787 resultados para Accommodating intraocular lens
Resumo:
Purpose: To examine a single-optic accommodating intraocular lens (IOL) visual performance by correlating IOL implanted eyes’ defocus curve with the intraocular aberrometric profile and the impact on the quality of life (QOL). Methods: Prospective consecutive case series study including a total of 25 eyes of 14 patients with ages ranging between 52 and 79 years old. All cases underwent cataract surgery with implantation of the single-optic accommodating IOL Crystalens HD (Bausch & Lomb). Distance and near visual acuity outcomes, intraocular aberrations, the defocus curve and QOL (NEI VFQ-25) were evaluated 3 months after surgery. Results: A significant improvement in distance visual acuity was found postoperatively (p = 0.02). Mean postoperative LogMAR uncorrected near visual acuity was 0.44 ± 0.23 (20/30). 60% of eyes had a postoperative addition between 0 and 1.5 diopters (D). The defocus curve showed an area of maximum visual acuity for the levels of defocus corresponding to distance and intermediate vision (−1 to +0.5 D). Postoperative intermediate visual acuity correlated significantly some QOL indices (r ≥ 0.51, p ≤ 0.03; difficulty in going down steps or seeing how people react to things that patient says) as well as with J0 component of manifest cylinder. Postoperative distance-corrected near visual acuity correlated significantly with age (r = 0.65, p < 0.01). Conclusions: This accommodating IOL seems to be able to restore the distance visual function as well as to provide an improvement in intermediate and near vision with a significant impact on patient's QOL, although limited by age and astigmatism. Future studies with larger sample sizes should confirm all these trends.
Resumo:
The crystalline lens allows the eye to focus on near and far objects. During the aging process, it loses its ability to focus and often becomes cloudy during cataract formation. At this point, traditional medical therapy replaces the lens with an artificial replacement lens. Although replacement lenses for the crystalline lens have been implanted since 1949 for cataract surgery, none of the FDA-approved lenses mimic the anatomy of the natural lens. Hence, they are not able to focus in a manner similar to the youthful lens. Instead, they function in a manner similar to the aged lens and only provide vision at a single distance or at a very limited range of focal distances. Patients with the newest implants are often obliged to use reading glasses when using near vision, or suffer from optical aberrations, halos, or glare. Therefore, there is a need to provide youthful vision after lens surgery in terms of focusing ability, accurate optical power, and sharp focus without distortion or optical aberrations.
This thesis presents an approach to restoring youthful vision after lens replacement. An intraocular lens (IOL) that can provide accurate visual acuity along with focusing ability is proposed. This IOL relies on the natural anatomy and physiology of the eye, and therefore is actuated in a manner identical to the natural lens. In addition, the lens has the capability for adjustment during or after implantation to provide high-acuity vision throughout life.
The natural anatomy and physiology of the eye is described, along with lens replacement surgery. A lens design is proposed to address the unmet need of lens-replacement patients. Specific care in the design is made for small surgical incisions, high visual acuity, adjustable acuity over years, and the ability to focus similar to the natural lens. Methods to test the IOL using human donor tissue are developed based upon prior experiments on the ex vivo natural lens. These tools are used to demonstrate efficacy of the newly developed accommodating intraocular lens.
To further demonstrate implant feasibility, materials and processes for building the lens are evaluated for biocompatibility, endurance, repeatable manufacture, and stability. The lens biomechanics are determined after developing an artificial anatomy testing setup inspired by the natural anatomy of the human focusing mechanism. Finally, based upon a mechanical and optical knowledge of the lens, several improved lens concepts are proposed and demonstrated for efficacy.
Resumo:
Presbyopia is an age-related physiological condition that causes a gradual loss in the ability to focus on near objects, secondary to changes in zonular fibers, ciliary muscle and crystalline lens. Different surgical approaches are being pursued to surgically compensate presbyopia, such as corneal techniques or implantation of multifocal intraocular lenses (IOLs); however, their inability to restore accommodation has led to the development of single-optic positional accommodative IOLs. The axial shift, with the contraction of the ciliary muscle, of these IOLs increases the refractive power of the eye, improving the level of uncorrected near vision. Single-optic positional accommodative IOLs present few disturbances and larger ocular aberrations that improve near vision. However, reduced amplitudes of accommodation are obtained, little IOL shifts are measured and overall visual outcomes are limited.
