954 resultados para Test reliability


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The concept of palliative care consisting of five distinct, clinically meaningful, phases (stable, unstable, deteriorating, terminal and bereavement) was developed in Australia about 20 years ago and is used routinely for communicating clinical status, care planning, quality improvement and funding. Aim: To test the reliability and acceptability of revised definitions of Palliative Care Phase. Design: Multi-centre cross-sectional study involving pairs of clinicians independently rating patients according to revised definitions of Palliative Care Phase. Setting/participants: Clinicians from 10 Australian palliative care services, including 9 inpatient units and 1 mixed inpatient/community-based service. Results: A total of 102 nursing and medical clinicians participated, undertaking 595 paired assessments of 410 patients, of which 90.7% occurred within 2 h. Clinicians rated 54.8% of patients in the stable phase, 15.8% in the unstable phase, 20.8% in the deteriorating phase and 8.7% in the terminal phase. Overall agreement between clinicians’ rating of Palliative Care Phase was substantial (kappa = 0.67; 95% confidence interval = 0.61–0.70). A moderate level of inter-rater reliability was apparent across all participating sites. The results indicated that Palliative Care Phase was an acceptable measure, with no significant difficulties assigning patients to a Palliative Care Phase and a good fit between assessment of phase and the definition of that phase. The most difficult phase to distinguish from other phases was the deteriorating phase. Conclusion: Policy makers, funders and clinicians can be confident that Palliative Care Phase is a reliable and acceptable measure that can be used for care planning, quality improvement and funding purposes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE The purposes of this study were to: 1) establish inter-instrument reliability between left and right hip accelerometer placement; 2) examine procedural reliability of a walking protocol used to measure physical activity (PA), and; 3) confirm concurrent validity of accelerometers in measuring PA intensity as compared to the gold standard of oxygen consumption measured by indirect calorimetry. METHODS Eight children (mean age: 11.9; SD: 3.2, 75% male) with CP (GMFCS levels I-III) wore ActiGraph GT3X accelerometers on each hip and the Cosmed K4b^{2} portable indirect calorimeter during two measurement sessions in which they performed the six minute walk test (6MWT) at three self-selected speeds (comfortable/slow, brisk, fast). Oxygen consumption (VO2) and accelerometer step and activity count data were recorded. RESULTS Inter-instrument reliability of ActiGraph GT3X accelerometers placed on left and right hips was excellent (ICC=0.96-0.99, CI_{95}: 0.81-0.99). Reproducibility of the protocol was good/excellent (ICC=0.75-0.95, CI_{95}: 0.75-0.98). Concurrent validity of accelerometer count data and VO2 was fair/good (rho=0.67, p< 0.001). The correlation between step count and VO2 was not significant (rho=0.29, p=0.2). CONCLUSION This preliminary research suggests that ActiGraph GT3X accelerometers are reliable and valid devices to monitor PA during walking in children with CP and may be appropriate in rehabilitation research and clinical practice. ActiGraph GTX3 step counts were not valid for this sample and further research is warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The Spine Functional Index (SFI) is a patient reported outcome measure with sound clinimetric properties and clinical viability for the determination of whole-spine impairment. To date, no validated Turkish version is available. The purpose of this study is to cross-culturally adapted the SFI for Turkish-speaking patients (SFI-Tk) and determine the psychometric properties of reliability, validity and factor structure in a Turkish population with spine musculoskeletal disorders. Methods The SFI English version was culturally adapted and translated into Turkish using a double forward and backward method according to established guidelines. Patients (n = 285, cervical = l29, lumbar = 151, cervical and lumbar region = 5, 73% female, age 45 ± 1) with spine musculoskeletal disorders completed the SFI-Tk at baseline and after a seven day period for test-retest reliability. For criterion validity the Turkish version of the Functional Rating Index (FRI) was used plus the Neck Disability Index (NDI) for cervical patients and the Oswestry Disability Index (ODI) for back patients. Additional psychometric properties were determined for internal consistency (Chronbach’s α), criterion validity and factor structure. Results There was a high degree of internal consistency (α = 0.85, item range 0.80-0.88) and test-retest reliability (r = 0.93, item range = 0.75-0.95). The factor analysis demonstrated a one-factor solution explaining 24.2% of total variance. Criterion validity with the ODI was high (r = 0.71, p < 0.001) while the FRI and NDI were fair (r = 0.52 and r = 0.58, respectively). The SFI-Tk showed no missing responses with the ‘half-mark’ option used in 11.75% of total responses by 77.9% of participants. Measurement error from SEM and MDC90 were respectively 2.96% and 7.12%. Conclusions The SFI-Tk demonstrated a one-factor solution and is a reliable and valid instrument. The SFI-Tk consists of simple and easily understood wording and may be used to assess spine region musculoskeletal disorders in Turkish speaking patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Balance dysfunction is one of the most common problems in people who suffer stroke. To parameterize functional tests standardized by inertial sensors have been promoted in applied medicine. The aim of this study was to compare the kinematic variables of the Functional Reach Test (FRT) obtained by two inertial sensors placed on the trunk and lumbar region between stroke survivors (SS) and healthy older adults (HOA) and to analyze the reliability of the kinematic measurements obtained. Methods Cross-sectional study. Five SS and five HOA over 65. A descriptive analysis of the average range as well as all kinematic variables recorded was developed. The intrasubject and intersubject reliability of the measured variables was directly calculated. Results In the same intervals, the angular displacement was greater in the HOA group; however, they were completed at similar times for both groups, and HOA conducted the test at a higher speed and greater acceleration in each of the intervals. The SS values were higher than HOA values in the maximum and minimum acceleration in the trunk and in the lumbar region. Conclusions The SS show less functional reach, a narrower, slower and less accelerated movement during the FRT execution, but with higher peaks of acceleration and speed when they are compared with HOA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background In the emergency department, portable point-of-care testing (POCT) coagulation devices may facilitate stroke patient care by providing rapid International Normalized Ratio (INR) measurement. The objective of this study was to evaluate the reliability, validity, and impact on clinical decision-making of a POCT device for INR testing in the setting of acute ischemic stroke (AIS). Methods A total of 150 patients (50 healthy volunteers, 51 anticoagulated patients, 49 AIS patients) were assessed in a tertiary care facility. The INR's were measured using the Roche Coaguchek S and the standard laboratory technique. Results The interclass correlation coefficient and 95% confidence interval between overall POCT device and standard laboratory value INRs was high (0.932 (0.69 - 0.78). In the AIS group alone, the correlation coefficient and 95% CI was also high 0.937 (0.59 - 0.74) and diagnostic accuracy of the POCT device was 94%. Conclusions When used by a trained health professional in the emergency department to assess INR in acute ischemic stroke patients, the CoaguChek S is reliable and provides rapid results. However, as concordance with laboratory INR values decreases with higher INR values, it is recommended that with CoaguChek S INRs in the > 1.5 range, a standard laboratory measurement be used to confirm the results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Evaluation of scapular posture is an integral component of the clinical assessment of painful neck disorders. The aim of this study was to evaluate agreement between therapist judgements of scapula posture in multiple biomechanical planes in individuals with neck pain. Design Inter-therapist reliability study. Setting Research laboratory. Participants Fifteen participants with chronic neck pain. Main outcome measures Four physiotherapists recorded ratings of scapular orientation (relative to the thorax) in five different scapula postural planes (plane of scapula, sagittal plane, transverse plane, horizontal plane, and vertical plane) under four test conditions (at rest, and during three isometric shoulder conditions) in all participants. Inter-therapist reliability was expressed using both generalized and paired kappa coefficient. Results Following adjustment for expected agreement and the high prevalence of neutral ratings (81%), on average both the generalised kappa (0.37) as well as Cohen's Kappa for the two therapist pairs (0.45 and 0.42) demonstrated only slight to moderate inter-therapist reliability. Conclusions The findings suggest that ratings of scapular posture in individuals with neck pain by visual inspection has only slight to moderate reliability and should only be used in conjunction with other clinical tests when judging scapula function in these patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background The Palliative Care Problem Severity Score is a clinician-rated tool to assess problem severity in four palliative care domains (pain, other symptoms, psychological/spiritual, family/carer problems) using a 4-point categorical scale (absent, mild, moderate, severe). Aim To test the reliability and acceptability of the Palliative Care Problem Severity Score. Design: Multi-centre, cross-sectional study involving pairs of clinicians independently rating problem severity using the tool. Setting/participants Clinicians from 10 Australian palliative care services: 9 inpatient units and 1 mixed inpatient/community-based service. Results A total of 102 clinicians participated, with almost 600 paired assessments completed for each domain, involving 420 patients. A total of 91% of paired assessments were undertaken within 2 h. Strength of agreement for three of the four domains was moderate: pain (Kappa = 0.42, 95% confidence interval = 0.36 to 0.49); psychological/spiritual (Kappa = 0.48, 95% confidence interval = 0.42 to 0.54); family/carer (Kappa = 0.45, 95% confidence interval = 0.40 to 0.52). Strength of agreement for the remaining domain (other symptoms) was fair (Kappa = 0.38, 95% confidence interval = 0.32 to 0.45). Conclusion The Palliative Care Problem Severity Score is an acceptable measure, with moderate reliability across three domains. Variability in inter-rater reliability across sites and participant feedback indicate that ongoing education is required to ensure that clinicians understand the purpose of the tool and each of its domains. Raters familiar with the patient they were assessing found it easier to assign problem severity, but this did not improve inter-rater reliability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Multiple sclerosis (MS) is a chronic, inflammatory disease of the central nervous system, characterized especially by myelin and axon damage. Cognitive impairment in MS is common but difficult to detect without a neuropsychological examination. Valid and reliable methods are needed in clinical practice and research to detect deficits, follow their natural evolution, and verify treatment effects. The Paced Auditory Serial Addition Test (PASAT) is a measure of sustained and divided attention, working memory, and information processing speed, and it is widely used in MS patients neuropsychological evaluation. Additionally, the PASAT is the sole cognitive measure in an assessment tool primarly designed for MS clinical trials, the Multiple Sclerosis Functional Composite (MSFC). The aims of the present study were to determine a) the frequency, characteristics, and evolution of cognitive impairment among relapsing-remitting MS patients, and b) the validity and reliability of the PASAT in measuring cognitive performance in MS patients. The subjects were 45 relapsing-remitting MS patients from Seinäjoki Central Hospital, Department of Neurology and 48 healthy controls. Both groups underwent comprehensive neuropsychological assessments, including the PASAT, twice in a one-year follow-up, and additionally a sample of 10 patients and controls were evaluated with the PASAT in serial assessments five times in one month. The frequency of cognitive dysfunction among relapsing-remitting MS patients in the present study was 42%. Impairments were characterized especially by slowed information processing speed and memory deficits. During the one-year follow-up, the cognitive performance was relatively stable among MS patients on a group level. However, the practice effects in cognitive tests were less pronounced among MS patients than healthy controls. At an individual level the spectrum of MS patients cognitive deficits was wide in regards to their characteristics, severity, and evolution. The PASAT was moderately accurate in detecting MS-associated cognitive impairment, and 69% of patients were correctly classified as cognitively impaired or unimpaired when comprehensive neuropsychological assessment was used as a "gold standard". Self-reported nervousness and poor arithmetical skills seemed to explain misclassifications. MS-related fatigue was objectively demonstrated as fading performance towards the end of the test. Despite the observed practice effect, the reliability of the PASAT was excellent, and it was sensitive to the cognitive decline taking place during the follow-up in a subgroup of patients. The PASAT can be recommended for use in the neuropsychological assessment of MS patients. The test is fairly sensitive, but less specific; consequently, the reasons for low scores have to be carefully identified before interpreting them as clinically significant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

