921 resultados para denaturing high-performance liquid chromatography (DHPLC) sequencing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study measured a chemotherapy drug, etoposide, in pig cerebrospinal fluid after intraventricular administrations were made directly into the fourth ventricle of the brain; cytotoxic concentrations for a twenty-four hour period after infusions. The analytical method developed validates the potential treatment of malignant brain tumors. The increase in serum carotenoid concentration in 30 healthy individuals was measured after supplementation with lutein. HPLC analysis of serum levels of carotenoids showed an increase in the concentration of lutein and a constant concentration of other major serum carotenoids. An initial attempt to measure the enthalpy of aggregation of xanthophylls was conducted by using ultraviolet-visible spectroscopy. The enthalpy of lutein aggregation and AH range of zeaxanthin disordering of aggregation are reported. Monomethyl ether of lutein did not aggregate in any of the aqueous solutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Existing instrumental techniques must be adaptable to the analysis of novel explosives if science is to keep up with the practices of terrorists and criminals. The focus of this work has been the development of analytical techniques for the analysis of two types of novel explosives: ascorbic acid-based propellants, and improvised mixtures of concentrated hydrogen peroxide/fuel. In recent years, the use of these explosives in improvised explosive devices (IEDs) has increased. It is therefore important to develop methods which permit the identification of the nature of the original explosive from post-blast residues. Ascorbic acid-based propellants are low explosives which employ an ascorbic acid fuel source with a nitrate/perchlorate oxidizer. A method which utilized ion chromatography with indirect photometric detection was optimized for the analysis of intact propellants. Post-burn and post-blast residues if these propellants were analyzed. It was determined that the ascorbic acid fuel and nitrate oxidizer could be detected in intact propellants, as well as in the post-burn and post-blast residues. Degradation products of the nitrate and perchlorate oxidizers were also detected. With a quadrupole time-of-flight mass spectrometer (QToFMS), exact mass measurements are possible. When an HPLC instrument is coupled to a QToFMS, the combination of retention time with accurate mass measurements, mass spectral fragmentation information, and isotopic abundance patterns allows for the unequivocal identification of a target analyte. An optimized HPLC-ESI-QToFMS method was applied to the analysis of ascorbic acid-based propellants. Exact mass measurements were collected for the fuel and oxidizer anions, and their degradation products. Ascorbic acid was detected in the intact samples and half of the propellants subjected to open burning; the intact fuel molecule was not detected in any of the post-blast residue. Two methods were optimized for the analysis of trace levels of hydrogen peroxide: HPLC with fluorescence detection (HPLC-FD), and HPLC with electrochemical detection (HPLC-ED). Both techniques were extremely selective for hydrogen peroxide. Both methods were applied to the analysis of post-blast debris from improvised mixtures of concentrated hydrogen peroxide/fuel; hydrogen peroxide was detected on variety of substrates. Hydrogen peroxide was detected in the post-blast residues of the improvised explosives TATP and HMTD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A comprehensive forensic investigation of sensitive ecosystems in the Everglades Area is presented. Assessing the background levels of contamination in these ecosystems represents a vital resource to build up forensic evidence required to enforce future environmental crimes within the studied areas. This investigation presents the development and validation of a fractionation and isolation method for two families of herbicides commonly applied in the vicinity of the study area, including phenoxy acids like 2,4-D, MCPA, and silvex; as well as the most common triazine-based herbicides like atrazine, prometyne, simazine and related metabolites like DIA and DEA. Accelerated solvent extraction (ASE) and solid phase extraction (SPE) were used to isolate the analytes from abiotic matrices containing large amounts of organic material. Atmospheric-pressure ionization (API) with electrospray ionization in negative mode (ESP-), and Chemical Ionization in the positive mode (APCI+) were used to perform the characterization of the herbicides of interest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We quantified pigment biomarkers by high performance liquid chromatography (HPLC) to obtain a broad taxonomic classification of microphytobenthos (MPB) (i.e. identification of dominant taxa). Three replicate sediment cores were collected at 0, 50 and 100 m along transects 5-9 in Heron Reef lagoon (n=15) (Fig. 1). Transects 1-4 could not be processed because the means to have the samples analysed by HPLC were not available at the time of field data collection. Cores were stored frozen and scrapes taken from the top of each one and placed in cryovials immersed in dry ice. Samples were sent to the laboratory (CSIRO Marine and Atmospheric Research, Hobart, Australia) where pigments were extracted with 100% acetone during fifteen hours at 4°C after vortex mixing (30 seconds) and sonication (15 minutes). Samples were then centrifuged and filtered prior to the analysis of pigment composition with a Waters - Alliance HPLC system equipped with a photo-diode array detector. Pigments were separated using a Zorbax Eclipse XDB-C8 stainless steel 150 mm x 4.6 mm ID column with 3.5 µm particle size (Agilent Technologies) and a binary gradient system with an elevated column temperature following a modified version of the Van Heukelem and Thomas (2001) method. The separated pigments were detected at 436 nm and identified against standard spectra using Waters Empower software. Standards for HPLC system calibration were obtained from Sigma (USA) and DHI (Denmark).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plantaginis Semen is commonly used in traditional medicine to treat edema, hypertension, and diabetes. The commercially available Plantaginis Semen in China mainly comes from three species. To clarify the chemical composition and distinct different species of Plantaginis Semen, we established a metabolite profiling method based on ultra high performance liquid chromatography with electrospray ionization quadrupole time-of-flight tandem mass spectrometry coupled with elevated energy technique. A total of 108 compounds, including phenylethanoid glycosides, flavonoids, guanidine derivatives, terpenoids, organic acids, and fatty acids, were identified from Plantago asiatica L., P. depressa Willd., and P. major L. Results showed significant differences in chemical components among the three species, particularly flavonoids. This study is the first to provide a comprehensive chemical profile of Plantaginis Semen, which could be involved into the quality control, medication guide, and developing new drug of Plantago seeds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the spectrum-effect relationships between high performance liquid chromatography (HPLC) fingerprints and duodenum contractility of charred areca nut (CAN) on rats. Methods: An HPLC method was used to establish the fingerprint of charred areca nut (CAN). The promoting effect on contractility of intestinal smooth was carried out to evaluate the duodenum contractility of CAN in vitro. In addition, the spectrum-effect relationships between HPLC fingerprints and bioactivities of CAN were investigated using multiple linear regression analysis (backward method). Results: Fourteen common peaks were detected and peak 3 (5-Hydroxymethyl-2-furfural, 5-HMF) was selected as the reference peak to calculate the relative retention time of 13 other common peaks. In addition, the equation of spectrum-effect relationships {Y = 3.818 - 1.126X1 + 0.817X2 - 0.045X4 - 0.504X5 + 0.728X6 - 0.056X8 + 1.122X9 - 0.247X13 - 0.978X14 (p < 0.05, R2 = 1)} was established in the present study by the multiple linear regression analysis (backward method). According to the equation, the absolute value of the coefficient before X1, X2, X4, X5, X6, X8, X9, X13, X14 was the coefficient between the component and the parameter. Conclusion: The model presented in this study successfully unraveled the spectrum-effect relationship of CAN, which provides a promising strategy for screening effective constituents of areca nut.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To develop an effective method for evaluating the quality of Cortex berberidis from different geographical origins. Methods: A simple, precise and accurate high performance liquid chromatography (HPLC) method was first developed for simultaneous quantification of four active alkaloids (magnoflorine, jatrorrhizine, palmatine, and berberine) in Cortex berberidis obtained from Qinghai, Tibet and Sichuan Provinces of China. Method validation was performed in terms of precision, repeatability, stability, accuracy, and linearity. Besides, partial least squares discriminant analysis (PLS-DA) and one-way analysis of variance (ANOVA) were applied to study the quality variations of Cortex berberidis from various geographical origins. Results: The proposed HPLC method showed good linearity, precision, repeatability, and accuracy. The four alkaloids were detected in all samples of Cortex berberidis. Among them, magnoflorine (36.46 - 87.30 mg/g) consistently showed the highest amounts in all the samples, followed by berberine (16.00 - 37.50 mg/g). The content varied in the range of 0.66 - 4.57 mg/g for palmatine and 1.53 - 16.26 mg/g for jatrorrhizine, respectively. The total content of the four alkaloids ranged from 67.62 to 114.79 mg/g. Moreover, the results obtained by the PLS-DA and ANOVA showed that magnoflorine level and the total content of these four alkaloids in Qinghai and Tibet samples were significantly higher (p < 0.01) than those in Sichuan samples. Conclusion: Quantification of multi-ingredients by HPLC combined with statistical methods provide an effective approach for achieving origin discrimination and quality evaluation of Cortex berberidis. The quality of Cortex berberidis closely correlates to the geographical origin of the samples, with Cortex berberidis samples from Qinghai and Tibet exhibiting superior qualities to those from Sichuan.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The drugs studied in this work have been reportedly used to commit drug-facilitated sexual assault (DFSA), commonly known as "date rape". Detection of the drugs was performed using high-performance liquid chromatography with ultraviolet detection (HPLC/UV) and identified with high performance-liquid chromatography mass spectrometry (HPLC/MS) using selected ion monitoring (SIM). The objective of this study was to develop a single HPLC method for the simultaneous detection, identification and quantitation of these drugs. The following drugs were simultaneously analyzed: Gamma-hydroxybutyrate (GHB), scopolamine, lysergic acid diethylamide, ketamine, flunitrazepam, and diphenhydramine. The results showed increased sensitivity with electrospray (ES) ionization versus atmospheric pressure chemical ionization (APCI) using HPLC/MS. HPLC/ES/MS was approximately six times more sensitive than HPLC/APCI/MS and about fifty times more sensitive than HPLC/UV. A limit of detection (LOD) of 100 ppb was achieved for drug analysis using this method. The average linear regression coefficient of correlation squared (r2) was 0.933 for HPLC/UV and 0.998 for HPLC/ES/MS. The detection limits achieved by this method allowed for the detection of drug dosages used in beverage tampering. This method can be used to screen beverages suspected of drug tampering. The results of this study demonstrated that solid phase microextraction (SPME) did not improve sensitivity as an extraction technique when compared to direct injections of the drug standards.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The diagnosis of tuberculosis is seriously hampered in the absence of standard biosafety laboratory facilities for specimen concentration and Mycobacterium tuberculosis culture. Within a laboratory twinning arrangement, heat-fixed direct smear and sediment from 74 bleach-processed and 20 non-processed specimens from Cumura Hospital, Guinea-Bissau, were sent to Lisbon for molecular evaluation of rifampicin resistance. Sequence analysis of a 369 base-pair ppoB locus detected 3.2% (3/94) resistant specimens. To our knowledge, this represents the first report on the molecular analysis of M. tuberculosis from bleach-processed sputum, an alternative to current diagnostic practice in low-resource settings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High performance liquid chromatographic (HPLC) and UV derivative spectrophotometric (UVDS) methods were developed and validated for the quantitative determination of sotalol hydrochloride in tablets. The HPLC method was performed on a C18 column with fluorescence detection. The excitation and emission wavelengths were 235 and 310nm, respectively. The mobile phase was composed of acetonitrile-water containing 0.1% trietylamine (7:93v/v) and pH adjusted to 4.6 with formic acid. The UVDS method was performed taking a signal at 239.1nm in the first derivative. The correlation coefficients (r) obtained were 0.9998 and 0.9997 for HPLC and UVDS methods, respectively. The proposed methods are simple and adaptable to routine analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Cardiac development is a complex and multifactorial biological process. Heterozygous mutations in the transcription factor NKX2.5 are between the first evidence of a genetic cause for congenital heart defects in human beings. In this study, we evaluated the presence and frequency of mutations in the NKX2.5 gene on 159 unrelated patients with a diverse range of non-syndromic congenital heart defects (conotruncal anomalies, septal defects, left-sided lesions, right-sided lesions, patent ductus arteriosus and Ebstein`s anomaly). Methods: The coding region of the NKX2.5 locus was amplified by polymerase chain reaction and mutational analysis was performed using denaturing high performance liquid chromatography (DHPLC) and DNA sequencing. Results: We identified two distinct mutations in the NKX2.5 coding region among the 159 (1.26%) individuals evaluated. An Arg25Cys mutation was identified in a patient with Tetralogy of Fallot. The second mutation found was an Ala42Pro in a patient with Ebstein`s anomaly. Conclusions: The association of NKX2.5 mutations is present in a small percentage of patients with non-syndromic congenital heart defects and may explain only a few cases of the disease. Screening strategies considering the identification of germ-line molecular defects in congenital heart disease are still unwarranted and should consider other genes besides NKX2.5. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To report the findings of the clinical and molecular evaluation in a Greek family with fleck corneal dystrophy (CFD).Methods: A 58-year-old woman was seen on routine ophthalmic examination and diagnosed as having CFD. All available family members were examined to evaluate the clinical findings and inheritance of the disease. Twenty members of the family in five generations underwent slit-lamp examination. Eleven were females and nine males, aged from two years to 85 years old. Blood samples were available from four patients with CFD and seven unaffected relatives, and the DNAs were subjected to molecular screening of the phosphoinositide kinase, five finger-containing (PIKFYVE) gene by direct sequencing or denaturing high performance liquid chromatography (DHPLC).Results: The clinical evaluation revealed six family members (five females and one male) with CFD. In two CFD patients early cataract formation was noticed. All patients affected with the corneal dystrophy were asymptomatic. The molecular analyses demonstrated the existence of a novel c. 3060-3063delCCTT (p.P968Vfs23) mutation in PIKFYVE in all CFD patients tested but in none of the six unaffected family members. No molecular screening was performed in the seventh unaffected member as the causative mutation was clearly transmitted from his affected wife to his affected son.Conclusions: We report on the clinical and molecular findings of a five generation Greek family with CFD and we conclude that the novel c. 3060-3063delCCTT (p. P968Vfs23) mutation in PIKFYVE, which segregated with the disease, was the causative mutation in this family.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Primary ciliary dyskinesia (PCD) is characterised by recurrent infections of the upper respiratory airways (nose, bronchi, and frontal sinuses) and randomisation of left-right body asymmetry. To date, PCD is mainly described with autosomal recessive inheritance and mutations have been found in five genes: the dynein arm protein subunits DNAI1, DNAH5 and DNAH11, the kinase TXNDC3, and the X-linked retinitis pigmentosa GTPase regulator RPGR. METHODS: We screened 89 unrelated individuals with PCD for mutations in the coding and splice site regions of the gene DNAH5 by denaturing high performance liquid chromatography (DHPLC) and sequencing. Patients were mainly of European origin and were recruited without any phenotypic preselection. RESULTS: We identified 18 novel (nonsense, splicing, small deletion and missense) and six previously described mutations. Interestingly, these DNAH5 mutations were mainly associated with outer + inner dyneins arm ultrastructural defects (50%). CONCLUSION: Overall, mutations on both alleles of DNAH5 were identified in 15% of our clinically heterogeneous cohort of patients. Although genetic alterations remain to be identified in most patients, DNAH5 is to date the main PCD gene.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A relatively simple, selective, precise and accurate high performance liquid chromatography (HPLC) method based on a reaction of phenylisothiocyanate (PITC) with glucosamine (GL) in alkaline media was developed and validated to determine glucosamine hydrochloride permeating through human skin in vitro. It is usually problematic to develop an accurate assay for chemicals traversing skin because the excellent barrier properties of the tissue ensure that only low amounts of the material pass through the membrane and skin components may leach out of the tissue to interfere with the analysis. In addition, in the case of glucosamine hydrochloride, chemical instability adds further complexity to assay development. The assay, utilising the PITC-GL reaction was refined by optimizing the reaction temperature, reaction time and PITC concentration. The reaction produces a phenylthiocarbarnyl-glucosamine (PTC-GL) adduct which was separated on a reverse-phase (RP) column packed with 5 mu m ODS (C-18) Hypersil particles using a diode array detector (DAD) at 245 nm. The mobile phase was methanol-water-glacial acetic acid (10:89.96:0.04 v/v/v, pH 3.5) delivered to the column at 1 ml min(-1) and the column temperature was maintained at 30 degrees C Using a saturated aqueous solution of glucosamine hydrochloride, in vitro permeation studies were performed at 32 +/- 1 degrees C over 48 h using human epidermal membranes prepared by a heat separation method and mounted in Franz-type diffusion cells with a diffusional area 2.15 +/- 0.1 cm(2). The optimum derivatisation reaction conditions for reaction temperature, reaction time and PITC concentration were found to be 80 degrees C, 30 min and 1 % v/v, respectively. PTC-Gal and GL adducts eluted at 8.9 and 9.7 min, respectively. The detector response was found to be linear in the concentration range 0-1000 mu g ml(-1). The assay was robust with intra- and inter-day precisions (described as a percentage of relative standard deviation, %R.S.D.) < 12. Intra- and inter-day accuracy (as a percentage of the relative error, %RE) was <=-5.60 and <=-8.00, respectively. Using this assay, it was found that GL-HCI permeates through human skin with a flux 1.497 +/- 0.42 mu g cm(-2) h(-1), a permeability coefficient of 5.66 +/- 1.6 x 10(-6) cm h(-1) and with a lag time of 10.9 +/- 4.6 h. (c) 2005 Elsevier B.V. All rights reserved.