983 resultados para HPLC-ELSD


Relevância:

60.00% 60.00%

Publicador:

Resumo:

目的:建立那保胶囊(黄芪、当归、延胡索、白花蛇舌草、铁棒锤等)的质量标准。方法:采用TLC对处方中当归、延胡索及白花蛇舌草进行鉴别,对毒性药材铁棒锤进行限量检查,采用高效液相色谱-蒸发光散射检测器(HPLC-ELSD)法测定黄芪甲苷的含量。结果:TLC鉴别分离度好,专属性强;铁棒锤中乌头碱含量不超过规定;黄芪甲苷在1~10μg的范围内线性关系良好(r=0.9990),平均回收率为99.05(RSD=2.48,n=6)。结论:所建立的质量标准方法可靠、准确、专属性强,可有效控制那保胶囊的质量。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

目的:采用高效液相-蒸发光散射检测器(HPLC-ELSD)法测定藏药那保胶囊中黄芪甲苷的含量。方法:色谱柱为KromasilC_(18)柱(4.6mm×250mm,5μm);流动相为乙腈-水(36:64);ELSD(蒸发光散射检测器)检测。结果:黄芪甲苷在1-10μg范围内具良好的线性关系(r=0.999),平均回收率为99.05,RSD为2.48%。结论:该法简便可行,重复性好,适用于那保胶囊的质量控制。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La réduction de la taille des particules jusqu’à l’obtention de nanocristaux est l’une des approches utilisées afin d’améliorer la pénétration cutanée des médicaments à usage topique. Nous proposons que la fabrication d’une formulation semi solide (hydrogel) à base de nanosuspension de docosanol, aboutira à une diffusion du principe actif supérieure à celle du produit commercial Abreva®, à travers des membranes synthétiques de polycarbonates. Le broyage humide est la technique proposée pour la production des nanoparticules de docosanol. Nous proposons aussi la préparation d’une formulation semi-solide (hydrogel) à usage topique à partir de la nanosuspension de docosanol. La nanosuspension de docosanol est obtenue par dispersion du docosanol en solution aqueuse en présence du polymère stabilisant hydroxypropylcellulose (HPC) et du surfactant laurylsulfate de sodium (SDS) suivi d’un broyage humide à faible ou à haute énergie. L’hydrogel de docosanol nanoformulé est préparé à l’aide de la nanosuspension de docosanol qui subit une gélification par le carbopol Ultrez 21 sous agitation mécanique suivie d’une neutralisation au triéthanolamine TEA. La taille des particules de la nanosuspension et de l’hydrogel a été déterminée par diffusion dynamique de la lumière (DLS). Une méthode analytique de chromatographie liquide à haute performance (HPLC) munie d’un détecteur évaporatif (ELSD) a été développée et validée pour évaluer la teneur de docosanol dans les préparations liquides, dans les différentes nanosuspensions et dans les hydrogels de docosanol. L’état de cristallinité des nanocristaux dans la nanosuspension et dans l’hydrogel a été étudié par calorimétrie différentielle à balayage. La morphologie de la nanosuspension et de l’hydrogel de docosanol a été examinée par microscopie électronique à balayage (MEB). Les propriétés rhéologiques et de stabilité physique à différentes températures ont été aussi étudiées pour la formulation semi-solide (hydrogel). De même, la libération in vitro du docosanol contenu dans l’hydrogel et dans le produit commercial Abreva® a été étudiée à travers deux membranes de polycarbonates de taille de pores 400 et 800 nm. Dans le cas de nanosuspensions, des cristaux de docosanol de taille nanométrique ont été produits avec succès par broyage humide. Les nanoparticules de tailles variant de 197 nm à 312 nm ont été produites pour des pourcentages différents en docosanol, en polymère HPC et en surfactant SDS. Après lyophilisation, une augmentation de la taille dépendant de la composition de la formulation a été observée tout en restant dans la gamme nanométrique pour la totalité presque des formulations étudiées. Dans le cas des hydrogels examinés, la taille moyenne des particules de docosanol est maintenue dans la gamme nanométrique avant et après lyophilisation. L’analyse thermique des mélanges physiques, des nanosuspensions et des hydrogels de docosanol a révélé la conservation de l’état de cristallinité des nanocristaux de docosanol après broyage et aussi après gélification. L’examen par microscopie électronique à balayage (MEB) a montré que la nanosuspension et l’hydrogel ont tous deux une morphologie régulière et les nanoparticules ont une forme sphérique. De plus les nanoparticules de la nanosuspension ont presque la même taille inférieure à 300 nm en accord avec le résultat obtenu par diffusion dynamique de la lumière (DLS). Les nanoparticules de l’hydrogel ont une légère augmentation de taille par rapport à celle de la nanosuspension, ce qui est en accord avec les mesures de DLS. D’après les mesures rhéologiques, l’hydrogel de docosanol a un comportement pseudoplastique et un faible degré de thixotropie. L’étude de stabilité physique a montré que les formulations d’hydrogel sont stables à basse température (5°C) et à température ambiante (21°C) pendant une période d’incubation de 13 semaines et instable au-delà de 30°C après deux semaines. La méthode HPLC-ELSD a révélé des teneurs en docosanol comprises entre 90% et 110% dans le cas des nanosuspensions et aux alentours de 100% dans le cas de l’hydrogel. L’essai de diffusion in vitro a montré qu’il y a diffusion de docosanol de l’hydrogel à travers les membranes de polycarbonates, qui est plus marquée pour celle de pore 800 nm, tandis que celui du produit commercial Abreva® ne diffuse pas. Le broyage humide est une technique bien adaptée pour la préparation des nanosuspensions docosanol. Ces nanosuspensions peuvent être utilisée comme base pour la préparation de l’hydrogel de docosanol nanoformulé.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Quantification of the lipid content in liposomal adjuvants for subunit vaccine formulation is of extreme importance, since this concentration impacts both efficacy and stability. In this paper, we outline a high performance liquid chromatography-evaporative light scattering detector (HPLC-ELSD) method that allows for the rapid and simultaneous quantification of lipid concentrations within liposomal systems prepared by three liposomal manufacturing techniques (lipid film hydration, high shear mixing, and microfluidics). The ELSD system was used to quantify four lipids: 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC), cholesterol, dimethyldioctadecylammonium (DDA) bromide, and D-(+)-trehalose 6,6′-dibehenate (TDB). The developed method offers rapidity, high sensitivity, direct linearity, and a good consistency on the responses (R2 > 0.993 for the four lipids tested). The corresponding limit of detection (LOD) and limit of quantification (LOQ) were 0.11 and 0.36 mg/mL (DMPC), 0.02 and 0.80 mg/mL (cholesterol), 0.06 and 0.20 mg/mL (DDA), and 0.05 and 0.16 mg/mL (TDB), respectively. HPLC-ELSD was shown to be a rapid and effective method for the quantification of lipids within liposome formulations without the need for lipid extraction processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Combined effects of hydrogen and air flow rates on the peak response of selected neutral lipid classes (triacylglycerol, diacylglycerol, monoacylglycerol, free fatty acids, and ethyl esters) were studied to optimize and calibrate the Iatroscan Mk-6s Chromarod system for the qualitative and quantitative analysis of lipid classes by thin-layer chromatography (TLC) with flame ionization detection in fish oil during the transesterification process. Air flow rate of 2 L/min, hydrogen flow rate of 150-160 mL/min, and scan rate of 30 s/rod were found to be the optimum conditions. All samples were also analyzed by high performance liquid chromatography (HPLC) with evaporative light scattering detection. Quantitative results obtained by TLC with the flame ionization detection method were comparable to those obtained from HPLC with evaporative light scattering detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-performance liquid chromatography coupled with solid phase extraction method was developed for determination of isofraxidin in rat plasma after oral administration of Acanthopanax senticosus extract (ASE), and pharmacokinetic parameters of isofraxidin either in ASE or pure compound were measured. The HPLC analysis was performed on a Dikma Diamonsil RP(18) column (4.6 mm x 150 mm, 5 microm) with the isocratic elution of solvent A (acetonitrile) and solvent B (0.1% aqueous phosphoric acid, v/v) (A : B = 22 : 78) and the detection wavelength was set at 343 nm. The calibration curve was linear over the range of 0.156-15.625 microg/ml. The limit of detection was 60 ng/ml. The intra-day precision was 5.8%, and the inter-day precision was 6.0%. The recovery was 87.30+/-1.73%. When the dosage of ASE is equal to pure compound caculated by the amount of isofraxidin, it has been found to have two maximum concentrations in plasma while the pure compound only showed one peak in the plasma concentration-time curve. The determined content of isofraxidin in plasma after oral administration of ASE is the total contents of free isofraxidin and its precursors in ASE in vitro. The pharmacokinetic characteristics of ASE showed the priority of the extract and the properities of traditional Chinese medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC with SPE method has been developed for analysis of constituents in rat blood after oral administration of the extract of Acanthopanax senticosus (ASE). The plasma sample was prepared by SPE method equipped with Oasis HLB cartridge (3cc, 60 mg). The analysis was performed on a Dikma Diamonsil RP(18) column (4.6 mmx150 mm, 5 microm) with the gradient elution of solvent A (ACN) and solvent B (0.1% aqueous phosphoric acid, v/v) and the detection wavelength was set at 270 nm. The calibration curve was linear over the range of 0.156-15.625 microg/mL. The LOD was 60 ng/mL. The intraday precision was less than 5.80%, and the interday precision was less than 6.0%. The recovery was (87.30 +/- 1.73)%. As a result, 19 constituents were detected in rat plasma after oral administration