973 resultados para Physicochemical parameters
Resumo:
This study examines zooplankton periodicity and some physicochemical parameters of the intake channel of Lake Chad (Nigeria). Nine different zooplankton species were identified at the sampling station 1, while seven different zooplankton species were identified at the sampling station 2 (the intake channel of Lake Chad). Each identified zooplankton species was grouped according to its major group of copepods, Cladocera or Rotifera. The copepods dominated the zooplankton community with the highest numbers of occurrence as Cyclopedia species throughout the course of the study at both station l and 2. There was a clear evidence of the influence of organic manure nutrients on total zooplankton population at station 1 when compared to that of station 2. The water quality variables measured in the course of this study show that the surface water temperature in station 1 ranges from 27.5 degree C to 30.5 degree C. The pH ranges from 6.8 to 8.5, while D.O. contents ranges from 2.9mg/L to 6.1mg/L and alkalinity recorded was 172.00 to 208.00. At the station 2 the water quality parameters obtained show that surface water temperature ranges from 27.3 degree C to 30.2 degree C, pH ranges between 6.9 to 8.5, while the D.O contents ranges from 3.0 mg/L to 6.2 mg/L.Alkalinity ranges from 172mg/L to 212 mg/L
Resumo:
The effect of physico-chemical parameters and plankton composition on fish production in ponds was investigated in six fish farms for eight weeks. The physicochemical parameters investigated were temperature=25-30 plus or minus C, transparency=0.45-0.57m, dissolved oxygen=3.0-10.9mg/l, pH=6.0-7.7, dissolved carbon dioxide=5.46-28.3mg/l, total alkalinity=44.37-80.0ppm, chemical oxygen demand=31.88-72.18mg/l and biological oxygen demand=0.66-48.34mg/l. Plankton composition varies and was made of four families of phytoplankton namely; Cyanophyceae, Chlorophyceae, Dinophyceae and Diatomida; and four families of zooplankton viz; Protozoa, Rotifera, Copepoda and Dinoflagellates. Farm 1 and 6 recorded the highest average weight of about 1.0kg and average total length of about 40.0cm for the two fish species. This study showed that fish yield was dependable on the quality and management of pond water characteristics
Resumo:
The effect of physico-chemical parameters and plankton composition on fish production in ponds was investigated in six fish farms for eight weeks. The physicochemical parameters investigated were temperature=25-30 plus or minus C, transparency=0.45-0.57m, dissolved oxygen=3.0-10.9mg/l, pH=6.0-7.7, dissolved carbon dioxide=5.46-28.3mg/l, total alkalinity=44.37-80.0ppm, chemical oxygen demand=31.88-72.18mg/l and biological oxygen demand=0.66-48.34mg/l. Plankton composition varies and was made of four families of phytoplankton namely: Cyanophyceae, Chlorophyceae, Dinophyceae and Diatomida; and four families of zooplankton viz: Protozoa, Rotifera, Copepoda and Dinoflagellates. Farm 1 and 6 recorded the highest average weight of about 1.0kg and average total length of about 40.0cm for the two fish species. This study showed that fish yield was dependable on the quality and management of pond water characteristics
Resumo:
Kalyani lake (P sub(1)), a weed infested recreational water body and a weed chocked derelict water body (P sub(2)) in the heart of Kalyani city of West Bengal were studied for a period of one year for their primary productivity and other physicochemical parameters. Very low primary productivity (GPP=360-1237mg C m super(-2) d super(-1); NPP=157-787 mg C m super(-2) d super(-1)) was recorded in P sub(2) in spite of having a high concentration of nutrients (PO sub(4)–P=0.052-0.260mg l super(- 1); NO sub(3)-N=0.110-0.412mg l super(-1)). On the other hand, moderate primary productivity (GPP=1687-3195mg C m super(-2) d super(-1); NPP=900-2700mg C m super(-2) d super(-1)) was found in P sub(1) with comparatively low range of nutrients (P0 sub(4)-P =0.010-0.058mg l super(-1); NO sub(3)-N=0.032-0.118mg l super(-1)). After studying the other physicochemical parameters (temperature, transparency, dissolved oxygen, free carbon dioxide, pH, alkalinity and macrophytic biomass), it was found that the overall hydro-biological conditions of the weed-chocked derelict water body (P sub(2)) is not congenial for biological production as compared to Kalyani Lake (P sub(1)). Kalyani Lake may be used for fish culture with proper management practices.
Resumo:
The effect of organic and conventional agricultural systems on the physicochemical parameters, bioactive compounds content, and sensorial attributes of tomatoes (‘‘Redondo’’ cultivar) was studied. The influence on phytochemicals distribution among peel, pulp and seeds was also accessed. Organic tomatoes were richer in lycopene (+20%), vitamin C (+30%), total phenolics (+24%) and flavonoids (+21%) and had higher (+6%) in vitro antioxidant activity. In the conventional fruits, lycopene was mainly concentrated in the pulp, whereas in the organic ones, the peel and seeds contained high levels of bioactive compounds. Only the phenolic compounds had a similar distribution among the different fractions of both types of tomatoes. Furthermore, a sensorial analysis indicated that organic farming improved the gustative properties of this tomato cultivar.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Several Brazilian commercial gasoline physicochemical parameters, such as relative density, distillation curve (temperatures related to 10%, 50% and 90% of distilled volume, final boiling point and residue), octane numbers (motor and research octane number and anti-knock index), hydrocarbon compositions (olefins, aromatics and saturates) and anhydrous ethanol and benzene content was predicted from chromatographic profiles obtained by flame ionization detection (GC-FID) and using partial least square regression (PLS). GC-FID is a technique intensively used for fuel quality control due to its convenience, speed, accuracy and simplicity and its profiles are much easier to interpret and understand than results produced by other techniques. Another advantage is that it permits association with multivariate methods of analysis, such as PLS. The chromatogram profiles were recorded and used to deploy PLS models for each property. The standard error of prediction (SEP) has been the main parameter considered to select the "best model". Most of GC-FID-PLS results, when compared to those obtained by the Brazilian Government Petroleum, Natural Gas and Biofuels Agency - ANP Regulation 309 specification methods, were very good. In general, all PLS models developed in these work provide unbiased predictions with lows standard error of prediction and percentage average relative error (below 11.5 and 5.0, respectively). (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A set of sixteen para-substituted N,N-[(dimethylamino)ethyl] benzoate hydrochlorides structurally related to procaine was synthesized. The apparent partition coefficients were determined by either shake-flask or HPLC methods and were taken as hydrophobic parameters. The IR stretching frequencies of the carbonyl group were determined in chloroform and taken as one of the electronic parameters. Additional physicochemical parameters were either taken from the literature: pi, sigma, T and R, MR4, or calculated: log P. The lethal potency was determined in the mouse via the LD50. In order to verify the nature and the relative contributions of the physicochemical parameters to lethal toxicity, QSAR equations were derived using regression analysis. A major contribution of hydrophobicity to ether with a smaller but still significant contribution of electronic or polar properties was found to a describe the toxicity within this set of compounds.