988 resultados para Digital PCR
Resumo:
Hand, foot and mouth disease (HFMD) is a contagious viral disease that frequently affects infants and children and present with blisters and flu-like symptoms. This disease is caused by a group of enteroviruses such as enterovirus 71 (EV71) and coxsackievirus A16 (CA16). However, unlike other HFMD causing enteroviruses, EV71 have also been shown to be associated with more severe clinical manifestation such as aseptic meningitis, brainstem and cerebellar encephalitis which may lead to cardiopulmonary failure and death. Clinically, HFMD caused by EV71 is indistinguishable from other HFMD causing enteroviruses such as CA16. Molecular diagnosis methods such as the use of real-time PCR has been used commonly for the identification of EV71. In this study, two platforms namely the real-time PCR and the droplet digital PCR were compared for the detection quantitation of known EV71 viral copy number. The results reveal accurate and consistent results between the two platforms. In summary, the droplet digital PCR was demonstrated to be a promising technology for the identification and quantitation of EV71 viral copy number.
Resumo:
Thesis (Master's)--University of Washington, 2015
Resumo:
Schistosomiasis is a chronically debilitating helminth infection with a significant socio-economic and public health impact. Accurate diagnostics play a pivotal role in achieving current schistosomiasis control and elimination goals. However, many of the current diagnostic procedures, which rely on detection of schistosome eggs, have major limitations including lack of accuracy and the inability to detect pre-patent infections. DNA-based detection methods provide a viable alternative to the current tests commonly used for schistosomiasis diagnosis. Here we describe the optimisation of a novel droplet digital PCR (ddPCR) duplex assay for the diagnosis of Schistosoma japonicum infection which provides improved detection sensitivity and specificity. The assay involves the amplification of two specific and abundant target gene sequences in S. japonicum; a retrotransposon (SjR2) and a portion of a mitochondrial gene (nad1). The assay detected target sequences in different sources of schistosome DNA isolated from adult worms, schistosomules and eggs, and exhibits a high level of specificity, thereby representing an ideal tool for the detection of low levels of parasite DNA in different clinical samples including parasite cell free DNA in the host circulation and other bodily fluids. Moreover, being quantitative, the assay can be used to determine parasite infection intensity and, could provide an important tool for the detection of low intensity infections in low prevalence schistosomiasis-endemic areas.
Resumo:
Droplet digital PCR (ddPCR) can be used to detect low frequency mutations in oncogene-driven lung cancer. The range of KRAS point mutations observed in NSCLC necessitates a multiplex approach to efficient mutation detection in circulating DNA. Here we report the design and optimisation of three discriminatory ddPCR multiplex assays investigating nine different KRAS mutations using PrimePCR™ ddPCR™ Mutation Assays and the Bio-Rad QX100 system. Together these mutations account for 95% of the nucleotide changes found in KRAS in human cancer. Multiplex reactions were optimised on genomic DNA extracted from KRAS mutant cell lines and tested on DNA extracted from fixed tumour tissue from a cohort of lung cancer patients without prior knowledge of the specific KRAS genotype. The multiplex ddPCR assays had a limit of detection of better than 1 mutant KRAS molecule in 2,000 wild-type KRAS molecules, which compared favourably with a limit of detection of 1 in 50 for next generation sequencing and 1 in 10 for Sanger sequencing. Multiplex ddPCR assays thus provide a highly efficient methodology to identify KRAS mutations in lung adenocarcinoma.
Resumo:
Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Ciências Farmacêuticas
Resumo:
Con il seguente lavoro di tesi si propone un excursus dell’evoluzione della tecnica che ha permesso l’amplificazione del DNA in laboratorio, spiegandone i principi elementari di base. La scoperta che il DNA è il depositario dell’informazione genica ha aperto la strada a una nuova disciplina: la biologia molecolare, dove molte delle tecniche utilizzate limitano le funzioni naturali degli acidi nucleici. Dalla sua introduzione, la tecnologia PCR ha modificato il modo nel quale l’analisi del DNA viene condotta nei laboratori di ricerca e di diagnostica. Con lo scopo di rilevare direttamente sequenze genomiche specifiche in un campione biologico nasce l’esigenza di avere a disposizione metodologie con un’elevata soglia di sensibilità e specificità. Il primo capitolo di questo elaborato introduce la PCR nella sua prima formulazione. A partire da quantità estremamente ridotte di DNA, questa tecnica di amplificazione in vitro, consente di ottenere rapidamente milioni di molecole identiche della sequenza bersaglio di acido nucleico. A seguire, nel secondo capitolo, verrà trattata un’implementazione della PCR: la real-time PCR. La RT-PCR, introduce nuove opportunità poiché rende possibile la misurazione diretta e la quantificazione della reazione mentre è in atto. Con l’utilizzo di molecole fluorescenti che vengono incorporate nel prodotto in formazione o che si intercalano alla doppia elica, si può monitorare la formazione del prodotto di amplificazione in tempo reale seguendone l’assorbimento con un sistema spettrofotometrico, in un sistema automatizzato che provvede anche alle routine della PCR. Nel terzo e ultimo capitolo si analizza una nuova tecnologia recentemente commercializzata: la PCR in formato digitale. Verranno prese in esame essenzialmente due metodologie, la dPCR su chip e la ddPCR (Droplet Digital Polymerase Chain Reaction).
