868 resultados para High intensity exercise
Resumo:
PURPOSE OF REVIEW The primary focus of this review is threefold: first, to summarize available knowledge on exercise-associated glucose metabolism in individuals with type 1 diabetes mellitus (T1DM); second, to elucidate physiological mechanisms predisposing to glycemic variations in patients in T1DM; and third, to describe novel approaches derived from physiological perceptions applicable to stabilize exercise-related glycemia in individuals with T1DM. RECENT FINDINGS Recent studies corroborate the concept that despite partial differences in counter-regulatory mechanisms individuals with T1DM do not fundamentally differ in their glucose response to exercise when compared with healthy individuals if studies are performed under standardized conditions with insulin and glucose levels held close to physiological ranges. Novel approaches derived from a better understanding of exercise-associated glucose metabolism (e.g., the concept of intermittent high-intensity exercise) may provide alternative ways to master the challenges imposed by exercise to individuals with T1DM. SUMMARY Exercise still imposes high demands on patients with T1DM and increases risks for hypoglycemia and hyperglycemia. Deeper insight into the associated metabolic pathways has revealed novel options to stabilize exercise-associated glucose levels in these patients.
Resumo:
AIM Depending on intensity, exercise may induce a strong hormonal and metabolic response, including acid-base imbalances and changes in microcirculation, potentially interfering with the accuracy of continuous glucose monitoring (CGM). The present study aimed at comparing the accuracy of the Dexcom G4 Platinum (DG4P) CGM during continuous moderate and intermittent high-intensity exercise (IHE) in adults with type 1 diabetes (T1DM). METHODS Ten male individuals with well-controlled T1DM (HbA1c 7.0±0.6% [54±6mmol/mol]) inserted the DG4P sensor 2 days prior to a 90min cycling session (50% VO2peak) either with (IHE) or without (CONT) a 10s all-out sprint every 10min. Venous blood samples for reference glucose measurement were drawn every 10min and euglycemia (target 7mmol/l) was maintained using an oral glucose solution. Additionally, lactate and venous blood gas variables were determined. RESULTS Mean reference blood glucose was 7.6±0.2mmol/l during IHE and 6.7±0.2mmol/l during CONT (p<0.001). IHE resulted in significantly higher levels of lactate (7.3±0.5mmol/l vs. 2.6±0.3mmol/l, p<0.001), while pH values were significantly lower in the IHE group (7.27 vs. 7.38, p=0.001). Mean absolute relative difference (MARD) was 13.3±2.2% for IHE and 13.6±2.8% for CONT suggesting comparable accuracy (p=0.90). Using Clarke Error Grid Analysis, 100% of CGM values during both IHE and CONT were in zones A and B (IHE: 77% and 23%; CONT: 78% and 22%). CONCLUSIONS The present study revealed good and comparable accuracy of the DG4P CGM system during intermittent high intensity and continuous moderate intensity exercise, despite marked differences in metabolic conditions. This corroborates the clinical robustness of CGM under differing exercise conditions. CLINICAL TRIAL REGISTRATION NUMBER ClinicalTrials.gov NCT02068638.
Resumo:
OBJECTIVES Levels of inflammatory biomarkers associate with changes of coronary atheroma burden in statin-treated patients with stable coronary artery disease. This study sought to determine changes of plaque composition in vivo in relation to high-sensitivity C-reactive protein (hs-CRP) levels in patients with ST-elevation myocardial infarction (STEMI) receiving high-intensity statin therapy. METHODS The IBIS-4 study performed serial (baseline and 13-month), 2-vessel intravascular ultrasound (IVUS) and radiofrequency-IVUS of the non-infarct-related arteries in patients with STEMI treated with high-intensity statin therapy. The present analysis included 44 patients (80 arteries) with serial measurements of hs-CRP. RESULTS At follow-up, median low-density lipoprotein cholesterol (LDL-C) levels decreased from 126 to 77 mg/dl, HDL-C increased from 44 to 47 mg/dl, and hs-CRP decreased from 1.6 to 0.7 mg/L. Regression of percent atheroma volume (-0.99%, 95% CI -1.84 to -0.14, p = 0.024) was accompanied by reduction of percent fibro-fatty (p = 0.04) and fibrous tissue (p < 0.001), and increase in percent necrotic core (p = 0.006) and dense calcium (p < 0.001). Follow-up levels of hs-CRP, but not LDL-C, correlated with changes in percent necrotic core (p = 0.001) and inversely with percent fibrous tissue volume (p = 0.008). Similarly, baseline-to-follow-up change of hs-CRP correlated with the change in percent necrotic core volume (p = 0.02). CONCLUSIONS In STEMI patients receiving high-intensity statin therapy, stabilization of VH-IVUS-defined necrotic core was confined to patients with lowest on-treatment levels and greatest reduction of hs-CRP. Elevated CRP levels at follow-up may identify progression of high-risk coronary plaque composition despite intensive statin therapy and overall regression of atheroma volume.
Resumo:
The intensity of care for patients at the end-of-life is increasing in recent years. Publications have focused on intensity of care for many cancers, but none on melanoma patients. Substantial gaps exist in knowledge about intensive care and its alternative, hospice care, among the advanced melanoma patients at the end of life. End-of-life care may be used in quite different patterns and induce both intended and unintended clinical and economic consequences. We used the Surveillance, Epidemiology, and End Results (SEER)-Medicare linked databases to identify patients aged 65 years or older with metastatic melanoma who died between 2000 and 2007. We evaluated trends and associations between sociodemographic and health services characteristics and the use of hospice care, chemotherapy, surgery, and radiation therapy and costs. Survival, end-of-life costs, and incremental cost-effectiveness ratio were evaluated using propensity score methods. Costs were analyzed from the perspective of Medicare in 2009 dollars. In the first journal Article we found increasing use of surgery for patients with metastatic melanoma from 13% in 2000 to 30% in 2007 (P=0.03 for trend), no significant fluctuation in use of chemotherapy (P=0.43) or radiation therapy (P=0.46). Older patients were less likely to receive radiation therapy or chemotherapy. The use of hospice care increased from 61% in 2000 to 79% in 2007 (P =0.07 for trend). Enrollment in short-term (1-3 days) hospice care use increased, while long-term hospice care (≥ 4 days) remained stable. Patients living in the SEER Northeast and South regions were less likely to undergo surgery. