904 resultados para pacs: production engineering computing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The next generation of learners expect more informality in learning. Formal learning systems such as traditional LMS systems no longer meet the needs of a generation of learners used to Twitter and Facebook, social networking and user-generated content. Regardless of this, however, formal content and learning models are still important and play a major role in educating learners, particularly in enterprise. The eLite project at DERI addressed this emerging dichotomy of learning styles, reconciling the traditional with the avant garde by using innovative technology to add informal learning capabilities to formal learning architectures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The article introduces the E-learning Circle, a tool developed to assure the quality of the software design process of e-learning systems, considering pedagogical principles as well as technology. The E-learning Circle consists of a number of concentric circles which are divided into three sectors. The content of the inner circles is based on pedagogical principles, while the outer circle specifies how the pedagogical principles may be implemented with technology. The circle’s centre is dedicated to the subject taught, ensuring focus on the specific subject’s properties. The three sectors represent the student, the teacher and the learning objectives. The strengths of the E-learning Circle are the compact presentation combined with the overview it provides, as well as the usefulness of a design tool dealing with complexity, providing a common language and embedding best practice. The E-learning Circle is not a prescriptive method, but is useful in several design models and processes. The article presents two projects where the E-learning Circle was used as a design tool.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Die Fähigkeit zum Lernen durch Abstraktion aus Erfahrungen unterscheidet Experten von Novizen. Wir stellen einen Prozess für individuelles abstrahierendes Lernen und eine diesen Prozess unterstützende Lernumgebung vor. Die Ergebnisse einer Pilotstudie zeigen, dass Lernende unter Nutzung der Lernumgebung aus Fallbeispielen ein abstraktes Modell erstellen und über ihren Prozess reflektieren konnten. Dies fiel ihnen leichter, wenn die Fallbeispiele wenige gemeinsame Oberflächenmerkmale aufwiesen. Im Gegensatz zum intendierten Lernprozess wandten manche Lernende einen anderen Prozess an.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Robotic exoskeletons can be used to study and treat patients with neurological impairments. They can guide and support the human limb over a large range of motion, which requires that the movement trajectory of the exoskeleton coincide with the one of the human arm. This is straightforward to achieve for rather simple joints like the elbow, but very challenging for complex joints like the human shoulder, which is comprised by several bones and can exhibit a movement with multiple rotational and translational degrees of freedom. Thus, several research groups have developed different shoulder actuation mechanism. However, there are no experimental studies that directly compare the comfort of two different shoulder actuation mechanisms. In this study, the comfort and the naturalness of the new shoulder actuation mechanism of the ARMin III exoskeleton are compared to a ball-and-socket-type shoulder actuation. The study was conducted in 20 healthy subjects using questionnaires and 3D-motion records to assess comfort and naturalness. The results indicate that the new shoulder actuation is slightly better than a ball-and-socket-type actuation. However, the differences are small, and under the tested conditions, the comfort and the naturalness of the two tested shoulder actuations do not differ a lot.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many rehabilitation robots use electric motors with gears. The backdrivability of geared drives is poor due to friction. While it is common practice to use velocity measurements to compensate for kinetic friction, breakaway friction usually cannot be compensated for without the use of an additional force sensor that directly measures the interaction force between the human and the robot. Therefore, in robots without force sensors, subjects must overcome a large breakaway torque to initiate user-driven movements, which are important for motor learning. In this technical note, a new methodology to compensate for both kinetic and breakaway friction is presented. The basic strategy is to take advantage of the fact that, for rehabilitation exercises, the direction of the desired motion is often known. By applying the new method to three implementation examples, including drives with gear reduction ratios 100-435, the peak breakaway torque could be reduced by 60-80%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Task-oriented, repetitive and intensive arm training can enhance arm rehabilitation in patients with paralyzed upper extremities due to lesions of the central nervous system. There is evidence that the training duration is a key factor for the therapy progress. Robot-supported therapy can improve the rehabilitation allowing more intensive training. This paper presents the kinematics, the control and the therapy modes of the arm therapy robot ARMin. It is a haptic display with semi-exoskeleton kinematics with four active and two passive degrees of freedom. Equipped with position, force and torque sensors the device can deliver patient-cooperative arm therapy taking into account the activity of the patient and supporting him/her only as much as needed. The haptic display is combined with an audiovisual display that is used to present the movement and the movement task to the patient. It is assumed that the patient-cooperative therapy approach combined with a multimodal display can increase the patient's motivation and activity and, therefore, the therapeutic progress.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the complexity of active medical implants increases, the task of embedding a life-long power supply at the time of implantation becomes more challenging. A periodic renewal of the energy source is often required. Human energy harvesting is, therefore, seen as a possible remedy. In this paper, we present a novel idea to harvest energy from the pressure-driven deformation of an artery by the principle of magneto-hydrodynamics. The generator relies on a highly electrically conductive fluid accelerated perpendicularly to a magnetic field by means of an efficient lever arm mechanism. An artery with 10 mm inner diameter is chosen as a potential implantation site and its ability to drive the generator is established. Three analytical models are proposed to investigate the relevant design parameters and to determine the existence of an optimal configuration. The predicted output power reaches 65 μW according to the first two models and 135 μW according to the third model. It is found that the generator, designed as a circular structure encompassing the artery, should not exceed a total volume of 3 cm3.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Task-oriented repetitive movements can improve muscle strength and movement co-ordination in patients with impairments due to neurological lesions. The application of robotics and automation technology can serve to assist, enhance, evaluate and document the rehabilitation of movements. The paper provides an overview of existing devices that can support movement therapy of the upper extremities in subjects with neurological pathologies. The devices are critically compared with respect to technical function, clinical applicability, and, if they exist, clinical outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

User comfort during simulated driving is of key importance, since reduced comfort can confound the experiment and increase dropout rates. A common comfort-affecting factor is simulator-related transient adverse health effect (SHE). In this study, we propose and evaluate methods to adapt a virtual driving scene to reduce SHEs. In contrast to the manufacturer-provided high-sensory conflict scene (high-SCS), we developed a low-sensory conflict scene (low-SCS). Twenty young, healthy participants drove in both the high-SCS and the low-SCS scene for 10 min on two different days (same time of day, randomized order). Before and after driving, participants rated SHEs by completing the Simulator Sickness Questionnaire (SSQ). During driving, several physiological parameters were recorded. After driving in the high-SCS, the SSQ score increased in average by 129.4 (122.9 %, p = 0.002) compared to an increase of 5.0 (3.4 %, p = 0.878) after driving in the low-SCS. In the low-SCS, skin conductance decreased by 13.8 % (p < 0.01) and saccade amplitudes increased by 16.1 % (p < 0.01). Results show that the investigated methods reduce SHEs in a younger population, and the low-SCS is well accepted by the users. We expect that these measures will improve user comfort.