990 resultados para RECESSION-TYPE DEFECTS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The semiconductor particle detectors used at CERN experiments are exposed to radiation. Under radiation, the formation of lattice defects is unavoidable. The defects affect the depletion voltage and leakage current of the detectors, and hence affect on the signal-to-noise ratio of the detectors. This shortens the operational lifetime of the detectors. For this reason, the understanding of the formation and the effects of radiation induced defects is crucial for the development of radiation hard detectors. In this work, I have studied the effects of radiation induced defects-mostly vacancy related defects-with a simulation package, Silvaco. Thus, this work essentially concerns the effects of radiation induced defects, and native defects, on leakage currents in particle detectors. Impurity donor atom-vacancy complexes have been proved to cause insignificant increase of leakage current compared with the trivacancy and divacancy-oxygen centres. Native defects and divacancies have proven to cause some of the leakage current, which is relatively small compared with trivacancy and divacancy-oxygen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: The aim of this randomized controlled clinical study was to compare the use of an acellular dermal matrix graft (ADMG) with or without the enamel matrix derivative (EMD) in smokers to evaluate which procedure would provide better root coverage. Material and Methods: Nineteen smokers with bilateral Miller Class I or II gingival recessions >= 3 mm were selected. The test group was treated with an association of ADMG and EMD, and the control group with ADMG alone. Probing depth, relative clinical attachment level, gingival recession height, gingival recession width, keratinized tissue width and keratinized tissue thickness were evaluated before the surgeries and after 6 months. Wilcoxon test was used for the statistical analysis at significance level of 5%. Results: No significant differences were found between groups in all parameters at baseline. The mean gain recession height between baseline and 6 months and the complete root coverage favored the test group (p = 0.042, p = 0.019 respectively). Conclusion: Smoking may negatively affect the results achieved through periodontal plastic procedures; however, the association of ADMG and EMD is beneficial in the root coverage of gingival recessions in smokers, 6 months after the surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim This randomized, controlled, clinical study compared two surgical techniques for root coverage with the acellular dermal matrix graft (ADMG) to evaluate which procedure could provide better root coverage and greater amounts of keratinized tissue. Materials and Methods Fifteen pairs of bilateral Miller Class I or II gingival recessions were treated and assigned randomly to the test group, and the contra-lateral recessions were assigned to the control group. The ADMG was used in both groups. In the control group, the graft and flap were positioned at the level of the cemento-enamel junction (CEJ), and in the test group, the graft was positioned 1 mm apical to the CEJ and the flap 1 mm coronal to the CEJ. The clinical parameters were taken before the surgeries and after 6 months. The gingival recession area, a new parameter, was measured in standardized photographs through a special device and software. Results There were statistically significant differences favouring the proposed technique for all parameters except for the amount of keratinized tissue at 6 months. Conclusions The proposed test technique is more suitable for root coverage procedures with ADMG, and the new parameter evaluated appears valuable for root coverage analysis. (Clinicaltrials.gov Identifier: NCT01175720).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many techniques have been proposed for root coverage. However, none of them presents predictable results in deep and wide recessions. Objective: The aim of this case series report is to describe an alternative technique for root coverage at sites showing deep recessions and attachment loss >4 mm at buccal sites. Material and Methods: Four patients presenting deep recession defects at buccal sites (>= 4 mm) were treated by the newly forming bone graft technique, which consists in the creation of an alveolar socket at edentulous ridge and transferring of granulation tissue present in this socket to the recession defect after 21 days. Clinical periodontal parameters, including recession depth (RD), probing depth (PD), clinical attachment level (CAL), bleeding on probing (BOP), plaque index (PI) and keratinized gingiva width (KGW) were evaluated by a single examiner immediately before surgery and at 1, 3, 6 and 9 months postoperatively. Results: All cases showed reduction in RD and PD, along with CAL gain, although no increase in KGW could be observed. These findings suggest that the technique could favor periodontal regeneration along with root coverage, especially in areas showing deep recessions and attachment loss.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: The purpose of this study was to investigate the periodontal healing pattern of dehiscence-type defects following different chemical root conditioning modalities. Materials and methods: Buccal osseous dehiscence defects were created on six teeth of seven dogs. After dental plaque accumulation, defects were treated with sterile saline solution (control group) or one chemical conditioning modality: citric acid (CA group), ethylenediaminetetraacetic acid (EDTA group), tetracycline (TTC group), citric acid + tetracycline (CA + TTC group), or tetracycline + citric acid (TTC + CA group). After 3 months of healing, clinical parameters were evaluated, and the animals were killed. Histological sections were processed, and a computer-assisted histometric analysis was used to evaluate the formation of new cementum, new bone, and epithelial apical migration. Results: All treatments yielded significant improvements in terms of probing depth decrease and clinical attachment level gain compared to baseline values; however, without significant differences among the groups (p > 0.05; one-way ANOVA). The highest amount of new cementum was noted in the EDTA group (3.72 ± 0.83 mm, 77.6 %), while the lowest amount of new bone was observed in the TTC group (0.7 ± 0.94 mm, 14.3 %). However, no statistically significant differences could be observed among the groups regarding epithelial apical migration, new cementum, and alveolar bone formation (p > 0.05). Conclusion: Chemical root surface conditioning did not promote any significant improvement in periodontal healing pattern of dehiscence-type defects in dogs. Clinical Relevance: Chemical root surface conditioning after surgical debridement did not promote positive or negative effects on periodontal healing pattern of dehiscence-type defects. © 2012 Springer-Verlag Berlin Heidelberg.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