- Objectives To develop and test a valid and reliable assessment of wheelchair skills for individuals with spinal cord injuries (SCI); the Queensland Evaluation of Wheelchair Skills (QEWS). - Setting Hospital, Australia. - Methods Phase 1: Four Delphi panel rounds with clinical experts were used to develop the QEWS. Phase 2: Intra-rater and inter-rater reliability of the QEWS items were examined in 100 people with SCI. Phase 3a: Concurrent validity was investigated by examining the association between QEWS total scores and physiotherapists’ global ratings of wheelchair skill performance. Phase 3b: Construct validity was tested in 20 people with recent SCI by examining change in QEWS total scores between when they first mobilised in a wheelchair and scores obtained 10 weeks later. - Results Phase 1: The QEWS was developed. Phase 2: The intra-class correlation coefficients reflecting the intra-rater reliability and the inter-rater reliability for the QEWS total score were 1.00 and 0.98, with scores being within one point of each other 96 and 91% of the time, respectively. Phase 3a: The QEWS total scores were comparable with the global rating of wheelchair skill performance (r2=0.93). Phase 3b: The QEWS scores changed by a median (interquartile range (IQR)) of 4 (1 to 6) points over the 10-week period following first wheelchair mobilisation. - Conclusion The QEWS is a valid and reliable tool for measuring wheelchair skills in individuals with SCI. The QEWS is efficient and practical to administer and does not require specialised equipment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To develop the DCDDaily, an instrument for objective and standardized clinical assessment of capacity in activities of daily living (ADL) in children with developmental coordination disorder (DCD), and to investigate its usability, reliability, and validity. Subjects Five to eight-year-old children with and without DCD. Main measures The DCDDaily was developed based on thorough review of the literature and extensive expert involvement. To investigate the usability (assessment time and feasibility), reliability (internal consistency and repeatability), and validity (concurrent and discriminant validity) of the DCDDaily, children were assessed with the DCDDaily and the Movement Assessment Battery for Children-2 Test, and their parents filled in the Movement Assessment Battery for Children-2 Checklist and Developmental Coordination Disorder Questionnaire. Results 459 children were assessed (DCD group, n = 55; normative reference group, n = 404). Assessment was possible within 30 minutes and in any clinical setting. For internal consistency, Cronbach’s α = 0.83. Intraclass correlation = 0.87 for test–retest reliability and 0.89 for inter-rater reliability. Concurrent correlations with Movement Assessment Battery for Children-2 Test and questionnaires were ρ = −0.494, 0.239, and −0.284, p < 0.001. Discriminant validity measures showed significantly worse performance in the DCD group than in the control group (mean (SD) score 33 (5.6) versus 26 (4.3), p < 0.001). The area under curve characteristic = 0.872, sensitivity and specificity were 80%. Conclusions The DCDDaily is a valid and reliable instrument for clinical assessment of capacity in ADL, that is feasible for use in clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the foremost design considerations in microelectronics miniaturization is the use of embedded passives which provide practical solution. In a typical circuit, over 80 percent of the electronic components are passives such as resistors, inductors, and capacitors that could take up to almost 50 percent of the entire printed circuit board area. By integrating passive components within the substrate instead of being on the surface, embedded passives reduce the system real estate, eliminate the need for discrete and assembly, enhance electrical performance and reliability, and potentially reduce the overall cost. Moreover, it is lead free. Even with these advantages, embedded passive technology is at a relatively immature stage and more characterization and optimization are needed for practical applications leading to its commercialization.This paper presents an entire process from design and fabrication to electrical characterization and reliability test of embedded passives on multilayered microvia organic substrate. Two test vehicles focusing on resistors and capacitors have been designed and fabricated. Embedded capacitors in this study are made with polymer/ceramic nanocomposite (BaTiO3) material to take advantage of low processing temperature of polymers and relatively high dielectric constant of ceramics and the values of these capacitors range from 50 pF to 1.5 nF with capacitance per area of approximately 1.5 nF/cm(2). Limited high frequency measurement of these capacitors was performed. Furthermore, reliability assessments of thermal shock and temperature humidity tests based on JEDEC standards were carried out. Resistors used in this work have been of three types: 1) carbon ink based polymer thick film (PTF), 2) resistor foils with known sheet resistivities which are laminated to printed wiring board (PWB) during a sequential build-up (SBU) process and 3) thin-film resistor plating by electroless method. Realization of embedded resistors on conventional board-level high-loss epoxy (similar to 0.015 at 1 GHz) and proposed low-loss BCB dielectric (similar to 0.0008 at > 40 GHz) has been explored in this study. Ni-P and Ni-W-P alloys were plated using conventional electroless plating, and NiCr and NiCrAlSi foils were used for the foil transfer process. For the first time, Benzocyclobutene (BCB) has been proposed as a board level dielectric for advanced System-on-Package (SOP) module primarily due to its attractive low-loss (for RF application) and thin film (for high density wiring) properties.Although embedded passives are more reliable by eliminating solder joint interconnects, they also introduce other concerns such as cracks, delamination and component instability. More layers may be needed to accommodate the embedded passives, and various materials within the substrate may cause significant thermo -mechanical stress due to coefficient of thermal expansion (CTE) mismatch. In this work, numerical models of embedded capacitors have been developed to qualitatively examine the effects of process conditions and electrical performance due to thermo-mechanical deformations.Also, a prototype working product with the board level design including features of embedded resistors and capacitors are underway. Preliminary results of these are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vegetation maps and bioclimatic zone classifications communicate the vegetation of an area and are used to explain how the environment regulates the occurrence of plants on large scales. Many practises and methods for dividing the world’s vegetation into smaller entities have been presented. Climatic parameters, floristic characteristics, or edaphic features have been relied upon as decisive factors, and plant species have been used as indicators for vegetation types or zones. Systems depicting vegetation patterns that mainly reflect climatic variation are termed ‘bioclimatic’ vegetation maps. Based on these it has been judged logical to deduce that plants moved between corresponding bioclimatic areas should thrive in the target location, whereas plants moved from a different zone should languish. This principle is routinely applied in forestry and horticulture but actual tests of the validity of bioclimatic maps in this sense seem scanty. In this study I tested the Finnish bioclimatic vegetation zone system (BZS). Relying on the plant collection of Helsinki University Botanic Garden’s Kumpula collection, which according to the BZS is situated at the northern limit of the hemiboreal zone, I aimed to test how the plants’ survival depends on their provenance. My expectation was that plants from the hemiboreal or southern boreal zones should do best in Kumpula, whereas plants from more southern and more northern zones should show progressively lower survival probabilities. I estimated probability of survival using collection database information of plant accessions of known wild origin grown in Kumpula since the mid 1990s, and logistic regression models. The total number of accessions I included in the analyses was 494. Because of problems with some accessions I chose to separately analyse a subset of the complete data, which included 379 accessions. I also analysed different growth forms separately in order to identify differences in probability of survival due to different life strategies. In most analyses accessions of temperate and hemiarctic origin showed lower survival probability than those originating from any of the boreal subzones, which among them exhibited rather evenly high probabilities. Exceptionally mild and wet winters during the study period may have killed off hemiarctic plants. Some winters may have been too harsh for temperate accessions. Trees behaved differently: they showed an almost steadily increasing survival probability from temperate to northern boreal origins. Various factors that could not be controlled for may have affected the results, some of which were difficult to interpret. This was the case in particular with herbs, for which the reliability of the analysis suffered because of difficulties in managing their curatorial data. In all, the results gave some support to the BZS, and especially its hierarchical zonation. However, I question the validity of the formulation of the hypothesis I tested since it may not be entirely justified by the BZS, which was designed for intercontinental comparison of vegetation zones, but not specifically for transcontinental provenance trials. I conclude that