925 resultados para ELECTRONEGATIVE-LDL


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Zinc-alpha 2-glycoprotein (ZAG) is a lipid mobilizing factor. Its anti-inflammatory action and expression pattern suggest that ZAG could act by protecting against the obesity-associated disorders. In hemodialysis (HD) patients, ZAG levels were described to be elevated but its effects on markers of inflammation and LDL oxidation are still unclear. We investigated the relationship between ZAG and markers of systemic inflammation and LDL atherogenic modification profile in HD patients. Methods: Forty-three patients regularly on HD were studied and compared to 20 healthy subjects. Plasma ZAG, adiponectin, electronegative LDL [LDL(-)], an atherosclerotic negatively charged LDL subtraction, and anti-LDL(-) autoantibodies levels were measured by ELISA. Markers of inflammation and atherogenic cell recruitment (TNF-alpha, interleukin-6, VCAM-1, ICAM-1, MCP-1 and PAI-1) were also determined. Results: Inflammatory markers and atherogenic cell recruitment were higher in HD patients when compared to healthy subjects. ZAG levels were also higher in HD patients (151.5 +/- 50.1 mg/l vs 54.6 +/- 23.0 mg/l; p<0.0001) and its levels were negatively correlated with TNF-alpha (r= -0.39; p = 0.001) and VCAM-1 (r= -0.52; p<0.0001) and, positively correlated with anti-LDL(-) autoantibodies (r = 038; p = 0.016). On multivariate analyses, plasma ZAG levels were independently associated with VCAM-1 (p = 0.01). Conclusion: ZAG is inversely associated with markers of pro-atherogenic factors linked to systemic inflammation and oxidative stress. Thus, this adipokine may constitute a novel marker of a favorable metabolic profile regarding cardiovascular risk factors in HD population. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dyslipidemias and physicochemical changes in low-density lipoprotein (LDL) are very important factors for the development of coronary artery disease (CAD). However, pathophysiological properties of electronegative low-density lipoprotein [LDL(-)] remain a controversial issue. Our objective was to investigate LDL(-) content in LDL and its subfractions (phenotypes A and B) of subjects with different cardiovascular risk. Seventy-three subjects were randomized into three groups: normolipidemic (N; n = 30) and hypercholesterolemic (HC; n = 33) subjects and patients with CAD (n = 10). After fasting, blood samples were collected and total, dense and light LDL were isolated. LDL(-) content in total LDL and its subfractions was determined by ELISA. LDL(-) content in total LDL was lower in the N group as compared to the HC (P < 0.001) and CAD (P = 0.006) groups. In the total sample and in those of the N, HC, and CAD groups, LDL(-) content in dense LDL was higher than in light LDL (P = 0.001, 0.001, 0.001, and 0.033, respectively) The impact of LDL(-) on cardiovascular risk was reinforced when LDL(-) content in LDL showed itself to have a positive association with total cholesterol (beta = 0.003; P < 0.001), LDL-C (beta = 0.003; p < 0.001), and non-HDL-C (beta = 0.003; P < 0.001) and a negative association with HDL-C (beta = -0.32; P = 0.04). Therefore, LDL(-) is an important biomarker that showed association with the lipid profile and the level of cardiovascular risk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Oxidative modification of low-density lipoprotein (LDL) plays a key role in the pathogenesis of atherosclerosis. LDL(-) is present in blood plasma of healthy subjects and at higher concentrations in diseases with high cardiovascular risk, such as familial hypercholesterolemia or diabetes. Methods: We developed and validated a sandwich ELISA for LDL(-) in human plasma using two monoclonal antibodies against LDL(-) that do not bind to native LDL, extensively copper-oxidized LDL or malondialdehyde-modified LDL. The characteristics of assay performance, such as limits of detection and quantification, accuracy, inter- and intra-assay precision were evaluated. The linearity, interferences and stability tests were also performed. Results: The calibration range of the assay is 0.625-20.0 mU/L at 1: 2000 sample dilution. ELISA validation showed intra- and inter- assay precision and recovery within the required limits for immunoassays. The limits of detection and quantification were 0.423 mU/L and 0.517 mU/L LDL(-), respectively. The intra- and inter- assay coefficient of variation ranged from 9.5% to 11.5% and from 11.3% to 18.9%, respectively. Recovery of LDL(-) ranged from 92.8% to 105.1%. Conclusions: This ELISA represents a very practical tool for measuring LDL(-) in human blood for widespread research and clinical sample use. Clin Chem Lab Med 2008; 46: 1769-75.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Iron supplementation is a common recommendation to chronic kidney disease patients undergoing hemodialysis (HD). However, iron excess is closely associated with lipid peroxidation and, it is well known that electronegative low-density lipoproteins (LDL[-]) are present at higher plasma concentrations in diseases with high cardiovascular risk such as chronic kidney disease. Thus, the aim of this study was to investigate whether ferritin levels are associated with LDL(-) levels in HD patients. Design: This was a cross-sectional study. Setting: This study was conducted from a private clinic in Rio de Janeiro, Brazil. Patients: The study included 27 HD patients and 15 healthy subjects. Methods and Procedures: Twenty-seven HD patients (14 men, 58.6 +/- 10 years, 62.2 +/- 51.4 months on dialysis, and body mass index: 24.4 +/- 4.2 kg/m(2)) were studied and compared with 15 healthy individuals (6 men, 53.8 +/- 15.4 years, body mass index: 24.5 +/- 4.3 kg/m(2)). Serum LDL(-) levels were measured using the enzyme-linked immunosorbent assay method; ferritin levels by commercially available kits, and tumor necrosis factor-alpha, interleukin-6, monocyte chemoattractant protein-1, and plasminogen activator inhibitor-1 were determined with a multiplex assay kit manufactured by R&D Systems. Results: The HD patients presented higher LDL(-) and tumor necrosis factor-alpha levels (0.15 +/- 0.13 U/L and 5.9 +/- 2.3 pg/mL, respectively) than healthy subjects (0.07 +/- 0.05 U/L and 2.3 +/- 1.3 pg/mL, respectively) (P = .0001). The mean ferritin level in HD patients was 1,117.5 +/- 610.4 ng/mL, and 90% of patients showed ferritin levels exceeding 500 ng/mL. We found a positive correlation between LDL(-) and ferritin in the patients (r = 0.48; P = .01), and ferritin was a significant contributor to LDL(-) concentrations independent of inflammation. Conclusions: Excess body iron stores for HD patients was associated with signs of increased oxidative stress, as reflected by increased LDL(-) levels in HD patients. (C) 2012 by the National Kidney Foundation, Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nanopowder management and control of plasma parameters in electronegative SiH4 plasmas were discussed. The spatial profiles of electron and positive/negative ion number densities, electron temperature and charge of the fine particles were obtained. It was found that management of powder charge distribution is also possible through control of the external parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A model for electronegative plasmas containing charged dust or colloidal grains was used. Numerical solutions based on the model demonstrate how a low-pressure diffusion equilibrium of the complex electronegative plasma system is dynamically sustained through plasma particle sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The control of the generation and assembly of the electronegative plasma-grown particles is discussed. Due to the large number of elementary processes of particle creation and loss, electronegative complex plasmas should be treated as open systems where the stationary states are sustained by various particle creation and loss processes in the plasma bulk, on the walls, and on the dust grain surfaces. To be physically self-consistent, ionization, diffusion, electron attachment, recombination, dust charge variation, and dissipation due to electron and ion elastic collisions with neutrals and fine particles, as well as charging collisions with the dust, must be accounted for.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The results of numerical simulation of the equilibrium parameters of a low pressure nanopowder-generating discharge in silane for the plasma enhanced chemical vapor deposition (PECVD) of nanostructured silicon-based films are presented. It is shown that a low electron temperature and a low density of negative SiH3 - ions are favorable for the PECVD process. This opens a possibility to predict the main parameters of the reactive plasma and plasma-nucleated nanoparticles, and hence, to control the quality of silicon nanofilms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cholesterol is considered indispensible for the recruitment and functioning of integrins in focal adhesions for cell migration. However, the physiological cholesterol pools that control integrin trafficking and focal adhesion assembly remain unclear. Using