855 resultados para Method development and research
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
This study demonstrates a novel technique of preparing drug colloid probes to determine the adhesion force between the drug salbutamol sulphate (SS) and the surfaces of polymer microparticles to be used as carriers for the dispersion of drug particles from a dry powder inhaler (DPI) formulation. Initially model silica probes of approximately 4 μm size, similar to a drug particle used in DPI formulations, were coated with a saturated SS solution with the aid of capillary forces acting between the silica probe and the drug solution. The developed method of ensuring a smooth and uniform layer of SS on the silica probe was validated using X-Ray Photoelectron Spectroscopy (XPS) and Scanning Electron Microscopy (SEM). Using the same technique, silica microspheres preattached on the AFM cantilever were coated with SS. The adhesion forces between the silica probe and drug coated silica (drug probe) and polymer surfaces (hydrophilic and hydrophobic) were determined. Our experimental results showed that the technique for preparing the drug probe was robust and can be used to determine the adhesion force between hydrophilic/hydrophobic drug probe and carrier surfaces to gain a better understanding on drug carrier adhesion forces in DPI formulations.
Resumo:
This study demonstrates a novel technique of preparing drug colloid probes to determine the adhesion force between a model drug salbutamol sulphate (SS) and the surfaces of polymer microparticles to be used as carriers for the dispersion of drug particles from dry powder inhaler (DPI) formulations. Model silica probes of approximately 4 lm size, similar to a drug particle used in DPI formulations, were coated with a saturated SS solution with the aid of capillary forces acting between the silica probe and the drug solution. The developed method of ensuring a smooth and uniform layer of SS on the silica probe was validated using X-ray Photoelectron Spectroscopy (XPS) and Scanning Electron Microscopy (SEM). Using the same technique, silica microspheres pre-attached on the AFM cantilever were coated with SS. The adhesion forces between the silica probe and drug coated silica (drug probe) and polymer surfaces (hydrophilic and hydrophobic) were determined. Our experimental results showed that the technique for preparing the drug probe was robust and can be used to determine the adhesion force between hydrophilic/ hydrophobic drug probe and carrier surfaces to gain a better understanding on drug carrier adhesion forces in DPI formulations.
Resumo:
Dissertação de Mestrado, Qualidade em Análises, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015
Resumo:
A high performance liquid chromatographic method employing two columns connected in series and separated~y·a.switching valve has been developed for the analysis of the insecticide/ nematicide oxamyl (methyl-N' ,N'-dimethyl-N-[(methylcarbamoyl) oxy]-l-thiooxarnimidate) and two of its metabolites. A variation of this method involving two reverse phase columns was employed to monitor the persistence and translocation of oxamyl in treated peach seedlings. It was possible to simultaneously analyse for oxamyl and its corresponding oxime (methyl-N',N'-dimethyl-N-hydroxy-l-thiooxamimidate}, a major metabolite of oxamyl in plants, without prior cleanup of the samples. The method allowed detection of 0.058 pg oxamyl and 0.035 p.g oxime. On treated peach leaves oxamyl was found to dissipate rapidly during the first two-week period, followed by a period of slow decomposition. Movement of oxamyl or its oxime did not occur in detectable quantities to untreated leaves or to the root or soil. A second variation of the method which employed a size exclusion column as·the first column and a reverse phase column as the second was used to monitor the degradation of oxamyl in treated, planted corn seeds and was suitable for simultaneous analysis of oxamyl, its oxime and dimethylcyanoformamide (DMCF), a metabolite of oxamyl. The method allowed detection of 0.02 pg oxamyl, 0.02 p.g oxime and 0.005 pg DMCF. Oxamyl was found to persist for a period of 5 - 6 weeks, which is long enough to permit oxamyl seedtreatment to be considered as a potential means of protecting young corn plants from nematode attack. Decomposition was found to be more rapid in unsterilized soil than in sterililized soil. DMCF was found to have a nematostatic effect at high concentrations ( 2,OOOpprn), but at lower concentrations no effect on nematode mobility was observed. Oxamyl, on the other hand, was found to reduce the mobility of nematodes at concentrations down to 4 ppm.
Resumo:
While most events related to the International Year of Deserts and Desertification 2006 took mainly a problem-oriented perspective and approach, the Bern Symposium held in May 2006 tried to adopt a more positive attitude by attempting to take stock of experience as well as best and worst practices in the past, both in development practice and in research. Through this deliberate focus on potentials, positive experiences, solutions and pathways, predominant passive and reactive attitudes and hopelessness might be better overcome. The Symposium was organized by CDE, NCCR North-South and Forum SLM.
Resumo:
In situ and simultaneous measurement of the three most abundant isotopologues of methane using mid-infrared laser absorption spectroscopy is demonstrated. A field-deployable, autonomous platform is realized by coupling a compact quantum cascade laser absorption spectrometer (QCLAS) to a preconcentration unit, called trace gas extractor (TREX). This unit enhances CH4 mole fractions by a factor of up to 500 above ambient levels and quantitatively separates interfering trace gases such as N2O and CO2. The analytical precision of the QCLAS isotope measurement on the preconcentrated (750 ppm, parts-per-million, µmole mole−1) methane is 0.1 and 0.5 ‰ for δ13C- and δD-CH4 at 10 min averaging time. Based on repeated measurements of compressed air during a 2-week intercomparison campaign, the repeatability of the TREX–QCLAS was determined to be 0.19 and 1.9 ‰ for δ13C and δD-CH4, respectively. In this intercomparison campaign the new in situ technique is compared to isotope-ratio mass spectrometry (IRMS) based on glass flask and bag sampling and real time CH4 isotope analysis by two commercially available laser spectrometers. Both laser-based analyzers were limited to methane mole fraction and δ13C-CH4 analysis, and only one of them, a cavity ring down spectrometer, was capable to deliver meaningful data for the isotopic composition. After correcting for scale offsets, the average difference between TREX–QCLAS data and bag/flask sampling–IRMS values are within the extended WMO compatibility goals of 0.2 and 5 ‰ for δ13C- and δD-CH4, respectively. This also displays the potential to improve the interlaboratory compatibility based on the analysis of a reference air sample with accurately determined isotopic composition.
Resumo:
National Highway Safety Bureau, Washington, D.C.
Resumo:
National Highway Safety Bureau, Washington, D.C.