Resumo:
Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). Materials and Methods: Clinical data from 25 eyes of 14 patients (age range, 52–77 years) and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb) were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (PIOLadj) based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (nkadj) for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELPadj). PIOLadj was compared to the real IOL power implanted (PIOLReal, calculated with the SRK-T formula) and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. Results: No statistically significant differences were found between PIOLReal and PIOLadj when ELPadj was used (P = 0.10), with a range of agreement between calculations of 1.23 D. In contrast, PIOLReal was significantly higher when compared to PIOLadj without using ELPadj and also compared to the values estimated by the other formulas. Conclusions: Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.
Resumo:
Purpose: To develop a questionnaire that subjectively assesses near visual function in patients with 'accommodating' intraocular lenses (IOLs). Methods: A literature search of existing vision-related quality-of-life instruments identified all questions relating to near visual tasks. Questions were combined if repeated in multiple instruments. Further relevant questions were added and item interpretation confirmed through multidisciplinary consultation and focus groups. A preliminary 19-item questionnaire was presented to 22 subjects at their 4-week visit post first eye phacoemulsification with 'accommodative' IOL implantation, and again 6 and 12 weeks post-operatively. Rasch Analysis, Frequency of Endorsement, and tests of normality (skew and kurtosis) were used to reduce the instrument. Cronbach's alpha and test-retest reliability (intraclass correlation coefficient, ICC) were determined for the final questionnaire. Construct validity was obtained by Pearson's product moment correlation (PPMC) of questionnaire scores to reading acuity (RA) and to Critical Print Size (CPS) reading speed. Criterion validity was obtained by receiver operating characteristic (ROC) curve analysis and dimensionality of the questionnaire was assessed by factor analysis. Results: Rasch Analysis eliminated nine items due to poor fit statistics. The final items have good separation (2.55), internal consistency (Cronbach's α = 0.97) and test-retest reliability (ICC = 0.66). PPMC of questionnaire scores with RA was 0.33, and with CPS reading speed was 0.08. Area under the ROC curve was 0.88 and Factor Analysis revealed one principal factor. Conclusion: The pilot data indicates the questionnaire to be internally consistent, reliable and a valid instrument that could be useful for assessing near visual function in patients with 'accommodating' IOLS. The questionnaire will now be expanded to include other types of presbyopic correction. © 2007 British Contact Lens Association.
Resumo:
PURPOSE:To investigate the mechanism of action of the Tetraflex (Lenstec Kellen KH-3500) accommodative intraocular lens (IOL). METHODS:Thirteen eyes of eight patients implanted with the Tetraflex accommodating IOL for at least 2 years underwent assessment of their objective amplitude-of-accommodation by autorefraction, anterior chamber depth and pupil size with optical coherence tomography, and IOL flexure with aberrometry, each viewing a target at 0.0 to 4.00 diopters of accommodative demand. RESULTS:Pupil size decreased by 0.62+/-0.41 mm on increasing accommodative demand, but the Tetraflex IOL was relatively fixed in position within the eye. The ocular aberrations of the eye changed with increased accommodative demand, but not in a consistent manner among individuals. Those aberrations that appeared to be most affected were defocus, vertical primary and secondary astigmatism, vertical coma, horizontal and vertical primary and secondary trefoil, and spherical aberration. CONCLUSIONS:Some of the reported near vision benefits of the Tetraflex accommodating IOL appear to be due to changes in the optical aberrations because of the flexure of the IOL on accommodative effort rather than forward movement within the capsular bag.
Resumo:
Purpose - To assess clinical outcomes and subjective experience after bilateral implantation of a diffractive trifocal intraocular lens (IOL). Setting - Midland Eye Institute, Solihull, United Kingdom. Design - Cohort study. Methods - Patients had bilateral implantation of Finevision trifocal IOLs. Uncorrected distance visual acuity, corrected distance visual acuity (CDVA), and manifest refraction were measured 2 months postoperatively. Defocus curves were assessed under photopic and mesopic conditions over a range of +1.50 to -4.00 diopters (D) in 0.50 D steps. Contrast sensitivity function was assessed under photopic conditions. Halometry was used to measure the angular size of monocular and binocular photopic scotomas arising from a glare source. Patient satisfaction with uncorrected near vision was assessed using the Near Activity Visual Questionnaire (NAVQ). Results - The mean monocular CDVA was 0.08 logMAR ± 0.08 (SD) and the mean binocular CDVA, 0.06 ± 0.08 logMAR. Defocus curve testing showed an extended range of clear vision from +1.00 to -2.50 D defocus, with a significant difference in acuity between photopic conditions and mesopic conditions at -1.50 D defocus only. Photopic contrast sensitivity was significantly better binocularly than monocularly at all spatial frequencies. Halometry showed a glare scotoma of a mean size similar to that in previous studies of multifocal and accommodating IOLs; there were no subjective complaints of dysphotopsia. The mean NAVQ Rasch score for satisfaction with near vision was 15.9 ± 10.7 logits. Conclusions - The trifocal IOL implanted binocularly produced good distance visual acuity and near and intermediate visual function. Patients were very satisfied with their uncorrected near vision.
Resumo:
Aim: To determine whether eyes implanted with the Lenstec KH-3500 "accommodative" intraocular lenses (IOLs) have improved subjective and objective focusing performance compared to a standard monofocal IOLs. Methods: 28 participants were implanted monocularly with a KH-3500 " accommodative" IOL and 20 controls with a Softec1 IOL. Outcome measures of refraction, visual acuity, subjective amplitude of accommodation, objective accommodative stimulus response curve, aberrometry, and Scheimpflug imaging were taken at ∼3 weeks and repeated after 6 months. Results: Best corrected acuity with the KH-3500 was 0.06 (SD 0.13) logMAR at distance and 0.58 (0.20) logMAR at near. Accommodation was 0.39 (0.53) D measured objectively and 3.1 (1.6) D subjectively. Higher order aberrations were 0.87 (0.85) μm and lower order were 0.24 (0.39) μm. Posterior subcapsular light scatter was 0.95% (1.37%) greater than IOL clarity. In comparison, all control group measures were similar except objective (0.17 (0.13) D; p = 0.032) and subjective (2.0 (0.9) D; p = 0.009) amplitude of accommodation. Six months following surgery, posterior subcapsular scatter had increased (p<0.01) in the KH-3500 implanted subjects and near word acuity had decreased (p<0.05). Conclusions: The objective accommodating effects of the KH-3500 IOL appear to be limited, although the subjective and objective accommodative range is significantly increased compared to control subjects implanted with conventional IOLs. However, this "accommodative" ability of the lens appears to have decreased by 6 months post-surgery.
Resumo:
PURPOSE. To compare the objective accommodative amplitude and dynamics of eyes implanted with the one-compartment-unit (1CU; HumanOptics AG, Erlangen, Germany) accommodative intraocular lenses (IOLs) with that measured subjectively. METHODS. Twenty eyes with a 1CU accommodative IOL implanted were refracted and distance and near acuity measured with a logMAR (logarithm of the minimum angle of resolution) chart. The objective accommodative stimulus-response curve for static targets between 0.17 and 4.00 D accommodative demand was measured with the SRW-5000 (Shin-Nippon Commerce Inc., Tokyo, Japan) and PowerRefractor (PlusOptiX, Nürnberg, Germany) autorefractors. Continuous objective recording of dynamic accommodation was measured with the SRW-5000, with the subject viewing a target moving from 0 to 2.50 D at 0.3 Hz through a Badal lens system. Wavefront aberrometry measures (Zywave; Bausch & Lomb, Rochester, NY) were made through undilated pupils. Subjective amplitude of accommodation was measured with the RAF (Royal Air Force accommodation and vergence measurement) rule. RESULTS. Four months after implantation best-corrected acuity was -0.01 ± 0.16 logMAR at distance and 0.60 ± 0.09 logMAR at near. Objectively, the static amplitude of accommodation was 0.72 ± 0.38 D. The average dynamic amplitude of accommodation was 0.71 ± 0.47 D, with a lag behind the target of 0.50 ± 0.48 seconds. Aberrometry showed a decrease in power of the lens-eye combination from the center to the periphery in all subjects (on average, -0.38 ± 0.28 D/mm). Subjective amplitude of accommodation was 2.24 ± 0.42 D. Two years after 1CU implantation, refractive error and distance visual acuity remained relatively stable, but near visual acuity, and the subjective and objective amplitudes of accommodation decreased. CONCLUSIONS. The objective accommodating effects of the 1CU lens appear to be limited, although patients are able to track a moving target. Subjective and objective accommodation was reduced at the 2-year follow-up. The greater subjective amplitude of accommodation is likely to result from the eye's depth of focus of and the aspheric nature of the IOL. Copyright © Association for Research in Vision and Ophthalmology.
