Resumo:

The mechanism of beam splitting and principle of wide-field-of-view compensation of modified Savart polariscope in the wide-field-of-view polarization interference imaging spectrometer (WPIIS) are analyzed and discussed. Formulas for the lateral displacement and optical path difference (OPD) produced by the modified Savart polariscope are derived by ray-tracing method. The theoretical and practical guidance is thereby provided for the study, design, modulation, experiment and engineering of the polarization interference imaging spectrometers and other birefringent Fourier-transform spectrometers based on Savart polariscopes. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a technique applicable to interferometric systems illuminated by a laser diode, whereby the optical path difference is recovered by means of sinusoidal modulation of the laser emission frequency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new type of interferometer, the moving-optical-wedge interferometer, is presented, and its principle and properties are studied. The novel interferometer consists of one beam splitter, two flat fixed mirrors, two fixed compensating plates, one fixed optical wedge, and one moving optical wedge. The optical path difference (OPD) as a function of the displacement of the moving optical wedge from the zero path difference position is accomplished by the straight reciprocating motion of the moving optical wedge. A large physical shift of the moving optical wedge corresponds to a very short OPD value of the new interferometer if the values of the wedge angle and the refractive index of the two optical wedges are given properly. The new interferometer is not so sensitive to the velocity variation of the moving optical wedge and the mechanical disturbances compared with the Michelson interferometer, and it is very applicable to low-spectral-resolution application for any wavenumber region from the far infrared down to the ultraviolet. (C) 2008 Optical Society of America.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The adsorption of cationic surfactant cetylpyridinium bromide (CPB) on a glassy carbon (GC) electrode surface has been studied by spectroelectrochemistry with a long optical path length thin-layer cell (LOPTLC) for the first time. A fine adsorption isotherm of CPB molecules from an aqueous solution containing 0.10 M KBr has been obtained over the range of (1.00-8.00) x 10(-5) M. From theoretical calculation and experimental data, adsorption of CPB on the GC electrode surface shows four distinct orientations and three large orientation transitions. Compared with the ordinary isotherm, the differential isotherm is more characteristic and would be suitable for the study of orientation transitions of organic compounds. With a theoretical treatment of the adsorption isotherm, four orientations of adsorbed CPB on a GC electrode surface coincide with the Frumkin-Langmuir type. From adsorption parameters the Frumkin-Langmuir equations, the adsorption free energy and, therefore, the equilibrium constants of orientation transitions of the CPB molecule can be obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the electric dichroism of cetylpyridinium bromide (CPB) has been found and studied by spectroelectrochemistry with a long optical path length thin-layer cell (LOPTLC) for the first time. The CPB molecule with a long carbon chain and a polar pyridinium ring is anisotropic in molecular configuration or in polarizability. In the electric field of a thin-layer cell, the CPB molecule reorientates along the direction of the electric field and exhibits electric dichroism, which results in the increase of absorbance of CPB in the UV-vis range. By use of in situ measurement of spectroelectrochemistry, the order parameters of long molecular axis (S = 0.845) and short molecular axis (D = 0.155) and the angle between the long axis direction of the CPB molecule and the direction normal to the electrode surface (theta = 18-degrees 44') have been determined. These data were used to describe the state of arrangement of the molecules in the solution. The reorientation of CPB molecules is the result of the interaction between the anisotropic molecules and electric field. The effects of the concentration of CPB and of the applied electric field on the electric dichroism have been investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Absorbance detection in capillary electrophoresis (CE), offers an excellent mass sensitivity, but poor concentration detection limits owing to very small injection volumes (normally I to 10 nL). This aspect can be a limiting factor in the applicability of CE/UV to detect species at trace levels, particularly pesticide residues. In the present work, the optical path length of an on-column detection cell was increased through a proper connection of the column (75 mu m i.d.) to a capillary detection cell of 180 mu m optical path length in order to improve detectability. It is shown that the cell with an extended optical path length results in a significant gain in terms of signal to noise ratio. The effect of the increase in the optical path length has been evaluated for six pesticides, namely, carbendazim, thiabendazole, imazalil, procymidone triadimefon, and prochloraz. The resulting optical enhancement of the detection cell provided detection limits of ca. 0.3 mu g/mL for the studied compounds, thus enabling the residue analysis by CE/UV.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An interferometric technique was used to determine the temperature coefficient of the optical path length (dS/dT) as a function of the temperature in several optical glasses. The temperature range was between 25degreesC and 180degreesC. The studied samples included undoped and doped oxide glasses, such as low silica calcium aluminosilicate, phosphates, borates and also chalcogenides. The oxide glasses had dS/dT between 10 X 10(-6) K-1 and 20x10(-6) K-1, while for the chalcogenides, these were around 70 x 10(-6)K(-1). The results showed that dS/dTs increased with the temperature in all samples. For samples doped with Nd the dS/dT values were found to be independent of concentration. on the other hand, for the phosphate glass doped with Cr, dS/dT increased about 5% when compared with the Nd doped one. In conclusion, the used interferometric method, which is a considerably simpler and a lower cost technique, and is a useful tool to measure dS/dT in semi-transparent glasses as a function of the composition and temperature. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of high birefringence fiber interrogating interferometer for optical sensing applications was discussed. The method is of low cost and permits simple adjustment of the optical path difference and has much lower sensitivity to environmental perturbation. The polarization-maintaining (PM) fiber interferometer adopted a heterodyne approach using interferometric wavelength shift detection. The study showed that the inclusion of power amplifier driving a multi-element piezoelectric stack will enable the bandwidth to be pushed up into the kHz regime.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To this paper we discuss that the phase readout in low noise laser interferometers can significantly deviate from the underlying optical pathlength difference (OPD). The cross coupling of beam tilt to the interferometric phase readout is compared to the OPD. For such a system it is shown that the amount of tilt to phase readout coupling depends strongly on the involved beams and their parameters, as well as on the detector properties and the precise definition of the phase. The unique single element photodiode phase is therefore compared to three common phase definitions for quadrant diodes. It is shown that neither phase definition globally shows the least amount of cross coupling of angular it

