891 resultados para displacement force
Resumo:
Ballet gestures are highly non-anatomical and physiological, leading to compensatory behaviors. The knee joint is most affected by this behavior, leading to an increase risk of injury. Our purpose is to describe the knee angular displacement in amateur dancers, during a demi-plié exercise, with emphasis on valgus mechanisms frequency. Methods: 192 demi-pliés collected in six amateur female dancers (mean age = 15.33 ± 1.37 years), were analyzed regarding sagittal and frontal plane angular displacement, with an electrogoniometer connected to a signal acquisition unit at 1000 Hz. Results: all subjects presented valgus peaks along the trials, despite the global varus tendency of the knee frontal plane behavior. A significant positive correlation between the frequency of valgus and practice time was noted. Discussion: A variable angular frontal displacement was observed, with some trials comprehending a high incidence of valgus peaks along the ascending or descending phase of the demi-plié exercise. Conclusion: the frontal knee angle behavior is variable. It may present fast peaks of valgus or an initial trend of varus/valgus that is different from the global varus trend. The analysis of the activity should be considered in the training. The practice time may be related to the observed behavior.
Resumo:
Este trabalho descreve as actividades desenvolvidas no âmbito de uma task-force para revitalizar a função Sistemas de Informação de uma grande empresa nacional. Apresenta, em particular, o sistema de indicadores de gestão definido nesse contexto
Resumo:
Introdução: A correta avaliação das capacidades do idoso será fundamental na diminuição do risco de queda inerente ao envelhecimento. Os Smartphones são uma boa ferramenta para a avaliação das capacidades em idosos. Objetivo: Verificar se o smartphone é uma ferramenta de avaliação do ângulo de dorsiflexão ativa da tibiotársica (Dors. TT) e em diferentes parâmetros relacionados com a marcha. ; Métodos: Estudo transversal correlacional, com amostra composta por 27 indivíduos com mais de 60 anos. Procedeu-se à recolha de dados através de um sistema de análise cinemática em 3D com conexão a uma plataforma de forças e de uma aplicação para Smartphone (Fraunhofer®, Porto, Portugal), de forma a verificar a funcionalidade desta última. As variáveis medidas foram a Dors. TT; e todas a variáveis relacionadas com a marcha. Resultados: A dors. TT apresentou uma correlação forte positiva (rs=0,8; p<0,001) entre os dados dos dois instrumentos, assim como no balanço pélvico (rp=0,8; p<0,001), na velocidade na marcha (rp=0,7; p<0,001) e no nº de passos posteriores (rs=0,8; p<0,001). Observou-se uma correlação moderada positiva na duração do passo direito, na duração do passo, na duração da passada, na cadência, no comprimento do passo esq., no comprimento do passo e no deslocamento lateral da pélvis (rp=0,6; p≤0.008). Na percentagem da fase de apoio (%FA) (rs =-0.6; p= 0.007) e na medição da cadência lateral (rs =-0.4; p= 0.042) observou-se uma correlação moderada negativa e na cad. post. (rs=-0,7; p<0,001) uma correlação forte negativa. Conclusão: A aplicação para Smartphone parece ser uma ferramenta útil para avaliar corretamente o ângulo de dorsiflexão da tibiotársica, a contagem do número de passos no sentido posterior, o balanço pélvico e a velocidade. Contudo, necessita ser reajustada para as outras variáveis.