botanic gardens should pay due attention to information management and curational practices to ensure the widest possible applicability of their plant collections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article presents frequentist inference of accelerated life test data of series systems with independent log-normal component lifetimes. The means of the component log-lifetimes are assumed to depend on the stress variables through a linear stress translation function that can accommodate the standard stress translation functions in the literature. An expectation-maximization algorithm is developed to obtain the maximum likelihood estimates of model parameters. The maximum likelihood estimates are then further refined by bootstrap, which is also used to infer about the component and system reliability metrics at usage stresses. The developed methodology is illustrated by analyzing a real as well as a simulated dataset. A simulation study is also carried out to judge the effectiveness of the bootstrap. It is found that in this model, application of bootstrap results in significant improvement over the simple maximum likelihood estimates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study addresses the problem of obtaining reliable velocities and displacements from accelerograms, a concern which often arises in earthquake engineering. A closed-form acceleration expression with random parameters is developed to test any strong-motion accelerogram processing method. Integration of this analytical time history yields the exact velocities, displacements and Fourier spectra. Noise and truncation can also be added. A two-step testing procedure is proposed and the original Volume II routine is used as an illustration. The main sources of error are identified and discussed. Although these errors may be reduced, it is impossible to extract the true time histories from an analog or digital accelerogram because of the uncertain noise level and missing data. Based on these uncertainties, a probabilistic approach is proposed as a new accelerogram processing method. A most probable record is presented as well as a reliability interval which reflects the level of error-uncertainty introduced by the recording and digitization process. The data is processed in the frequency domain, under assumptions governing either the initial value or the temporal mean of the time histories. This new processing approach is tested on synthetic records. It induces little error and the digitization noise is adequately bounded. Filtering is intended to be kept to a minimum and two optimal error-reduction methods are proposed. The "noise filters" reduce the noise level at each harmonic of the spectrum as a function of the signal-to-noise ratio. However, the correction at low frequencies is not sufficient to significantly reduce the drifts in the integrated time histories. The "spectral substitution method" uses optimization techniques to fit spectral models of near-field, far-field or structural motions to the amplitude spectrum of the measured data. The extremes of the spectrum of the recorded data where noise and error prevail are then partly altered, but not removed, and statistical criteria provide the choice of the appropriate cutoff frequencies. This correction method has been applied to existing strong-motion far-field, near-field and structural data with promising results. Since this correction method maintains the whole frequency range of the record, it should prove to be very useful in studying the long-period dynamics of local geology and structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Timing-related defects are major contributors to test escapes and in-field reliability problems for very-deep submicrometer integrated circuits. Small delay variations induced by crosstalk, process variations, power-supply noise, as well as resistive opens and shorts can potentially cause timing failures in a design, thereby leading to quality and reliability concerns. We present a test-grading technique that uses the method of output deviations for screening small-delay defects (SDDs). A new gate-delay defect probability measure is defined to model delay variations for nanometer technologies. The proposed technique intelligently selects the best set of patterns for SDD detection from an n-detect pattern set generated using timing-unaware automatic test-pattern generation (ATPG). It offers significantly lower computational complexity and excites a larger number of long paths compared to a current generation commercial timing-aware ATPG tool. Our results also show that, for the same pattern count, the selected patterns provide more effective coverage ramp-up than timing-aware ATPG and a recent pattern-selection method for random SDDs potentially caused by resistive shorts, resistive opens, and process variations. © 2010 IEEE.