of the ASE, including 11 original compounds in ASE and eight metabolites, and three of the metabolites originated from syringin in ASE. Six constituents were identified by comparing with the corresponding reference compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reactive oxygen species are generated during ischaemia-reperfusion of tissue. Oxidation of thymidine by hydroxyl radicals (HO) leads to the formation of 5,6-dihydroxy-5,6-dihydrothymidine (thymidine glycol). Thymidine glycol is excreted in urine and can be used as biomarker of oxidative DNA damage. Time dependent changes in urinary excretion rates of thymidine glycol were determined in six patients after kidney transplantation and in six healthy controls. A new analytical method was developed involving affinity chromatography and subsequent reverse-phase high-performance liquid chromatography (RP-HPLC) with a post-column chemical reaction detector and endpoint fluorescence detection. The detection limit of this fluorimetric assay was 1.6 ng thymidine glycol per ml urine, which corresponds to about half of the physiological excretion level in healthy control persons. After kidney transplantation the urinary excretion rate of thymidine glycol increased gradually reaching a maximum around 48 h. The excretion rate remained elevated until the end of the observation period of 10 days. Severe proteinuria with an excretion rate of up to 7.2 g of total protein per mmol creatinine was also observed immediately after transplantation and declined within the first 24 h of allograft function (0.35 + 0.26 g/mmol creatinine). The protein excretion pattern, based on separation of urinary proteins on sodium dodecyl sulphate-polyacrylamide gel electrophorosis (SDS-PAGE), as well as excretion of individual biomarker proteins, indicated nonselective glomerular and tubular damage. The increased excretion of thymidine glycol after kidney transplantation may be explained by ischaemia-reperfusion induced oxidative DNA damage of the transplanted kidney.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method has been developed for the quantification of 2-hydroxyethylated cysteine resulting as adduct in blood proteins after human exposure to ethylene oxide, by reversed-phase HPLC with fluorometric detection. The specific adduct is analysed in albumin and in globin. After isolation of albumin and globin from blood, acid hydrolysis of the protein and precolumn derivatisation of the digest with 9-fluorenylmethoxycarbonylchloride, the levels of derivatised S-hydroxyethylcysteine are analysed by RP-HPLC and fluorescence detection, with a detection limit of 8 nmol/g protein. Background levels of S-hydroxyethylcysteine were quantified in both albumin and globin, under special consideration of the glutathione transferase GSTT1 and GSTM1 polymorphisms. GSTT1 polymorphism had a marked influence on the physiological background alkylation of cysteine. While S-hydroxyethylcysteine levels in "non-conjugators" were between 15 and 50 nmol/g albumin, "low conjugators" displayed levels between 8 and 21 nmol/g albumin, and "high conjugators" did not show levels above the detection limit. The human GSTM1 polymorphism had no apparent effect on background levels of blood protein 2-hydroxyethylation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A combined data matrix consisting of high performance liquid chromatography–diode array detector (HPLC–DAD) and inductively coupled plasma-mass spectrometry (ICP-MS) measurements of samples from the plant roots of the Cortex moutan (CM), produced much better classification and prediction results in comparison with those obtained from either of the individual data sets. The HPLC peaks (organic components) of the CM samples, and the ICP-MS measurements (trace metal elements) were investigated with the use of principal component analysis (PCA) and the linear discriminant analysis (LDA) methods of data analysis; essentially, qualitative results suggested that discrimination of the CM samples from three different provinces was possible with the combined matrix producing best results. Another three methods, K-nearest neighbor (KNN), back-propagation artificial neural network (BP-ANN) and least squares support vector machines (LS-SVM) were applied for the classification and prediction of the samples. Again, the combined data matrix analyzed by the KNN method produced best results (100% correct; prediction set data). Additionally, multiple linear regression (MLR) was utilized to explore any relationship between the organic constituents and the metal elements of the CM samples; the extracted linear regression equations showed that the essential metals as well as some metallic pollutants were related to the organic compounds on the basis of their concentrations