994 resultados para Grabowsky Power Wagon Company
Resumo:
Mode of access: Internet.
Resumo:
Editor: 1919- S.A. Phillips.
Resumo:
Power distribution automation and control are import-ant tools in the current restructured electricity markets. Unfortunately, due to its stochastic nature, distribution systems faults are hardly avoidable. This paper proposes a novel fault diagnosis scheme for power distribution systems, composed by three different processes: fault detection and classification, fault location, and fault section determination. The fault detection and classification technique is wavelet based. The fault-location technique is impedance based and uses local voltage and current fundamental phasors. The fault section determination method is artificial neural network based and uses the local current and voltage signals to estimate the faulted section. The proposed hybrid scheme was validated through Alternate Transient Program/Electromagentic Transients Program simulations and was implemented as embedded software. It is currently used as a fault diagnosis tool in a Southern Brazilian power distribution company.
Resumo:
Many studies have investigated the prospects for returns, the budgetary and financing background and energy management effects of the new nuclear power plant units to be built at Paks. This document seeks to complement previous economics-based studies by adding a new criterion. The key question in our analysis is whether the power plant company will be capable of independent operations in an economic sense - or will its survival depend on further additional aid by the owner, i.e. via the central budget, after its commissioning? We shall examine from a corporate perspective in what ways the already disclosed financing terms and conditions may affect the everyday operations of the power plant company.
Resumo:
This paper presents a methodology to establish investment and trading strategies of a power generation company. These strategies are integrated in the ITEM-Game simulator in order to test their results when played against defined strategies used by other players. The developed strategies are focused on investment decisions, although trading strategies are also implemented to obtain base case results. Two cases are studied considering three players with the same trading strategy. In case 1, all players also have the same investment strategy driven by a market target share. In case 2, player 1 has an improved investment strategy with a target share twice of the target of players 2 and 3. Results put in evidence the influence of the CO2 and fuel prices in the company investment decision. It is also observed the influence of the budget constraint which might prevent the player to take the desired investment decision.
Resumo:
Diplomityön tavoitteena oli löytää voimalaitosprojektin dokumenttien hallinnan epäjatkuvuuskohdat, mikä ne aiheuttaa ja millä toimenpiteillä dokumenttien hallintaa voidaan parantaa. Tietojärjestelmien, tiedon ja dokumenttien hallinnan merkitys kasvaa yhä enenevässä määrin globaalissa verkostoliiketoiminnassa. Tieto on varastoituna voimalaitoksen suunnittelu-, rakentamis- sekä käyttö- ja ylläpitodokumenteissa. Dokumentit pitää pystyä jäljittämään tietojärjestelmistä ajasta ja paikasta riippumatta laitoksen koko elinkaaren ajan. Laitosdokumentaatiota hyödynnetään laitoksen käyttö- ja ylläpitotoimintojen, tuotekehityksen sekä uusien projektien lähtötietona. Haastatteluilla selvitettiin dokumentoinnin tilaa eräässä laajassa hajautetussa voimalaitosprojektissa. Haastattelujen tuloksia ja yrityksen sisäistä dokumentoinnin ohjeistusta vertaamalla havaittiin, että tiedon siirtoa myynniltä projektille tulee kehittää, samoin kuin dokumenttien tarkastus- ja hyväksymiskäytäntöjä. Dokumenttien käytettävyys edellyttää tietojärjestelmien integrointia ja metatietojen määrittelyä. Työn tuloksena on syntynyt karkean tason tietovirtakaavio sekä dokumentoinnin prosessikuvaukset parantamaan yrityksen ja sen alihankkijoiden välistä kommunikaatiota.
Resumo:
Työssä on tutkittu sähköverkkoyhtiön dokumenttien hallintaa, pääosin keskittymällä käytännön dokumentoinnin tilaan ja sen kehittämiseen. Tutkimus perustuu kirjallisuuteen ja haastatteluihin. Kirjallisuuden avulla on selvitetty työn aihepiirin teoriaa. Haastattelujen avulla on kartoitettu dokumentoinnin nykytilaa ja siihen liittyviä ongelmia sekä alalla yleisesti käytössä olevia toimintatapoja. Työssä on käyty läpi dokumenttien hallinnan perusperiaatteet, menetelmät ja dokumentoinnin rooli sähköverkkoyhtiössä. Erityisesti huomiota on kiinnitetty Helsingin Energian HelenVerkko liiketoiminnon dokumentointiin selvittämällä nykytilaa sekä eri yksiköiden vastuualueita ja toimintatapoja. Myös sähköverkkoyhtiön palveluntuottajien roolia on pohdittu dokumentoinnin kannalta. Nykytilanselvityksen perusteella on koottu dokumenttiluettelo, josta ilmenee mitä dokumentteja HelenVerkossa on käytössä. Työssä on esitelty yleisellä tasolla dokumenttienhallintajärjestelmiin liittyviä toiminnallisuuksia sekä kuvattu muutamia referenssiympäristöjä järjestelmien käytöstä. Työn tuloksena on kuvattu sähköverkkoyhtiölle suositeltava dokumenttien hallinnan toimintatapa sekä kuvattu projektisuunnitelman muodossa, miten kyseisessä esimerkkitapauksessa nykytilasta päästään tavoitetilaan. Dokumenttienhallintaprojektin tavoitteena on kehittää HelenVerkon dokumenttien hallintaa toimivammaksi ja käyttöönottaa dokumenttienhallintajärjestelmä.
Resumo:
This paper deals with results of a research and development (R&D) project in cooperation with Electric Power Distribution Company in São Paulo (Brazil) regarding the development and experimental analysis of a new concept of power drive system suitable for application in traction systems of electrical vehicles pulled by electrical motors, which can be powered by urban DC or AC distribution networks. The proposed front-end structure is composed by five boost power cells in interleaving connection, operating in discontinuous conduction mode as AC-DC converter, or as DC-DC converter, in order to provide the proper DC output voltage range required by DC or AC adjustable speed drivers. Therefore, when supplied by single-phase AC distribution networks, and operating as AC-DC converter, it is capable to provide high power factor, reduced harmonic distortion in the input current, complying with the restrictions imposed by the IEC 61000-3-4 standards resulting in significant improvements for the trolleybuses systems efficiency and for the urban distribution network costs. Considering the compliance with input current restrictions imposed by IEC 61000-3-4 standards, two digital control strategies were evaluated. The digital controller has been implemented using a low cost FPGA (XC3S200) and developed totally using a hardware description language VHDL and fixed point arithmetic. Experimental results from a 15 kW low power scale prototype operating in DC and AC conditions are presented, in order to verify the feasibility and performance of the proposed system. © 2009 IEEE.
Resumo:
In an evermore competitive environment, power distribution companies need to continuously monitor and improve the reliability indices of their systems. The network reconfiguration (NR) of a distribution system is a technique that well adapts to this new deregulated environment for it allows improvement of system reliability indices without the onus involved in procuring new equipment. This paper presents a reliability-based NR methodology that uses metaheuristic techniques to search for the optimal network configuration. Three metaheuristics, i.e. Tabu Search, Evolution Strategy, and Differential Evolution, are tested using a Brazilian distribution network and the results are discussed. © 2009 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
Mode of access: Internet.
Resumo:
The fact that most of the large scale solar PV plants are built in arid and semi-arid areas where land availability and solar radiation is high, it is expected the performance of the PV plants in such locations will be affected significantly due to high cell temperature as well as due to soiling. Therefore, it is essential to study how the different PV module technologies will perform in such geographical locations to ensure a consistent and reliable power delivery over the lifetime of the PV power plants. As soiling is strongly dependent on the climatic conditions of a particular location a test station, consisted of about 24 PV modules and a well-equipped weather station, was built within the fences of Scatec’s 75 MW Kalkbult solar PV plant in South Africa. This study was performed to a better understand the effect of soiling by comparing the relative power generation by the cleaned modules to the un-cleaned modules. Such knowledge can enable more quantitative evaluations of the cleaning strategies that are going to be implemented in bigger solar PV power plants. The data collected and recorded from the test station has been analyzed at IFE, Norway using a MatLab script written for this thesis project. This thesis work has been done at IFE, Norway in collaboration with Stellenbosch University in South Africa and Scatec Solar a Norwegian independent power producer company. Generally for the polycrystalline modules it is found that the average temperature corrected efficiency during the period of the experiment has been 15.00±0.08 % and for the thin film-CdTe with ARC is 11.52% and for the thin film without ARC is about 11.13% with standard uncertainty of ±0.01 %. Besides, by comparing the initial relative average efficiency of the polycrystalline-Si modules when all the modules have been cleaned for the first time and the final relative efficiency; after the last cleaning schedule which is when all the reference modules E, F, G, and H have been cleaned for the last time it is found that poly3 performs 2 % and 3 % better than poly1 and poly16 respectively, poly13 performs 1 % better than poly15 as well as poly5 and poly12 performs 1 % and 2 % better than poly10 respectively. Besides, poly5 and poly12 performs a 9 % and 11 % better than poly7. Furthermore, there is no change in performance between poly6 and poly9 as well as poly4 and poly15. However, the increase in performance of poly3 to poly1, poly13 to poly15 as well as poly5 and poly12 to poly10 is insignificant. In addition, it is found that TF22 perform 7% better than the reference un-cleaned module TF24 and similarly; TF21 performs 7% higher than TF23. Furthermore, modules with ARC glass (TF17, TF18, TF19, and TF20) shows that cleaning the modules with only distilled water (TF19) or dry-cleaned after cleaned with distilled water(TF20) decreases the performance of the modules by 5 % and 4 % comparing to its respective reference uncleanedmodules TF17 and TF18 respectively.
Resumo:
This master’s thesis studies the case company’s current purchase invoice process and the challenges that are related to it. Like most of other master’s thesis this study consists of both theoretical- and empirical parts. The purpose of this work is to combine theoretical and empirical parts together so that the theoretical part brings value to the empirical case study. The case company’s main business is frequency converters for both low voltage AC & DC drives and medium voltage AC Drives which are used across all industries and applications. The main focus of this study is on the current invoice process modelling. When modelling the existing process with discipline and care, current challenges can be understood better. Empirical study relays heavily on interviews and existing, yet fragmented, data. This, along with own calculations and analysis, creates the foundation for the empirical part of this master’s thesis.