847 resultados para Ocular Microtremor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To estimate the relationships between ocular parameters and tonometrically measured intraocular pressure (IOP), to determine the influence of ocular parameters on different instrument measurements of IOP, and to evaluate the association of ocular parameters with a parameter called hysteresis. METHODS: Patients presenting at a glaucoma clinic were recruited for this study. Subjects underwent IOP measurement with the Goldmann applanation tonometer (GAT), the TonoPen, and the Reichert Ocular Response Analyzer (ORA), and also measurements of central corneal thickness (CCT), axial length, corneal curvature, corneal astigmatism, central visual acuity, and refractive error. Chart information was reviewed to determine glaucoma treatment history. The ORA instrument provided a measurement called corneal hysteresis. The association between measured IOP and the other ocular characteristics was estimated using generalized estimating equations. RESULTS: Among 230 patients, IOP measurements from the TonoPen read lowest, and ORA read highest, and GAT measurements were closest to the mean IOP of the 3 instruments. In a multiple regression model adjusting for age, sex, race, and other ocular characteristics, a 10 microm increase in CCT was associated with an increase of 0.79 mm Hg measured IOP in untreated eyes (P<0.0001). Of the 3 tonometers, GAT was the least affected by CCT (0.66 mm Hg/10 mum, P<0.0001). Hysteresis was significantly correlated with CCT with a modest correlation coefficient (r=0.20, P<0.0007). CONCLUSIONS: Among parameters related to measured IOP, features in addition to CCT, such as hysteresis and corneal curvature, may also be important. Tonometric instruments seem to be affected differently by various physiologic characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the effectiveness of diode laser trans-scleral cyclophotocoagulation (TSCPC) on intraocular pressure (IOP) in nine patients having raised IOP following use of silicone oil (SO) for retinal detachment (RD) surgery in a retrospective observational case series. Diode laser TSCPC was applied at a power setting of 1.75 to 2.5 watts, for two sec with a maximum of 30 applications. The patients were followed up for 40 to 312 weeks. The mean pre-laser IOP was 32.06 mm Hg (SD 7.32). The mean post-laser IOP at one month, three months and six months was 17.89 mm Hg (SD 8.23), 21.89 mm Hg (SD 8.16) and 21.67 mm Hg (SD 7.55) respectively. The final IOP (at the last follow-up) was 19.56 mm Hg (SD 7.85) (P=0.021). Seven of them had undergone SO removal. In our observation, effectiveness of TSCPC in long-term control of SO-induced ocular hypertension was limited as compared to short-term control of IOP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the agreement between optical low-coherence reflectometry (OLCR) and anterior segment optical coherence tomography (AS-OCT) for biometry of the anterior segment. SETTING: State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China. DESIGN: Evaluation of diagnostic technology. METHODS: A series of OLCR (Lenstar LS 900) and AS-OCT measurements of the anterior segment were taken for consecutive subjects aged 35 years and older in a population-based study. The differences and correlations between the 2 methods of ocular biometry were assessed. Agreement was calculated as the 95% limits of agreement (LoA). RESULTS: The mean age of the 776 subjects was 55.2 years ± 12.0 (SD); 54.6% were women. The mean central corneal thickness (CCT) was smaller with OLCR than with AS-OCT (537.84 ± 31.46 μm versus 559.39 ± 32.02 μm) as was anterior chamber depth (ACD) (2.60 ± 0.37 mm versus 2.72 ± 0.37 mm) and anterior chamber width (ACW) (11.76 ± 0.47 mm versus 12.04 ± 0.55 mm) (all P<.001). The 95% LoA between the 2 instruments were -44.80 to 1.71 μm for CCT, -0.17 to -0.06 mm for ACD, and -1.28 to 0.72 mm for ACW. CONCLUSION: Optical low-coherence reflectometry and AS-OCT yielded potentially interchangeable ACD measurements, while the CCT and ACW measurements acquired by the 2 devices showed clinically significant differences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retinal angiogenesis is tightly regulated to meet oxygenation and nutritional requirements. In diseases such as proliferative diabetic retinopathy and neovascular age-related macular degeneration, uncontrolled angiogenesis can lead to blindness. Our goal is to better understand the molecular processes controlling retinal angiogenesis and discover novel drugs that inhibit retinal neovascularization. Phenotype-based chemical screens were performed using the ChemBridge DiversetTM library and inhibition of hyaloid vessel angiogenesis in Tg(fli1:EGFP) zebrafish. 2-[(E)-2-(Quinolin-2-yl)vinyl]phenol, (quininib) robustly inhibits developmental angiogenesis at 4–10 μM in zebrafish and significantly inhibits angiogenic tubule formation in HMEC-1 cells, angiogenic sprouting in aortic ring explants, and retinal revascularization in oxygen-induced retinopathy mice. Quininib is well tolerated in zebrafish, human cell lines, and murine eyes. Profiling screens of 153 angiogenic and inflammatory targets revealed that quininib does not directly target VEGF receptors but antagonizes cysteinyl leukotriene receptors 1 and 2 (CysLT1–2) at micromolar IC50 values. In summary, quininib is a novel anti-angiogenic small-molecule CysLT receptor antagonist. Quininib inhibits angiogenesis in a range of cell and tissue systems, revealing novel physiological roles for CysLT signaling. Quininib has potential as a novel therapeutic agent to treat ocular neovascular pathologies and may complement current anti-VEGF biological agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the efficiency of alternative monitoring services for people with ocular hypertension (OHT), a glaucoma risk factor.

