995 resultados para Aqueous samples


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work describes the synthesis and characterization of 2-aminothiazole modified silica gel (SiAT) and the studies of adsorption and pre-concentration (in batch and using a flow-injection system coupled with optical emission spectrometer) of Cd(II), Cu(II) and Ni(II) in aqueous medium. The adsorption capacity for each metal ions in mmolg(-1) was: Cu(II) = 1.18, Ni(II) = 1.15 and Cd(II) = 1.10. The results obtained in the flow experiments showed about 100% of recovering of the metal ions adsorbed in a mini-column packed with 100 mg of SiAT, using 100 mu L of 2.0 mol L-1 HCl solution as eluent. The quantitative sorption-desorption of the metal ions made possible the application of a flow-injection system in the pre-concentration and quantification by ICP-OES of metal ions at trace level in natural water samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Raman analysis of dilute aqueous solutions is normally prevented by their low signal levels. A very general method to increase the concentration to detectable levels is to evaporate droplets of the sample to dryness, creating solid deposits which are then Raman probed. Here, superhydrophobic (SHP) wires with hydrophilic tips have been used as supports for drying droplets, which have the advantage that the residue is automatically deposited at the tip. The SHP wires were readily prepared in minutes using electroless galvanic deposition of Ag onto copper wires followed by modification with a polyfluorothiol (3,3,4,4,5,5,6,6,7,7,8,8,9,9,10,10,10-heptadecafluoro-1-decanethiol, HDFT). Cutting the coated wires with a scalpel revealed hydrophilic tips which could support droplets whose maximum size was determined by the wire diameter. Typically, 230 μm wires were used to support 0.6 μL droplets. Evaporation of dilute melamine droplets gave solid deposits which could be observed by scanning electron microscopy (SEM) and Raman spectroscopy. The limit of detection for melamine using a two stage evaporation procedure was 1 × 10-6 mol dm-3. The physical appearance of dried droplets of sucrose and glucose showed that the samples retained significant amounts of water, even under high vacuum. Nonetheless, the Raman detection limits of sucrose and glucose were 5 × 10-4 and 2.5 × 10-3 mol dm-3, respectively, which is similar to the sensitivity reported for surface-enhanced Raman spectroscopy (SERS) detection of glucose. It was also possible to quantify the two sugars in mixtures at concentrations which were similar to those found in human blood through multivariate analysis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work describes the efficiency of photoelectrocatalysis based on Ti/TiO2 nanotubes in the degradation of the azo dyes Disperse Red 1, Disperse Red 13 and Disperse Orange 1 and to remove their toxic properties, as an alternative method for the treatment of effluents and water. For this purpose, the discoloration rate, total organic carbon (TOC) removal, and genotoxic, cytotoxic and mutagenic responses were determined, using the comet, micronucleus and cytotoxicity assays in HepG2 cells and the Salmonella mutagenicity assay. In a previous study it was found that the surfactant Emulsogen could contribute to the low mineralization of the dyes (60% after 4h of treatment), which, in turn, seems to account for the mutagenicity of the products generated. Thus this surfactant was not added to the chloride medium in order to avoid this interference. The photoelectrocatalytic method presented rapid discoloration and the TOC reduction was ≥87% after 240min of treatment, showing that photoelectrocatalysis is able to mineralize the dyes tested. The method was also efficient in removing the mutagenic activity and cytotoxic effects of these three dyes. Thus it was concluded that photoelectrocatalysis was a promising method for the treatment of aqueous samples. © 2013 Elsevier Ltd.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The present study describes the incorporation of a complexing agent, dithiooxamide, into microcrystalline cellulose for use in the pre-concentration of Cu(II) and Cd(II) ions from aqueous samples. The FTIR spectrum of the adsorbent exhibited an absorption band in the region of 800 cm-1, which confirmed the binding of the silylating agent to the matrix. Elemental analysis indicated the amount of 0.150 mmol g-1 of the complexing agent. The adsorption data were fit to the modified Langmuir equation, and the maximum amount of metal species extracted from the solution, Ns, was determined to be 0.058 and 0.072 mmol g-1 for Cu(II) and Cd(II), respectively. The covering fraction φ, which was 