Resumo:
Este trabalho insere-se no domínio da calibração energética dos equipamentos SPT, dando seguimento ao disposto na norma EN ISO 22476-3, de aplicação obrigatória em Portugal. Para tal foi utilizada uma vara instrumentada, cuja instrumentação consiste em strain-gauges e acelerómetros piezoeléctricos. Esta instrumentação encontra-se fixa a um trecho de vara com comprimento de 60 cm e para a aquisição dos dados foi utilizado o sistema SPT Analyzer® comercializado pela firma PDI. O sistema permite registar os dados provenientes da instrumentação: sinais de um par de strain-gauges, transformados em registos de força (F1 e F2) e sinais de um par de acelerómetros, convertidos em registos de velocidade (V1 e V2) ao longo do tempo. O equipamento permite a avaliação, em tempo real, da qualidade dos registos e da energia máxima transmitida à vara em cada golpe e o conhecimento do deslocamento vertical do trem de varas ocorrido em cada golpe do martelo. Por outro lado, baseando-se no tema acima referido, pretende-se ainda desenvolver esforços no sentido de melhorar o novo método interpretativo dos resultados dos ensaios SPT e sua aplicação ao dimensionamento de estacas, dado que a previsão da capacidade de carga de estacas constitui um dos desafios da engenharia de fundações por requerer a estimativa de propriedades do solo, alterações pela execução da fundação e conhecimento do mecanismo de interacção solo-estaca. Este novo procedimento baseia-se nos princípios da dinâmica, rompendo com as metodologias até aqui consagradas, de natureza essencialmente empírica. A nova forma de interpretar os ensaios SPT, consubstanciada nos princípios de conservação de energia na cravação do amostrador SPT, irá permitir converter analiticamente o valor Nspt numa força dinâmica de reacção à penetração. A decomposição desta força dinâmica permite efectuar análises comparativas entre as resistências unitárias mobilizadas no amostrador SPT (modelo) e as mobilizadas na estaca (protótipo).
Resumo:
As indústrias de componentes e acessórios automóveis são um elo fundamental no processo produtivo da indústria automóvel. Neste leque industrial encontra-se a Preh Portugal, Lda, como empresa fornecedora de componentes electrónicos, mais concretamente, painéis de controlo de climatização. Os painéis fornecidos pela Preh aos seus clientes encontram-se sujeitos a rigorosos testes de qualidade e funcionalidade. Neste sentido o teste funcional das teclas surge, relacionando o curso da tecla em função de uma força actuante. Esta relação está comprometida com uma curva característica padrão para o tipo de tecla. Para além destes compromissos, também é necessário que a tecla feche e abra o seu contacto eléctrico. Esta tese foca-se no desenvolvimento do teste de teclas, apresentando uma alteração ao sistema actual com a introdução de um sistema embebido, no intuito de flexibilizar o sistema de teste e reduzindo custos. O sistema embebido pretende dar capacidade de processamento ao teste e, desta forma, substituir o actual computador como elemento de processamento. A solução implementada consistiu numa mudança estrutural, através da inclusão do sistema embebido entre o computador e o sistema de deslocamento. Passando o foco central do processo de teste a residir no sistema embebido, este tem de estabelecer comunicações com os restantes elementos intervenientes no teste. Estabelece comunicações série RS-232 com o sistema de deslocamento (leitura do curso e força na tecla), Ethernet com o computador (comandos, parâmetros e resultados) e CAN com o painel de controlo de climatização (fecho/abertura do contacto eléctrico). A concretização deste projecto resultou numa nova estrutura e aplicação, a qual é facilmente integrada na linha de produção com as vantagens de ser menos onerosa e mais flexível, conforme o pretendido.
Resumo:
This study investigated the influence of wearing unstable shoe construction (WUS) on compensatory postural adjustments (CPA) associated with external perturbations. Thirty-two subjects stood on a force platform resisting an anterior-posterior horizontal force applied to a pelvic belt via a cable, which was suddenly released. They stood under two conditions: barefoot and WUS. The electromyographic (EMG) activity of gastrocnemius medialis, tibialis anterior, rectus femoris, biceps femoris, rectus abdominis, and erector spinae muscles and the center of pressure (CoP) displacement were acquired to study CPA. The EMG signal was used to assess individual muscle activity and latency, antagonist co-activation and reciprocal activation at joint and muscle group levels. Compared to barefoot, WUS led to: (1) increased gastrocnemius medialis activity, (2) increased total agonist activity, (3) decreased antagonist co-activation at the ankle joint and muscle group levels, (4) increased reciprocal activation at the ankle joint and muscle group levels, and (5) decrease in all muscle latencies. No differences were observed in CoP displacement between conditions. These findings demonstrate that WUS led to a reorganization of the postural control system associated to improved performance of some components of postural control responses.
