933 resultados para Indication bias


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Mortality from invasive meningococcal disease (IMD) has remained stable over the last thirty years and it is unclear whether pre-hospital antibiotherapy actually produces a decrease in this mortality. Our aim was to examine whether pre-hospital oral antibiotherapy reduces mortality from IMD, adjusting for indication bias. Methods: A retrospective analysis was made of clinical reports of all patients (n = 848) diagnosed with IMD from 1995 to 2000 in Andalusia and the Canary Islands, Spain, and of the relationship between the use of pre-hospital oral antibiotherapy and mortality. Indication bias was controlled for by the propensity score technique, and a multivariate analysis was performed to determine the probability of each patient receiving antibiotics, according to the symptoms identified before admission. Data on in-hospital death, use of antibiotics and demographic variables were collected. A logistic regression analysis was then carried out, using death as the dependent variable, and prehospital antibiotic use, age, time from onset of symptoms to parenteral antibiotics and the propensity score as independent variables. Results: Data were recorded on 848 patients, 49 (5.72%) of whom died. Of the total number of patients, 226 had received oral antibiotics before admission, mainly betalactams during the previous 48 hours. After adjusting the association between the use of antibiotics and death for age, time between onset of symptoms and in-hospital antibiotic treatment, pre-hospital oral antibiotherapy remained a significant protective factor (Odds Ratio for death 0.37, 95% confidence interval 0.15–0.93). Conclusion: Pre-hospital oral antibiotherapy appears to reduce IMD mortality.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The progression of liver fibrosis in chronic hepatitis C has long been considered to be independent from viral genotypes. However, recent studies suggest an association between Hepatitis C virus (HCV) genotype 3 and accelerated liver disease progression. We completed a systematic review and meta-analysis of studies evaluating the association between HCV genotypes and fibrosis progression. PubMed, Embase and ISI Web of Knowledge databases were searched for cohort, cross-sectional and case-control studies on treatment-naïve HCV-infected adults in which liver fibrosis progression rate (FPR) was assessed by the ratio of fibrosis stage in one single biopsy to the duration of infection (single-biopsy studies) or from the change in fibrosis stage between two biopsies (paired biopsies studies). A random effect model was used to derive FPR among different HCV genotypes. Eight single-biopsy studies (3182 patients, mean/median duration of infection ranging from 9 to 21 years) and eight paired biopsies studies (mean interval between biopsies 2-12 years) met the selection criteria. The odds ratio for the association of genotype 3 with accelerated fibrosis progression was 1.52 (95% CI 1.12-2.07, P = 0.007) in single-biopsy studies and 1.37 (95% CI 0.87-2.17, P = 0.17) in paired biopsy studies. In conclusion, viral genotype 3 was associated with faster fibrosis progression in single-biopsy studies. This observation may have important consequences on the clinical management of genotype 3-infected patients. The association was not significant in paired biopsies studies, although the latter may be limited by important indication bias, short observation time and small sample size.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Les scores de propension (PS) sont fréquemment utilisés dans l’ajustement pour des facteurs confondants liés au biais d’indication. Cependant, ils sont limités par le fait qu’ils permettent uniquement l’ajustement pour des facteurs confondants connus et mesurés. Les scores de propension à hautes dimensions (hdPS), une variante des PS, utilisent un algorithme standardisé afin de sélectionner les covariables pour lesquelles ils vont ajuster. L’utilisation de cet algorithme pourrait permettre l’ajustement de tous les types de facteurs confondants. Cette thèse a pour but d’évaluer la performance de l’hdPS vis-à-vis le biais d’indication dans le contexte d’une étude observationnelle examinant l’effet diabétogénique potentiel des statines. Dans un premier temps, nous avons examiné si l’exposition aux statines était associée au risque de diabète. Les résultats de ce premier article suggèrent que l’exposition aux statines est associée avec une augmentation du risque de diabète et que cette relation est dose-dépendante et réversible dans le temps. Suite à l’identification de cette association, nous avons examiné dans un deuxième article si l’hdPS permettait un meilleur ajustement pour le biais d’indication que le PS; cette évaluation fut entreprise grâce à deux approches: 1) en fonction des mesures d’association ajustées et 2) en fonction de la capacité du PS et de l’hdPS à sélectionner des sous-cohortes appariées de patients présentant des caractéristiques similaires vis-à-vis 19 caractéristiques lorsqu’ils sont utilisés comme critère d’appariement. Selon les résultats présentés dans le cadre du deuxième article, nous avons démontré que l’évaluation de la performance en fonction de la première approche était non concluante, mais que l’évaluation en fonction de la deuxième approche favorisait l’hdPS dans son ajustement pour le biais d’indication. Le dernier article de cette thèse a cherché à examiner la performance de l’hdPS lorsque des facteurs confondants connus et mesurés sont masqués à l’algorithme de sélection. Les résultats de ce dernier article indiquent que l’hdPS pourrait, au moins partiellement, ajuster pour des facteurs confondants masqués et qu’il pourrait donc potentiellement ajuster pour des facteurs confondants non mesurés. Ensemble ces résultats indiquent que l’hdPS serait supérieur au PS dans l’ajustement pour le biais d’indication et supportent son utilisation lors de futures études observationnelles basées sur des données médico-administratives.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The progression of liver fibrosis in chronic hepatitis C has long been considered to be independent from viral genotypes. However, recent studies suggest an association between Hepatitis C virus (HCV) genotype 3 and accelerated liver disease progression. We completed a systematic review and meta-analysis of studies evaluating the association between HCV genotypes and fibrosis progression. PubMed, Embase and ISI Web of Knowledge databases were searched for cohort, cross-sectional and case-control studies on treatment-naïve HCV-infected adults in which liver fibrosis progression rate (FPR) was assessed by the ratio of fibrosis stage in one single biopsy to the duration of infection (single-biopsy studies) or from the change in fibrosis stage between two biopsies (paired biopsies studies). A random effect model was used to derive FPR among different HCV genotypes. Eight single-biopsy studies (3182 patients, mean/median duration of infection ranging from 9 to 21 years) and eight paired biopsies studies (mean interval between biopsies 2-12 years) met the selection criteria. The odds ratio for the association of genotype 3 with accelerated fibrosis progression was 1.52 (95% CI 1.12-2.07, P = 0.007) in single-biopsy studies and 1.37 (95% CI 0.87-2.17, P = 0.17) in paired biopsy studies. In conclusion, viral genotype 3 was associated with faster fibrosis progression in single-biopsy studies. This observation may have important consequences on the clinical management of genotype 3-infected patients. The association was not significant in paired biopsies studies, although the latter may be limited by important indication bias, short observation time and small sample size.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: A number, of studies have consistently found that a mother's mental health (particularly her level of depression) is a strong predictor of mental health problems experienced by her child(ren). However, the validity of this finding is in doubt because the majority of these studies have relied on maternal reports as indicators of children's behavior. Method: This prospective, longitudinal study examines data an the mental health of the mother from prior to the birth of her child to when the child reaches 14 years of age. Child behavior is measured at 14 years of age using reports from mother and child. Mother and child responses are compared to provide an indication of the possible magnitude of maternal observation bias in the reporting of child behavior problems. Results: Anxious and/or depressed mothers tend to report more cases of child behavior problems than do their mentally healthy counterparts or children themselves. Differences between mothers and youths In reporting behavior problems appear to be related to the mothers' mental health. Conclusions: Current maternal mental health impairment appears to have a substantial effect on the reporting of child behavior problems by the mother, thereby raising questions about the validity of reports of child behavior by persons who are currently emotionally distressed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Extensive research has examined attentional bias for threat in anxious adults and school-aged children but it is unclear when this anxiety-related bias is first established. This study uses eyetracking technology to assess attentional bias in a sample of 83 children aged 3 or 4 years. Of these, 37 (19 female) met criteria for an anxiety disorder and 46 (30 female) did not. Gaze was recorded during a free-viewing task with angry-neutral face pairs presented for 1250 ms. There was no indication of between-group differences in threat bias, with both anxious and non-anxious groups showing vigilance for angry faces as well as longer dwell times to angry over neutral faces. Importantly, however, the anxious participants spent significantly less time looking at the faces overall, when compared to the non-anxious group. The results suggest that both anxious and non-anxious preschool-aged children preferentially attend to threat but that anxious children may be more avoidant of faces than non-anxious children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Ophira Mini Sling System involves anchoring a midurethral, low-tension tape to the obturator internus muscles bilaterally at the level of the tendinous arc. Success rates in different subsets of patients are still to be defined. This work aims to identify which factors influence the 2-year outcomes of this treatment. Analysis was based on data from a multicenter study. Endpoints for analysis included objective measurements: 1-h pad-weight (PWT), and cough stress test (CST), and questionnaires: International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) and Urinary Distress Inventory (UDI)-6. A logistic regression analysis evaluated possible risk factors for failure. In all, 124 female patients with stress urinary incontinence (SUI) underwent treatment with the Ophira procedure. All patients completed 1 year of follow-up, and 95 complied with the 2-year evaluation. Longitudinal analysis showed no significant differences between results at 1 and 2 years. The 2-year overall objective results were 81 (85.3%) patients dry, six (6.3%) improved, and eight (8.4%) incontinent. A multivariate analysis revealed that previous anti-incontinence surgery was the only factor that significantly influenced surgical outcomes. Two years after treatment, women with previous failed surgeries had an odds ratio (OR) for treatment failure (based on PWT) of 4.0 [95% confidence interval (CI) 1.02-15.57). The Ophira procedure is an effective option for SUI treatment, with durable good results. Previous surgeries were identified as the only significant risk factor, though previously operated patients showed an acceptable success rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims. A model-independent reconstruction of the cosmic expansion rate is essential to a robust analysis of cosmological observations. Our goal is to demonstrate that current data are able to provide reasonable constraints on the behavior of the Hubble parameter with redshift, independently of any cosmological model or underlying gravity theory. Methods. Using type Ia supernova data, we show that it is possible to analytically calculate the Fisher matrix components in a Hubble parameter analysis without assumptions about the energy content of the Universe. We used a principal component analysis to reconstruct the Hubble parameter as a linear combination of the Fisher matrix eigenvectors (principal components). To suppress the bias introduced by the high redshift behavior of the components, we considered the value of the Hubble parameter at high redshift as a free parameter. We first tested our procedure using a mock sample of type Ia supernova observations, we then applied it to the real data compiled by the Sloan Digital Sky Survey (SDSS) group. Results. In the mock sample analysis, we demonstrate that it is possible to drastically suppress the bias introduced by the high redshift behavior of the principal components. Applying our procedure to the real data, we show that it allows us to determine the behavior of the Hubble parameter with reasonable uncertainty, without introducing any ad-hoc parameterizations. Beyond that, our reconstruction agrees with completely independent measurements of the Hubble parameter obtained from red-envelope galaxies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report first results from an analysis based on a new multi-hadron correlation technique, exploring jet-medium interactions and di-jet surface emission bias at the BNL Relativistic Heavy Ion Collider (RHIC). Pairs of back-to-back high-transverse-momentum hadrons are used for triggers to study associated hadron distributions. In contrast with two-and three-particle correlations with a single trigger with similar kinematic selections, the associated hadron distribution of both trigger sides reveals no modification in either relative pseudorapidity Delta eta or relative azimuthal angle Delta phi from d + Au to central Au + Au collisions. We determine associated hadron yields and spectra as well as production rates for such correlated back-to-back triggers to gain additional insights on medium properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We theoretically investigate negative differential resistance (NDR) for ballistic transport in semiconducting armchair graphene nanoribbon (aGNR) superlattices (5 to 20 barriers) at low bias voltages V(SD) < 500 mV. We combine the graphene Dirac Hamiltonian with the Landauer-Buttiker formalism to calculate the current I(SD) through the system. We find three distinct transport regimes in which NDR occurs: (i) a ""classical"" regime for wide layers, through which the transport across band gaps is strongly suppressed, leading to alternating regions of nearly unity and zero transmission probabilities as a function of V(SD) due to crossing of band gaps from different layers; (ii) a quantum regime dominated by superlattice miniband conduction, with current suppression arising from the misalignment of miniband states with increasing V(SD); and (iii) a Wannier-Stark ladder regime with current peaks occurring at the crossings of Wannier-Stark rungs from distinct ladders. We observe NDR at voltage biases as low as 10 mV with a high current density, making the aGNR superlattices attractive for device applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A numerical renormalization-group study of the conductance through a quantum wire containing noninteracting electrons side-coupled to a quantum dot is reported. The temperature and the dot-energy dependence of the conductance are examined in the light of a recently derived linear mapping between