957 resultados para Tubes dilution


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is no consensus regarding the accuracy of bioimpedance for the determination of body composition in older persons. This study aimed to compare the assessment of lean body mass of healthy older volunteers obtained by the deuterium dilution method (reference) with those obtained by two frequently used bioelectrical impedance formulas and one formula specifically developed for a Latin-American population. A cross-sectional study. Twenty one volunteers were studied, 12 women, with mean age 72 +/- 6.7 years. Urban community, Ribeiro Preto, Brazil. Fat free mass was determined, simultaneously, by the deuterium dilution method and bioelectrical impedance; results were compared. In bioelectrical impedance, body composition was calculated by the formulas of Deuremberg, Lukaski and Bolonchuck and Valencia et al. Lean body mass of the studied volunteers, as determined by bioelectrical impedance was 37.8 +/- 9.2 kg by the application of the Lukaski e Bolonchuk formula, 37.4 +/- 9.3 kg (Deuremberg) and 43.2 +/- 8.9 kg (Valencia et. al.). The results were significantly correlated to those obtained by the deuterium dilution method (41.6 +/- 9.3 Kg), with r=0.963, 0.932 and 0.971, respectively. Lean body mass obtained by the Valencia formula was the most accurate. In this study, lean body mass of older persons obtained by the bioelectrical impedance method showed good correlation with the values obtained by the deuterium dilution method. The formula of Valencia et al., developed for a Latin-American population, showed the best accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method for the determination of Ca, Cu, Fe, Mg, Mn, Se and Zn in bovine semen by quadrupole inductively coupled plasma spectrometry (q-ICP-MS) is described. Prior to analysis, samples (200 mu L) were diluted 1:50 in a solution containing 0.01% v/v Triton (R) X-100 and 0.5% v/v nitric acid and directly analyzed by ICP-MS. The limits of detection of the method are 0.3, 0.03, 0.2, 0.04, 0.04, 0.03 and 0.03 mu g L-1 for Ca-44, Cu-63, Fe-57, Mg-24, Zn-64, Se-82 and Mn-55, respectively. For purposes of comparison and method validation, four ordinary bovine semen samples were directly analyzed by ICP-MS and by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GF AAS), with no statistical difference between the techniques at the 95% level when applying the t-test. Then, the proposed method was applied in the determinations of Ca, Cu, Fe, Mg, Mn, Se and Zn in collected samples of bovine semen from different breeds, which are used in reproduction programs and artificial insemination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method for the determination of Ca, Cu, Fe, Mg, Mn, Se and Zn in bovine semen by quadrupole inductively coupled plasma spectrometry (q-ICP-MS) is described. Prior to analysis, samples (200 µL) were diluted 1:50 in a solution containing 0.01% v/v Triton® X-100 and 0.5% v/v nitric acid and directly analyzed by ICP-MS. The limits of detection of the method are 0.3, 0.03, 0.2, 0.04, 0.04, 0.03 and 0.03 µg L-1 for 44Ca, 63Cu, 57Fe, 24Mg, 64Zn, 82Se and 55Mn, respectively. For purposes of comparison and method validation, four ordinary bovine semen samples were directly analyzed by ICP-MS and by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GF AAS), with no statistical difference between the techniques at the 95% level when applying the t-test. Then, the proposed method was applied in the determinations of Ca, Cu, Fe, Mg, Mn, Se and Zn in collected samples of bovine semen from different breeds, which are used in reproduction programs and artificial insemination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the inhibitory activity of copaiba oil (Copaifera officinalis against the cariogenic microorganism, Streptococcus mutans. For such purpose, a minimum inhibition concentration test of copaiba oil against S. mutans was performed, using the serial dilution in broth technique, with a negative control, a positive control (0.12% chlorhexidine) and a 10% copaíba oil solution as a test. A minimum bactericidal concentration test with tubes presenting microbial inhibition was also conduced. In the minimum inhibitory concentration test, copaiba oil showed inhibition of bacterial growth at all concentrations tested up to 0.78 µL/mL of the 10% copaiba oil solution in the broth. In addition, the negative control had no inhibition, and the 0.12% chlorhexidine solution was effective up to 6.25 µL/mL in the broth. Copaiba oil showed a bacteriostatic activity against S. mutans at low concentrations, and could be a an option of phytotherapic agent to be used against cariogenic bacteria in the prevention of caries disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper shows theoretical models (analytical formulations) to predict the mechanical behavior of thick composite tubes and how some parameters can influence this behavior. Thus, firstly, it was developed the analytical formulations for a pressurized tube made of composite material with a single thick ply and only one lamination angle. For this case, the stress distribution and the displacement fields are investigated as function of different lamination angles and reinforcement volume fractions. The results obtained by the theoretical model are