0.39 and 0.48 for Cu(II) and Cd(II), respectively, was used to estimate a 1:2 (metal:ligand) ratio in the formed complex, and a binding model was proposed based on this information. The adsorbent was applied in the pre-concentration of natural water samples and exhibited an enrichment factor of approximately 50-fold for the species studied, which enabled its use in the analysis of trace metals in aqueous samples. The system was validated by the analysis of certified standard (1643e), and the adsorbent was stable for more than 20 cycles, thus enabling its safe reutilization. © 2012 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A novel, simple, rapid and eco-friendly method based on dispersive liquid-liquid microextraction using a bromosolvent was developed to determine six estrogenic mycotoxins (zearalenone, zearalanone, alpha-zearalanol, beta-zearalanol, alpha-zearalenol and beta-zearalenol) in water samples by liquid chromatography-electrospray ionization tandem mass spectrometry in the negative mode (LC-ESI-MS/MS). The optimal conditions for this method include the use of 100 mu L bromocyclohexane as an extraction solvent (using a non-dispersion solvent), 10 mL of aqueous sample (adjusted to pH 4), a vortex extraction time of 2 min, centrifugation for 10 min at 3500 rpm and no ionic strength adjustment. The calibration function was linear and was verified by applying the Mandel fitting test with a 95% confidence level. No matrix effect was observed. According to the relative standard deviations (RSDs), the precision was better than 13% for the repeatability and intermediate precision. The average recoveries of the spiked compounds ranged from 81 to 118%. The method limits of detection (LOD) and quantification (LOQ) considering a 125-fold pre-concentration step were 4-20 and 8-40 ng L-1, respectively. Next, the method was applied to the analysis of the environmental aqueous samples, demonstrating the presence of beta-zearalanol and zearalanone in the river water samples. (C) 2015 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A methodology to analyze organochlorine pesticides (OCPs) in water samples has been accomplished by using headspace stir bar sorptive extraction (HS-SBSE). The bars were in house coated with a thick film of PDMS in order to properly work in the headspace mode. Sampling was done by a novel HS-SBSE system whereas the analysis was performed by capillary GC coupled mass spectrometric detection (HS-SBSE-GC-MS). The extraction optimization, using different experimental parameters has been established by a standard equilibrium time of 120 min at 85 degrees C. A mixture of ACN/toluene as back extraction solvent promoted a good performance to remove the OCPs sorbed in the bar. Reproducibility between 2.1 and 14.8% and linearity between 0.96 and 1.0 were obtained for pesticides spiked in a linear range between 5 and 17 ng/g in water samples during the bar evaluation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A protein microarray hybridisation system has been implemented by employing patterned hydrophobic thin films on hydrophilic substrates as a means of confinement for aqueous samples. This approach has the ability to handle, and keep separate, small sample volumes of just a few microlitres. In addition, the system is more straightforward to use than the existing multi-well gasket solution. The paper describes the fabrication method and the system is demonstrated for a model protein microarray assay. © 2011 American Institute of Physics.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Composition of the coronary artery plaque is known to have critical role in heart attack. While calcified plaque can easily be diagnosed by conventional CT, it fails to distinguish between fibrous and lipid rich plaques. In the present paper, the authors discuss the experimental techniques and obtain a numerical algorithm by which the electron density (rho(e)) and the effective atomic number (Z(eff)) can be obtained from the dual energy computed tomography (DECT) data. The idea is to use this inversion method to characterize and distinguish between the lipid and fibrous coronary artery plaques. Methods: For the purpose of calibration of the CT machine, the authors prepare aqueous samples whose calculated values of (rho(e), Z(eff)) lie in the range of (2.65 x 10(23) <= rho(e) <= 3.64 x 10(23)/cm(3)) and (6.80 <= Z(eff) <= 8.90). The authors fill the phantom with these known samples and experimentally determine HU(V-1) and HU(V-2), with V-1,V-2 = 100 and 140 kVp, for the same pixels and thus determine the coefficients of inversion that allow us to determine (rho(e), Z(eff)) from the DECT data. The HU(100) and HU(140) for