Resumo:
Serial quantification of BCR-ABL1 mRNA is an important therapeutic indicator in chronic myeloid leukaemia, but there is a substantial variation in results reported by different laboratories. To improve comparability, an internationally accepted plasmid certified reference material (CRM) was developed according to ISO Guide 34:2009. Fragments of BCR-ABL1 (e14a2 mRNA fusion), BCR and GUSB transcripts were amplified and cloned into pUC18 to yield plasmid pIRMM0099. Six different linearised plasmid solutions were produced with the following copy number concentrations, assigned by digital PCR, and expanded uncertainties: 1.08±0.13 × 10(6), 1.08±0.11 × 10(5), 1.03±0.10 × 10(4), 1.02±0.09 × 10(3), 1.04±0.10 × 10(2) and 10.0±1.5 copies/μl. The certification of the material for the number of specific DNA fragments per plasmid, copy number concentration of the plasmid solutions and the assessment of inter-unit heterogeneity and stability were performed according to ISO Guide 35:2006. Two suitability studies performed by 63 BCR-ABL1 testing laboratories demonstrated that this set of 6 plasmid CRMs can help to standardise a number of measured transcripts of e14a2 BCR-ABL1 and three control genes (ABL1, BCR and GUSB). The set of six plasmid CRMs is distributed worldwide by the Institute for Reference Materials and Measurements (Belgium) and its authorised distributors (https://ec.europa.eu/jrc/en/reference-materials/catalogue/; CRM code ERM-AD623a-f).
Resumo:
This study has provided further understanding of the pathogenesis of EV71, one of the major etiological agents associated with significant mortality in Hand, Foot and Mouth disease. Elucidating the host-pathogen interaction and the mechanism that the virus uses to bypass host defence systems to establish infection will aid in the development of potential antiviral therapeutics against EV71.
Resumo:
Motivated by needs in molecular diagnostics and advances in microfabrication, researchers started to seek help from microfluidic technology, as it provides approaches to achieve high throughput, high sensitivity, and high resolution. One strategy applied in microfluidics to fulfill such requirements is to convert continuous analog signal into digitalized signal. One most commonly used example for this conversion is digital PCR, where by counting the number of reacted compartments (triggered by the presence of the target entity) out of the total number of compartments, one could use Poisson statistics to calculate the amount of input target.
However, there are still problems to be solved and assumptions to be validated before the technology is widely employed. In this dissertation, the digital quantification strategy has been examined from two angles: efficiency and robustness. The former is a critical factor for ensuring the accuracy of absolute quantification methods, and the latter is the premise for such technology to be practically implemented in diagnosis beyond the laboratory. The two angles are further framed into a “fate” and “rate” determination scheme, where the influence of different parameters is attributed to fate determination step or rate determination step. In this discussion, microfluidic platforms have been used to understand reaction mechanism at single molecule level. Although the discussion raises more challenges for digital assay development, it brings the problem to the attention of the scientific community for the first time.
This dissertation also contributes towards developing POC test in limited resource settings. On one hand, it adds ease of access to the tests by incorporating massively producible, low cost plastic material and by integrating new features that allow instant result acquisition and result feedback. On the other hand, it explores new isothermal chemistry and new strategies to address important global health concerns such as cyctatin C quantification, HIV/HCV detection and treatment monitoring as well as HCV genotyping.
Resumo:
Since the discovery of the JAK2 V617F mutation in the majority of the myeloproliferative neoplasms (MPN) of polycythemia vera, essential thrombocythemia and primary myelofibrosis ten years ago, further MPN-specific mutational events, notably in JAK2 exon 12, MPL exon 10 and CALR exon 9 have been identified. These discoveries have been rapidly incorporated into evolving molecular diagnostic algorithms. While many of these mutations appear to have prognostic implications, establishing MPN diagnosis is of immediate clinical importance with selection, implementation and the continual evaluation of the appropriate laboratory methodology to achieve this diagnosis similarly vital. The advantages and limitations of these approaches in identifying and quantitating the common MPN-associated mutations is considered herein with particular regard to their clinical utility. The evolution of molecular diagnostic applications and platforms has occurred in parallel with the discovery of MPN-associated mutations and it therefore appears likely that emerging technologies such as next-generation sequencing and digital PCR will in the future, play an increasing role in the molecular diagnosis of MPN.
