904 resultados para Propulsive force
Resumo:
This study aimed to determine whether: i) tethered-swimming can be used to identify the asymmetry during front crawl swimming style; ii) swimmers that perform unilateral breathing present greater asymmetry in comparison to others that use bilateral breathing; iii) swimmers of best performance present smaller asymmetry than their counterparts; iv) repeated front crawl swimming movements influence body asymmetry. 18 swimmers were assessed for propulsive force parameters (peak force, mean force, impulse and rate of force development) during a maximal front crawl tethered-swimming test lasting 2 min. A factorial analysis showed that propulsive forces decreased at the beginning, intermediate and end of the test (p<0.05), but the asymmetries were not changed at different instants of the test. When breathing preference (uni- or bilateral) was analyzed, asymmetry remained unchanged in all force parameters (p>0.05). When performance was considered (below or above mean group time), a larger asymmetry was found in the sub-group of lower performance in comparison to those of best performance (p<0.05). Therefore, the asymmetries of the propulsive forces can be detected using tethered-swimming. The propulsive forces decreased during the test but asymmetries did not change under testing conditions. Although breathing preference did not influence asymmetry, swimmers with best performance were less asymmetric than their counterparts. © Georg Thieme Verlag KG Stuttgart New York.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Background: It is known that when barefoot, gait biomechanics of diabetic neuropathic patients differ from nondiabetic individuals. However, it is still unknown whether these biomechanical changes are also present during shod gait which is clinically advised for these patients. This study investigated the effect of the participants own shoes on gait biomechanics in diabetic neuropathic individuals compared to barefoot gait patterns and healthy controls. Methods: Ground reaction forces and lower limb EMG activities were analyzed in 21 non-diabetic adults (50.9 +/- 7.3 yr, 24.3 +/- 2.6 kg/m(2)) and 24 diabetic neuropathic participants (55.2 +/- 7.9 yr, 27.0 +/- 4.4 kg/m(2)). EMG patterns of vastus lateralis, lateral gastrocnemius and tibialis anterior, along with the vertical and antero-posterior ground reaction forces were studied during shod and barefoot gait. Results: Regardless of the disease, walking with shoes promoted an increase in the first peak vertical force and the peak horizontal propulsive force. Diabetic individuals had a delay in the lateral gastrocnemius EMG activity with no delay in the vastus lateralis. They also demonstrated a higher peak horizontal braking force walking with shoes compared to barefoot. Diabetic participants also had a smaller second peak vertical force in shod gait and a delay in the vastus lateralis EMG activity in barefoot gait compared to controls. Conclusions: The change in plantar sensory information that occurs when wearing shoes revealed a different motor strategy in diabetic individuals. Walking with shoes did not attenuate vertical forces in either group. Though changes in motor strategy were apparent, the biomechanical did not support the argument that the use of shoes contributes to altered motor responses during gait.
Resumo:
An application of the linear machine one-dimensional analysis method to the modeling of a conventional asynchronous induction motor, considered as a particular case of linear and sectorial machines, is described. A mathematical model for the calculation of the propulsive force developed by this motor, taking into account the transversal edge effect, is derived from the application of the one-dimensional theory and presented in this paper. As an application example, an induction motor is analyzed by means of the one-dimensional theory.
Resumo:
This work deals with the analytical, computational and experimental study of phenomena related to the Eddy current induction in low permeability means for embedded electromagnetic braking systems applications. The phenomena of forces generation in opposing to the variation of stationary magnetic flux produced by DC power supplies, set in motion by the application of an external propulsive force are addressed. The study is motivated by search for solving the problem of speed control of PIGs used to verifying and maintaining pipelines, and is led based on the analytical models synthesis, validated by means of computer simulations in Finite Elements environment, provided by engineering support software; and with experimental tests conducted under controlled laboratory conditions. Finally, a damping systems design methodology based on analyzes results conducted throughout the study is presented
Resumo:
The aim of the present study was to examine the reliability of tethered swimming in the evaluation of age group swimmers. The sample was composed of 8 male national level swimmers with at least 4 years of experience in competitive swimming. Each swimmer performed two 30 second maximal intensity tethered swimming tests, on separate days. Individual force-time curves were registered to assess maximum force, mean force and the mean impulse of force. Both consistency and reliability were very strong, with Cronbach’s Alpha values ranging from 0.970 to 0.995. All the applied metrics presented a very high agreement between tests, with the mean impulse of force presenting the highest. These results indicate that tethered swimming can be used to evaluate age group swimmers. Furthermore, better comprehension of the swimmers ability to effectively exert force in the water can be obtained using the impulse of force. Key words: swimming, training and testing, propulsive force, front crawl.
Resumo:
O documento em anexo encontra-se na versão pre-print (versão inicial enviada para o editor).
Resumo:
OBJECTIVES: To evaluate and compare long-term functional outcome after partial carpal arthrodesis and pancarpal arthrodesis in dogs using kinetic gait analysis. METHODS: Fourteen dogs with 19 partial carpal or pancarpal arthrodeses were retrospectively examined and underwent force-plate gait analysis. Mean times since surgery were 29.4 and 24.4 months for pancarpal and partial carpal arthrodesis respectively. Vertical and braking-propulsive ground reaction force profiles were compared between treatment groups, and to those of normal dogs (control group) using Kruskal-Wallis one-way analysis of variance. RESULTS: With the exception of time to vertical peak that occurred earlier in dogs with pancarpal than in dogs with partial carpal arthrodesis (p <0.01), there was no difference between the two treatment groups. Several parameters differed significantly between operated and healthy dogs (p <0.01): vertical impulses were significantly lower in both treatment groups, braking forces and impulses were also reduced after both techniques. Propulsive forces and impulses were only reduced in dogs with pancarpal arthrodesis. When comparing gait parameters of sound limbs of unilateral operated dogs to those of control dogs, braking forces and impulses (p <0.01; p <0.05) were significantly higher in the sound legs of unilateral operated dogs. CLINICAL SIGNIFICANCE: Long-term outcome after partial carpal and pancarpal arthrodesis is good and comparable to each other. Propulsive action may be altered more in dogs with pancarpal arthrodesis.
Resumo:
The aim was to evaluate the relationship between orofacial function, dentofacial morphology, and bite force in young subjects. Three hundred and sixteen subjects were divided according to dentition stage (early, intermediate, and late mixed and permanent dentition). Orofacial function was screened using the Nordic Orofacial Test-Screening (NOT-S). Orthodontic treatment need, bite force, lateral and frontal craniofacial dimensions and presence of sleep bruxism were also assessed. The results were submitted to descriptive statistics, normality and correlation tests, analysis of variance, and multiple linear regression to test the relationship between NOT-S scores and the studied independent variables. The variance of NOT-S scores between groups was not significant. The evaluation of the variables that significantly contributed to NOT-S scores variation showed that age and presence of bruxism related to higher NOT-S total scores, while the increase in overbite measurement and presence of closed lip posture related to lower scores. Bite force did not show a significant relationship with scores of orofacial dysfunction. No significant correlations between craniofacial dimensions and NOT-S scores were observed. Age and sleep bruxism were related to higher NOT-S scores, while the increase in overbite measurement and closed lip posture contributed to lower scores of orofacial dysfunction.
Resumo:
Friction and triboelectrification of materials show a strong correlation during sliding contacts. Friction force fluctuations are always accompanied by two tribocharging events at metal-insulator [e.g., polytetrafluoroethylene (PTFE)] interfaces: injection of charged species from the metal into PTFE followed by the flow of charges from PTFE to the metal surface. Adhesion maps that were obtained by atomic force microscopy (AFM) show that the region of contact increases the pull-off force from 10 to 150 nN, reflecting on a resilient electrostatic adhesion between PTFE and the metallic surface. The reported results suggest that friction and triboelectrification have a common origin that must be associated with the occurrence of strong electrostatic interactions at the interface.
Resumo:
The objective of this study was to evaluate the retention force of T-bar clasps made from commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) alloy by the insertion/removal test simulating 5 years use. Thirty-six frameworks were cast from CP Ti (n=18) and Co-Cr alloy (n=18) with identical prefabricated patterns on refractory casts from a distal extension mandibular hemi-arch segment. The castings were made on a vacuum-pressure machine, under vacuum and argon atmosphere. Each group was subdivided in three, corresponding to 0.25 mm, 0.50 mm and 0.75 mm undercuts, respectively. No polishing procedures were performed to ensure uniformity. The specimens were subjected to an insertion/removal test and data was analyzed statistically to compare CP Ti and Co-Cr alloy in the same undercut (Student's t-test for independent samples) and each material in different undercuts (one-way ANOVA) (p=0.05). Comparisons between materials revealed significant differences (p=0.017) only for the 0.50-mm undercut. No significant differences (p>0.05) were found when comparing the same material for the undercuts. It may be concluded that for different undercuts, both Co-Cr alloy and CP Ti had no significant differences for T-bar clasps; CP Ti showed the lowest retention force values when compared to Co-Cr alloy in each undercut, but with significant difference only for the 0.50-mm undercut; and both materials maintained the retentive capacity during the simulation test.