A certified plasmid reference material for the standardisation of BCR-ABL1 mRNA quantification by real-time quantitative PCR.


Autoria(s): White, H; Deprez, L; Corbisier, P; Hall, V; Lin, F; Mazoua, S; Trapmann, S; Aggerholm, A; Andrikovics, H; Akiki, S; Barbany, G; Boeckx, N; Bench, A; Catherwood, M; Cayuela, J-M; Chudleigh, S; Clench, T; Colomer, D; Daraio, F; Dulucq, S; Farrugia, J; Fletcher, L; Foroni, L; Ganderton, R; Gerrard, G; Gineikienė, E; Hayette, S; El Housni, H; Izzo, B; Jansson, M; Johnels, P; Jurcek, T; Kairisto, V; Kizilors, A; Kim, D-W; Lange, T; Lion, T; Polakova, K M; Martinelli, G; McCarron, S; Merle, P A; Milner, B; Mitterbauer-Hohendanner, G; Nagar, M; Nickless, G; Nomdedéu, J; Nymoen, D A; Oppliger Leibundgut, Elisabeth; Ozbek, U; Pajič, T; Pfeifer, H; Preudhomme, C; Raudsepp, K; Romeo, G; Sacha, T; Talmaci, R; Touloumenidou, T; Van der Velden, V H J; Waits, P; Wang, L; Wilkinson, E; Wilson, G; Wren, D; Zadro, R; Ziermann, J; Zoi, K; Müller, M C; Hochhaus, A; Schimmel, H; Cross, N C P; Emons, H
Data(s)

01/02/2015

Resumo

Serial quantification of BCR-ABL1 mRNA is an important therapeutic indicator in chronic myeloid leukaemia, but there is a substantial variation in results reported by different laboratories. To improve comparability, an internationally accepted plasmid certified reference material (CRM) was developed according to ISO Guide 34:2009. Fragments of BCR-ABL1 (e14a2 mRNA fusion), BCR and GUSB transcripts were amplified and cloned into pUC18 to yield plasmid pIRMM0099. Six different linearised plasmid solutions were produced with the following copy number concentrations, assigned by digital PCR, and expanded uncertainties: 1.08±0.13 × 10(6), 1.08±0.11 × 10(5), 1.03±0.10 × 10(4), 1.02±0.09 × 10(3), 1.04±0.10 × 10(2) and 10.0±1.5 copies/μl. The certification of the material for the number of specific DNA fragments per plasmid, copy number concentration of the plasmid solutions and the assessment of inter-unit heterogeneity and stability were performed according to ISO Guide 35:2006. Two suitability studies performed by 63 BCR-ABL1 testing laboratories demonstrated that this set of 6 plasmid CRMs can help to standardise a number of measured transcripts of e14a2 BCR-ABL1 and three control genes (ABL1, BCR and GUSB). The set of six plasmid CRMs is distributed worldwide by the Institute for Reference Materials and Measurements (Belgium) and its authorised distributors (https://ec.europa.eu/jrc/en/reference-materials/catalogue/; CRM code ERM-AD623a-f).

Formato

application/pdf

Identificador

http://boris.unibe.ch/78793/1/EO_leu2014217a.pdf

White, H; Deprez, L; Corbisier, P; Hall, V; Lin, F; Mazoua, S; Trapmann, S; Aggerholm, A; Andrikovics, H; Akiki, S; Barbany, G; Boeckx, N; Bench, A; Catherwood, M; Cayuela, J-M; Chudleigh, S; Clench, T; Colomer, D; Daraio, F; Dulucq, S; ... (2015). A certified plasmid reference material for the standardisation of BCR-ABL1 mRNA quantification by real-time quantitative PCR. Leukemia, 29(2), pp. 369-376. Nature Publishing Group 10.1038/leu.2014.217 <http://dx.doi.org/10.1038/leu.2014.217>

doi:10.7892/boris.78793

info:doi:10.1038/leu.2014.217

info:pmid:25036192

urn:issn:0887-6924

Idioma(s)

eng

Publicador

Nature Publishing Group

Relação

http://boris.unibe.ch/78793/

Direitos

info:eu-repo/semantics/openAccess

Fonte

White, H; Deprez, L; Corbisier, P; Hall, V; Lin, F; Mazoua, S; Trapmann, S; Aggerholm, A; Andrikovics, H; Akiki, S; Barbany, G; Boeckx, N; Bench, A; Catherwood, M; Cayuela, J-M; Chudleigh, S; Clench, T; Colomer, D; Daraio, F; Dulucq, S; ... (2015). A certified plasmid reference material for the standardisation of BCR-ABL1 mRNA quantification by real-time quantitative PCR. Leukemia, 29(2), pp. 369-376. Nature Publishing Group 10.1038/leu.2014.217 <http://dx.doi.org/10.1038/leu.2014.217>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed