997 resultados para Atrial Function


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiofirequency ablation of the pulmonary veins has been used to treat patients with paroxysmal atrial fibrillation (AF), and atrial damage after ablation is an issue of concern. To evaluate left atrial function shortly and midterm after ablation, 33 consecutive patients with paroxysmal AF were studied at baseline, 24 hours, and >= 6 months after ablation. Patients in sinus rhythm with normal ventricular function were included in the study. Echocardiographic measurements of left atrial volumes (Simpson`s rule) and transmitral and tissue Doppler myocardial (A`) velocities at the septal and lateral mitral annulus were undertaken at each time. Left atrial emptying fraction (EF; maximal - minimal left atrial volume/maximal left atrial volume) was used to express left atrial function. After 8 +/- 2 months, 30 of 33 patients returned (23 men, age 53 +/- 13 years), and all except 2 were in sinus rhythm. Shortly after ablation, left atrial minimal volumes increased (from 30 +/- 15 to 35 +/- 15 ml; p = 0.02), with maximal volumes unchanged, resulting in decreased left atrial EF (from 47 +/- 8 to 40 +/- 7 ml; p <0.05). Tissue Doppler septal A` velocities also decreased (from 8.2 +/- 1.8 to 6.9 +/- 2.0 cm/s; p <0.05). However, after midterm follow-up, both left atrial EF and septal A` velocities had slightly increased compared with shortly after ablation, although left atrial volumes remained similar to baseline. Septal A` velocity changes paralleled left atrial EF both shortly (r = 0.46, p = 0.02) and at midterm after ablation (r = 0.47, p = 0.01). In conclusion, after radiofrequency ablation, patients with paroxysmal AF experienced an initial impairment in atrial function, with improvement at longer term follow-up. (C) 2009 Elsevier Inc. All rights reserved. (Am J Cardiol 2009;103: 395-398)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background:Chagas disease is a cause of dilated cardiomyopathy, and information about left atrial (LA) function in this disease still lacks.Objective:To assess the different LA functions (reservoir, conduit and pump functions) and their correlation with the echocardiographic parameters of left ventricular (LV) systolic and diastolic functions.Methods:10 control subjects (CG), and patients with Chagas disease as follows: 26 with the indeterminate form (GI); 30 with ECG alterations (GII); and 19 with LV dysfunction (GIII). All patients underwent M-mode and two-dimensional echocardiography, pulsed-wave Doppler and tissue Doppler imaging.Results:Reservoir function (Total Emptying Fraction: TEF): (p <0.0001), lower in GIII as compared to CG (p = 0.003), GI (p <0.001) and GII (p <0.001). Conduit function (Passive Emptying Fraction: PEF): (p = 0.004), lower in GIII (GIII and CG, p = 0.06; GI and GII, p = 0.06; and GII and GIII, p = 0.07). Pump function (Active Emptying Fraction: AEF): (p = 0.0001), lower in GIII as compared to CG (p = 0.05), GI (p<0.0001) and GII (p = 0.002). There was a negative correlation of E/e’average with the reservoir and pump functions (TEF and AEF), and a positive correlation of e’average with s’ wave (both septal and lateral walls) and the reservoir, conduit and pump LA functions.Conclusion:An impairment of LA functions in Chagas cardiomyopathy was observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract The assessment of left atrial (LA) function is used in various cardiovascular diseases. LA plays a complementary role in cardiac performance by modulating left ventricular (LV) function. Transthoracic two-dimensional (2D) phasic volumes and Doppler echocardiography can measure LA function non‑invasively. However, evaluation of LA deformation derived from 2D speckle tracking echocardiography (STE) is a new feasible and promising approach for assessment of LA mechanics. These parameters are able to detect subclinical LA dysfunction in different pathological condition. Normal ranges for LA deformation and cut-off values to diagnose LA dysfunction with different diseases have been reported, but data are still conflicting, probably because of some methodological and technical issues. This review highlights the importance of an unique standardized technique to assess the LA phasic functions by STE, and discusses recent studies on the most important clinical applications of this technique.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Envenoming by the pitviper Bothrops jararacussu produces cardiovascular alterations, including coagulopathy, systemic hemorrhage, hypotension, circulatory shock and renal failure. In this work, we examined the activity of this venom in rat isolated right atria. Incubation with venom (0.025, 0.05, 0.1 and 0.2mg/ml) caused concentration-dependent muscle contracture that was not reversed by washing. Muscle damage was seen histologically and confirmed by quantification of creatine kinase-MB (CK-MB) release. Heating and preincubation of venom with p-bromophenacyl bromide (a phospholipase A2 inhibitor) abolished the venom-induced contracture and muscle damage. In contrast, indomethacin, a non-selective inhibitor of cyclooxygenase, and verapamil, a voltage-gated Ca(2+) channel blocker, did not affect the responses to venom. Preincubation of venom with Bothrops or Bothrops/Crotalus antivenom or the addition of antivenom soon after venom attenuated the venom-induced changes in atrial function and tissue damage. These results indicate that B. jararacussu venom adversely affected rat atrial contractile activity and muscle organization through the action of venom PLA2; these venom-induced alterations were attenuated by antivenom.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

B-type natriuretic peptide (BNP) levels increase in systolic heart failure (HF). However, the value of BNP in hypertensive patients with suspected diastolic HF (symptoms suggestive of HF but normal ejection fraction) and its relation to myocardial function in these patients is unclear. We prospectively studied 72 ambulatory hypertensive subjects (40 women, mean age 58 +/- 8 years) with exertional dyspnea and ejection fraction greater than or equal to50%. Diastolic function was evaluated with transmitral and pulmonary venous Doppler, mitral annular velocities (pulsed-wave tissue Doppler), and flow propagation velocity (color M-mode). Systolic function was assessed with strain and strain rate derived from color tissue Doppler imaging. BNP was related to myocardial function and the presence or absence of global diastolic dysfunction. By conventional Doppler criteria, 34 patients had normal left ventricular diastolic function and 38 had isolated diastolic dysfunction. BNP values were higher in patients with diastolic dysfunction (46 +/- 48 vs 20 +/- 20 pg/ml, p = 0.004) and were related independently to blood pressure, systolic strain rate, left atrial function (p < 0.01 for all), and age (p = 0.015). Patients with diastolic dysfunction and pseudonormal filling had higher BNP levels compared with impaired relaxation (89 +/- 47 vs 35 +/- 42 pg/ml, p = 0.001). However, 79% of patients with diastolic dysfunction had BNP levels within the normal range. We conclude that in ambulatory hypertensive patients with symptoms suggestive of mild HF and normal ejection fraction, BNP is related to atrial and ventricular systolic parameters, blood pressure, and age. Although elevated in the presence of diastolic dysfunction, the BNP level mostly is in the normal range and, therefore, has limited diagnostic value in stable patients with suspected diastolic HF. (C) 2003 by Excerpta Medica, Inc.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: Atrial fibrillation is a very common heart arrhythmia, associated with a five-fold increase in the risk of embolic strokes. Treatment strategies encompass palliative drugs or surgical procedures all of which can restore sinus rhythm. Unfortunately, atria often fail to recover their mechanical function and patients therefore require lifelong anticoagulation therapy. A motorless volume displacing device (Atripump) based on artificial muscle technology, positioned on the external surface of atrium could avoid the need of oral anticoagulation and its haemorrhagic complications. An animal study was conducted in order to assess the haemodynamic effects that such a pump could provide. METHODS: Atripump is a dome-shape siliconecoated nitinol actuator sewn on the external surface of the atrium. It is driven by a pacemaker-like control unit. Five non-anticoagulated sheep were selected for this experiment. The right atrium was surgically exposed, the device sutured and connected. Haemodynamic parameters and intracardiac ultrasound (ICUS) data were recorded in each animal and under three conditions; baseline; atrial fibrillation (AF); atripump assisted AF (aaAF). RESULTS: In two animals, after 20 min of AF, small thrombi appeared in the right atrial appendix and were washed out once the pump was turned on. Assistance also enhanced atrial ejection fraction. 31% baseline; 5% during AF; 20% under aaAF. Right atrial systolic surfaces (cm2) were; 5.2 +/- 0.3 baseline; 6.2 +/- 0.1 AF; 5.4 +/- 0.3 aaAF. CONCLUSION: This compact and reliable pump seems to restore the atrial "kick" and prevents embolic events. It could avoid long-term anticoagulation therapy and open new hopes in the care of end-stage heart failure.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Diastolic heart failure (DHF) is characterized by dyspnea due to increased left ventricular (LV) filling pressures during stress. We sought the relationship of exercise-induced increases in B-type natriuretic peptide (BNP) to LV filling pressures and parameters of cardiovascular performance in suspected DHF. Methods Twenty-six treated hypertensive patients with suspected DHF (exertional dyspnea, LV ejection fraction >50%, and diastolic dysfunction) underwent maximal exercise echocardiography using the Bruce protocol. BNP, transmitral Doppler, and tissue Doppler for systolic (So) and early (Ea) and late (Aa) diastolic mitral annular velocities were obtained at rest and peak stress. LV filling pressures were estimated with E/Ea ratios. Results Resting BNP correlated with resting pulse pressure (r=0.45, P=0.02). Maximal exercise performance (4.6 +/- 2.5min) was limited by dyspnea. Blood pressure increased with exercise (from 143 +/- 19/88 +/- 8 to 191 +/- 22/90 +/- 10 mm Hg); 13 patients (50%) had a hypertensive response. Peak exercise BNP correlated with peak transmitral E velocity (r = 0.41, P <.05) and peak heart rate (r = -0.40, P <.05). BNP increased with exercise (from 48 57 to 74 97 pg/mL, P =.007), and the increment of BNP with exercise was associated with maximal workload and peak exercise So, Ea, and Aa (P <.01 for all). Filling pressures, approximated by lateral E/Ea ratio, increased with exercise (7.7 +/- 2.0 to 10.0 +/- 4.8, P <.01). BNP was higher in patients with possibly elevated filling pressures at peak exercise (E/Ea >10) compared to those with normal pressures (123 +/- 124 vs 45 +/- 71 pg/mL, P =.027). Conclusions Augmentation of BNP with exercise in hypertensive patients with suspected DHF is associated with better exercise capacity, LV systolic and diastolic function, and left atrial function. Peak exercise BNP levels may identify exercise-induced elevation of filling pressures in DHF.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Zebrafish and Xenopus have become popular model organisms for studying vertebrate development of many organ systems, including the heart. However, it is not clear whether the single ventricular hearts of these species possess any equivalent of the specialized ventricular conduction system found in higher vertebrates. Isolated hearts of adult zebrafish (Danio rerio) and African toads (Xenopus laevis) were stained with voltage-sensitive dye and optically mapped in spontaneous and paced rhythms followed by histological examination focusing on myocardial continuity between the atrium and the ventricle. Spread of the excitation wave through the atria was uniform with average activation times of 20 +/- 2 and 50 +/- 2 ms for zebrafish and Xenopus toads, respectively. After a delay of 47 +/- 8 and 414 +/- 16 ms, the ventricle became activated first in the apical region. Ectopic ventricular activation was propagated significantly more slowly (total ventricular activation times: 24 +/- 3 vs. 14 +/- 2 ms in zebrafish and 74 +/- 14 vs. 35 +/- 9 ms in Xenopus). Although we did not observe any histologically defined tracts of specialized conduction cells within the ventricle, there were trabecular bands with prominent polysialic acid-neural cell adhesion molecule staining forming direct myocardial continuity between the atrioventricular canal and the apex of the ventricle; i.e., the site of the epicardial breakthrough. We thus conclude that these hearts are able to achieve the apex-to-base ventricular activation pattern observed in higher vertebrates in the apparent absence of differentiated conduction fascicles, suggesting that the ventricular trabeculae serve as a functional equivalent of the His-Purkinje system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introducción: La gran mayoría de las medidas de normalidad utilizadas para la interpretación de resonancia cardiaca son extrapoladas de las medidas de ecocardiografía. Los limitados registros de medidas de normalidad se encuentran ajustados en poblaciones extranjeras, no hay registros en latinoamericanos. Objetivo: Determinar las dimensiones cardiacas utilizando resonancia magnética en una población de personas sin antecedente médicos con repercusión cardiaca para lograr una muestra de valores que permitan ajustar las medidas de normalidad utilizadas por nuestro servicio. Materiales y métodos: se analizaron 45 sujetos sanos con edad comprendida entre los 21 y 45 años, las adquisiciones se realizaron utilizando un equipo de RM de 1,5 teslas, el análisis de las imágenes se realizó mediante el programa Cardiac Volume Vx. Se evaluaron múltiples parámetros morfofuncionales a través de análisis estadístico por medio del sistema SPSS versión 23. Resultados: Mediciones obtenidas de ventrículo izquierdo principales fueron volumen diastólico en mujeres de 62 ml +/- 7.1 y en hombres de 65 ml +/- 11.2 y fracción de eyección de 60 % +/- 5 en mujeres y de 62 % +/- 9 en hombres. En ventrículo derecho el volumen diastólico final se encontró 81.8 ml +/- 14.6 en mujeres y 100 ml +/- 24.8 en hombres y fracción de eyección de 53 % +/- 17 en mujeres y de 45 % +/- 12 en hombres. Volumen de fin de diástole de 50 +/- 12.7 ml en mujeres y de 49 ml +/- 19 ml en hombres y fracción de eyección de aurícula izquierda de 55 % +/- 0.08 en mujeres y de 50 % +/- 0.07 en hombres. Volumen de fin de diástole de 44.1 ml +/- 18.5 en mujeres y de 49.2 ml +/- 22.9 en hombres y fracción de eyección de aurícula derecha de 50 % +/- 11 en mujeres y de 45 % +/- 8 en hombres. Se obtuvieron otras medidas lineales y volumétricas adicionales de cavidades cardiacas y de grandes vasos supracardiacos. Conclusiones: se describen los valores de referencia de los parámetros morfofuncionales de las cavidades cardiacas y de vasos supracardiacos. El sexo fue tenido en cuenta como covariable relacionada con la modificación de los parámetros evaluados. Se sugieren variaciones en las medidas de cavidades cardiacas para la población estudiada relacionada con aclimatación crónica a la altitud de la ciudad de Bogotá.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We investigated the mechanisms of the alterations in sensitivity to catecholamines in right atria from female rats exhibiting regular 4-day estrous cycles after three foot-shock sessions at estrus, metestrus, and diestrus or at diestrus, proestrus, and estrus. Right atria from stressed rats sacrificed at diestrus showed subsensitivity to noradrenaline and adrenaline. After in vitro sympathetic denervation (38 μM 6-hydroxydopamine) plus inhibition of neuronal reuptake (0.1 μM desipramine) subsensitivity to noradrenaline was abolished, but it was again evident when extraneuronal uptake was also inhibited (10 μM phenoxybenzamine and 30 μM corticosterone). The same pretreatment abolished the subsensitivity to adrenaline. After addition of 1 μM butoxamine, a β2-adrenoceptor antagonist, the tissues from stressed rats were subsensitive to adrenaline. Right atria from stressed rats sacrificed at estrus did not show any alteration in sensitivity to catecholamines. We conclude that after foot-shock stress, right atria from female rats sacrificed at diestrus showed subsensitivity of the chronotropic response to catecholamines as a result of a conformational alteration of β1-adrenoceptors, simultaneously with an increase in β2-adrenoceptor-mediated response. The mechanisms seem to be similar to those which underlie stress-induced alterations in catecholamine sensitivity in right atria from male rats. However, during estrus there are some protective factors that prevent the effects of stress on right atria.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Intervenção Cardiovascular.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Half of the patients with end-stage heart failure suffer from persistent atrial fibrillation (AF). Atrial kick (AK) accounts for 10-15% of the ejection fraction. A device restoring AK should significantly improve cardiac output (CO) and possibly delay ventricular assist device (VAD) implantation. This study has been designed to assess the mechanical effects of a motorless pump on the right chambers of the heart in an animal model. METHODS: Atripump is a dome-shaped biometal actuator electrically driven by a pacemaker-like control unit. In eight sheep, the device was sutured onto the right atrium (RA). AF was simulated with rapid atrial pacing. RA ejection fraction (EF) was assessed with intracardiac ultrasound (ICUS) in baseline, AF and assisted-AF status. In two animals, the pump was left in place for 4 weeks and then explanted. Histology examination was carried out. The mean values for single measurement per animal with +/-SD were analysed. RESULTS: The contraction rate of the device was 60 per min. RA EF was 41% in baseline, 7% in AF and 21% in assisted-AF conditions. CO was 7+/-0.5 l min(-1) in baseline, 6.2+/-0.5 l min(-1) in AF and 6.7+/-0.5 l min(-1) in assisted-AF status (p<0.01). Histology of the atrium in the chronic group showed chronic tissue inflammation and no sign of tissue necrosis. CONCLUSIONS: The artificial muscle restores the AK and improves CO. In patients with end-stage cardiac failure and permanent AF, if implanted on both sides, it would improve CO and possibly delay or even avoid complex surgical treatment such as VAD implantation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Le système nerveux autonome cardiaque est devenu une cible dans les thérapies ablatives de la fibrillation auriculaire. Nous avons étudié les voies de communication et la fonction des plexus ganglionnaires (PG) de l'oreillette gauche (PGOG) afin de clarifier la validité physiopathologique des méthodes de détection et des thérapies impliquant ces groupes de neuronnes. Méthodes: Vingt-deux chiens ont subi une double thoracotomie et ont été instrumentés avec des plaques auriculaires épidcardiques de multiélectrodes. Une stimulation électrique (2 mA, 15 Hz) des PGOG a été réalisée à l'état basal et successivement après: 1) une décentralisation vagale, 2) l'ablation par radiofréquence des plexus péri-aortiques et de la veine cave supérieure (Ao/VCS) et 3) l'ablation du PG de l'oreillette droite (PGOD). Ces procédures de dénervation ont été réalisées suivant une séquence antérograde (n = 17) ou rétrograde (n = 5). Résultats: Chez 17 des 22 animaux, la stimulation des PGOG a induit une bradycardie sinusale (149 ± 34 bpm vs 136 ± 28 bpm, p < 0.002) et des changements de repolarization (ΔREPOL) auriculaires isointégrales. Dans le groupe des ablations antérogrades, les réponses aux stimulations vagales ont été supprimées suite à la décentralisation vagale chez un seul animal, par l'ablation des plexus Ao/VCS dans 4 cas et par l'ablation du PGOG dans 5 autres animaux. Des changements ont persisté tout au long chez 2 chiens. La valeur de surface des ΔREPOL a diminué avec les dénervations séquentielles, passant de 365 ± 252 mm2 en basale à 53 ± 106 mm2 après l'ablation du PGOD (p < 0.03). Dans le groupe de dénervation rétrograde, les changements de repolarisation et chronotropiques ont été supprimés suite à l'ablation du PGOD chez deux chiens et suite à l'ablation Ao/VCS chez trois. La valeur de surface du ΔREPOL a aussi diminué après l'ablation du PGOD (269±144mm2 vs 124±158mm2, p<0.05). Conclusion: Les PGOD sont identifiables en préablation par la réponse bradycardique à la stimulation directe dans la plupart des cas. Le PGOD semble former la principale, mais non la seule, voie de communication avec le nœud sinusal. Ces résultats pourraient avoir des implications dans le traitement de la FA par méthodes ablatives.