Relevância:

100.00% 100.00%

Publicador:

Resumo:

提出了一种新思路来确定单分子的三维取向,在全内反射荧光显微成像的基础上,在显微镜的油镜上加一个水层,水和油的折射率不同造成光程差,产生离焦,利用全内反射产生隐失波激发了单分子的纵向分量,并在探测器前增加了一个分光镜,把光路分成偏振方向相互垂直的两束光,使得探测器上的光场分布包含单分子三维取向的信息。推导了隐失场激发的偶极矩光场在探测器上的光强分布表达式,通过分析偏振方向相互垂直的两束光在探测器上的不同的强度分布,来判断单分子偶极矩的三维取向。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A parallel plate interferometer with a reflecting mirror for measuring angular displacement is proposed. A deflection angle of a beam caused by an angular displacement is amplified by use of a reflecting mirror to increase the optical path difference (OPD) in the plane-parallel plate, which provides high sensitivity of the phase measurement. Detection of light transmitted through the plane-parallel plate with a position sensitive detector (PSD) enables high accurate measurement of the initial angle of incidence to the plane-parallel plate with insensitivity to stray light. The improved parallel plate interferometer achieves a measurement repeatability of 10(-8) rad. (C) 2007 The Optical Society of Japan.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

提出一种可提高平行平板角位移干涉测量仪测量精度的优化设计方法。对角位移干涉测量系统进行了误差分析,讨论了影响角位移测量精度的主要因素。分析了在干涉仪光路中入射到平行平板上的初始入射角度、平行平板的折射率以及厚度等参数的选取对角位移测量精度的影响。结果表明,优化选取最佳的初始入射角度以及元件参数,并在干涉光路中附加引入一平面反射镜形成光程差放大系统,可实现的角位移测量精度达10-8 rad数量级。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

在一种已有的角位移干涉测量技术的基础上,提出一种改进的角位移测量方法。通过选择合适的初始入射角,使从平板前后表面反射的两光束实现剪切干涉。采用一维位置探测器测量光束经透镜会聚后在探测器光敏面上的光点偏移量。根据干涉信号的相位和光点偏移量可以计算出被测物体的角位移。在该测量方案中,引入的一平面反射镜与被测物体的反射面形成光程差放大系统,提高了角位移测量灵敏度。分析了初始入射角对剪切比的影响,并讨论了基于该方案的角位移测量精度。实验结果表明,基于该技术的角位移重复测量精度达到10-8 rad数量级。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

提出一种基于正切关系和相位调制技术的动态小角度测量方法。使用双棱镜组成干涉测量臂引导两束平行光至分束棱镜处干涉,通过提取携带被测信息的干涉信号的相位实现动态的小角度测量。由于采用位置探测器(PSD)对测量臂中两平行光束的间距进行测量,简化了测量方程,消除了装置中双棱镜必须对称放置的要求。通过正弦地改变半导体激光器的注入电流在时域内实现对干涉信号的相位调制,形成准外差干涉测量模式,提高了光程差的测量精度。实验验证了该方法的可行性,并讨论了影响小角度测量精度的误差因素。研究结果表明,基于该方法的动态小角度的重