the coronary artery plaque are obtained by filling the channel of the coronary artery with a viscous solution of methyl cellulose in water, containing 2% contrast. These (rho(e), Z(eff)) values of the coronary artery plaque are used for their characterization on the basis of theoretical models of atomic compositions of the plaque materials. These results are compared with histopathological report. Results: The authors find that the calibration gives Pc with an accuracy of 3.5% while Z(eff) is found within 1% of the actual value, the confidence being 95%. The HU(100) and HU(140) are found to be considerably different for the same plaque at the same position and there is a linear trend between these two HU values. It is noted that pure lipid type plaques are practically nonexistent, and microcalcification, as observed in histopathology, has to be taken into account to explain the nature of the observed (rho(e), Z(eff)) data. This also enables us to judge the composition of the plaque in terms of basic model which considers the plaque to be composed of fibres, lipids, and microcalcification. Conclusions: This simple and reliable method has the potential as an effective modality to investigate the composition of noncalcified coronary artery plaques and thus help in their characterization. In this inversion method, (rho(e), Z(eff)) of the scanned sample can be found by eliminating the effects of the CT machine and also by ensuring that the determination of the two unknowns (rho(e), Z(eff)) does not interfere with each other and the nature of the plaque can be identified in terms of a three component model. (C) 2015 American Association of Physicists in Medicine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A sol-gel coating method for the preparation of extractive phase on bars used in sorptive microextraction is described. The extraction phase of poly(dimethylsiloxane) is partially crosslinked with the sol-gel network, and the most part is physically incorporated in the network. Three aging steps at different temperatures are applied to complete the crosslinking process. Thirty-micrometer-thick coating layer is obtained by one coating process. The improved coating shows good thermal stability up to 300degreesC. Spiked aqueous samples containing n-alkanes, polycyclic aromatic hydrocarbons and organophosphorus pesticides were analyzed by using the sorptive bars and GC. The results demonstrate that it is suitable for both aploar and polar analytes. The detection limit for chrysene is 7.44 ng/L, 0.74 ng/L for C-19 and 0.9 ng/L for phorate. The extraction equilibration can be reached in less than 15 min by supersonic extraction with the bars of 30 mum coating layer. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Based on previous studies, boron can be separated from aqueous samples with Amberlite IRA-743 resin. Experiments on the elute temperature, elute volume and the dynamic resin exchange capacity have been performed in this study. Results show that the dynamic exchange capacity of the resin is 4.2mg B/g and at room temperature, boron fixed on the resin within this capacity level can be extracted quantitatively by using 5ml 2%HNO3. A new procedure has been developed for the measurement of boron isotope ratios in water samples using a Neptune MC-ICP-MS, after resolving the memory effect, which is a key problem, and investigating the impacts of mass bias and Si matrix effect. Using this method, it usually takes 20 min to perform one measurement on 0.1ppm boron solution with a precision of 0.23‰ (SD). If the relative deviation between a sample and the standard is large, the washout time needs to be doubled to achieve a higher precision. δ11B values of water samples from Yangbajing geothermal field vary from -10.53 to -9.13‰. Owing to the large difference B concentration and the small B isotope difference between deep geothermal water and surface water, B isotope ratios of the shallow geothermal fluids are dominated by the deep end member rather than the shallower one in the mixing process. As a consequence, δ11B-B relation is indicative basically of a dilution process. Vapor-liquid separation and calcite scaling also greatly influence B isotope fractionation. δ11B values of water samples from Dagejia geothermal field are from -15.98‰ to -11.67‰. Boron in Changma River near the field has two sources, freshwater lakes (Dajiamang Lake and Canke Lake) and geothermal waters. Finally, a preliminary discussion is included on boron geochemical characteristics of the salt lakes in Shuanghu area and other geothermal fields, to provide information for future studies on boron isotope geochemistry of geothermal systems and salt lakes in Tibet.