physic consistent and coherent with the literature information. After that, the previous formulations are extended in order to predict the mechanical behavior of a thick laminated tube. Both analytical formulations are implemented as a computational tool via Matlab code. The results obtained by the computational tool are compared to the finite element analyses, and the stress distribution is considered coherent. Moreover, the engineering computational tool is used to perform failure analysis, using different types of failure criteria, which identifies the damaged ply and the mode of failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the formation of self-assembled meso-tetrakis (p-sulfonatofenyl) porphyrin (H2 TPP'S POT. 4-''IND. 4') tubes stabilized by gold nanoparticles (NPs) in basic solution and on their spectroscopic chareterization. The role of the gold NPs in the aggregation dynamics of free-base sulfonated porphyrin (H2TPP'S POT. 4-''IND. 4') is also investigated. The direct conjugation of the gold NPs to the H2TPPS4 molecule quenches the fluorescence intensity, while absorption peaks are blue-shifted, indicating predominant H-type aggregation. It is observed that porphyrin molecules adsorbed on the surface of the gold NP interact and form tubes of maximum diameter ∼1.5 μm and length >100 μm. Steady-state and time-resolved spectroscopic techniques confirm nonradiative energy transfer from porphyrin to gold NP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Máster Oficial en Cultivos Marinos. VI Máster Internacional en Acuicultura. Trabajo presentado como requisito parcial para la obtención del Título de Máster Oficial en Cultivos Marinos, otorgado por la Universidad de Las Palmas de Gran Canaria (ULPGC), el Instituto Canario de Ciencias Marinas (ICCM), y el Centro Internacional de Altos Estudios Agronómicos Mediterráneos de Zaragoza (CIHEAM)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis the performances of the CMS Drift Tubes Local Trigger System of the CMS detector are studied. CMS is one of the general purpose experiments that will operate at the Large Hadron Collider at CERN. Results from data collected during the Cosmic Run At Four Tesla (CRAFT) commissioning exercise, a globally coordinated run period where the full experiment was involved and configured to detect cosmic rays crossing the CMS cavern, are presented. These include analyses on the precision and accuracy of the trigger reconstruction mechanism and measurement of the trigger efficiency. The description of a method to perform system synchronization is also reported, together with a comparison of the outcomes of trigger electronics and its software emulator code.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An accurate and sensitive species-specific GC-ICP-IDMS (gas chromatography inductively coupled plasma isotope dilution mass spectrometry) method for the determination of trimethyllead and a multi-species-specific GC-ICP-IDMS method for the simultaneous determination of trimethyllead, methylmercury, and butyltins in biological and environmental samples were developed. They allow the determination of corresponding elemental species down to the low ng g-1 range. The developed synthesis scheme for the formation of isotopically labeled Me3206Pb+ can be used for future production of this spike. The novel extraction technique, stir bar sorptive extraction (SBSE), was applied for the first time in connection with species-specific isotope dilution GC-ICP-MS for the determination of trimethyllead, methylmercury and butyltins. The results were compared with liquid-liquid extraction. The developed methods were validated by the analysis of certified reference materials. The liquid-liquid extraction GC-ICP-IDMS method was applied to seafood samples purchased from a supermarket. The methylated lead fraction in these samples, correlated to total lead, varied in a broad range of 0.01-7.6 %. On the contrary, the fraction of methylmercury is much higher, normally in the range of 80-98 %. The highest methylmercury content of up to 12 µg g-1 has been determined in shark samples, an animal which is at the end of the marine food chain, whereas in other seafood samples a MeHg+ content of less than 0.2 µg g-1 was found. Butyltin species could only be determined in samples, where anthropogenic contaminations must be assumed. This explains the observed broad variation of the butylated tin fraction in the range of <0.3-49 % in different seafood samples. Because all isotope-labelled spike compounds, except trimethyllead, are commercially available, the developed multi-species-specific GC-ICP-IDMS method has a high potential in future for routine analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Groundwater represents one of the most important resources of the world and it is essential to prevent its pollution and to consider remediation intervention in case of contamination. According to the scientific community the characterization and the management of the contaminated sites have to be performed in terms of contaminant fluxes and considering their spatial and temporal evolution. One of the most suitable approach to determine the spatial distribution of pollutant and to quantify contaminant fluxes in groundwater is using control panels. The determination of contaminant mass flux, requires measurement of contaminant concentration in the moving phase (water) and velocity/flux of the groundwater. In this Master Thesis a new solute flux mass measurement approach, based on an integrated control panel type methodology combined with the Finite Volume Point Dilution Method (FVPDM), for the monitoring of transient groundwater fluxes, is proposed. Moreover a new adsorption passive sampler, which allow to capture the variation of solute concentration with time, is designed. The present work contributes to the development of this approach on three key points. First, the ability of the FVPDM to monitor transient groundwater fluxes was verified during a step drawdown test at the experimental site of Hermalle Sous Argentau (Belgium). The results showed that this method can be used, with optimal results, to follow transient groundwater fluxes. Moreover, it resulted that performing FVPDM, in several piezometers, during a pumping test allows to determine the different flow rates and flow regimes that can occurs in the various parts of an aquifer. The second field test aiming to determine the representativity of a control panel for measuring mass flus in groundwater underlined that wrong evaluations of Darcy fluxes and discharge surfaces can determine an incorrect estimation of mass fluxes and that this technique has to be used with precaution. Thus, a detailed geological and hydrogeological characterization must be conducted, before applying this technique. Finally, the third outcome of this work concerned laboratory experiments. The test conducted on several type of adsorption material (Oasis HLB cartridge, TDS-ORGANOSORB 10 and TDS-ORGANOSORB 10-AA), in order to determine the optimum medium to dimension the passive sampler, highlighted the necessity to find a material with a reversible adsorption tendency to completely satisfy the request of the new passive sampling technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'obiettivo di questo lavoro è quello di analizzare la stabilità di uno spettro raggi X emesso da un tubo usurato per analisi cardiovascolari, in modo da verificare il suo comportamento. Successivamente questo tipo di analisi sarà effettuata su tubi CT. Per raggiungere questo scopo è stato assemblato un particolare set-up con un rivelatore al germanio criogenico in modo da avere la miglior risoluzione energetica possibile ed alcuni particolari collimatori così da ridurre il flusso fotonico per evitare effetti di pile-up. Il set-up è stato costruito in modo da avere il miglior allineamento possibile nel modo più veloce possibile, e con l'obiettivo di rendere l'intero sistema portabile. Il tubo usato è un SRM Philips tube per analisi cardiovascolari; questa scelta è stata fatta in modo da ridurre al minimo i fattori esterni (ottica elettromagnetica, emettitori) e concentrare l'attenzione solo sugli effetti, causati dalle varie esposizioni, sull'anodo (roughness e bending) e sul comportamento di essi durante il surriscaldamento e successivo raffreddamento del tubo. I risultati mostrano come durante un'esposizione alcuni fattori di usura del tubo possono influire in maniera sostanziale sullo spettro ottenuto e quindi alterare il risultato. Successivamente, nell'elaborato, mediante il software Philips di ricostruzione e simulazione dello spettro si è cercato di riprodurre, variando alcuni parametri, la differenza riscontrata sperimentalmente in modo da poter simulare l'instabilità e correggere i fattori che la causano. I risultati sono interessanti non solo per questo esperimento ma anche in ottica futura, per lo sviluppo di applicazioni come la spectral CT. Il passo successivo sarà quello di spostare l'attenzione su un CT tube e verificare se l'instabilità riscontrata in questo lavoro è persiste anche in una analisi più complessa come quella CT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the utility of nasotracheal tubes in postoperative oxygen supplementation in dogs following corrective surgery for brachycephalic syndrome. DESIGN: Retrospective study 2003-2007. SETTING: University teaching hospital. ANIMALS: Thirty-six client-owned dogs that underwent corrective surgery for brachycephalic syndrome. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Medical records were reviewed for animals that underwent surgical interventions for brachycephalic syndrome including palatoplasty, ventriculectomy, and rhinoplasty. Data collected included signalment, presenting complaints, analgesic and surgical interventions, type of supplemental oxygen therapy, complications and mortality occurring during hospitalization. A nasotracheal tube (NTT) was placed in 20 dogs at the end of surgery; 16 dogs received other forms of oxygen supplementation (8) or no oxygen supplementation (8) during recovery. The total number of postoperative complications was similar in both groups (8/20 dogs with NTTs and 7/16 in those without NTTs). However, respiratory distress was observed in 5 dogs without NTTs but was not observed in any dog while an NTT was in place. One dog in each group died postoperatively. CONCLUSION: Placement of an NTT was found to be easy and may offer benefit in dogs with brachycephalic syndrome as a noninvasive means of delivering oxygen. The use of NTT may minimize severe postoperative morbidity, in particular by reducing postoperative respiratory distress.