DESIGN: Discrete event simulation model comparing five alternative care pathways: treatment at OHT diagnosis with minimal monitoring; biennial monitoring (primary and secondary care) with treatment if baseline predicted 5-year glaucoma risk is ≥6%; monitoring and treatment aligned to National Institute for Health and Care Excellence (NICE) glaucoma guidance (conservative and intensive).

SETTING: UK health services perspective.

PARTICIPANTS: Simulated cohort of 10 000 adults with OHT (mean intraocular pressure (IOP) 24.9 mm Hg (SD 2.4).

MAIN OUTCOME MEASURES: Costs, glaucoma detected, quality-adjusted life years (QALYs).

RESULTS: Treating at diagnosis was the least costly and least effective in avoiding glaucoma and progression. Intensive monitoring following NICE guidance was the most costly and effective. However, considering a wider cost-utility perspective, biennial monitoring was less costly and provided more QALYs than NICE pathways, but was unlikely to be cost-effective compared with treating at diagnosis (£86 717 per additional QALY gained). The findings were robust to risk thresholds for initiating monitoring but were sensitive to treatment threshold, National Health Service costs and treatment adherence.

CONCLUSIONS: For confirmed OHT, glaucoma monitoring more frequently than every 2 years is unlikely to be efficient. Primary treatment and minimal monitoring (assessing treatment responsiveness (IOP)) could be considered; however, further data to refine glaucoma risk prediction models and value patient preferences for treatment are needed. Consideration to innovative and affordable service redesign focused on treatment responsiveness rather than more glaucoma testing is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypothesis: As the anterior and posterior semicircular canals are vital to the regulation of gaze stability, particularly during locomotion or vehicular travel, we tested whether the high velocity vestibulo‐ocular reflex (VOR) of the three ipsilesional semicircular canals elicited by the modified Head Impulse Test would correlate with subjective dizziness or vertigo scores after vestibular neuritis (VN). Background: Recovery following acute VN varies with around half reporting persistent symptoms long after the acute episode. However, an unanswered question is whether chronic symptoms are associated with impairment of the high velocity VOR of the anterior or posterior canals. Methods: Twenty patients who had experienced an acute episode of VN at least three months earlier were included in this study. Participants were assessed with the video head impulse test (vHIT) of all six canals, bithermal caloric irrigation, the Dizziness Handicap Inventory (DHI) and the Vertigo Symptoms Scale short‐form (VSS). Results: Of these 20 patients, 12 felt that they had recovered from the initial episode whereas 8 did not and reported elevated DHI and VSS scores. However, we found no correlation between DHI or VSS scores and the ipsilesional single or combined vHIT gain, vHIT gain asymmetry or caloric paresis. The high velocity VOR was not different between patients who felt they had recovered and patients who felt they had not. Conclusions: Our findings suggest that chronic symptoms of dizziness following VN are not associated with the high velocity VOR of the single or combined ipsilesional horizontal, anterior or posterior semicircular canals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The present study investigated whether prochlorperazine affects vestibular-ocular reflex (VOR) and vestibulo-perceptual function. Methods: We studied 12 healthy naïve subjects 3 hours after a single dose of oral prochlorperazine 5mg in a randomised, placebo-controlled, double-blind, cross-over study in healthy young subjects. Two rotational tests in yaw were used: 1) a Threshold task investigating perceptual motion detection and nystagmic thresholds (acceleration steps of 0.5deg/s/s) and 2) Suprathreshold responses to velocity steps of 90deg/s in which vestibulo-ocular (VO) and vestibulo-perceptual (VP) time constants of decay, as well as VOR gain, were measured. Results: Prochlorperazine had no effect upon any measure of nystagmic or perceptual vestibular function compared to placebo. This lack of effects on vestibular-mediated motion perception suggests that the drug is likely to act more as an antiemetic than as an anti-vertiginous agent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A citologia de impressão da superfície ocular é uma técnica pouco invasiva que permite a análise de células da conjuntiva e da córnea, sendo uma alternativa aos esfregaços e punções. Desta forma, é indispensável garantir uma fase analítica eficiente. Na revisão bibliográfica encontram-se diversos agentes fixadores para este tipo de material, não sendo explícito o método de fixação mais eficaz. A fixação visa preservar os constituintes celulares quimicamente e estruturalmente, numa situação idêntica ao in vivo, estado este que é fundamental para a realização da técnica e consequente obtenção de um diagnóstico final correto. Objetivo do estudo - O objetivo deste estudo foi identificar o melhor fixador para amostras de citologia de