990 resultados para pressure tube


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To facilitate the investigation of free mycophenolic acid concentrations we developed a high-performance liquid chromatography tandem mass spectrometry method using indomethacin as an internal standard. Free drug was isolated from plasma samples (500 mul) using ultrafiltration, The analytes were extracted from the ultrafiltrate (200 mul) using C-18 solid-phase extraction. Detection was by selected reactant monitoring of mycophenolic acid (m/z 318.9-->190.9) and the internal standard (m/z 356.0-->297.1) with an atmospheric pressure chemical ionisation interface. The total chromatographic analysis time was 12 min. The method was found to be linear over the range investigated, 2.5-200 mug/l (r>0.990, n=6). The relative recovery of the method for the control samples studied (7.5, 40.0 and 150 mug/l) ranged from 95 to 104%. The imprecision of the method, expressed in terms of intra- and inter-day coefficients of variation, was

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In humans, intra-abdominal pressure (IAP) is elevated during many everyday activities. This experiment aimed to investigate the extent to which increased IAP-without concurrent activity of the abdominal or back extensor muscles-produces an extensor torque. With subjects positioned in side lying on a swivel table with its axis at L3, moments about this vertebral level were measured when IAP was transiently increased by electrical stimulation of the diaphragm via the phrenic nerve. There was no electromyographic activity in abdominal and back extensor muscles. When IAP was increased artificially to similar to 15% of the maximum IAP amplitude that could be generated voluntarily with the trunk positioned in flexion, a trunk extensor moment (similar to6 Nm) was recorded. The size of the effect was proportional to the increase in pressure. The extensor moment was consistent with that predicted from a model based on measurements of abdominal cross-sectional area and IAP moment arm. When IAP was momentarily increased while the trunk was flexed passively at a constant velocity, the external torque required to maintain the velocity was increased. These results provide the first in vivo data of the amplitude of extensor moment that is produced by increased IAP. Although the net effect of this extensor torque in functional tasks would be dependent on the muscles used to increase the IAP and their associated flexion torque, the data do provide evidence that IAP contributes, at least in part, to spinal stability. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positive end expiratory pressure (PEEP) is important for neonatal ventilation but is not considered in guidelines for resuscitation. Our aim was to investigate the effects of PEEP on cardiorespiratory parameters during resuscitation of very premature lambs delivered by hysterotomy at similar to125 d gestation (term similar to147 d). Before delivery, they were intubated and lung fluid was drained. Immediately after delivery, they were ventilated with a Drager Babylog plus ventilator in volume guarantee mode with a tidal volume of 5 mL/kg. Lambs were randomized to receive 0, 4, 8, or 12 cm H2O of PEEP. They were ventilated for a 15-min resuscitation period followed by 2 h of stabilization at the same PEEP. Tidal volume, peak inspiratory pressure, PEEP, arterial pressure, oxygen saturation, and blood gases were measured regularly, and respiratory system compliance and alveolar/ arterial oxygen differences were calculated. Lambs that received 12 cm H2O of PEEP died from pneumothoraces; all others survived without pneumothoraces. Oxygenation was significantly improved by 8 and 12 cm H2O of PEEP compared with 0 and 4 cm H2O of PEEP. Lambs with 0 PEEP did not oxygenate adequately. The compliance of the respiratory system was significantly higher at 4 and 8 cm H2O of PEEP than at 0 PEEP. There were no significant differences in partial pressure of carbon dioxide in arterial blood between groups. Arterial pressure was highest with 8 cm H2O of PEEP, and there was no cardiorespiratory compromise at any level of PEEP. Applying PEEP during resuscitation of very premature infants might be advantageous and merits further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive, selective, and reproducible in-tube solid-phase microextraction and liquid chromatographic (in-tube SPME/LC-UV) method for simultaneous determination of mirrazapine, citalopram, paroxetine, duloxetine, fluoxetine, and sertraline in human plasma was developed, validated and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. The quantification limits of the in-tube SPME/LC method varied between 20 and 50 ng/mL, with a coefficient of variation lower than 10%. The response of the in-tube SPME/LC method for most of the drugs was linear over a dynamic range from 50 to 500 ng/mL, with correlation coefficients higher than 0.9985. The in-tube SPME/LC can be successfully used to analyze plasma samples from ageing patients undergoing therapy with nontricyclic antidepressants. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive, selective, and reproducible in-tube polypyrrole-coated capillary (PPY) solid-phase microextraction and liquid chromatographic method for fluoxetine and norfluoxetine enantiomers analysis in plasma samples has been developed, validated, and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. Separation of the analytes was achieved with a Chiralcel OD-R column and a mobile phase consisting of potassium hexafluorophosphate 7.5 mM and sodium phosphate 0.25 M solution, pH 3.0, and acetonitrile (75:25, v/v) in the isocratic mode, at a flow rate of 1.0 mL/min. Detection was carried out by fluorescence absorbance at Ex/Em 230/290 nm. The multifunctional porous surface structure of the PPY-coated film provided high precision and accuracy for enantiomers. Compared with other commercial capillaries, PPY-coated capillary showed better extraction efficiency for all the analytes. The quantification limits of the proposed method were 10 ng/mL for R- and S-fluoxetine, and 15 ng/mL for R- and S-norfluoxetine, with a coefficient of variation lower than 13%. The response of the method for enantiomers is linear over a dynamic range, from the limit of quantification to 700ng/mL, with correlation coefficients higher than 0.9940. The in-tube SPME/LC method can therefore be successfully used to analyze plasma samples from ageing patients undergoing therapy with fluoxetine. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive and automated method is described for determination of rifampicin in plasma samples for therapeutic drug monitoring by in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC). Important factors in the optimization of in-tube SPME are discussed, such as coating type, sample pH, sample draw/eject volume, number of draw/eject cycles, and draw/eject flow rate. Analyte pre-concentrated in the polyethylene glycol phase was directly transferred to the liquid chromatographic column by percolation of the mobile phase, without carryover. The method was linear over the 0.1-100 mu g/mL range, with a linear coefficient value (r(2)) of 0.998. The inter-assay precision presented coefficient of variation <= 1.7%. The effectiveness and practicability of the proposed method are proven by analysis of plasma samples from ageing patients undergoing therapy with rifampicin. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Obesity and obstructive sleep apnea (OSA) are both associated with the prevalence of major cardiovascular illnesses and certain common factors they are considered responsible for, such as stress oxidative increase, sympathetic tonus and resistance to insulin. Objective: The aim of the present study was to compare the effect of continuous positive airway pressure (CPAP) on oxidative stress and adiponectin levels in obese patients with and without OSA. Methods: Twenty-nine obese patients were categorized into 3 groups: group 1: 10 individuals without OSA (apnea-hypopnea index, AHI <= 5) who did not have OSA diagnosed at polysomnography; group 2: 10 patients with moderate to severe OSA (AHI >= 20) who did not use CPAP; group 3: 9 patients with moderate to severe OSA (AHI >= 20) who used CPAP. Results: Group 3 showed significant differences before and after the use of CPAP, in the variables of diminished production of superoxide, and increased nitrite and nitrate synthesis and adiponectin levels. Positive correlations were seen between the AHI and the superoxide production, between the nitrite and nitrate levels and the adiponectin levels, between superoxide production and the HOMA-IR, and between AHI and the HOMA-IR. Negative correlations were found between AHI and the nitrite and nitrate levels, between the superoxide production and that of nitric oxide, between the superoxide production and the adiponectin levels, between AHI and the adiponectin levels, and between the nitrite and nitrate levels and the HOMA-IR. Conclusions: This study demonstrates that the use of CPAP can reverse the increased superoxide production, the diminished serum nitrite, nitrate and plasma adiponectin levels, and the metabolic changes existing in obese patients with OSA. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. It is not known if the adjustment of antihypertensive therapy based on home blood pressure monitoring (HBPM) can improve blood pressure (BP) control among haemodialysis patients. Methods. This is an open randomized clinical trial. Hypertensive patients on haemodialysis were randomized to have the antihypertensive therapy adjusted based on predialysis BP measurements or HBPM. Before and after 6 months of follow-up, patients were submitted to ambulatory blood pressure monitoring (ABPM) for 24 h, HBPM during 1 week and echocardiogram. Results. A total of 34 and 31 patients completed the study in the HBPM and predialysis BP groups, respectively. At the end of study, the systolic (SBP) and diastolic (DBP) blood pressure during the interdialytic period measured by ABPM were significantly lower in the HBPM group in relation to the predialysis BP group (mean 24-h BP: 135 +/- 12 mmHg/76 +/- 7 mmHg versus 147 +/- 15 mmHg/79 +/- 8 mmHg; P < 0.05). In the HBPM analysis, the HBPM group showed a significant reduction only in SBP compared to the predialysis BP group (weekly mean: 144 +/- 21 mmHg versus 154 +/- 22 mmHg; P < 0.05). There were no differences between the HBPM and predialysis BP groups in relation to the left ventricular mass index at the end of the study (108 +/- 35 g/m(2) versus 110 +/- 33 g/m(2); P > 0.05). Conclusions. Decision making based on HBPM among haemodialysis patients has led to a better BP control during the interdialytic period in comparison with predialysis BP measurements. HBPM may be a useful adjuvant instrument for blood pressure control among haemodialysis patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Guidelines recommend neonatal resuscitation without controlling tidal volume or positive end-expiratory pressure (PEEP). However, these may improve gas exchange, lung volume and outcome. Aim: To investigate resuscitation of very premature lambs with a Laerdal