785 resultados para Ingeniería Industrial


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sloshing describes the movement of liquids inside partially filled tanks, generating dynamic loads on the tank structure. The resulting impact pressures are of great importance in assessing structural strength, and their correct evaluation still represents a challenge for the designer due to the high level of nonlinearities involved, with complex free surface deformations, violent impact phenomena and influence of air trapping. In the present paper, a set of two-dimensional cases, for which experimental results are available, is considered to assess the merits and shortcomings of different numerical methods for sloshing evaluation, namely two commercial RANS solvers (FLOW-3D and LS-DYNA), and two academic software (Smoothed Particle Hydrodynamics and RANS). Impact pressures at various critical locations and global moment induced by water motion in a partially filled rectangular tank, subject to a simple harmonic rolling motion, are evaluated and predictions are compared with experimental measurements. 2012 Copyright Taylor and Francis Group, LLC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There exists an interest in performing full core pin-by-pin computations for present nuclear reactors. In such type of problems the use of a transport approximation like the diffusion equation requires the introduction of correction parameters. Interface discontinuity factors can improve the diffusion solution to nearly reproduce a transport solution. Nevertheless, calculating accurate pin-by-pin IDF requires the knowledge of the heterogeneous neutron flux distribution, which depends on the boundary conditions of the pin-cell as well as the local variables along the nuclear reactor operation. As a consequence, it is impractical to compute them for each possible configuration. An alternative to generate accurate pin-by-pin interface discontinuity factors is to calculate reference values using zero-net-current boundary conditions and to synthesize afterwards their dependencies on the main neighborhood variables. In such way the factors can be accurately computed during fine-mesh diffusion calculations by correcting the reference values as a function of the actual environment of the pin-cell in the core. In this paper we propose a parameterization of the pin-by-pin interface discontinuity factors allowing the implementation of a cross sections library able to treat the neighborhood effect. First results are presented for typical PWR configurations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Interface discontinuity factors based on the Generalized Equivalence Theory are commonly used in nodal homogenized diffusion calculations so that diffusion average values approximate heterogeneous higher order solutions. In this paper, an additional form of interface correction factors is presented in the frame of the Analytic Coarse Mesh Finite Difference Method (ACMFD), based on a correction of the modal fluxes instead of the physical fluxes. In the ACMFD formulation, implemented in COBAYA3 code, the coupled multigroup diffusion equations inside a homogenized region are reduced to a set of uncoupled modal equations through diagonalization of the multigroup diffusion matrix. Then, physical fluxes are transformed into modal fluxes in the eigenspace of the diffusion matrix. It is possible to introduce interface flux discontinuity jumps as the difference of heterogeneous and homogeneous modal fluxes instead of introducing interface discontinuity factors as the ratio of heterogeneous and homogeneous physical fluxes. The formulation in the modal space has been implemented in COBAYA3 code and assessed by comparison with solutions using classical interface discontinuity factors in the physical space

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Within the framework of the Collaborative Project for a European Sodium Fast Reactor, the reactor physics group at UPM is working on the extension of its in-house multi-scale advanced deterministic code COBAYA3 to Sodium Fast Reactors (SFR). COBAYA3 is a 3D multigroup neutron kinetics diffusion code that can be used either as a pin-by-pin code or as a stand-alone nodal code by using the analytic nodal diffusion solver ANDES. It is coupled with thermalhydraulics codes such as COBRA-TF and FLICA, allowing transient analysis of LWR at both fine-mesh and coarse-mesh scales. In order to enable also 3D pin-by-pin and nodal coupled NK-TH simulations of SFR, different developments are in progress. This paper presents the first steps towards the application of COBAYA3 to this type of reactors. ANDES solver, already extended to triangular-Z geometry, has been applied to fast reactor steady-state calculations. The required cross section libraries were generated with ERANOS code for several configurations. The limitations encountered in the application of the Analytic Coarse Mesh Finite Difference (ACMFD) method –implemented inside ANDES– to fast reactors are presented and the sensitivity of the method when using a high number of energy groups is studied. ANDES performance is assessed by comparison with the results provided by ERANOS, using a mini-core model in 33 energy groups. Furthermore, a benchmark from the NEA for a small 3D FBR in hexagonal-Z geometry and 4 energy groups is also employed to verify the behavior of the code with few energy groups.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Technofusion is the scientific&technical installation for fusion research in Spain, based on three pillars: • It is an open facility to European users. • It is a facility with instrumentation not accesible to small research groups. • It is designed to be closely coordiated with the European Fusion Program. With a budget of 80-100 M€ over five years, several top laboratories will be constructed

