990 resultados para F AAS
Resumo:
Palladium plus magnesium nitrates with and without Ir, Ru and W were evaluated for the simultaneous determination of As, Cu and Pb in cachaca by graphite furnace atomic absorption spectrometry. For 20 mu L sample, 5 mu L Pd(NO(3))(2) and 3 mu L Mg(NO(3))(2) dispensed together onto the Ir-coated platform of the THGA, analytical curves in the 0-30.0 mu g L(-1) As, 0-1.50 mg L(-1) Cu and 0-60.0 mu g L(-1) Pb were built up and typical linear correlation coefficients were always better than 0.999. The limit of detection was 1.30 mu g L(-1) As, 140 mu g L(-1) Cu and 0.90 mu g L(-1) Pb. As, Cu and Pb contents in 10 cachaca samples agreed with those obtained by ICP-MS. Recoveries of spiked samples varied from 96% to 106% (As), 97% to 112% (Cu) and 92% to 108% (Pb). The relative standard deviation (n = 12) was typically 2.7%, 3.3% and 1.9%. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
O mercúrio é um elemento que ainda necessita constante monitoramento devido sua capacidade tóxica em concentrações em níveis de traço com possibilidade de contaminação e exposição por uma variedade de formas e compostos presentes no ambiente. Esse estudo possuiu como objetivo a obtenção de um procedimento simplificado e eficiente para a determinação de teores de mercúrio em tecidos de rato Wistar a partir da otimização de um método de determinação, utilizando um sistema de geração de vapor frio acoplado a espectrometria de absorção atômica com forno de grafite (CV-GF AAS). Houve a comparação entre métodos de digestão, comparação de métodos de amalgamação, otimização, verificação do método a partir da obtenção de figuras de mérito e análise de amostras de fígado e rins de ratos tratados com exposição crônica ao mercúrio. Os resultados comprovaram que o método de digestão em bloco digestor, a utilização de amalgamação por recobrimento de tubo em ouro em conjunto com rede de ouro e adição pré-análise à solução de simeticona e isopropanol apresentou os melhores resultados, com teores de recuperação médios entre 92 e 114 %, viabilizando a utilização do procedimento proposto.
Resumo:
A determinação de As por espectrometria de absorção atômica com geração de hidretos (HG-AAS) constitui um método simples, sensível, preciso e de baixo custo. Entretanto, essa técnica requer a pré-redução das espécies de As(V), o que se obtém através do uso de agentes redutores como o KI. Em extratos contendo agentes oxidantes, a pré-redução do As é comprometida, como acontece em extratos obtidos pela aplicação do método BCR (acrônimo francês para Community Bureau of Reference) para a extração sequencial de As em sedimentos. O objetivo deste trabalho foi avaliar as condições de redução do As(V) a As(III), de modo a permitir o uso da HG-AAS para a quantificação do arsênio em extratos obtidos a partir do método BCR. Foram avaliadas condições reacionais utilizando KI, L-cisteína e ácido ascórbico. Para cada uma das etapas de extração do método BCR, diferentes condições de pré-redução possibilitaram a detecção quantitativa do As presente. O uso do método BCR para a extração de arsênio em amostras de sedimentos contaminadas e a aplicação das condições de pré-redução do As(V) selecionadas, seguida pela detecção por HG-AAS, forneceram percentagens de recuperação entre 91 e 99 %.
Resumo:
The aim of this work was to compare the performances of the L'vov and integrated platforms in order to overcome the interferences found on lead determination in zidovudine by ET AAS. Pyrolysis and atomization temperatures found with integrated platform were 700 and 1400°C, respectively. The characteristic masses were 12.7 ± 1.2 pg with integrated platform and 11.1 ± 1.3 pg with grooved platform. The ratio between the slopes of zidovudine and aqueous curves shows a decrease in the interferences when the L'vov platform is used (bAZT/b aq = 0.97 ± 0.10) and the detection limit found was 0.03 µg.g-1. That ratio was 0.85 ± 0.07 with the integrated platform.
Resumo:
Mercury is a toxic metal used in a variety of substances over the course history. One of its more dubious uses is in dental amalgam restorations. It is possible to measure very small concentrations of this metal in the urine of exposed subjects by the cold vapor atomic absorption technique. The present work features the validation as an essential tool to confirm the suitability of the analytical method chosen to accomplish such determination. An initial analysis will be carried out in order to evaluate the environmental and occupational levels of exposure to mercury in 39 members of the auxiliary dental staff at public consulting rooms in the city of Araguaína (TO).
Resumo:
A procedure for the simultaneous determination of Cr, Ni, and V in urine by electrothermal atomic absorption spectrometry (ET AAS) was optimized by factorial design, and performed at a pyrolysis and atomization temperatures of 1300 and 2500 ºC, respectively, using 15 µg de Mg(NO3)2 as chemical modifier. Characteristics mass of 14, 6 and 220 ρg and detection limits of the method of 0.07, 0.38 and 0.75 µg L-1 were obtained for Cr, Ni and V respectively. The methodology was validated using a Liphochek Urine Metals Control sample (Bio-Rad) (P=0.05). The methodology was applied to samples of voluntary Venezuelan people, not environmentally exposed to specific emissions, and results ranging from < LOD-1.1 and 1.3-3.3 µg L-1 was observed for Cr and V, respectively, and not detectable levels for Ni.
Resumo:
A simple and fast approach for solid phase extraction is herein described, and used to determine trace amounts of Pb2+ and Cu2+ metal ions. The solid phase support is sodium dodecyl sulfate (SDS)-coated γ-alumina modified with bis(2-hydroxy acetophenone)-1,6-hexanediimine (BHAH) ligand. The adsorbed ions were stripped from the solid phase by 6 mL of 4 M nitric acid as eluent. The eluting solution was analyzed by flame atomic absorption spectrometry (FAAS). The sorption recovery of metal ions was investigated with regard to the effects of pH, amount of ligand, γ-alumina and surfactant and the amount and type of eluent. Complexation of BHAH with Pb2+ or Cu2+ ions was examined via spectrophotometry using the HypSpec program. The detection limit for Cu2+ was 7.9 µg L-1 with a relative standard deviation of 1.67%, while that for Pb2+ was 6.4 µg L-1 with a relative standard deviation of 1.64%. A preconcentration factor of 100 was achieved for these ions. The method was successfully applied to determine analyte concentrations in samples of liver, parsley, cabbage, and water.
Resumo:
This paper describes the evaluation of a method for determination of Cd and Pb in xanthan gum samples by Graphite Furnace Atomic Absorption Spectrometry (GF AAS) using NH4H2PO4 as the chemical modifier. The sample preparation was performed using a reflux system adapted in the digestion tubes. With this system it was possible to increase the temperature of the digester block above the boiling point of the reaction medium, preventing loss of analyte and excessive evaporation of acids during heating. Samples were digested with HNO3 for 3 h in a digester block at 220 ºC. The limits of detection for Cd and Pb were 2.2 and 33.8 ng g-1, respectively. The RSDs for both analytes were, on average, lower than 5.0% and accuracy was verified by recovery tests, yielding values in the 83-100% range.
Resumo:
Este trabalho propõe o desenvolvimento de um procedimento analítico para a determinação em linha de estanho em soluções analíticas empregando a técnica de espectrometria de absorção atômica com nebulização térmica em tubo metálico aquecido na chama (TS-FF-AAS) como alternativa ao uso da chama de óxido nitroso-acetileno em espectrometria de absorção atômica, cujo comburente apresenta um custo elevado frente ao ar comprimido. Foram avaliados parâmetros para a otimização do sistema, tais como: vazão do carregador (ar), volume de amostra injetada e concentração do ácido (HCl). Foi construída curva analítica linear [A= -0,00163 + 0,00319 [Sn], (r= 0,9998)] no intervalo de 10 a 80 mg Sn L-1. O limite de detecção, o desvio padrão relativo (n=12) e a freqüência analítica foram: 1,7 mg L-1 Sn, £ 2,7% and 120 h-1 respectivamente. O sistema TS-FF-AAS é uma alternativa para a determinação de Sn.
Resumo:
Tesis (Doctor en Ciencias con Orientación Terminal en Biología Molecular e Ingeniería Genética) UANL, 2011.
Resumo:
This paper describes the preparation of acid carboxymethylcellulose (CMCH), and the results of a study on the adsorption and preconcentration (using batch and flow-through column methods) of Cd(II), Cu(II), Cr(III), Fe(III), Ni(II) and Zn(II) in ethanol medium. The adsorption capacities for each metallic ion were (in mmol g(-1)) Cd(II) = 0.92; Cu(II) = 1.45; Cr(III) = 1.70; Fe(III) = 1.60; Ni(II) = 1.30; and Zn(II) = 1.10. By means of the flow-through method, a recovery of ca. 100% of the metallic ions adsorbed in a column packed with 2 g of CMCH was found when 5.0 mL of 1.0 mol L-1 hydrochloric acid were used as eluent. An enrichment factor of 20 (100 mt solution containing 50 mu g L-1 of the metallic ions, concentrated to 5.0 mt) was obtained by this preconcentration procedure. The sorption-desorption procedure applied allowed the development of a preconcentration and Flame AAS quantification method of metallic ions in fuel ethanol at trace levels.
Resumo:
5-amino-1,3,4-thiadiazole-2-thiol groups attached on a silica gel surface have been used for adsorption of Cd(II), Co(II), Cu(II), Fe(III), Ni(II), Pb(II) and Zn(II) from aqueous solutions. The adsorption capacities for each metal ion were (in mmol.g(-1)): Cd(II)= 0.35, Co(II)= 0.10, Cu(II)= 0.15, Fe(III)= 0.20, Hg(Il)= 0.46, Ni(II)= 0.16, Pb(II)= 0.13 and Zn(II)= 0.15. The modified silica gel was applied in the preconcentration and quantification of trace level metal ions present in water samples (river, and bog water).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)