bag without PEEP versus volume guarantee ventilation with PEEP. Methods: Anaesthetized lambs (n = 20) delivered at 125 d gestation were randomized to three groups receiving 15 min resuscitation: (1) Laerdal bag and no PEEP; (2) ventilation with a tidal volume of 5 ml/kg and 8 cm H2O PEEP; (3) ventilation with 10 ml/kg and 8 cm H2O PEEP. They were then all ventilated for 2 h with tidal volumes of 5 or 10 ml/kg, and 8 cm H2O PEEP. Ventilation parameters and blood gases were recorded. Results: Different tidal volumes affected PaCO2 within minutes, with 10 ml/kg causing severe hypocarbia. PEEP had little effect on PaCO2. Oxygenation improved significantly with PEEP of 8 cm H2O, irrespective of tidal volume. Conclusion: Very premature lambs can be resuscitated effectively using volume-guarantee ventilation and PEEP. Tidal volumes affected PaCO2 within minutes but had little effect on oxygenation. PEEP halved the oxygen requirement compared with no PEEP. Resuscitating premature babies with controlled tidal volumes and PEEP might improve their outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. We describe a series of 10 children with intracranial hypertension complicating fulminant hepatic failure submitted to intracranial pressure (ICP) monitoring for intensive care an transplantation management. Patients and methods. Information from pediatrics patients acute liver failure admitted to our hospital was collected in a standard protocol form. We analyzed data from 10 patients, medium age 5.2 years old. In this period we studied aspects as ICP transducer used, number of days with ICP monitoring and complications of ICP monitoring. Results. Hepatitis A was diagnosed in five patients and hepatitis B in two cases. The initial ICP were 2 to 24 mmHg in transducer Seven patients died, four due to intracranial hypertension, included the patient operated for subdural hematoma, and three with transplantation failure. Only, a case of hematoma was verified. Conclusions. The application of ICP monitoring allows intensive care for aggressive ICP management. It can be used in children without adaptations. [REV NEUROL 2009: 48: 134-6]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Retention of airway secretions is a common and serious problem in ventilated patients. Treating or avoiding secretion retention with mucus thinning, patient-positioning, airway suctioning, or chest or airway vibration or percussion may provide short-term benefit. METHODS: In a series of laboratory experiments with a test-lung system we examined the role of ventilator settings and lung-impedance on secretion retention and expulsion. Known quantities of a synthetic dye-stained mucus simulant with clinically relevant properties were injected into a transparent tube the diameter of an adult trachea and exposed to various mechanical-ventilation conditions. Mucus-simulant movement was measured with a photodensitometric technique and examined with image-analysis software. We tested 2 mucus-simulant viscosities and various peak flows, inspiratory/ expiratory flow ratios, intrinsic positive end-expiratory pressures, ventilation waveforms, and impedance values. RESULTS: Ventilator settings that produced flow bias had a major effect on mucus movement. Expiratory How bias associated with intrinsic positive end-expiratory pressure generated by elevated minute ventilation moved mucus toward the airway opening, whereas intrinsic positive end-expiratory pressure generated by increased airway resistance moved the mucus toward the lungs. Inter-lung transfer of mucus simulant occurred rapidly across the ""carinal divider"" between interconnected test lungs set to radically different compliances; the mucus moved out of the low-compliance lung and into the high-compliance lung. CONCLUSIONS: The movement of mucus simulant was influenced by the ventilation pattern and lung impedance. Flow bias obtained with ventilator settings may clear or embed mucus during mechanical ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We sought to evaluate this ""response-to-injury"" hypothesis of atherosclerosis by studying the interaction between systolic blood pressure (SBP) and LDL-cholesterol (LDL-C) in predicting the presence of coronary artery calcification (CAC) in asymptomatic men. We Studied 526 men (46 +/- 7 years of age) referred for electron-beam tomography (EBT) exam. The prevalence of CAC was determined across LDL-C tertiles (low: <115 mg/dl; middle: 115-139 mg/dl high: >= 140 mg/dl) within tertiles of SBP (low: <121 mmHg; middle: 121-130 mmHg; high: >= 131 mmHg). CAC was found in 220 (42%) men. There was no linear trend in the presence of CAC across LDL-C tertiles in the low (p = 0.6 for trend) and middle (p = 0.3 for trend) SBP tertile groups, respectively. In contrast, there was a significant trend for increasing CAC with increasing LDL-C (1st: 44%; 2nd: 49%; 3rd: 83%; p < 0.0001 for trend) in the high SBP tertile group. In multivariate logistic analyses (adjusting for age, smoking, triglyceride levels, HDL-cholesterol levels, body mass index, and fasting glucose levels), the odds ratio for any CAC associated with increasing LDL-C was significantly higher in those with highest SBP levels, whereas no such relationship was observed among men with SBP in the lower two tertiles. An interaction term (LDL-C x SBP) incorporated in the multivariate analyses was statistically significant (p = 0.038). The finding of an interaction between SBP and LDL-C relation to CAC in asymptomatic men support the response-to-injury model of atherogenesis. (C) 2007 Elsevier Ireland Ltd. All rights reserved.