impressão ocular – SureThin, PreservCyt, etanol a 95% e uma mistura constituída por formaldeído a 37%, ácido acético glacial e etanol a 70% (FAA 70%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the long-term outcome (up to 7 years) of presumed ocular tuberculosis (TB) when the therapeutic decision was based on WHO guidelines. METHODS: Twelve out of 654 new uveitic patients (1998-2004) presented with choroiditis and positive tuberculosis skin test (TST) (skin lesion diameter >15 mm). Therapy was administered according to WHO recommendations after ophthalmic and systemic investigation. The area size of ocular lesions at presentation and after therapy, measured on fluorescein and indocyanine green angiographies, was considered the primary outcome. Relapse of choroiditis was considered a secondary outcome. The T-SPOT TB test was performed when it became available. RESULTS: Visual acuity significantly improved after therapy (p=0.0357). The mean total surface of fluorescein lesions at entry was 44.8 ± 20.9 (arbitrary units) and decreased to 32.5 ± 16.9 after therapy (p=0.0165). The mean total surface of indocyanine green lesions at entry was 24.5 ± 13.3 and decreased to 10.8 ± 5.4 after therapy (p=0.0631). The T-SPOT TB revealed 2 false TST-positive results. The mean follow-up was 4.5 ± 1.5 years. Two relapses out of 10 confirmed ocular TB was observed after complete lesion healing, 2.5 years and 4.5 years after therapy, respectively. CONCLUSIONS: A decrease of ocular lesion mean size and a mean improvement of VA were observed after antituberculous therapy. Our long-term follow-up of chorioretinal lesions demonstrated relapse of ocular tuberculosis in 10% of patients with confirmed ocular TB, despite complete initial retinal scarring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cranial nerve schwannomas are radiologically characterized by nodular cranial nerve enhancement on magnetic resonance imaging (MRI). Schwannomas typically present with gradually progressive symptoms, but isolated reports have suggested that schwannomas may cause fluctuating symptoms as well. METHODS: This is a report of ten cases of presumed cranial nerve schwannoma that presented with transient or recurring ocular motor nerve deficits. RESULTS: Schwannomas of the third, fourth, and fifth nerves resulted in fluctuating deficits of all 3 ocular motor nerves. Persistent nodular cranial nerve enhancement was present on sequential MRI studies. Several episodes of transient oculomotor (III) deficts were associated with headaches, mimicking ophthalmoplegic migraine. CONCLUSIONS: Cranial nerve schwannomas may result in relapsing and remitting cranial nerve symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Digoxin intoxication results in predominantly digestive, cardiac and neurological symptoms. This case is outstanding in that the intoxication occurred in a nonagenarian and induced severe, extensively documented visual symptoms as well as dysphagia and proprioceptive illusions. Moreover, it went undiagnosed for a whole month despite close medical follow-up, illustrating the difficulty in recognizing drug-induced effects in a polymorbid patient. CASE PRESENTATION: Digoxin 0.25 mg qd for atrial fibrillation was prescribed to a 91-year-old woman with an estimated creatinine clearance of 18 ml/min. Over the following 2-3 weeks she developed nausea, vomiting and dysphagia, snowy and blurry vision, photopsia, dyschromatopsia, aggravated pre-existing formed visual hallucinations and proprioceptive illusions. She saw her family doctor twice and visited the eye clinic once until, 1 month after starting digoxin, she was admitted to the emergency room. Intoxication was confirmed by a serum digoxin level of 5.7 ng/ml (reference range 0.8-2 ng/ml). After stopping digoxin, general symptoms resolved in a few days, but visual complaints persisted. Examination by the ophthalmologist revealed decreased visual acuity in both eyes, 4/10 in the right eye (OD) and 5/10 in the left eye (OS), decreased color vision as demonstrated by a score of 1/13 in both eyes (OU) on Ishihara pseudoisochromatic plates, OS cataract, and dry age-related macular degeneration (ARMD). Computerized static perimetry showed non-specific diffuse alterations suggestive of either bilateral retinopathy or optic neuropathy. Full-field electroretinography (ERG) disclosed moderate diffuse rod and cone dysfunction and multifocal ERG revealed central loss of function OU. Visual symptoms progressively improved over the next 2 months, but multifocal ERG did not. The patient was finally discharged home after a 5 week hospital stay. CONCLUSION: This case is a reminder of a complication of digoxin treatment to be considered by any treating physician. If digoxin is prescribed in a vulnerable patient, close monitoring is mandatory. In general, when facing a new health problem in a polymorbid patient, it is crucial to elicit a complete history, with all recent drug changes and detailed complaints, and to include a drug adverse reaction in the differential diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumen tomado del autor. Contiene fotograf??as y tablas de las diferentes situaciones experimentales

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se estimó la sensibilidad y especificidad de la citología de impresión como prueba diagnóstica en lesiones conjuntivales clínicamente sospechosas de neoplasia usando como patrón de oro la patología. Se estudiaron 60 pacientes, que ingresaron al azar a la Fundación Oftalmológica Nacional, con diagnóstico clínico de neoplasia de superficie ocular o lesión sospechosa de neoplasia, quienes fueron sometidos a citología de impresión y posterior resección quirúrgica completa, más estudio patológico de la lesión. Se realizó un análisis descriptivo, analizando la sensibilidad y la especificidad con el método clásico y análisis bayesiano.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introducción: En la literatura, han aparecido reportes de neoplasia escamosa de superficie ocular (NESO) asociado con pterigio en un mismo paciente. Sin embargo, Colombia no cuenta con una estadística para ninguna de estas patologías. Objetivos: Determinar la frecuencia de NESO en pterigios resecados, en la Fundación Oftalmológica Nacional. Identificar factores de riesgo y características clínicas que predispongan a su aparición. Metodología: Estudio descriptivo de corte transversal. Se realizó una clasificación prequirúrgica y estudio histopatológico de los pterigios resecados en 93 pacientes, para confirmar su coexistencia con NESO. Se efectuó un análisis de frecuencias para datos demográficos y factores de riesgo asociados su aparición. Resultados: La frecuencia de NESO asociado a pterigio fue 7,07%. De estos, 28,5% identificados como sospechosos en la evaluación preoperatoria. La mayoría se presentaron en mujeres (71,4%), las ocupaciones con mayor frecuencia: labores domésticas (42,8%) y el comercio (28.5%). La exposición a derivados del petróleo y tabaquismo fue del 14,28%. No se presentaron casos asociados a infección por VIH. No hubo diferencias estadísticamente significativas sobre la presencia de NESO al comparar los casos en edad (p=0,8), procedencia (p=0,6) tabaquismo (p=0,4), leucoplaquia (p=1,0), queratinización (p=0,137), o vasos amputados (p=0,137). Conclusiones: De los pacientes con diagnóstico histopatológico de NESO, un porcentaje mínimo es sospechado clínicamente. Además se encontró este diagnóstico en pacientes más jóvenes que lo reportado en la literatura. Se recomienda realizar estudios con mayor número de pacientes para una mejor identificación de factores de riesgo. Palabras clave: