935 resultados para mass spectrometry, CE-ICP-MS, actinides


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two Meinhard microconcentric nebulizers, model AR30-07-FM02 and AR 30-07-FM005, were employed as a self-installed micro-sampling system for inductively coupled plasma-mass spectrometry (ICP-MS). The FM02 nebulizer at 22 muL/min of solution uptake rate gave the relative standard deviations of 7.6%, 3.0%, 2.7%, 1.8% for determinations (n = 10) of 20 mug/L Be, Co, In and Bi, respectively, and the detection limits (3s) of 0.14, 0.10, 0.02 and 0.01 mug/L for Be, Co In and Bi, respectively. The mass intensity of In-115 obtained by this micro-sampling system was 60% of that by conventional pneumatic nebulizer system at 1.3 mL/min. The analytical results for La, Ce, Pr and Nd in 20 muL Wistar rat amniotic fluid obtained by the present micro-sampling system were precisely in good agreement with those obtained using conventional pneumatic nebulization system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multi-element analysis of honey samples was carried out with the aim of developing a reliable method of tracing the origin of honey. Forty-two chemical elements were determined (Al, Cu, Pb, Zn, Mn, Cd, Tl, Co, Ni, Rb, Ba, Be, Bi, U, V, Fe, Pt, Pd, Te, Hf, Mo, Sn, Sb, P, La, Mg, I, Sm, Tb, Dy, Sd, Th, Pr, Nd, Tm, Yb, Lu, Gd, Ho, Er, Ce, Cr) by inductively coupled plasma mass spectrometry (ICP-MS). Then, three machine learning tools for classification and two for attribute selection were applied in order to prove that it is possible to use data mining tools to find the region where honey originated. Our results clearly demonstrate the potential of Support Vector Machine (SVM), Multilayer Perceptron (MLP) and Random Forest (RF) chemometric tools for honey origin identification. Moreover, the selection tools allowed a reduction from 42 trace element concentrations to only 5. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alkylierte Quecksilberspezies sind hundertfach toxischer als anorganisches Quecksilber (Hg) und werden in der Nahrungskette mit zunehmender Trophieebene im Gewebe von Tieren und dem Menschen akkumuliert. Aufgrund der Relevanz für die Umwelt und den Effekt auf die menschliche Gesundheit kommt der biotischen Transformation von anorganischem Hg zu Monomethylquecksilber (MeHg) eine große Bedeutung zu. Es ist bekannt, dass Sulfat-reduzierende Bakterien zu den Hauptproduzenten von MeHg gehören. Darüber hinaus gibt es jedoch nur wenige Untersuchungen über die biologischen Mechanismen und die Zusammenhänge in terrestrischen und insbesondere in intestinalen Systemen. Die vorliegende Arbeit leistet daher einen wichtigen Beitrag zur Abschätzung des Potentials zur Hg-Methylierung durch intestinale Bakterien und vertieft die Kenntnisse zu der damit verbundenen Akkumulation der organischen Schwermetallverbindung im Gewebe des Kompostwurms Eisenia foetida (E. foetida). rnIm Rahmen dieser Arbeit wurde erstmals unter Anwendung der Gas Chromatographie mit induktiv gekoppelter Massenspektrometrie (GC-ICP-MS) und Isotopenverdünnungsanalyse verschiedene Kulturen intestinaler Sulfat-reduzierender Bakterien auf die Bildung von organischem Monomethylquecksilber aus Hg(II) untersucht. Da in komplexen bakteriellen Nährlösungen mit hohem Sulfidgehalt Matrixeffekte auftreten und die Analyse von MeHg im Ultraspurenbereich erschweren können, erfolgte die Probenvorbereitung mittels der Methanol-Kaliumhydroxid-Extraktion unter Verwendung eines Maskierungsreagenzes und der Derivatisierung mit Natriumtetrapropylborat. Das Detektionslimit für MeHg in bakteriellen Nährlösungen betrug 0,03 ng/mL. Die Wiederfindung von zertifiziertem Referenzmaterial ERM® CE-464 Tuna Fish war sehr gut und lag in einem Bereich zwischen 98 – 105%. rnDie Resultate der Untersuchung von 14 verschiedenen Rein- und Anreicherungskulturen Sulfat-reduzierender Bakterien zeigten, dass neun Kulturen innerhalb von 12 h nach einer Inkubation mit 0,1 mg/L Hg2+ im Durchschnitt 100 bis 1200 pg/mL MeHg produzierten. Darunter waren zwei Desulfovibrio sp. Stämme, die Spezies Desulfovibrio piger, Desulfovibrio giganteus, Desulfovibrio termitidis, Desulfotomaculum ruminis, Desulfobulbus propionicus sowie Anreicherungskulturen aus dem Intestinaltrakt einer Zygoptera-Larve Zy1 und E. foetida EF4. Die Fähigkeit zur Hg-Methylierung durch eine Spezies der Ordnung Desulfotomaculum aus der Gruppe der Gram-positiven Firmicutes wurde hiermit erstmals beobachtet.rnWeiterhin wurde gezeigt, dass im Intestinaltrakt von E. foetida im Gegensatz zu mikrobiellen Bodenproben eine signifikante biotische Methylierung von Hg(II) durchgeführt wird. Dass diese Transformationen in hohem Maße von der intestinalen Region ausgeht und somit zur Akkumulation von MeHg im Gewebe beiträgt, konnte durch weiterführende Experimente mittels Laserablations-ICP-MS an histologischen Gefrierschnitten des Invertebraten darge-stellt werden. rn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Als paläoklimatische Archive können unter anderem Stalagmiten und Klappen von Ostrakoden herangezogen werden. Bisher gab es noch keine veröffentlichten Ergebnisse räumlich hochaufgelöster Spurenelementverteilungen in einzelnen Ostrakodenklappen. Das gleiche gilt für die Bestimmung radiogener Blei-Isotope in Stalagmiten. Um klimatische Prozesse vergangener Zeiten zu untersuchen, wurde eine neue LA-ICP-MS (Laserablations – Massenspektrometrie mit induktiv gekoppeltem Plasma) Technik für hochaufgelöste in-situ Messungen von Spurenelementen und Bleiisotopen entwickelt. rnrnZunächst wurden geeignete Materialien für die Kalibrierung der Technik untersucht; als Proben dienten die Silikatreferenzgläser BAM-S005-A und BAM-S005B der Bundesanstalt für Materialforschung und –prüfung (BAM). Die Homogenität dieser Referenzgläser wurde mit LA-ICP-MS und den anderen mikroanalytischen Methoden EPMA (Elektronenmikrosonde) und SIMS (Ionensonde) überprüft. Die Ergebnisse zeigten, dass alle Haupt- und die meisten Spurenelemente in beiden Gläsern selbst im Mikrometerbereich homogen verteilt sind. Ausnahmen sind einige Spurenelemente, wie Cs, Cl, Cr, Mo und Ni, die heterogen in den Gläsern verteilt sind. Die Hauptelementzusammensetzung von BAM-S005-A und BAM-S005-B wurde mit Hilfe der EPMA bestimmt, wobei die Ergebnisse die Referenzwerte des BAM-Zertifikats bestätigten. Mit Ausnahme von Sr, Ba, Ce und Pb, stimmten die LA-ICP-MS-Spurenelementwerte mit den zertifizierten Werten innerhalb der angegebenen Fehlergrenzen überein. Gründe für die Diskrepanz der vier oben erwähnten Elemente sind noch unklar, aber sind möglicherweise durch fehlerhafte Referenzwerte zu erklären. Zusätzlich wurden 22 Spurenelemente gemessen, deren Gehalte von BAM nicht zertifiziert wurden. Aufgrund dieser Untersuchungen konnte festgestellt werden, dass beide BAM-Gläser für mikroanalytische Anwendungen geeignet sind.rnrnUm neuartige paläoklimatische Proxies im Calcit von Ostrakoden aus tibetanischen Seesedimenten zu untersuchen, wurde die Spurenelementvariabilität in einzelnen Ostrakodenklappen durch eine neue LA-ICP-MS-Technik bestimmt. Klappen von Ostrakoden der drei Arten (Leucocytherella sinensis Huang, 1982, ?Leucocythere dorsotuberosa Huang, 1982 und ?L. dorsotuberosa f. postilirata sensu Pang, 1985) wurden aus zwei Sedimentkernen des Nam Co Sees auf dem Hochplateau von Tibet gewonnen. Zwei LA-ICP-MS-Varianten, Spot- bzw. Linienanalyse, wurden verwendet, um die Elementkonzentrationen der Spurenelemente Mg, Sr, Ba, U und die der Seltenen Erdelemente (SEE) in den Klappen einzelner Ostrakoden zu bestimmen. Die Ergebnisse zeigten, dass die Linienanalyse präzisere Daten als die Spotanalyse liefert und sie wurde daher vorgezogen. Signifikante Unterschiede in der Spurenelementzusammensetzung zwischen den verschiedenen Arten der Ostrakoden wurden nicht gefunden. Variationen der Elementverhältnisse Mg/Ca und Sr/Ca in den Klappen stimmen mit veröffentlichten Seenspiegelschwankungen während des Holozäns überein, was zeigt, dass Mg- und Sr-Messungen in den Ostrakoden zur Untersuchung paläohydrochemischer Prozesse in diesem Gebiet herangezogen werden kann. Die gute Korrelation, die in dieser Arbeit zwischen Ba/Ca und Sr/Ca gefunden wurde, ist ein Hinweis darauf, dass der Einbau von Ba und Sr in die Klappen durch den gleichen Mechanismus erfolgte. Eine mögliche Beziehung zwischen dem U/Ca-Verhältnis in den Ostrakoden und den Redoxbedingungen auf dem Boden des Sees in der Vergangenheit wird diskutiert. Relativ geringe und konstante La/Ca-Verhältnisse wurden festgestellt, deren Ursache möglicherweise entweder auf der SEE-Charakteristik des Seewassers, auf biologischen Prozessen in den Ostrakoden oder auf Kontamination von Fe-Mn und/oder organischen Substanzen beruhen. Weitere Untersuchungen an Proben aus diesem Gebiet, speziell Klappen von lebenden Ostrakoden, sind notwendig, um den Gehalt von Ba, U und den SEE in Ostrakoden als paläoklimatische Proxies von Umweltbedingungen zu verwenden.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Natural radionuclides and man-made 137Cs were analyzed in five short sediment cores taken in northern part of the Gulf of Eilat (Gulf of Aqaba) in order to provide information on sedimentation and mixing rates and sediment sources. The maximum estimates of sedimentation rates based on excess 210Pb were found to vary between 0.105 ± 0.020 and 0.35 ± 0.23 cm · year**-1. Even the lowest estimates are significantly higher than those expected from dust deposition, suggesting other sources and processes being responsible for most of the allochthonous material accumulation, including periodical floods following heavy rain events, internal erosion or triggers, like earthquakes. In 137Cs depth profiles no 1963 related nuclear weapon test maxima were found; instead, the activities decrease monotonically, suggesting that a major process leading to radionuclides' depth distribution might be mixing. The mixing rates calculated from 137Cs, excess 210Pb and excess 228Th reach values up to 2.18 ± 0.69 cm**2 · year**-1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thermogravimetric analysis-mass spectrometry, X-ray diffraction and scanning electron microscopy (SEM) were used to characterize eight kaolinite samples from China. The results show that the thermal decomposition occurs in three main steps (a) desorption of water below 100 °C, (b) dehydration at about 225 °C, (c) well defined dehydroxylation at around 450 °C. It is also found that decarbonization took place at 710 °C due to the decomposition of calcite impurity in kaolin. The temperature of dehydroxylation of kaolinite is found to be influenced by the degree of disorder of the kaolinite structure and the gases evolved in the decomposition process can be various because of the different amount and kinds of impurities. It is evident by the mass spectra that the interlayer carbonate from impurity of calcite and organic carbon is released as CO2 around 225, 350 and 710 °C in the kaolinite samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A combined data matrix consisting of high performance liquid chromatography–diode array detector (HPLC–DAD) and inductively coupled plasma-mass spectrometry (ICP-MS) measurements of samples from the plant roots of the Cortex moutan (CM), produced much better classification and prediction results in comparison with those obtained from either of the individual data sets. The HPLC peaks (organic components) of the CM samples, and the ICP-MS measurements (trace metal elements) were investigated with the use of principal component analysis (PCA) and the linear discriminant analysis (LDA) methods of data analysis; essentially, qualitative results suggested that discrimination of the CM samples from three different provinces was possible with the combined matrix producing best results. Another three methods, K-nearest neighbor (KNN), back-propagation artificial neural network (BP-ANN) and least squares support vector machines (LS-SVM) were applied for the classification and prediction of the samples. Again, the combined data matrix analyzed by the KNN method produced best results (100% correct; prediction set data). Additionally, multiple linear regression (MLR) was utilized to explore any relationship between the organic constituents and the metal elements of the CM samples; the extracted linear regression equations showed that the essential metals as well as some metallic pollutants were related to the organic compounds on the basis of their concentrations

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wet-milling protocol was employed to produce pressed powder tablets with excellent cohesion and homogeneity suitable for laser ablation (LA) analysis of volatile and refractive elements in sediment. The influence of sample preparation on analytical performance was also investigated, including sample homogeneity, accuracy and limit of detection. Milling in volatile solvent for 40 min ensured sample is well mixed and could reasonably recover both volatile (Hg) and refractive (Zr) elements. With the exception of Cr (−52%) and Nb (+26%) major, minor and trace elements in STSD-1 and MESS-3 could be analysed within ±20% of the certified values. Comparison of the method with total digestion method using HF was tested by analysing 10 different sediment samples. The laser method recovers significantly higher amounts of analytes such as Ag, Cd, Sn and Sn than the total digestion method making it a more robust method for elements across the periodic table. LA-ICP-MS also eliminates the interferences from chemical reagents as well as the health and safety risks associated with digestion processes. Therefore, it can be considered as an enhanced method for the analysis of heterogeneous matrices such as river sediments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Miniaturization of analytical instrumentation is attracting growing interest in response to the explosive demand for rapid, yet sensitive analytical methods and low-cost, highly automated instruments for pharmaceutical and bioanalyses and environmental monitoring. Microfabrication technology in particular, has enabled fabrication of low-cost microdevices with a high degree of integrated functions, such as sample preparation, chemical reaction, separation, and detection, on a single microchip. These miniaturized total chemical analysis systems (microTAS or lab-on-a-chip) can also be arrayed for parallel analyses in order to accelerate the sample throughput. Other motivations include reduced sample consumption and waste production as well as increased speed of analysis. One of the most promising hyphenated techniques in analytical chemistry is the combination of a microfluidic separation chip and mass spectrometer (MS). In this work, the emerging polymer microfabrication techniques, ultraviolet lithography in particular, were exploited to develop a capillary electrophoresis (CE) separation chip which incorporates a monolithically integrated electrospray ionization (ESI) emitter for efficient coupling with MS. An epoxy photoresist SU-8 was adopted as structural material and characterized with respect to its physicochemical properties relevant to chip-based CE and ESI/MS, namely surface charge, surface interactions, heat transfer, and solvent compatibility. As a result, SU-8 was found to be a favorable material to substitute for the more commonly used glass and silicon in microfluidic applications. In addition, an infrared (IR) thermography was introduced as direct, non-intrusive method to examine the heat transfer and thermal gradients during microchip-CE. The IR data was validated through numerical modeling. The analytical performance of SU-8-based microchips was established for qualitative and quantitative CE-ESI/MS analysis of small drug compounds, peptides, and proteins. The CE separation efficiency was found to be similar to that of commercial glass microchips and conventional CE systems. Typical analysis times were only 30-90 s per sample indicating feasibility for high-throughput analysis. Moreover, a mass detection limit at the low-attomole level, as low as 10E+5 molecules, was achieved utilizing MS detection. The SU-8 microchips developed in this work could also be mass produced at low cost and with nearly identical performance from chip to chip. Until this work, the attempts to combine CE separation with ESI in a chip-based system, amenable to batch fabrication and capable of high, reproducible analytical performance, have not been successful. Thus, the CE-ESI chip developed in this work is a substantial step toward lab-on-a-chip technology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foreign compounds, such as drugs are metabolised in the body in numerous reactions. Metabolic reactions are divided into phase I (functionalisation) and phase II (conjugation) reactions. Uridine diphosphoglucuronosyltransferase enzymes (UGTs) are important catalysts of phase II metabolic system. They catalyse the transfer of glucuronic acid to small lipophilic molecules and convert them to hydrophilic and polar glucuronides that are readily excreted from the body. Liver is the main site of drug metabolism. Many drugs are racemic mixtures of two enantiomers. Glucuronidation of a racemic compound yields a pair of diastereomeric glucuronides. Stereoisomers are interesting substrates in glucuronidation studies since some UGTs display stereoselectivity. Diastereomeric glucuronides of O-desmethyltramadol (M1) and entacapone were selected as model compounds in this work. The investigations of the thesis deal with enzymatic glucuronidation and the development of analytical methods for drug metabolites, particularly diastereomeric glucuronides. The glucuronides were analysed from complex biological matrices, such as urine or from in vitro incubation matrices. Various pretreatment techniques were needed to purify, concentrate and isolate the analytes of interest. Analyses were carried out by liquid chromatography (LC) with ultraviolet (UV) or mass spectrometric (MS) detection or with capillary electromigration techniques. Commercial glucuronide standards were not available for the studies. Enzyme-assisted synthesis with rat liver microsomes was therefore used to produce M1 glucuronides as reference compounds. The glucuronides were isolated by LC/UV and ultra performance liquid chromatography (UPLC)/MS, while tandem mass spectrometry (MS/MS) and nuclear magnetic resonance (NMR) spectroscopy were employed in structural characterisation. The glucuronides were identified as phenolic O-glucuronides of M1. To identify the active UGT enzymes in (±)-M1 glucuronidation recombinant human UGTs and human tissue microsomes were incubated with (±)-M1. The study revealed that several UGTs can catalyse (±)-M1 glucuronidation. Glucuronidation in human liver microsomes like in rat liver microsomes is stereoselective. The results of the studies showed that UGT2B7, most probably, is the main UGT responsible for (±)-M1 glucuronidation in human liver. Large variation in stereoselectivity of UGTs toward (±)-M1 enantiomers was observed. Formation of M1 glucuronides was monitored with a fast and selective UPLC/MS method. Capillary electromigration techniques are known for their high resolution power. A method that relied on capillary electrophoresis (CE) with UV detection was developed for the separation of tramadol and its free and glucuronidated metabolites. The suitability of the method to identify tramadol metabolites in an authentic urine samples was tested. Unaltered tramadol and four of its main metabolites were detected in the electropherogram. A micellar electrokinetic chromatography (MEKC) /UV method was developed for the separation of the glucuronides of entacapone in human urine. The validated method was tested in the analysis of urine samples of patients. The glucuronides of entacapone could be quantified after oral entacapone dosing.