987 resultados para BWCTL Bandwidth Test Controller
Resumo:
Доклад, поместен в сборника на Националната конференция "Образованието в информационното общество", Пловдив, май, 2012 г.
Resumo:
Suspended loads on UAVs can provide significant benefits to several applications in agriculture, law enforcement and construction. The load impact on the underlying system dynamics should not be neglected as significant feedback forces may be induced on the vehicle during certain flight manoeuvres. Much research has focused on standard multi-rotor position and attitude control with and without a slung load. However, predictive control schemes, such as Nonlinear Model Predictive Control (NMPC), have not yet been fully explored. To this end, we present software and flight system architecture to test controller for safe and precise operation of multi-rotors with heavy slung load in three dimensions.
Resumo:
V2Ic control provides very fast dynamic performance to the Buck converter both under load steps and under voltage reference steps. However, the design of this control is complex since it is prone to subharmonic oscillations and several parameters affect the stability of the system. This paper derives and validates a very accurate modeling and stability analysis of a closed-loop V2Ic control using the Floquet theory. This allows the derivation of sensitivity analysis to design a robust converter. The proposed methodology is validated on a 5-MHz Buck converter. The work is also extended to V2 control using the same methodology, showing high accuracy and robustness. The paper also demonstrates, on the V2 control, that even a low bandwidth-linear controller can affect the stability of a ripple-based control.
Resumo:
A method of precise measurement of on-chip analog voltages in a mostly-digital manner, with minimal overhead, is presented. A pair of clock signals is routed to the node of an analog voltage. This analog voltage controls the delay between this pair of clock signals, which is then measured in an all-digital manner using the technique of sub-sampling. This sub-sampling technique, having measurement time and accuracy trade-off, is well suited for low bandwidth signals. This concept is validated by designing delay cells, using current starved inverters in UMC 130nm CMOS process. Sub-mV accuracy is demonstrated for a measurement time of few seconds.
Resumo:
Os sistemas distribuídos embarcados (Distributed Embedded Systems – DES) têm sido usados ao longo dos últimos anos em muitos domínios de aplicação, da robótica, ao controlo de processos industriais passando pela aviónica e pelas aplicações veiculares, esperando-se que esta tendência continue nos próximos anos. A confiança no funcionamento é uma propriedade importante nestes domínios de aplicação, visto que os serviços têm de ser executados em tempo útil e de forma previsível, caso contrário, podem ocorrer danos económicos ou a vida de seres humanos poderá ser posta em causa. Na fase de projecto destes sistemas é impossível prever todos os cenários de falhas devido ao não determinismo do ambiente envolvente, sendo necessária a inclusão de mecanismos de tolerância a falhas. Adicionalmente, algumas destas aplicações requerem muita largura de banda, que também poderá ser usada para a evolução dos sistemas, adicionandolhes novas funcionalidades. A flexibilidade de um sistema é uma propriedade importante, pois permite a sua adaptação às condições e requisitos envolventes, contribuindo também para a simplicidade de manutenção e reparação. Adicionalmente, nos sistemas embarcados, a flexibilidade também é importante por potenciar uma melhor utilização dos, muitas vezes escassos, recursos existentes. Uma forma evidente de aumentar a largura de banda e a tolerância a falhas dos sistemas embarcados distribuídos é a replicação dos barramentos do sistema. Algumas soluções existentes, quer comerciais quer académicas, propõem a replicação dos barramentos para aumento da largura de banda ou para aumento da tolerância a falhas. No entanto e quase invariavelmente, o propósito é apenas um, sendo raras as soluções que disponibilizam uma maior largura de banda e um aumento da tolerância a falhas. Um destes raros exemplos é o FlexRay, com a limitação de apenas ser permitido o uso de dois barramentos. Esta tese apresentada e discute uma proposta para usar a replicação de barramentos de uma forma flexível com o objectivo duplo de aumentar a largura de banda e a tolerância a falhas. A flexibilidade dos protocolos propostos também permite a gestão dinâmica da topologia da rede, sendo o número de barramentos apenas limitado pelo hardware/software. As propostas desta tese foram validadas recorrendo ao barramento de