Resumo:
Purpose: To determine whether the ‘through-focus’ aberrations of a multifocal and accommodative intraocular lens (IOL) implanted patient can be used to provide rapid and reliable measures of their subjective range of clear vision. Methods: Eyes that had been implanted with a concentric (n = 8), segmented (n = 10) or accommodating (n = 6) intraocular lenses (mean age 62.9 ± 8.9 years; range 46-79 years) for over a year underwent simultaneous monocular subjective (electronic logMAR test chart at 4m with letters randomised between presentations) and objective (Aston open-field aberrometer) defocus curve testing for levels of defocus between +1.50 to -5.00DS in -0.50DS steps, in a randomised order. Pupil size and ocular aberration (a combination of the patient’s and the defocus inducing lens aberrations) at each level of blur was measured by the aberrometer. Visual acuity was measured subjectively at each level of defocus to determine the traditional defocus curve. Objective acuity was predicted using image quality metrics. Results: The range of clear focus differed between the three IOL types (F=15.506, P=0.001) as well as between subjective and objective defocus curves (F=6.685, p=0.049). There was no statistically significant difference between subjective and objective defocus curves in the segmented or concentric ring MIOL group (P>0.05). However a difference was found between the two measures and the accommodating IOL group (P<0.001). Mean Delta logMAR (predicted minus measured logMAR) across all target vergences was -0.06 ± 0.19 logMAR. Predicted logMAR defocus curves for the multifocal IOLs did not show a near vision addition peak, unlike the subjective measurement of visual acuity. However, there was a strong positive correlation between measured and predicted logMAR for all three IOLs (Pearson’s correlation: P<0.001). Conclusions: Current subjective procedures are lengthy and do not enable important additional measures such as defocus curves under differently luminance or contrast levels to be assessed, which may limit our understanding of MIOL performance in real-world conditions. In general objective aberrometry measures correlated well with the subjective assessment indicating the relative robustness of this technique in evaluating post-operative success with segmented and concentric ring MIOL.
Resumo:
PURPOSE: To determine whether implantation of an aspherical intraocular lens (IOL) results in reduced ocular aberrations and improved contrast sensitivity after cataract surgery without critical reduction of depth of focus. DESIGN: Double-blinded, randomized, prospective study. METHODS: In an intraindividual study of 25 patients with bilateral cataract, an aspherical IOL (Akreos Advanced Optic [AO]; Bausch & Lomb, Inc., Rochester, New York, USA) was implanted in one eye and a spherical IOL (Akreos Fit; Bausch & Lomb, Inc) in the fellow eye. Higher-order aberrations with a 5- and 6-mm pupil were measured with a dynamic retinoscopy aberrometer at 1 and 3 months after surgery. Uncorrected and best-corrected visual acuity and contrast sensitivity under mesopic and photopic conditions also were measured. Distance-corrected near and intermediate visual acuity were studied as a measurement of depth of focus. RESULTS: There was no statistically significant difference between eyes in uncorrected and best-corrected visual acuity at I and 3 months after surgery. There was a statistically significant between-group difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. The Akreos AO group obtained statistically significant lower values of higher-order aberrations and spherical aberration with 5- and 6-mm pupils compared with the Akreos Fit group (P < .05). There was no significant difference in distance-corrected near and intermediate visual acuity between both groups. CONCLUSIONS: Aspherical aberration-free Akreos AO IOL induced significantly less higher-order aberrations and spherical aberration than the Akreos Fit. Contrast sensitivity was better under mesopic conditions with the Akreos AO with similar results of depth of focus. (Am J Ophthalmol 2010;149:383-389. (C) 2010 by Elsevier Inc. All rights reserved.)