Resumo:
Purpose: This study investigated the influence of long-term wearing of unstable shoes (WUS) on compensatory postural adjustments (CPA) to an external perturbation. Methods: Participants were divided into two groups: one wore unstable shoes while the other wore conventional shoes for 8 weeks. The ground reaction force signal was used to calculate the anterior– posterior (AP) displacement of the centre of pressure (CoP) and the electromyographic signal of gastrocnemius medialis (GM), tibialis anterior (TA), rectus femoris (RF) and biceps femoris (BF) muscles was used to assess individual muscle activity, antagonist co-activation and reciprocal activation at the joint (TA/GM and RF/(BF + GM) pairs) and muscle group levels (ventral (TA + RF)/dorsal (GM + BF) pair) within time intervals typical for CPA. The electromyographic signal was also used to assess muscle latency. The variables described were evaluated before and after the 8-week period while wearing the unstable shoes and barefoot. Results: Long-term WUS led to: an increase of BF activity in both conditions (barefoot and wearing the unstable shoes); a decrease of GM activity; an increase of antagonist co-activation and a decrease of reciprocal activation level at the TA/GM and ventral/dorsal pairs in the unstable shoe condition. Additionally, WUS led to a decrease in CoP displacement. However, no differences were observed in muscle onset and offset. Conclusion: Results suggest that the prolonged use of unstable shoes leads to increased ankle and muscle groups’ antagonist co-activation levels and higher performance by the postural control system.
Resumo:
In the injection moulding of polypropylene reinforced with hard glass fibres, die materials are commonly subjected to severe abrasive wear. In order to improve its wear resistance, an unbalanced magnetron sputtering PVD compositional monolayered coating has been produced. The film was composed by a nanostructured TiB2 monolayer. Microstructure characterization and thickness evaluation were conducted by scanning electron microscopy (SEM). Film topography and roughness were accessed by SEM and Atomic Force Microscopy (AFM). The phase analyse was investigated by X-ray diffraction (XRD), using Cu Kalpha radiation. Scratch tests were conducted in order to study the film adhesion to the substrate. Load-Displacement curves (nanoindentation analysis) allowed measuring the film hardness and Young's modulus. A ball-cratering tribometer was used to determine the micro-abrasion laboratorial wear resistance, under different tests conditions, using SiC particles in distilled water slurry. At the end of these tests, the worn surfaces were analyzed by SEM and Energy Dispersive X-ray Spectroscopy (EDS) in order to compare these results with some other coatings already tested in the same conditions. To test the practical wear resistance, 135000 injection cycles were done in a plastic injection industrial mould. Coated samples were put on the plastic feed canal, after a turbulent zone. In these tests, a 30% (wt) glass fibres reinforced polypropylene was used. Worn sample surfaces were analyzed by SEM after 45.000 and 90.000 cycles. Image analyses were made in order to evaluate the damage increases and to observe the wear mechanisms involved.
Resumo:
Measurements in civil engineering load tests usually require considerable time and complex procedures. Therefore, measurements are usually constrained by the number of sensors resulting in a restricted monitored area. Image processing analysis is an alternative way that enables the measurement of the complete area of interest with a simple and effective setup. In this article photo sequences taken during load displacement tests were captured by a digital camera and processed with image correlation algorithms. Three different image processing algorithms were used with real images taken from tests using specimens of PVC and Plexiglas. The data obtained from the image processing algorithms were also compared with the data from physical sensors. A complete displacement and strain map were obtained. Results show that the accuracy of the measurements obtained by photogrammetry is equivalent to that from the physical sensors but with much less equipment and fewer setup requirements. © 2015Computer-Aided Civil and Infrastructure Engineering.
Resumo:
The objective of the article is to evaluate the impact of the friction force mouse-pad in the contraction level of the forearm muscles M. extensor carpi ulnaris, M. extensor digitorum and M. extensor carpi radialis longus. A standard protocol of mouse movements was performed involving horizontal, vertical and diagonal mouse displacements drag-and-drop type. The operators were instructed to execute the protocol with their normal working speed. The movements protocol were performed by each subject (n=17) with three selected pairs mouse-pad, classified as low, medium and high friction force pairs. The mean time to execute the protocol with each mouse was ~138s. Mean values of ~13%MVE and ~17%MVE were found in the M. extensor carpi ulnaris and in the M. extensor digitorum respectively when performing the movements’ protocol. A 8.1% increase in %MVE was observed in the M. extensor digitorum and a 9.4% increase in %MVE was observed in the M. extensor carpi ulnaris when the high friction force pair was operated, relatively to the low friction force pair (p<0.05). The main preliminary conclusions of this study is that operating a high friction force mouse-pad may increase the risk to symptoms or disorders in the wrist due to an increase in the forearm muscles contraction levels, particularly during work with drawing application
Resumo:
Postural control deficits are the most disabling aspects of Parkinson's disease (PD), resulting in decreased mobility and functional independence. The aim of this study was to assess the postural control stability, revealed by variables based on the centre of pressure (CoP), in individuals with PD while performing a sit-to-stand-to-sit sequence under single- and dual-task conditions. An observational, analytical and cross-sectional study was performed. The sample consisted of 9 individuals with PD and 9 healthy controls. A force platform was used to measure the CoP displacement and velocity during the sit-to-stand-to-sit sequence. The results were statistically analysed. Individuals with PD required greater durations for the sit-to-stand-to-sit sequence than the controls (p < 0.05). The anteroposterior and mediolateral CoP displacement were higher in the individuals with PD (p < 0.05). However, only the anteroposterior CoP velocity in the stand-to-sit phase (p = 0.006) was lower in the same individuals. Comparing the single- and dual-task conditions in both groups, the duration, the anteroposterior CoP displacement and velocity were higher in the dual-task condition (p < 0.05). The individuals with PD presented reduced postural control stability during the sit-to-stand-to-sit sequence, especially when under the dual-task condition. These individuals have deficits not only in motor performance, but also in cognitive performance when performing the sit-to-stand-to-sit sequence in their daily life tasks. Moreover, both deficits tend to be intensified when two tasks are performed simultaneously.
Resumo:
Although the issue of the out-of-plane response of unreinforced masonry structures under earthquake excitation is well known with consensus among the research community, this issue is simultaneously one of the more complex and most neglected areas on the seismic assessment of existing buildings. Nonetheless, its characterization should be found on the solid knowledge of the phenomenon and on the complete understanding of methodologies currently used to describe it. Based on this assumption, this article presents a general framework on the issue of the out-of-plane performance of unreinforced masonry structures, beginning with a brief introduction to the topic, followed by a compact state of art in which the principal methodologies proposed to assess the out-of-plane behavior of unreinforced masonry structures are presented. Different analytical approaches are presented, namely force and displacement-based, complemented with the presentation of existing numerical tools for the purpose presented above. Moreover, the most relevant experimental campaigns carried out in order to reproduce the phenomenon are reviewed and briefly discussed.
Resumo:
The seismic assessment of the local failure modes in existing masonry buildings is currently based on the identification of the so-called local mechanisms, often associated with the out-of-plane wall behavior, whose stability is evaluated by static force-based approaches and, more recently, by some displacement-based proposals. Local mechanisms consist of kinematic chains of masonry portions, often regarded as rigid bodies, with geometric nonlinearity and concentrated nonlinearity in predefined contact regions (unilateral no-tension behavior, possible sliding with friction). In this work, the dynamic behavior of local mechanisms is simulated through multi-body dynamics, to obtain the nonlinear response with efficient time history analyses that directly take into account the characteristics of the ground motion. The amplification/filtering effects of the structure are considered within the input motion. The proposed approach is validated with experimental results of two full-scale shaking-table tests on stone masonry buildings: a sacco-stone masonry façade tested at Laboratório Nacional de Engenharia Civil and a two-storey double-leaf masonry building tested at European Centre for Training and Research in Earthquake Engineering (EUCENTRE).
Resumo:
Relatório de Estágio apresentado para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Ciência Política e Relações Internacionais, na variante de Estudos Europeus
Resumo:
Allergy affects at least one-quarter of European schoolchildren, it reduces quality of life and may impair school performance; there is a risk of severe reactions and, in rare cases, death. Allergy is a multi-system disorder, and children often have several co-existing diseases, i.e. allergic rhinitis, asthma, eczema and food allergy. Severe food allergy reactions may occur for the first time at school, and overall 20% of food allergy reactions occur in schools. Up to two-thirds of schools have at least one child at risk of anaphylaxis but many are poorly prepared. A cooperative partnership between doctors, community and school nurses, school staff, parents and the child is necessary to ensure allergic children are protected. Schools and doctors should adopt a comprehensive approach to allergy training, ensuring that all staff can prevent, recognize and initiate treatment of allergic reactions.