881 resultados para Regulation on the energy performance of residential buildings


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de Mestrado, Engenharia Civil, Especialização em Construção, Instituto Superior de Engenharia, Universidade do Algarve, 2016

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energy efficiency of buildings is attracting significant attention from the research community as the world is moving towards sustainable buildings design. Energy efficient approaches are measures or ways to improve the energy performance and energy efficiency of buildings. This study surveyed various energy-efficient approaches for commercial building and identifies Envelope Thermal Transfer Value (ETTV) and Green applications (Living wall, Green facade and Green roof) as most important and effective methods. An in-depth investigation was carried out on these energy-efficient approaches. It has been found that no ETTV model has been developed for sub-tropical climate of Australia. Moreover, existing ETTV equations developed for other countries do not take roof heat gain into consideration. Furthermore, the relationship of ETTV and different Green applications have not been investigated extensively in any literature, and the energy performance of commercial buildings in the presence of Living wall, Green facade and Green roof has not been investigated in the sub-tropical climate of Australia. The study has been conducted in two phases. First, the study develops the new formulation, coefficient and bench mark value of ETTV in the presence of external shading devices. In the new formulation, roof heat gain has been included in the integrated heat gain model made of ETTV. In the 2nd stage, the study presents the relationship of thermal and energy performance of (a) Living wall and ETTV (b) Green facade and ETTV (c) Combination of Living wall, Green facade and ETTV (d) Combination of Living wall, Green Roof and ETTV in new formulations. Finally, the study demonstrates the amount of energy that can be saved annually from different combinations of Green applications, i.e., Living wall, Green facade; combination of Living wall and Green facade; combination of Living wall and Green roof. The estimations are supported by experimental values obtained from extensive experiments of Living walls and Green roofs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

EXECUTIVE SUMMARY All observers agree that energy efficiency must be the cornerstone of any serious EU energy strategy. In this general context, the EU building sector is critical. It represents about 40% of EU final energy consumption (residential houses, public/private offices, commercial buildings, etc.) and approximately 36% of EU CO2 emissions. This is massive. The EU has certainly not been inactive in this field. The Energy Performance in Buildings Directive 2002/91/EC (EPBD) was the first and the main instrument to address the problem of the energy performance of buildings. It has established numerous principles: a reliable methodology which enables the calculation and rating of the energy performance of buildings; minimum energy performance standards for new buildings and existing buildings under major renovation; energy performance certificates; regular inspection of heating and air-conditioning systems; and, finally, quality standards for inspections and energy performance certificates. They were strengthened in 2010 by the recast Directive 2010/31/EU. This directive also introduces a decisive concept for the development of the building sector: ‘nearly zeroenergy buildings’. In 2012, the new Energy Efficiency Directive 2012/27/EU dealt with other aspects. In the building sector, three of them are particularly important. They concern: (1) the establishment of long-term strategies for mobilizing investment in the renovation of the national building stocks; (2) the introduction of energy saving schemes for ‘designated’ energy companies with a view to reducing consumption among ‘final consumers’ by 1.5% annually; and (3), as an option, the setting up of an Energy Efficiency National Fund to support energy efficiency initiatives. This paper also briefly examines the different instruments put in place to disseminate information and consultation, and the EU funding for energy efficiency in buildings. Results, however, have remained limited until now. The improvement of the energy performance of buildings and the rhythm of renovation remain extremely weak. Member States’ unwillingness to timely and properly transpose and implement the Directives continues despite the high degree of flexibility permitted. The decentralized approach chosen for some specific aspects and the differentiation in the application of EPBD standards between Member States do not appear optimal either. Adequate financial schemes remain rare. The permanent deficit of qualified and trained personnel and the inertia of public authorities to make the public understand the stakes in this domain remain problematic. Hence the need to take new initiatives to reap the benefits that the building sector is meant to bring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a review undertaken to understand the concept of 'future-proofing' the energy performance of buildings. The long lifecycles of the building stock, the impacts of climate change and the requirements for low carbon development underline the need for long-term thinking from the early design stages. 