Resumo:
Campylobacter est l’agent pathogène zoonotique responsable de la majorité des gastro-entérites d’origine bactérienne chez l’homme. Les produits de volaille représentent la principale source d’infection; toutefois, l’exposition peut également découler de contacts directs avec les animaux ou avec l’eau. Une forte variation saisonnière est présente dans les cas rapportés, qui n’est toujours pas élucidée : les eaux environnementales, sources d’infection connues, sont soupçonnées. Cette étude transversale a été réalisée dans la région Sud-Est du Québec (Canada) où Campylobacter fut quantifié et génotypé à partir de différentes sources d’eau (eaux de captage, récréatives et usées) et de cas cliniques afin d’évaluer les risques potentiels posé par l’eau environnementale. Différents essais PCR en temps réel furent appliqués à l’eau environnementale et comparés: 2 ont été sélectionnés pour leur spécificité et sensibilité de quantification. Les courbes standards ont été calibrées en utilisant la PCR digitale pour déterminer précisément les concentrations. Les isolats environnementaux et cliniques furent comparés génétiquement en utilisant le CGF (« comparative genomic fingerprinting »). Les eaux usées étaient plus contaminées que les eaux de captage et récréatives (3.9Log, 1.7Log et 1.0Log cellules/L en moyenne, respectivement). Six pour cent des isolats d’eaux environnementales étaient génétiquement similaires (100 % homologie) aux isolats cliniques. Les cas cliniques de campylobactériose d’été montraient des isolats avec davantage de similarités génétiques avec les isolats retrouvés dans l’eau environnementale comparativement aux autres saisons (p<0.01). Les faibles concentrations et similarités génétiques entre les isolats d’eau et cliniques suggèrent un risque de transmission possible, mais faible.
Resumo:
Since the discovery of the JAK2 V617F mutation in the majority of the myeloproliferative neoplasms (MPN) of polycythemia vera, essential thrombocythemia and primary myelofibrosis ten years ago, further MPN-specific mutational events, notably in JAK2 exon 12, MPL exon 10 and CALR exon 9 have been identified. These discoveries have been rapidly incorporated into evolving molecular diagnostic algorithms. Whilst many of these mutations appear to have prognostic implications, establishing MPN diagnosis is of immediate clinical importance with selection, implementation and the continual evaluation of the appropriate laboratory methodology to achieve this diagnosis similarly vital. The advantages and limitations of these approaches in identifying and quantitating the common MPN-associated mutations are considered herein with particular regard to their clinical utility. The evolution of molecular diagnostic applications and platforms has occurred in parallel with the discovery of MPN-associated mutations, and it therefore appears likely that emerging technologies such as next-generation sequencing and digital PCR will in the future play an increasing role in the molecular diagnosis of MPN. Accepted for publication 30 April 2015 doi:10.1111/ejh.12578
Resumo:
Segundo O`Kane et al, em 2008, foi demonstrado que 88,9% dos erros laboratoriais são realizados na fase pré-analítica. No laboratório de análises clínicas, o sistema de controle da qualidade pode ser definido como toda a ação sistemática necessária para dar confiança e segurança em todos os exames e prevenir a ocorrência de erros. O tempo de armazenamento pode variar de dias a meses ou mesmo anos, influenciando na definição da temperatura de estocagem. O armazenamento de longo prazo pode resultar na criopreservação inadequada para determinados analitos e pode desnaturar as lipoproteínas. Objetivos: Este trabalho teve como objetivo avaliar a fase pré-analítica, controle da qualidade interno e também avaliar o efeito do congelamento (- 80C) quanto ao tempo de armazenamento do soro e plasma de sangue colhido com ácido etilenodiamino tetra-acético (EDTA). As dosagens foram realizadas no Laboratório de Lípides LabLip, e estocadas em - 80 C por três anos, as mesmas foram redosadas no Serviço de Patologia Clínica da Policlínica Piquet Carneiro da UERJ com metodologias iguais e realizada a comparabilidade dos resultados. Foram analisados o perfil lipídico (CT, HDLc e TG) e PCR-US de 103 amostras, 73 no soro e 30 no plasma em dois laboratórios altamente qualificados. Discussão: Após redosagem foram encontrados nas dosagens de HDLc e CT resultados diminuídos respectivamente (correlação coeficiente no soro 0,48 e 0,62) teste t pareado no soro (CT p 0,0012 e HDLc p 0,0001). Conclusões: Os dados obtidos nas avaliações dos resultados de diferentes laboratórios e tempo de estocagem revelaram que as amostras quando armazenadas por um longo período após redosagem no soro, apresentaram diferenças em certos analitos, tais como CT e HDLc, no qual obteve-se resultados significativamente diminuídos, diferentemente no plasma, que após três anos de estocagem a -80C foram redosados e aplicados no teste t pareado, os analitos CT e PCR-US mantiveram a estabilidade.