Resumo:
Multifocal intraocular lenses (MF IOLs) have concentric optical zones with different dioptric power, enabling patients to have good visual acuity at multiple focal points. However, several optical limitations have been attributed to this particular design. The purpose of this study is to access the effect of MF IOLs design on the accuracy of retinal optical coherence tomography (OCT). Cross-sectional study conducted at the Refractive Surgery Department of Central Lisbon Hospital Center. Twenty-three eyes of 15 patients with a diffractive MF IOL and 27 eyes of 15 patients with an aspheric monofocal IOL were included in this study. All patients underwent OCT macular scans using Heidelberg Spectralis®. Macular thickness and volume values and image quality (Q factor) were compared between the two groups. There were no statistically significant differences between both groups regarding macular thickness or volume measurements. Retinal OCT image quality was significantly lower in the MF IOL group (p < 0.01). MF IOLs are associated with a significant decrease in OCT image quality. However, this fact does not seem to compromise the accuracy of spectral domain OCT retinal measurements.
Resumo:
Background/Aims: To evaluate multifocal intraocular lens (MIOL) implantation in children. Methods: This is a retrospective study evaluating refractive, visual and safety results of MIOL in pediatric cataract surgery. Average follow-up was 25.73 ± 10.5 months. Surgery included 12 o'clock clear corneal incision, anterior capsulorhexis, lens material aspiration and MIOL implantation (SN6AD3; Alcon). Results: We included 34 cataract eyes of 26 pediatric patients aged 2-15 years, of which 14 (54%) were unilateral. Best near visual acuity (BNVA) and best distance visual acuity (BDVA) improved significantly in 100% of eyes (p = 0.0001). BDVA was above 0.8 in 31.25% (5/16) of bilateral cases. Significant stereopsis improvement was observed postoperatively in bilateral cases only (p = 0.01). Conclusion: MIOL implantation is a safe alternative to monofocal pseudophakia for pediatric cataract with a very low complication rate. Significant BNVA, BDVA and stereopsis improvement can be achieved, particularly in bilateral cases. Message: This study shows significant BDVA, BNVA and stereopsis improvement, especially in bilateral cases, after MIOL implantation for pediatric cataracts. © 2013 S. Karger AG, Basel.
Resumo:
Purpose: IOL centration and stability after cataract surgery is of high interest for cataract surgeons and IOL-producing companies. We present a new imaging software to evaluate the centration of the rhexis and the centration of the IOL after cataract surgery.Methods: We developed, in collaboration with the Biomedical Imaging Group (BIG), EPFL, Lausanne, a new working tool in order to assess precisely outcomes after IOL-implantation, such as ideal capsulorhexis and IOL-centration. The software is a plug-in of ImageJ, a general-purpose image processing and image-analysis package. The specifications of this software are: evaluation of the rhexis-centration and evaluation the position of the IOL in the posterior chamber. The end points are to analyze the quality of the centration of a rhexis after cataract surgery, the deformation of the rhexis with capsular bag retraction and the centration of the IOL after implantation.Results: This software delivers tools to interactively measure the distances between limbus, IOL and capsulorhexis and its changes over time. The user is invited to adjust nodes of three radial curves for the limbus, rhexis and the optic of the IOL. The radial distances of the curves are computed to evaluate the IOL implantation. The user is also able to define patterns for ideal capsulorhexis and optimal IOL-centration. We are going to present examples of calculations after cataract surgery.Conclusions: Evaluation of the centration of the rhexis and of the IOL after cataract surgery is an important end point for optimal IOL implantation after cataract surgery. Especially multifocal or accommodative lenses need a precise position in the bag with a good stability over time. This software is able to evaluate these parameters just after the surgery but also its changes over time. The results of these evaluations can lead to an optimizing of surgical procedures and materials.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)