'Future-proofing' is an emerging research agenda with currently no widely accepted definition amongst scholars and building professionals. In this paper, it refers to design processes that accommodate explicitly full lifecycle perspectives and energy trends and drivers by at least 2050, when selecting energy efficient measures and low carbon technologies. A knowledge map is introduced, which explores the key axes (or attributes) for achieving a 'future-proofed' energy design; namely, coverage of sustainability issues, lifecycle thinking, and accommodating risks and uncertainties that affect the energy consumption. It is concluded that further research is needed so that established building energy assessment methods are refined to better incorporate future-proofing. The study follows an interdisciplinary approach and is targeted at design teams with aspirations to achieve resilient and flexible low-energy buildings over the long-term. © 2012 Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Heating, ventilation, air conditioning and refrigeration (HVAC&R) systems account for more than 60% of the energy consumption of buildings in the UK. However, the effect of the variety of HVAC&R systems on building energy performance has not yet been taken into account within the existing building energy benchmarks. In addition, the existing building energy benchmarks are not able to assist decision-makers with HVAC&R system selection. This study attempts to overcome these two deficiencies through the performance characterisation of 36 HVAC&R systems based on the simultaneous dynamic simulation of a building and a variety of HVAC&R systems using TRNSYS software. To characterise the performance of HVAC&R systems, four criteria are considered; energy consumption, CO2 emissions, thermal comfort and indoor air quality. The results of the simulations show that, all the studied systems are able to provide an acceptable level of indoor air quality and thermal comfort. However, the energy consumption and amount of CO2 emissions vary. One of the significant outcomes of this study reveals that combined heating, cooling and power systems (CCHP) have the highest energy consumption with the lowest energy related CO2 emissions among the studied HVAC&R systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the influence of interlayer properties on the blast performance of laminated glass (LG) panels. A parametric study is carried out by varying the thickness and Young’s modulus (E) of the interlayer under two different blast loads. Results indicate the existence of a critical interlayer thickness (or E) that causes the onset of interlayer failure. This should be achieved in the design to enhance energy absorption, reduce support reactions and initiate a safer failure mode. Present findings provide information to achieve such design targets and enable safe and efficient performance of LGs under credible blast loads.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the influence of structural sealant joints on the blast performance of laminated glass (LG) panels, using a comprehensive numerical procedure. A parametric study was carried out by varying the width, thickness and the Young’s modulus (E) of the structural silicone sealant joints and the behavior of the LG panel was studied under two different blast loads. Results show that these parameters influence the blast response of LG panels, especially under the higher blast load. Sealant joints that are thicker, have smaller widths and lower E values increase the flexibility at the supports and hence increase the energy absorption of the LG panel while reducing the support reactions. Results also confirmed that sealant joints designed according to current standards perform well under blast loads. Modeling techniques presented in this paper could be used to complement and supplement the guidance in existing design standards. The new information generated in this paper will contribute towards safer and more economical designs of entire facade systems including window glazing, frames and supporting structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of ionic liquid (IL) electrolytes promises to improve the energy density of electrochemical capacitors (ECs) by allowing for operation at higher voltages. Several studies have also shown that the pore size distribution of materials used to produce electrodes is an important factor in determining EC performance. In this research the capacitative, energy and power performance of ILs 1-ethyl-3- methylimidazolium tetrafluoroborate (EMImBF4), 1-ethyl-3-methylimidazolium dicyanamide (EMImN(CN)2), 1,2-dimethyl-3-propylimidazolium bis(trifluoromethylsulfonyl)imide (DMPImTFSI), and 1-butyl-3-methylpyrrolidinium tris(pentafluoroethyl)trifluorophosphate (BMPyT(F5Et)PF3) were studied and compared with the commercially utilised organic electrolyte 1M tetraethylammonium tetrafluoroborate solution in anhydrous propylene carbonate (Et4NBF4–PC 1 M). To assess the effect of pore size on IL performance, controlled porosity carbons were produced from phenolic resins activated in CO2. The carbon samples were characterised by nitrogen adsorption– desorption at 77 K and the relevant electrochemical behaviour was characterised by cyclic voltammetry, galvanostatic charge–discharge and electrochemical impedance spectroscopy. The best capacitance performance was obtained for the activated carbon xerogel with average pore diameter 3.5 nm, whereas the optimum rate performance was obtained for the activated carbon xerogel with average pore diameter 6 nm. When combined in an EC with IL electrolyte EMImBF4 a specific capacitance of 210 F g1 was obtained for activated carbon sample with average pore diameter 3.5 nm at an operating voltage of 3 V. The activated carbon sample with average pore diameter 6 nm allowed for maximum capacitance retention of approximately 70% at 64 mA cm2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Non-Volatile Memory (NVM) technology holds promise to replace SRAM and DRAM at various levels of the memory hierarchy. The interest in NVM is motivated by the difficulty faced in scaling DRAM beyond 22 nm and, long-term, lower cost per bit. While offering higher density and negligible static power (leakage and refresh), NVM suffers increased latency and energy per memory access. This paper develops energy and performance models of memory systems and applies them to understand the energy-efficiency of replacing or complementing DRAM with NVM. Our analysis focusses on the application of NVM in main memory. We demonstrate that NVM such as STT-RAM and RRAM is energy-efficient for memory sizes commonly employed in servers and high-end workstations, but PCM is not. Furthermore, the model is well suited to quickly evaluate the impact of changes to the model parameters, which may be achieved through optimization of the memory architecture, and to determine the key parameters that impact system-level energy and performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foi avaliado o desempenho energético da suinocultura integrada à produção de milho em grão em sistema de plantio direto mecanizado. Nesta concepção de integração proposta, os dejetos suínos são utilizados como fertilizantes na produção de milho. O sistema foi delimitado envolvendo as atividades associadas ao manejo dos suínos e de produção do milho (manejo do solo, cultivo e colheita). O período de análise considerado foi de um ano, o que possibilita a produção de três lotes de suínos e duas safras de milho. Para avaliar o desempenho energético, foram criados três indicadores: eficiência energética, eficiência de uso de fontes não renováveis e o custo de energia não renovável para a produção de proteína. As entradas energéticas são compostas pelos insumos e pela infraestrutura, utilizados na criação dos suínos e na produção de milho, e pela radiação solar incidente no agrossistema. Já as saídas são representadas pelos seus produtos (suínos terminados e o milho). Os resultados obtidos nas simulações apontam que a integração melhora o desempenho energético das granjas suinícolas, aumentando a eficiência energética (186%) e a eficiência não renovável (352%), além de reduzir o custo de energia não renovável para a produção de proteína (‑58%).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

1. To determine whether diltiazem protects the hypoxic myocardium by reducing contractile work, we have compared the effects of diltiazem and quiescence on left ventricular (LV) papillary muscle subjected to hypoxia. Papillary muscles were obtained from male Charles River CD rats weighing 150-250 g.2. Four groups of muscles were studied: control (N = 6), non-stimulation (N = 10), diltiazem 10(-4) M (N = 6) and diltiazem 10(-4) M plus non-stimulation (N = 10).3. Isolated mt LV papillary muscles were studied in Krebs-Henseleit solution with a calcium concentration of 2.52 mM at 28-degrees-C while contracting isometrically at a stimulation rate of 0.2 Hz. Resting tension and active isometric tension were measured.4. Both diltiazem and quiescence significantly attenuated contracture tension during hypoxia (0.91 +/- 0.10 vs 2.26 +/- 0.49 g/mm2 for diltiazem vs control, and 0.55 +/- 0.18 vs 2.26 +/- 0.49 g/mm2 for quiescence vs control). Recovery of active tension was improved in the diltiazem groups during reoxygenation (4.16 +/- 0.42 vs 3.75 +/- 0.51, 3.53 +/- 0.15 vs 2.90 +/- 0.13, 5.84 +/- 0.33 vs 6.48 +/- 0.29 and 5.98 +/- 0.90 vs 7.67 +/- 0.68 g/mm2 for diltiazem, diltiazem non-stimulation, non-stimulation and control groups).5. The results suggest that the protective effect of diltiazem during hypoxia was due to the reduction in energy demand of the myocardium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Effects of severe hypercapnia have been extensively studied in marine fishes, while knowledge on the impacts of moderately elevated CO2 levels and their combination with warming is scarce. Here we investigate ion regulation mechanisms and energy budget in gills from Atlantic cod acclimated long-term to elevated PCO2 levels (2500 µatm) and temperature (18 °C). Isolated perfused gill preparations established to determine gill thermal plasticity during acute exposures (10-22 °C) and in vivo costs of Na+/K+-ATPase activity, protein and RNA synthesis. Maximum enzyme capacities of F1Fo-ATPase, H+-ATPase and Na+/K+-ATPase were measured in vitro in crude gill homogenates. After whole animal acclimation to elevated PCO2 and/or warming, branchial oxygen consumption responded more strongly to acute temperature change. The fractions of gill respiration allocated to protein and RNA synthesis remained unchanged. In gills of fish CO2-exposed at both temperatures, energy turnover associated with Na+/K+-ATPase activity was reduced by 30% below rates of control fish. This contrasted in vitro capacities of Na+/K+-ATPase, which remained unchanged under elevated CO2 at 10 °C, and earlier studies which had found a strong upregulation under severe hypercapnia. F1Fo-ATPase capacities increased in hypercapnic gills at both temperatures, whereas Na+/K+ATPase and H+-ATPase capacities only increased in response to elevated CO2 and warming indicating the absence of thermal compensation under CO2. We conclude that in vivo ion regulatory energy demand is lowered under moderately elevated CO2 levels despite the stronger thermal response of total gill respiration and the upregulation of F1Fo-ATPase. This effect is maintained at elevated temperature.