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The increasing importance of pollutant noise has led to the creation of many new noise testing laboratories in recent years. For this reason and due to the legal implications that noise reporting may have, it is necessary to create procedures intended to guarantee the quality of the testing and its results. For instance, the ISO/IEC standard 17025:2005 specifies general requirements for the competence of testing laboratories. In this standard, interlaboratory comparisons are one of the main measures that must be applied to guarantee the quality of laboratories when applying specific methodologies for testing. In the specific case of environmental noise, round robin tests are usually difficult to design, as it is difficult to find scenarios that can be available and controlled while the participants carry out the measurements. Monitoring and controlling the factors that can influence the measurements (source emissions, propagation, background noise…) is not usually affordable, so the most extended solution is to create very effortless scenarios, where most of the factors that can have an influence on the results are excluded (sampling, processing of results, background noise, source detection…) The new approach described in this paper only requires the organizer to make actual measurements (or prepare virtual ones). Applying and interpreting a common reference document (standard, regulation…), the participants must analyze these input data independently to provide the results, which will be compared among the participants. The measurement costs are severely reduced for the participants, there is no need to monitor the scenario conditions, and almost any relevant factor can be included in this methodology

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper, a new countermeasure against power and electromagnetic (EM) Side Channel Attacks (SCA) on FPGA implemented cryptographic algorithms is proposed. This structure mainly focuses on a critical vulnerability, Early Evaluation, also known as Early Propagation Effect (EPE), which exists in most conventional SCA-hardened DPL (Dual-rail with Precharge Logic) solutions. The main merit of this proposal is that the EPE can be effectively prevented by using a synchronized non regular precharge network, which maintains identical routing between the original and mirror parts, where costs and design complexity compared with previous EPE-resistant countermeasures are reduced, while security level is not sacrificed. Another advantage for our Precharge Absorbed(PA) - DPL method is that its Dual-Core style (independent architecture for true and false parts) could be generated using partial reconfiguration. This helps to get a dynamic security protection with better energy planning. That means system only keeps the true part which fulfills the normal en/decryption task in low security level, and reconfigures the false parts once high security level is required. A relatively limited clock speed is a compromise, since signal propagation is restricted to a portion of the clock period. In this paper, we explain the principles of PA-DPL and provide the guidelines to design this structure. We experimentally validate our methods in a minimized AES co-processor on Xilinx Virtex-5 board using electromagnetic (EM) attacks.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Noise maps are usually represented as contour or isolines maps describing the sound levels in a region. Using this kind of representation the user can easily find the noise level assigned to every location in the map. But the acoustic calculations behind the map are not performed for every single location on it; they are only performed in a grid of receivers. The results in this calculation grid are interpolated to draw the isolines or contours. Therefore, the resolution of the calculation grid and the way it was created (rectangular, triangulated, random…) have an effect on the resulting map. In this paper we describe a smart iterative procedure to optimize the quality of the map at a really low additional computational cost, using self-adaptive grids for the acoustic calculations. These self-adaptive grids add new receivers to the sampling grid in those locations where they are expected to be more useful, so that the performance at the output of the interpolator is enhanced. Self-adaptive sampling grids can be used for minimizing the overall error of the map (improving its quality), or for reducing calculation times, and can be also applied selectively to target areas or contour lines. This can be done by the user customizing the maximum number of iterations, the number of new receivers for each iteration, the target isolines, the target quality…

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a theoretical analysis of possible jitter impact in application of numeric criterion for fastmeasurement of frequency by coincidence principle. The primary goal is the generation of a signal containing a known amount of each jitter components. This signal was used for testing signals with regular pulse trains. Initially, jitter components are analyzed and modeled individually. Next, sequences for combining different kinds of jitter are modeled, simulated and evaluated. Jitter model simulation in Matlab is utilized to show the independence of frequencymeasurement results on the total jitter present in the reference and desired pulse trains independently. A good agreement between previously introduced theory of fastmeasurement of frequency and simulation in jitter presence is verified; these results allows to engineers use the numeric criterion for fastmeasurement of frequency in spite to interactions among jitter components in various applications for frequency domain sensors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The research work that here is summarized, it is classed on the area of dynamics and measures of railway safety, specifically in the study of the influence of the cross wind on the high-speed trains as well as the study of new mitigation measures like wind breaking structures or wind fences, with optimized shapes. The work has been developed in the Research Center in Rail Technology (CITEF), and supported by the Universidad Politécnica de Madrid, Spain.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In order to satisfy the safety-critical requirements, the train control system (TCS) often employs a layered safety communication protocol to provide reliable services. However, both description and verification of the safety protocols may be formidable due to the system complexity. In this paper, interface automata (IA) are used to describe the safety service interface behaviors of safety communication protocol. A formal verification method is proposed to describe the safety communication protocols using IA and translate IA model into PROMELA model so that the protocols can be verified by the model checker SPIN. A case study of using this method to describe and verify a safety communication protocol is included. The verification results illustrate that the proposed method is effective to describe the safety protocols and verify deadlocks, livelocks and several mandatory consistency properties. A prototype of safety protocols is also developed based on the presented formally verifying method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En el año 2002 durante una inspección se localizó una importante corrosión en la cabeza de la vasija de Davis Besse NPP. Si no se hubiera producido esa detección temprana, la corrosión hubiera provocado una pequeña rotura en la cabeza de la vasija. La OECD/NEA consideró la importancia de simular esta secuencia en la instalación experimental ROSA, la cual fue reproducida posteriormente por grupos de investigación internacionales con varios códigos de planta. En este caso el código utilizado para la simulación de las secuencias experimentales es TRACE. Los resultados de este test experimental fueron muy analizados internacionalmente por la gran influencia que dos factores tenía sobre el resultado: las acciones del operador relativas a la despresurización y la detección del descubrimiento del núcleo por los termopares que se encuentran a su salida. El comienzo del inicio de la despresurización del secundario estaba basado en la determinación del descubrimiento del núcleo por la lectura de los temopares de salida del núcleo. En el experimento se registró un retraso importante en la determinación de ese descubrimiento, comenzando la despresurización excesivamente tarde y haciendo necesaria la desactivación de los calentadores que simulan el núcleo del reactor para evitar su daño. Dada las condiciones excesivamente conservadoras del test experimentale, como el fallo de los dos trenes de inyección de alta presión durante todo el transitorio, en las aplicaciones de los experimentos con modelo de Almaraz NPP, se ha optado por reproducir dicho accidente con condiciones más realistas, verificando el impacto en los resultados de la disponibilidad de los trenes de inyección de alta presión o los tiempos de las acciones manuales del operador, como factores más limitantes y estableciendo el diámetro de rotura en 1”

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La simulación de accidentes de rotura pequeña en el fondo de la vasija se aparta del convencional análisis de LOCA de rama fría, el más limitante en los análisis deterministas La rotura de una de las penetraciones de instrumentación de la vasija ha sido desestimada históricamente en los análisis de licencia y en los Análisis Probabilistas de Seguridad y por ello, hay una falta evidente de literatura para dicho análisis. En el año 2003 durante una inspección, se detectó una considerable corrosión en el fondo de la vasija de South Texas Project Unit I NPP. La evolución en el tiempo de dicha corrosión habría derivado en una pequeña rotura en el fondo de la vasija si su detección no se hubiera producido a tiempo. La OECD/NEA consideró la importancia de simular dicha secuencia en la instalación experimental ROSA, la cual fue reproducida posteriormente por grupos de investigación internacionales con varios códigos de planta. En este caso el código utilizado para la simulación de las secuencias experimentales es TRACE. Tanto en el experimento como en la simulación se observaron las dificultades de reinundar la vasija al tener la rotura en el fondo de la misma, haciendo clave la gestión del accidente por parte del operador. Dadas las condiciones excesivamente conservadoras del test experimental, como el fallo de los dos trenes de inyección de alta presión durante todo el transitorio, en las aplicaciones de los experimentos con modelo de Almaraz NPP, se ha optado por reproducir dicho accidente con condiciones más realistas, verificando el impacto en los resultados de la disponibilidad de los trenes de inyección de alta presión o los tiempos de las acciones manuales del operador, como factores más limitantes y estableciendo el diámetro de rotura en 1”

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report on the fabrication details of TES based on Mo/Au bilayers. The Mo layer is deposited by radio frequency (RF) sputtering and capped with a sputter deposited thin Au protection layer. Afterwards, a second Au layer of suitable (lower) resistivity is deposited ex‐situ by e‐beam evaporation, until completion of the total desired Au thickness. The deposition was performed at room temperature (RT) on LPCVD Si3 N4 membranes. Such a deposition procedure is very reproducible and allow controlling the critical temperature (Tc) and normal electrical resistance (RN ) of the Mo/Au bilayer. The process is optimized to achieve low stress bilayers, thus avoiding the undesirable curvature of the membranes. Bilayers are patterned using photolithographic techniques and wet etching procedures. Mo superconducting paths are used to contact the Mo/Au bilayers, thus ensuring good electrical conductivity and thermal isolation. The entire fabrication process let to stable and reproducible sensors with required and tunable functional properties

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The solaR package includes a set of functions to calculate the solar radiation incident on a photovoltaic generator and simulate the performance of several applications of the photovoltaic energy. This package performs the whole calculation procedure from both daily and intradaily global horizontal irradiation to the final productivity of grid connected PV systems and water pumping PV systems. The package stands on a set of S4 classes. The core of each class is a group of slots with yearly, monthly, daily and intradaily multivariate time series (with the zoo package ). The classes share a variety of methods to access the information (for example, as.zooD provides a zoo object with the daily multivariate time series of the corresponding object) and several visualisation methods based on the lattice andlatticeExtra packages.