Niemann Pick Type C1 (NPC) mutant cells, which accumulate Low Density lipoprotein (LDL)-derived cholesterol in late endosomes (LE), several recent studies indicate that LDL-cholesterol has multiple roles in regulating focal adhesion dynamics. Firstly, targeting of endocytosed LDL-cholesterol from LE to focal adhesions controls their formation at the leading edge of migrating cells. Other newly emerging literature suggests that this may be coupled to vesicular transport of integrins, Src kinase and metalloproteases from the LE compartment to focal adhesions. Secondly, our recent work identified LDL-cholesterol as a key factor that determines the distribution and ability of several Soluble NSF Attachment Protein (SNAP) Receptor (SNARE) proteins, key players in vesicle transport, to control integrin trafficking to the cell surface and extracellular matrix (ECM) secretion. Collectively, dietary, genetic and pathological changes in cholesterol metabolism may link with efficiency and speed of integrin and ECM cell surface delivery in metastatic cancer cells. This commentary will summarize how direct and indirect pathways enable LDL-cholesterol to modulate cell motility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ratio of the electron attachment coefficient eta to the gas pressure p (reduced to 0 degrees C) evaluated from the Townsend current growth curves in binary mixtures of electronegative gases (SF6, CCl2F2, CO2) and buffer gases (N2, Ar, air) clearly indicate that the eta /p ratios do not scale as the partial pressure of electronegative gas in the mixture. Extensive calculations carried out using data experimentally obtained have shown that the attachment coefficient of the mixture eta mix can be expressed as eta mix= eta (1-exp- beta F/(100-F)) where eta is the attachment coefficient of the 100% electronegative gas, F is the percentage of the electronegative gas in the mixture and beta is a constant. The results of this analysis explain to a high degree of accuracy the data obtained in various mixtures and are in very good agreement with the data deduced by Itoh and co-workers (1980) using the Boltzmann equation method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone mass accrual and maintenance are regulated by a complex interplay between genetic and environmental factors. Recent studies have revealed an important role for the low-density lipoprotein receptor-related protein 5 (LRP5) in this process. The aim of this thesis study was to identify novel variants in the LRP5 gene and to further elucidate the association of LRP5 and its variants with various bone health related clinical characteristics. The results of our studies show that loss-of-function mutations in LRP5 cause severe osteoporosis not only in homozygous subjects but also in the carriers of these mutations, who have significantly reduced bone mineral density (BMD) and increased susceptibility to fractures. In addition, we demonstrated for the first time that a common polymorphic LRP5 variant (p.A1330V) was associated with reduced peak bone mass, an important determinant of BMD and osteoporosis in later life. The results from these two studies are concordant with results seen in other studies on LRP5 mutations and in association studies linking genetic variation in LRP5 with BMD and osteoporosis. Several rare LRP5 variants were identified in children with recurrent fractures. Sequencing and multiplex ligation-dependent probe amplification (MLPA) analyses revealed no disease-causing mutations or whole-exon deletions. Our findings from clinical assessments and family-based genotype-phenotype studies suggested that the rare LRP5 variants identified are not the definite cause of fractures in these children. Clinical assessments of our study subjects with LPR5 mutations revealed an unexpectedly high prevalence of impaired glucose tolerance and dyslipidaemia. Moreover, in subsequent studies we discovered that common polymorphic LRP5 variants are associated with unfavorable metabolic characteristics. Changes in lipid profile were already apparent in pre-pubertal children. These results, together with the findings from other studies, suggest an important role for LRP5 also in glucose and lipid metabolism. Our results underscore the important role of LRP5 not only in bone mass accrual and maintenance of skeletal health but also in glucose and lipid metabolism. The role of LRP5 in bone metabolism has long been studied, but further studies with larger study cohorts are still needed to evaluate the specific role of LRP5 variants as metabolic risk factors.