to reach a mean arterial pressure ( MAP) level of 60 mm Hg in 10 minutes. When MAP reached 60 mm Hg, the blood withdrawal rate was adjusted to maintain a MAP decrease rate of 10 mm Hg every 2 minutes to 4 minutes. Arterial and mixed venous blood samples were collected at MAP levels of 60 mm Hg, 50 mm Hg, 40 mm Hg, 30 mm Hg, 20 mm Hg, and 10 mm Hg and analyzed for oxygen saturation, PO(2), PCO(2), potassium, lactate, bicarbonate, hemoglobin, pH, and standard base excess. Results: Significant increase in serum potassium occurred early in all animals. The rate of rise in serum potassium and its levels accompanied the hemodynamic deterioration. Hyperkalemia ( K >5 mmol/L) incidence was 12.5% at 60 mm Hg and 50 mm Hg, 62.5% at 40 mm Hg, 87.5% at 30 mm Hg, and 100% at 20 mm Hg. Strong correlations were found between potassium levels and lactate ( R = 0.82), SvO(2) ( R = 0.87), Delta pH ( R = 0.83), and Delta PCO(2) ( R = 0.82). Conclusions: Serum potassium increase accompanies the onset of HS. The rise in serum potassium was directly related to the hemodynamic deterioration of HS and strongly correlated with markers of tissue hypoxia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Inorganic apparent strong ion difference (SIDai) improves chloride-associated acidosis recognition in dysnatremic patients. We investigated whether the difference between sodium and chloride (Na+-C1-) or the ratio between chloride and sodium (Cl-/Na+) could be used as SIDai surrogates in mixed and dysnatremic patients. Patients and Methods: Two arterial blood samples were collected from 128 patients. Physicochemical analytical approach was used. Correlation, agreement, accuracy, sensitivity, and specificity were measured to examine whether Na(+)-C1(-) and CI(-)/Na(+) could be used instead of SIDai in the diagnosis of acidosis. Results: Na(+)-C1(-) and CF/Na+ were well correlated with SIDai (R = 0.987, P < 0.001 and R = 0.959, P < 0.001, respectively). Bias between Na(+)-C1(-) and SIDai was high (6.384 with a limit of agreement of 4.4638.305 mEq/L). Accuracy values for the identification of SIDai acidosis (<38.9 mEq/L) were 0.989 (95% confidence interval [CI], 0.980-0.998) for Na+-C1- and 0.974 (95% CI, 0.959-0.989) for Cr/Na+. Receiver operator characteristic curve showed that values revealing SIDai acidosis were less than 32.5 mEq/L for Nata- and more than 0.764 for C17Na+ with sensitivities of 94.0% and 92.0% and specificities of 97.0% and 90.0%, respectively. Nata- was a reliable S IDai surrogate in dysnatremic patients. Conclusions: Nata- and CI-/Na+ are good tools to disclose S IDai acidosis. In patients with dysnatremia, Nata- is an accurate tool to diagnose SIDai acidosis. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to characterize the first 48-hour evolution of metabolic acidosis of adult patients with diabetic ketoacidosis admitted to the intensive care unit. Materials and Methods: We studied 9 patients retrieved from our prospective collected database, using the physicochemical approach to acid-base disturbances. Results: Mean (SD) age was 34 (13) years; mean (SD) Acute Physiology and Chronic Health Evaluation II score was 16 (10); mean (SD) blood glucose level on admission was 480 (144) mg/dL; mean (SD) pH was 7.17 (0.18); and mean (SD) standard base excess was -16.8 (7.7) mEq/L. On admission, a great part of metabolic acidosis was attributed to unmeasured anions (strong ion gap [SIG], 20 +/- 10 mEq/L), with a wide range of strong ion difference (41 +/- 10 mEq/L). During the first 48 hours of treatment, 297 +/- 180 IU of insulin and 9240 +/- 6505 mL of fluids were used. Metabolic improvement was marked by the normalization of pH, partial correction of standard base excess, and a reduction of hyperglycemia. There was a significant improvement of SIG (7.6 +/- 6.2 mEq/L) and a worsening of strong ion difference acidosis (36 +/- 5 mEq/L) in the first 24 hours, with a trend toward recuperation between 24 and 48 hours (38 +/- 6 mEq/L). Conclusion: Initial metabolic acidosis was due to SIG, and the treatment was associated with a significant decrease of SIG with an elevation of serum chloride above the normal range. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated the recovery of cardiovascular function after transient cardiogenic shock. Cardiac tamponade was performed for 1 h and post-shock data were collected in 5 domestic large white female pigs (43 ± 5 kg) for 6 h. The control group (N = 5) was observed for 6 h after 1 h of resting. During 1 h of cardiac tamponade, experimental animals evolved a low perfusion status with a higher lactate level (8.0 ± 2.2 vs 1.9 ± 0.9 mEq/L), lower standard base excess (-7.3 ± 3.3 vs 2.0 ± 0.9 mEq/L), lower urinary output (0.9 ± 0.9 vs 3.0 ± 1.4 mL·kg-1·h-1), lower mixed venous saturation, higher ileum partial pressure of CO2-end tidal CO2 (EtCO2) gap and a lower cardiac index than the control group. Throughout the 6-h recovery phase after cardiac tamponade, tamponade animals developed significant tachycardia with preserved cardiac index, resulting in a lower left ventricular stroke work, suggesting possible myocardial dysfunction. Vascular dysfunction was present with persistent systemic hypotension as well as persistent pulmonary hypertension. In contrast, oliguria, hyperlactatemia and metabolic acidosis were corrected by the 6th hour. The inflammatory characteristics were an elevated core temperature and increased plasma levels of interleukin-6 in the tamponade group compared to the control group. We conclude that cardiovascular recovery after a transient and severe low flow systemic state was incomplete. Vascular dysfunction persisted up to 6 h after release of tamponade. These inflammatory characteristics may also indicate that inflammatory activation is a possible pathway involved in the pathogenesis of cardiogenic shock.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hyperchloremia is one of the multiple etiologies of metabolic acidosis in hemodialysis (HD) patients. The aim of the present study was to determine the influence of chloride dialysate on metabolic acidosis control in this population. We enrolled 30 patients in maintenance HD program with a standard base excess (SBE) ≤2 mEq/L and urine output of less than 100 mL/24 h. The patients underwent dialysis three times per week with a chloride dialysate concentration of 111 mEq/L for 4 weeks, and thereafter with a chloride dialysate concentration of 107 mEq/L for the next 4 weeks. Arterial blood was drawn immediately before the second dialysis session of the week at the end of each phase, and the Stewart physicochemical approach was applied. The strong ion gap (SIG) decreased (from 7.5 ± 2.0 to 6.2 ± 1.9 mEq/L, P = 0.006) and the standard base excess (SBE) increased after the use of 107 mEq/L chloride dialysate (from -6.64 ± 1.7 to -4.73 ± 1.9 mEq/L, P < 0.0001). ∆SBE was inversely correlated with ∆SIG during the phases of the study (Pearson r = -0.684, P < 0.0001) and there was no correlation with ∆chloride. When we applied the Stewart model, we demonstrated that the lower concentration of chloride dialysate interfered with the control of metabolic acidosis in HD patients, surprisingly, through the effect on unmeasured anions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCCION La hipotensión arterial por anestesia raquídea en embarazadas llevadas a cesárea es frecuente y deletérea para la madre y el feto, sin que a la fecha exista una herramienta clínicamente útil para predecirla. La variabilidad de la frecuencia cardiaca es una medida que estima la actividad del sistema nervioso autónomo y algunos estudio iniciales indican una posible utilidad como herramienta predictiva de hipotensión arterial en esta población. METODOLOGIA Se realizó un estudio observacional descriptivo para examinar el comportamiento de la variabilidad de la frecuencia cardiaca, medida como razón de Baja frecuencia/Alta frecuencia, con un punto de corte de 2.5 tomada con un reloj POLAR RS800CX, en una población de pacientes con embarazo a término llevadas a cesárea, en un hospital de tercer nivel en Bogotá- Colombia entre Febrero y Abril del 2015. RESULTADOS El estudio incluyó 82 pacientes. Se determinó que la razón Baja frecuencia/Alta frecuencia mayor a 2,5 era poco frecuente en nuestra población (15.85%), y su asociación no fue significativa. DISCUSION El presente estudio demostró que la asociación entre la presencia de hipotensión y un índice Baja frecuencia/Alta frecuencia con punto de corte de 2.5 no es significativo para nuestra población de mujeres con embarazo a término llevadas a cesárea con anestesia espinal. Según los resultados se sugieres un punto de corte de 1.6 como punto de partida para la realización de nuevos estudios que permitan validar este valor.