Parallel plate interferometer with a reflecting mirror for measuring angular displacement


Autoria(s): 郑德锋; 王向朝; Sasaki Osami
Data(s)

2007

Resumo

A parallel plate interferometer with a reflecting mirror for measuring angular displacement is proposed. A deflection angle of a beam caused by an angular displacement is amplified by use of a reflecting mirror to increase the optical path difference (OPD) in the plane-parallel plate, which provides high sensitivity of the phase measurement. Detection of light transmitted through the plane-parallel plate with a position sensitive detector (PSD) enables high accurate measurement of the initial angle of incidence to the plane-parallel plate with insensitivity to stray light. The improved parallel plate interferometer achieves a measurement repeatability of 10(-8) rad. (C) 2007 The Optical Society of Japan.

Identificador

http://ir.siom.ac.cn/handle/181231/2168

http://www.irgrid.ac.cn/handle/1471x/10609

Idioma(s)

英语

Fonte

郑德锋;王向朝;Sasaki Osami .,Opt. Rev.,2007,14(5):314-318

Palavras-Chave #angular displacement #interference measurement #plane-parallel plate #laser diode #phase measurement
Tipo

期刊论文