AIMS The objective of this study is to evaluate the effects of a paste-like bone substitute material with easy handling properties and improved mechanical stability on periodontal regeneration of intrabony defects in dogs. MATERIALS AND METHODS Mandibular and maxillary first and third premolars were extracted, and three-wall intrabony defects were created on second and fourth premolars. After a healing period of 3 months, acute type defects were filled with a paste-like formulation of deproteinized bovine bone mineral (DBBM) (particle size, 0.125-0.25 mm) in a collagenous carrier matrix (T1), pulverized DBBM (particle size, 0.125-0.25 mm) without the carrier (T2), or Bio-Oss® granules (particle size, 0.25-1.00 mm) as control (C). All defects were covered with a Bio-Gide® membrane. The dogs were sacrificed after 12 weeks, and the specimens were analyzed histologically and histometrically. RESULTS Postoperative healing of all defects was uneventful, and no histological signs of inflammation were observed in the augmented and gingival regions. New cementum, new periodontal ligament, and new bone were observed in all three groups. The mean vertical bone gain was 3.26 mm (T1), 3.60 mm (T2), and 3.81 mm (C). That of new cementum was 2.25 mm (T1), 3.88 mm (T2), and 3.53 mm (C). The differences did not reach statistical significance. The DBBM particles were both incorporated in new bone and embedded in immature bone marrow. CONCLUSIONS The results of this preclinical study showed that the 0.125-0.25-mm DBBM particles in a powder or paste formulation resulted in periodontal regeneration comparable to the commercially available DBBM. Osteoconductivity, in particular, was not affected by DBBM size or paste formulation. CLINICAL RELEVANCE The improved handling properties of the paste-like bone substitute consisting of small DBBM particles embedded in a collagen-based carrier hold promise for clinical applications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Understanding the magnetic properties of graphenic nanostructures is instrumental in future spintronics applications. These magnetic properties are known to depend crucially on the presence of defects. Here we review our recent theoretical studies using density functional calculations on two types of defects in carbon nanostructures: Substitutional doping with transition metals, and sp$^3$-type defects created by covalent functionalization with organic and inorganic molecules. We focus on such defects because they can be used to create and control magnetism in graphene-based materials. Our main results are summarized as follows: i)Substitutional metal impurities are fully understood using a model based on the hybridization between the $d$ states of the metal atom and the defect levels associated with an unreconstructed D$_{3h}$ carbon vacancy. We identify three different regimes, associated with the occupation of distinct hybridization levels, which determine the magnetic properties obtained with this type of doping; ii) A spin moment of 1.0 $\mu_B$ is always induced by chemical functionalization when a molecule chemisorbs on a graphene layer via a single C-C (or other weakly polar) covalent bond. The magnetic coupling between adsorbates shows a key dependence on the sublattice adsorption site. This effect is similar to that of H adsorption, however, with universal character; iii) The spin moment of substitutional metal impurities can be controlled using strain. In particular, we show that although Ni substitutionals are non-magnetic in flat and unstrained graphene, the magnetism of these defects can be activated by applying either uniaxial strain or curvature to the graphene layer. All these results provide key information about formation and control of defect-induced magnetism in graphene and related materials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An experimental method of studying shifts between concentration-versus-depth profiles of vacancy- and interstitial-type defects in ion-implanted silicon is demonstrated. The concept is based on deep level transient spectroscopy measurements utilizing the filling pulse variation technique. The vacancy profile, represented by the vacancy¿oxygen center, and the interstitial profile, represented by the interstitial carbon¿substitutional carbon pair, are obtained at the same sample temperature by varying the duration of the filling pulse. The effect of the capture in the Debye tail has been extensively studied and taken into account. Thus, the two profiles can be recorded with a high relative depth resolution. Using low doses, point defects have been introduced in lightly doped float zone n-type silicon by implantation with 6.8 MeV boron ions and 680 keV and 1.3 MeV protons at room temperature. The effect of the angle of ion incidence has also been investigated. For all implantation conditions the peak of the interstitial profile is displaced towards larger depths compared to that of the vacancy profile. The amplitude of this displacement increases as the width of the initial point defect distribution increases. This behavior is explained by a simple model where the preferential forward momentum of recoiling silicon atoms and the highly efficient direct recombination of primary point defects are taken into account.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)