campo CAN – Controller Area Network, escolhido devido à sua grande implantação no mercado. Mais especificamente, as soluções propostas foram implementadas e validadas usando um paradigma que combina flexibilidade com comunicações event-triggered e time-triggered: o FTT – Flexible Time- Triggered. No entanto, uma generalização para CAN nativo é também apresentada e discutida. A inclusão de mecanismos de replicação do barramento impõe a alteração dos antigos protocolos de replicação e substituição do nó mestre, bem como a definição de novos protocolos para esta finalidade. Este trabalho tira partido da arquitectura centralizada e da replicação do nó mestre para suportar de forma eficiente e flexível a replicação de barramentos. Em caso de ocorrência de uma falta num barramento (ou barramentos) que poderia provocar uma falha no sistema, os protocolos e componentes propostos nesta tese fazem com que o sistema reaja, mudando para um modo de funcionamento degradado. As mensagens que estavam a ser transmitidas nos barramentos onde ocorreu a falta são reencaminhadas para os outros barramentos. A replicação do nó mestre baseia-se numa estratégia líder-seguidores (leaderfollowers), onde o líder (leader) controla todo o sistema enquanto os seguidores (followers) servem como nós de reserva. Se um erro ocorrer no nó líder, um dos nós seguidores passará a controlar o sistema de uma forma transparente e mantendo as mesmas funcionalidades. As propostas desta tese foram também generalizadas para CAN nativo, tendo sido para tal propostos dois componentes adicionais. É, desta forma possível ter as mesmas capacidades de tolerância a falhas ao nível dos barramentos juntamente com a gestão dinâmica da topologia de rede. Todas as propostas desta tese foram implementadas e avaliadas. Uma implementação inicial, apenas com um barramento foi avaliada recorrendo a uma aplicação real, uma equipa de futebol robótico onde o protocolo FTT-CAN foi usado no controlo de movimento e da odometria. A avaliação do sistema com múltiplos barramentos foi feita numa plataforma de teste em laboratório. Para tal foi desenvolvido um sistema de injecção de faltas que permite impor faltas nos barramentos e nos nós mestre, e um sistema de medida de atrasos destinado a medir o tempo de resposta após a ocorrência de uma falta.
Resumo:
In rural low-voltage networks, distribution lines are usually highly resistive. When many distributed generators are connected to such lines, power sharing among them is difficult when using conventional droop control, as the real and reactive power have strong coupling with each other. A high droop gain can alleviate this problem but may lead the system to instability. To overcome4 this, two droop control methods are proposed for accurate load sharing with frequency droop controller. The first method considers no communication among the distributed generators and regulates the output voltage and frequency, ensuring acceptable load sharing. The droop equations are modified with a transformation matrix based on the line R/X ration for this purpose. The second proposed method, with minimal low bandwidth communication, modifies the reference frequency of the distributed generators based on the active and reactive power flow in the lines connected to the points of common coupling. The performance of these two proposed controllers is compared with that of a controller, which includes an expensive high bandwidth communication system through time-domain simulation of a test system. The magnitude of errors in power sharing between these three droop control schemes are evaluated and tabulated.
Resumo:
In this paper, two different high bandwidth converter control strategies are discussed. One of the strategies is for voltage control and the other is for current control. The converter, in each of the cases, is equipped with an output passive filter. For the voltage controller, the converter is equipped with an LC filter, while an output has an LCL filter for current controller. The important aspect that has been discussed the paper is to avoid computation of unnecessary references using high-pass filters in the feedback loop. The stability of the overall system, including the high-pass filters, has been analyzed. The choice of filter parameters is crucial for achieving desirable system performance. In this paper, the bandwidth of achievable performance is presented through frequency (Bode) plot of the system gains. It has been illustrated that the proposed controllers are capable of tracking fundamental frequency components along with low-order harmonic components. Extensive simulation results are presented to validate the control concepts presented in the paper.
