900 resultados para Clark electrode
Resumo:
The number of P700 (the reaction centre of Photosystem I) converted to P700+, in winter rye, was determined by measuring the absorbance change at 820nm . It was found, with a single turnover flash, that thylakoids isolated from cold grown plants have a 50% greater number of P700 oxidized than thylakoids isolated from warm grown plants. Incubation of thylakoids in the dark at 35 C did not change the number of P700 oxidized. The conversion of P700 to P700+ with a single flash can be compared to a steady state rate of electron transport using a Clark electrode. The results for P700 oxidation using the absorbance change at 820 nm measure effects within the PSI complex whereas the results obtained from a Clark electrode measures steady state electron transport between the cytochrome blf complex and the PSI complex. In contrast to the results for P700 oxidation it was shown, using a Clark electrode, that both thylakoids from cold grown plants and thylakoids incubated at in the dark 35 C exhibited 50% higher rates of electron transport than thylakoids from warm grown plants. The correlation between the higher rate of steady state PSI electron transport observed in thylakoids isolated from cold grown winter rye and number of active PSI reaction centres localizes the site of the increase to the PSI reaction centre. In contrast the lack of correlation after incubation at 35 C indicates the increase in the rate of light saturated electron transport in thylakoids isolated from cold grown plants and thylakoids incubated in the dark at 35 C occur by different mechanisms.
Resumo:
L’objectif général de cette thèse est de développer une plateforme d’immobilisation d’enzymes efficace pour application en biopile. Grâce à la microencapsulation ainsi qu’au choix judicieux des matériaux polymériques pour la fabrication de la plateforme d’immobilisation, l’efficacité du transfert électronique entre l’enzyme encapsulée et l’électrode serait amélioré. Du même coup, les biopiles employant cette plateforme d’immobilisation d’enzymes pourrait voir leur puissance délivrée être grandement augmentée et atteindre les niveaux nécessaires à l’alimentation d’implants artificiels pouvant remplacer des organes telque le pancréas, les reins, le sphincter urinaire et le coeur. Dans un premier temps, le p-phénylènediamine a été employé comme substrat pour la caractérisation de la laccase encapsulée dans des microcapsules de poly(éthylèneimine). La diffusion de ce substrat à travers les microcapsules a été étudiée sous diverses conditions par l’entremise de son oxidation électrochimique et enzymatique afin d’en évaluer sa réversibilité et sa stabilité. La voltampérométrie cyclique, l’électrode à disque tournante (rotating disk electrode - RDE) et l’électrode à O2 ont été les techniques employées pour cette étude. Par la suite, la famille des poly(aminocarbazoles) et leurs dérivés a été identifée pour remplacer le poly(éthylèneimine) dans la conception de microcapsules. Ces polymères possèdent sur leurs unités de répétition (mono- ou diamino) des amines primaires qui seraient disponibles lors de la polymérisation interfaciale avec un agent réticulant tel qu’un chlorure de diacide. De plus, le 1,8-diaminocarbazole (unité de répétition) possède, une fois polymérisé, les propriétés électrochimiques recherchées pour un transfert d’électrons efficace entre l’enzyme et l’électrode. Il a toutefois été nécessaire de développer une route de synthèse afin d’obtenir le 1,8-diaminocarbazole puisque le protocole de synthèse disponible dans la littérature a été jugé non viable pour être utilisé à grande échelle. De plus, aucun protocole de synthèse pour obtenir du poly(1,8-diaminocarbazole) directement n’a été trouvé. Ainsi, deux isomères de structure (1,6 et 1,8-diaminocarbazole) ont pu être synthétisés en deux étapes. La première étape consistait en une substitution électrophile du 3,6-dibromocarbazole en positions 1,8 et/ou 1,6 par des groupements nitro. Par la suite, une réaction de déhalogénation réductive à été réalisée en utilisant le Et3N et 10% Pd/C comme catalyseur dans le méthanol sous atmosphère d’hydrogène. De plus, lors de la première étape de synthèse, le composé 3,6-dibromo-1-nitro-carbazole a été obtenu; un monomère clé pour la synthèse du copolymère conducteur employé. Finalement, la fabrication de microcapsules conductrices a été réalisée en incorporant le copolymère poly[(9H-octylcarbazol-3,6-diyl)-alt-co-(2-amino-9H-carbazol-3,6-diyl)] au PEI. Ce copolymère a pu être synthétisé en grande quantité pour en permettre son utilisation lors de la fabrication de microcapsules. Son comportement électrochimique s’apparentait à celui du poly(1,8-diaminocarbazole). Ces microcapsules, avec laccase encapsulée, sont suffisamment perméables au PPD pour permettre une activité enzymatique détectable par électrode à O2. Par la suite, la modification de la surface d’une électrode de platine a pu être réalisée en utilisant ces microcapsules pour l’obtention d’une bioélectrode. Ainsi, la validité de cette plateforme d’immobilisation d’enzymes développée, au cours de cette thèse, a été démontrée par le biais de l’augmentation de l’efficacité du transfert électronique entre l’enzyme encapsulée et l’électrode.
Resumo:
The present paper describes a novel, simple and reliable differential pulse voltammetric method for determining amitriptyline (AMT) in pharmaceutical formulations. It has been described for many authors that this antidepressant is electrochemically inactive at carbon electrodes. However, the procedure proposed herein consisted in electrochemically oxidizing AMT at an unmodified carbon nanotube paste electrode in the presence of 0.1 mol L(-1) sulfuric acid used as electrolyte. At such concentration, the acid facilitated the AMT electroxidation through one-electron transfer at 1.33 V vs. Ag/AgCl, as observed by the augmentation of peak current. Concerning optimized conditions (modulation time 5 ms, scan rate 90 mV s(-1), and pulse amplitude 120 mV) a linear calibration curve was constructed in the range of 0.0-30.0 μmol L(-1), with a correlation coefficient of 0.9991 and a limit of detection of 1.61 μmol L(-1). The procedure was successfully validated for intra- and inter-day precision and accuracy. Moreover, its feasibility was assessed through analysis of commercial pharmaceutical formulations and it has been compared to the UV-vis spectrophotometric method used as standard analytical technique recommended by the Brazilian Pharmacopoeia.
Resumo:
The possibility of using a graphite silicone-rubber composite electrode (GSR) in a differential pulse voltammetric(DPV) procedure for rutin (vitamin P) determination is described. Cyclic voltammograms of rutin presented a reversible pair of oxidation/reduction peaks respectively at 0.411 and 0.390 V (vs. SCE) at the GSR surface in Britton-Robinson(B-R) buffer solution pH 4.0. In DPV after optimization of conditions, an oxidation peak at 0.370 V (vs. SCE) was used to quantitative determination of rutin in B-R buffer solution pH 4.0. In this case a linear dynamic range of 5.0×10-8 to 50.0×10-8 mol L-1 was observed with a detection limit of 1.8×10-8 mol L-1 for the analyte. Recoveries from 94 to 113% were observed. The electrode surface was renewed by polishing after each determination, with a repeatability of 1.09 ± 0.06 µA (n = 10) peak current. Rutin was determined in a pharmaceutical formulation using the proposed electrode and the results agreed with those from an official method within 95% confidence level.
Resumo:
Thiol-functionalised silica films were deposited on various electrode surfaces (gold, platinum, glassy carbon) by spin-coating sol-gel mixtures in the presence of a surfactant template. Film formation occurred by evaporation induced self-assembly (EISA) involving the hydrolysis and (co)condensation of silane and organosilane precursors on the electrode surface. The characterization of such material was performed by IR spectroscopy, thermogravimetry (TG), elemental analysis (EA), atomic force microscopy (AFM), scanning electron microscopy (SEM) and cyclic voltammetry (CV).
Resumo:
A bare graphite-polyurethane composite was evaluated as an amperometric flow injection detector in the determination of paracetamol (APAP) in pharmaceutical formulations. A linear analytical curve was observed in the 5.00 x 10-5 to 5.00 x 10-3 mol L-1 range with a minimum detectable net concentration of 18.9 µmol L-1 and 180 determinations h-1, after optimization of parameters such as the detection potential, sample loop volume, and carrier solution flow rate. Interference of ascorbic acid was observed, however, it was possible overcome the interference, reaching results that agreed with HPLC within 95% confidence level. These results showed that the graphite-polyurethane composite can be used as an amperometric detector for flow analysis in the determination of APAP.
Resumo:
Nitrofurazone (NF) presents activity against Chagas' disease, yet it has a high toxicity. Its analog, hydroxymethylnitrofurazone (NFOH), is more potent against Trypanosoma cruzi and much less toxic than the parent drug, NF. The electrochemical reduction of NFOH in an aqueous medium using a glassy carbon electrode (GCE) is presented. By cyclic voltammetry in anacidic medium, one irreversible reduction peak related to hydroxylamine derivative formation was registered, being linearly pH dependent. However, from pH > 7, a reversible reduction peak at a more positive potential appears and corresponds to the formation of a nitro radical anion. The radical-anion kinetic stability was evaluated by Ip(a)/Ip(c) the current ratio of the R-NO(2)/R-NO(2)-redox couple. The nitro radical anion decays with a second-order rate constant (k(2)) of 6.07, 2.06, and 1.44(X 10(3)) L mol(-1) s(-1) corresponding to pH 8.29, 9.29, and 10.2, respectively, with a corresponding half-time life (t(1/2)) of 0.33, 0.97, and 1.4 s for each pH value. By polishing the GCE surface with diamond powder and comparing with the GCE surface polished with alumina, it is shown that the presence of alumina affects the lifetime of the nitro radical anion. (C) 2009 The Electrochemical Society. [DOI: 10.1149/1.3130082] All rights reserved.
Resumo:
In this work, the electron field emission behaviour of electrodes formed by carbon nanotubes (CNTs) grown onto monolithic vitreous carbon (VCarbon) substrates with microcavities is presented. Scanning electron microscopy was used to characterize the microstructure of the films. Tungsten probes, stainless steel sphere, and phosphor electrodes were employed in the electron field emission study. The CNT/VCarbon composite represents a route to inexpensive excellent large area electron emission cathodes with fields as low as 2.1 V mu m(-1). In preliminary lifetime tests for a period of about 24 h at an emission current of about 4 mA cm(-2), there is an onset degradation of the emission current of about 28%, which then stabilizes. Electron emission images of the composites show the cavity of the samples act as separate emission sites and predominantly control the emission process. The emission of CNTs/VCarbon was found to be stable for several hours. (c) 2008 American Institute of Physics.
Resumo:
The electrocatalytic reduction of hydrogen peroxide on a glassy carbon (GC) electrode modified with a ruthenium oxide hexacyanoferrate (RuOHCF) was investigated using rotating disc electrode (RDE) voltammetry aiming to improve the performance of the sensor for hydrogen peroxide detection. The influence of parameters such as rotation speed, film thickness and hydrogen peroxide concentration indicated that the rate of the cross-chemical reaction between Ru(II) centres immobilized into the film and hydrogen peroxide controls the overall process. The kinetic regime could be classified as LSk mechanism, according to the diagnostic table proposed by Albery and Hillman, and the kinetic constant of the mediated process was found to be 706 mol(-1) cm(3) s(-1). In the LSk case the reaction layer is located at a finite layer close to the modifier layer/solution interface
Resumo:
This work presents a study of the catalytic oxidation of ethanol on polycrystalline gold electrode in alkaline media. The investigation was carried out by means of chronoamperometry, cyclic voltammetry, and in situ FTIR spectroscopy. The main goal was to investigate the early stages of ethanol electrooxidation, namely at fairly low potentials (E = 600 mV vs. RHE) and for moderate reaction times (t < 300 s). Chronoamperometric experiments show a current increase accompanying the increasing in the ethanol concentration up to about 2 M and then a slight decrease at 3 M. Adsorbed CO has been observed as early as about 200 mV vs. RHE and indicates that the cleavage of the C-C bond might occur, probably to a small extent, at very low overpotentials during ethanol adsorption on gold surface. The amount of dissolved acetate ions produced during the chronoamperomentry was followed by the asymmetric stretching band at 1558 cm(-1) as a function of time, and found to increase linearly with time up to 300 s. This allowed estimating the reaction order of acetate formation with respect to ethanol concentration.
Resumo:
Void fraction sensors are important instruments not only for monitoring two-phase flow, but for furnishing an important parameter for obtaining flow map pattern and two-phase flow heat transfer coefficient as well. This work presents the experimental results obtained with the analysis of two axially spaced multiple-electrode impedance sensors tested in an upward air-water two-phase flow in a vertical tube for void fraction measurements. An electronic circuit was developed for signal generation and post-treatment of each sensor signal. By phase shifting the electrodes supplying the signal, it was possible to establish a rotating electric field sweeping across the test section. The fundamental principle of using a multiple-electrode configuration is based on reducing signal sensitivity to the non-uniform cross-section void fraction distribution problem. Static calibration curves were obtained for both sensors, and dynamic signal analyses for bubbly, slug, and turbulent churn flows were carried out. Flow parameters such as Taylor bubble velocity and length were obtained by using cross-correlation techniques. As an application of the void fraction tested, vertical flow pattern identification could be established by using the probability density function technique for void fractions ranging from 0% to nearly 70%.
Resumo:
Recent advances in the application of bioelectrical impedance analysis (BIA) have indicated that a more accurate approach to the estimation of total body water is to consider the impedance of the various body segments rather than simply that of the whole body. The segmental approach necessitates defining and locating the physical demarcation between both the trunk and leg and the trunk and arm. Despite the use of anatomical markers, these points of demarcation are difficult to locate with precision between subjects. There are also technical problems associated with the regional dispersion of the current distribution from one segment (cylinder) to another of different cross-sectional area. The concept of equipotentials in line with the proximal aspects of the upper land lower) limbs along the contralateral limbs was investigated and, in particular, the utility of this concept in the measurement of segmental bioimpedance. The variation of measured segmental impedance using electrode sites along these equipotentials was less than 2.0% for all of the commonly used impedance parameters. This variation is approximately equal to that expected from biological variation over the measurement time. It is recommended that the electrode sites, for the measurement of segmental bioelectrical impedance in humans, described herein are adopted in accordance with the proposals of the NM Technology Assessment Conference Statement.
Resumo:
We present a method for measuring single spins embedded in a solid by probing two-electron systems with a single-electron transistor (SET). Restrictions imposed by the Pauli principle on allowed two-electron states mean that the spin state of such systems has a profound impact on the orbital states (positions) of the electrons, a parameter which SET's are extremely well suited to measure. We focus on a particular system capable of being fabricated with current technology: a Te double donor in Si adjacent to a Si/SiO2, interface and lying directly beneath the SET island electrode, and we outline a measurement strategy capable of resolving single-electron and nuclear spins in this system. We discuss the limitations of the measurement imposed by spin scattering arising from fluctuations emanating from the SET and from lattice phonons. We conclude that measurement of single spins, a necessary requirement for several proposed quantum computer architectures, is feasible in Si using this strategy.
Resumo:
No Abstract