the temperature-dependent conductance and the universal function describing the conductance for the symmetric Anderson model of a quantum wire with an embedded quantum dot. Two conduction paths, one traversing the wire, the other a bypass through the quantum dot, are identified. A gate potential applied to the quantum wire is shown to control the current through the bypass. When the potential favors transport through the wire, the conductance in the Kondo regime rises from nearly zero at low temperatures to nearly ballistic at high temperatures. When it favors the dot, the pattern is reversed: the conductance decays from nearly ballistic to nearly zero. When comparable currents flow through the two channels, the conductance is nearly temperature independent in the Kondo regime, and Fano antiresonances in the fixed-temperature plots of the conductance as a function of the dot-energy signal interference between them. Throughout the Kondo regime and, at low temperatures, even in the mixed-valence regime, the numerical data are in excellent agreement with the universal mapping.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal dependence of the zero-bias conductance for the single electron transistor is the target of two independent renormalization-group approaches, both based on the spin-degenerate Anderson impurity model. The first approach, an analytical derivation, maps the Kondo-regime conductance onto the universal conductance function for the particle-hole symmetric model. Linear, the mapping is parametrized by the Kondo temperature and the charge in the Kondo cloud. The second approach, a numerical renormalization-group computation of the conductance as a function the temperature and applied gate voltages offers a comprehensive view of zero-bias charge transport through the device. The first approach is exact in the Kondo regime; the second, essentially exact throughout the parametric space of the model. For illustrative purposes, conductance curves resulting from the two approaches are compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ""Short Cognitive Performance Test"" (Syndrom Kurztest, SKT) is a cognitive screening battery designed to detect memory and attention deficits. The aim of this study was to evaluate the diagnostic accuracy of the SKT as a screening tool for mild cognitive impairment (MCI) and dementia. A total of 46 patients with Alzheimer`s disease (AD), 82 with MCI, and 56 healthy controls were included in the study. Patients and controls were allocated into two groups according to educational level (< 8 years or > 8 years). ROC analyses suggested that the SKT adequately discriminates AD from non-demented subjects (MCI and controls), irrespective of the education group. The test had good sensitivity to discriminate MCI from unimpaired controls in the sub-sample of individuals with more than 8 years of schooling. Our findings suggest that the SKT is a good screening test for cognitive impairment and dementia. However, test results must be interpreted with caution when administered to less-educated individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a series of depositions of titanium nitride (TiN) films on M2 and D2 steel substrates were conducted in a Triode Magnetron Sputtering chamber. The temperature; gas flow and pressure were kept constant during each run. The substrate bias was either decreased or increased in a sequence of steps. Residual stress measurements were later conducted through the grazing X-ray diffraction method. Different incident angles were used in order to change the penetration depth and to obtain values of residual stress at different film depths. A model described by Dolle was adapted as an attempt to calculate the values of residual stress at each incident angle as a function of the value from each individual layer. Stress results indicated that the decrease in bias voltage during the deposition has produced compressive residual stress gradients through the film thickness. On the other hand, much less pronounced gradients were found in one of the films deposited with increasing bias voltage. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

TiAlN films were deposited on AISI O1 tool steel using a triode magnetron sputtering system. The bias voltage effect on the composition, thickness, crystallography, microstructure, hardness and adhesion strength was investigated. The coatings thickness and elemental composition analyses were carried out using scanning electron microscopy (SEM) together with energy dispersive X-ray (EDS). The re-sputtering effect due to the high-energy ions bombardment on the film surface influenced the coatings thickness. The films crystallography was investigated using X-ray diffraction characterization. The X-ray diffraction (XRD) data show that TiAlN coatings were crystallized in the cubic NaCl B1 structure, with orientations in the {111}, {200} {220} and {311} crystallographic planes. The surface morphology (roughness and grain size) of TiAlN coatings was investigated by atomic force microscopy (AFM). By increasing the substrate bias voltage from -40 to -150 V, hardness decreased from 32 GPa to 19 GPa. Scratch tester was used for measuring the critical loads and for measuring the adhesion. (C) 2011 Elsevier B. V. All rights reserved.