999 resultados para Alta frequ
Resumo:
Objetivo O objetivo do presente estudo foi avaliar a associação do sono, depressão e ansiedade em pacientes com migrânea. Métodos Cinquenta pacientes do sexo feminino, provenientes de um centro terciário de tratamento de cefaleias, com o diagnóstico de migrânea segundo os critérios da International Headache Society, foram incluídas neste estudo. As pacientes foram avaliadas com os seguintes instrumentos: Migraine Disability Assessment test (MIDAS), Headache Impact Test (HIT), Hospital Anxiety (HADS-A) and Depression Scale (HAD-D), Índice de Qualidade do Sono de Pittsburgh (IQSP) e Escala de Sonolência de Epworth (ESE). Resultados As pacientes apresentaram alta prevalência de sintomas de ansiedade (60%) e de depressão (42%), má qualidade do sono (80%) e sonolência diurna (36%). Foi demonstrada correlação positiva entre a gravidade dos sintomas de ansiedade e HIT (p = 0,018; ρ = 0,334), ESE (p = 0,002; ρ = 0,426) e IQSP (p = 0,002; ρ = 0,426). Correlação positiva também foi demonstrada entre a gravidade dos sintomas depressivos e HIT (p < 0,001; ρ = 0,532), ESE (p = 0,035; ρ = 0,299) e IQSP (p = 0,016, ρ = 0,34). Não houve associação entre a qualidade do sono, a sonolência diurna e a gravidade da migrânea. A pontuação na HAD-D foi o principal preditor de impacto grave da migrânea. Conclusão Apesar da alta frequência de distúrbios do sono, o principal fator relacionado ao impacto da migrânea foi a gravidade dos sintomas depressivos.
Resumo:
OBJETIVO Analisar os motivos de atraso na alta hospitalar de pacientes internados em enfermarias de clínica médica. MÉTODOS Foram analisados 395 prontuários de pacientes consecutivos das enfermarias de clínica médica de dois hospitais públicos de ensino: Hospital das Clínicas da Universidade Federal de Minas Gerais e Hospital Odilon Behrens. Foi utilizado o Appropriateness Evaluation Protocol para definir o momento a partir do qual as anotações do prontuário permitiam concluir que a permanência no hospital não mais era adequada. O intervalo entre esse momento e a data da alta hospitalar efetivada definiu o total de dias de atraso na alta hospitalar. Foi utilizado, sistematicamente, instrumento para categorizar os motivos de atraso da alta hospitalar, tendo sido realizada análise de frequências. RESULTADOS O atraso na alta hospitalar ocorreu em 60,0% das 207 internações do Hospital das Clínicas e em 58,0% das 188 internações do Hospital Odilon Behrens. O atraso por paciente foi em média de 4,5 dias no primeiro e 4,1 dias no segundo, o que corresponde à taxa de ocupação de 23,0% e 28,0% em cada hospital, respectivamente. Os principais motivos de atraso nos dois hospitais foram, respectivamente: espera para realização de exames complementares (30,6% e 34,7%) ou para liberação dos laudos dos exames (22,4% e 11,9%) e os relacionados à responsabilidade médica (36,2% e 26,1%), compreendendo a demora na discussão do caso clínico e na tomada de decisão clínica e dificuldades nas interconsultas, respectivamente (20,4% e 9,1%). CONCLUSÕES Foi constatado percentual elevado de atraso na alta hospitalar nos dois hospitais. O atraso foi devido principalmente a fatores relacionados a processos, que podem ser melhorados por intervenções da equipe assistencial e dos gestores. O impacto na média de permanência hospitalar e na taxa de ocupação foi expressivo e preocupante, num cenário de relativa escassez de leitos e longas esperas por internação.
Resumo:
This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.
Resumo:
Synthetic dyes are much used in processed foods. HPLC was applied to different types of snacks, such as colored cereals, chocolate confetti, chewing gums and candies for the determination of those additives. In the case of artificially colored breakfast cereals, 71% of the samples exceeded the allowed limits. Regarding the portions recommended for consumption by the makers of two of the samples, the amounts exceeded those allowed by the Brazilian legislation. In the case of chocolate confetti and candies none of the samples showed higher amounts than those allowed. However 37% of the chewing gum samples presented larger contents than the authorized ones, and one sample contained five times more synthetic dyes than allowed.
Resumo:
The high cost of sensitivity commercial calorimeters may represent an obstacle for many calorimetric research groups. This work describes the construction and calibration of a batch differential heat conduction calorimeter with sample cells volumes of about 400 μL. The calorimeter was built using two small high sensibility square Peltier thermoelectric sensors and the total cost was estimated to be about US$ 500. The calorimeter was used to study the excess enthalpy of solution of binary mixtures of liquids, as a function of composition, for the following binary systems of solvents: water + 1,4-dioxane or + dimethylsulfoxide at 298,2 ± 0,5 K.
Resumo:
A method to quantify lycopene and β-carotene in freeze dried tomato pulp by high performance liquid chromatography (HLPC) was validated according to the criteria of selectivity, sensitivity, precision and accuracy, and uncertainty estimation of measurement was determined with data obtained in the validation. The validated method presented is selective in terms of analysis, and it had a good precision and accuracy. Detection limit for lycopene and β-carotene was 4.2 and 0.23 mg 100 g-1, respectively. The estimation of expanded uncertainty (K = 2) for lycopene was 104 ± 21 mg 100 g-1 and for β-carotene was 6.4 ± 1.5 mg 100 g-1.
Resumo:
Emerging organic pollutants (EOP) include many environmental contaminants based on commercial products such as pharmaceuticals, personal care products, detergents, gasoline, polymers, etc. EOP may be candidates for future regulation as they offer potential risk to environmental and human health due to their continual entrance into the environment and to the fact that even the most modern wastewater treatment plants are not able to totally transform / remove these compounds. High performance liquid chromatography is recommended to separate emerging organic pollutants with characteristics of high polarity and low volatility, especially pharmaceuticals, from environmental matrices.
Resumo:
This paper presents the behavior of three bored piles conducted in diabasic soil submitted to uplift forces. The piles were built at the site for Experimental Studies in Soil Mechanics and Foundations of UNICAMP, located in the city of Campinas, Brazil. Field tests have already been conducted at the site (SPT, CPT, DMT and PMT), as well as laboratory tests by using sample soils taken from a well up to 17 m deep. The water table is not checked until a depth of 17 m. In order to check the behavior of the piles when submitted to uplift forces, slow static load tests were carried out as the recommendations of NBR 12131. The carrying capacity of these piles was also provided by means of theoretical methods, appropriate for uplift forces, and through semi-empirical methods appropriate for compression forces, considering only the portion of lateral resistance. The values estimated by using the considered methods were compared to those obtained by means of load tests. One of the tested piles was extracted from the soil to be the subject of a study on its geometry.
Resumo:
Remote sensing data are each time more available and can be used to monitor the vegetal development of main agricultural crops, such as the Arabic coffee in Brazil, since that the relationship between spectral and agronomical data be well known. Therefore, this work had the main objective to assess the use of Quickbird satellite images to estimate biophysical parameters of coffee crop. Test area was composed by 25 coffee fields located between the cities of Ribeirão Corrente, Franca and Cristais Paulista (SP), Brazil, and the biophysical parameters used were row and between plants spacing, plant height, LAI, canopy diameter, percentage of vegetation cover, roughness and biomass. Spectral data were the reflectance of four bands of QUICKBIRD and values of four vegetations indexes (NDVI, GVI, SAVI and RVI) based on the same satellite. All these data were analyzed using linear and nonlinear regression methods to generate estimation models of biophysical parameters. The use of regression models based on nonlinear equations was more appropriate to estimate parameters such as the LAI and the percentage of biomass, important to indicate the productivity of coffee crop.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
O objetivo deste estudo foi avaliar o efeito da contagem de células somáticas (CCS) do leite na atividade de plasmina e plasminogênio durante o período de armazenamento do leite longa vida integral. Os leites crus foram categorizados em grupos de CCS de baixa (342.000-487.000 células mL-1) e alta contagem (603.000-808.000 células mL-1). Dois lotes de leite longa vida em cada categoria de CCS foram analisados para determinação de plasmina e plasminogênio após 10, 30, 60, 90 e 120 dias de armazenamento em temperatura ambiente. Para a fabricação do leite longa vida, o leite cru foi submetido à pasteurização rápida seguida da esterilização industrial do leite por injeção de vapor pelo método direto e embalagem asséptica do produto. A CCS não apresentou efeitos sobre as características físico-químicas do leite cru, e nem sobre a atividade de plasmina e plasminogênio nos leites cru e longa vida, armazenados por 120 dias. Entretanto, independentemente da CCS, a atividade de plasmina e plasminogênio aumentou no leite longa vida ao longo do armazenamento, indicando a possibilidade de aumento da proteólise no produto durante sua vida de prateleira.