Resumo:
Unmanned Aerial Vehicles (UAVs) industry is a fast growing sector. Nowadays, the market offers numerous possibilities for off-the-shelf UAVs such as quadrotors or fixed-wings. Until UAVs demonstrate advance capabilities such as autonomous collision avoidance they will be segregated and restricted to flight in controlled environments. This work presents a visual fuzzy servoing system for obstacle avoidance using UAVs. To accomplish this task we used the visual information from the front camera. Images are processed off-board and the result send to the Fuzzy Logic controller which then send commands to modify the orientation of the aircraft. Results from flight test are presented with a commercial off-the-shelf platform.
Resumo:
The paper introduces the design of robust current and voltage control algorithms for a grid-connected three-phase inverter which is interfaced to the grid through a high-bandwidth three-phase LCL filter. The algorithms are based on the state feedback control which have been designed in a systematic approach and improved by using oversampling to deal with the issues arising due to the high-bandwidth filter. An adaptive loop delay compensation method has also been adopted to minimize the adverse effects of loop delay in digital controller and to increase the robustness of the control algorithm in the presence of parameter variations. Simulation results are presented to validate the effectiveness of the proposed algorithm.
Resumo:
This paper proposes a nonlinear excitation controller to improve transient stability, oscillation damping and voltage regulation of the power system. The energy function of the predicted system states is used to obtain the desired flux for the next time step, which in turn is used to obtain a supplementary control input using an inverse filtering method. The inverse filtering technique enables the system to provide an additional input for the excitation system, which forces the system to track the desired flux. Synchronous generator flux saturation model is used in this paper. A single machine infinite bus (SMIB) test system is used to demonstrate the efficacy of the proposed control method using time-domain simulations. The robustness of the controller is assessed under different operating conditions.
Resumo:
This report describes the development and simulation of a variable rate controller for a 6-degree of freedom nonlinear model. The variable rate simulation model represents an off the shelf autopilot. Flight experiment involves risks and can be expensive. Therefore a dynamic model to understand the performance characteristics of the UAS in mission simulation before actual flight test or to obtain parameters needed for the flight is important. The control and guidance is implemented in Simulink. The report tests the use of the model for air search and air sampling path planning. A GUI in which a set of mission scenarios, in which two experts (mission expert, i.e. air sampling or air search and an UAV expert) interact, is presented showing the benefits of the method.
Resumo:
A built-in-self-test (BIST) subsystem embedded in a 65-nm mobile broadcast video receiver is described. The subsystem is designed to perform analog and RF measurements at multiple internal nodes of the receiver. It uses a distributed network of CMOS sensors and a low bandwidth, 12-bit A/D converter to perform the measurements with a serial bus interface enabling a digital transfer of measured data to automatic test equipment (ATE). A perturbation/correlation based BIST method is described, which makes pass/fail determination on parts, resulting in significant test time and cost reduction.
Resumo:
In this paper, a method for the tuning the membership functions of a Mamdani type Fuzzy Logic Controller (FLC) using the Clonal Selection Algorithm(CSA) a model of the Artificial Immune System(AIS) paradigm is examined. FLC's are designed for two problems, firstly the linear cart centering problem and secondly the highly nonlinear inverted pendulum problem. The FLC tuned by AIS is compared with FLC tuned by GA. In order to check the robustness of the designed PLC's white noise was added to the system, further, the masses of the cart and the length and mass of the pendulum are changed. The PLC's were also tested in the presence of faulty rules. Finally, Kruskal Wallis test was performed to compare the performance of the GA and AIS. An insight into the algorithms are also given by studying the effect of the important parameters of GA and AIS.
Resumo:
A regenerative or circulating-power method is presented in this paper for heat run test on the legs of a three-level neutral point clamped (NPC) inverter. This test ensures that only losses are drawn from the dc supply, while rated power is circulated between the two legs, thus minimising wastage of energy. A proportional-resonant (PR) controller based current control scheme is proposed here for the circulating power test setup in NPC inverter. Simulation and experimental results are presented to validate the controller design at various operating conditions. Results of thermal test on the inverter legs are presented at two different operating conditions.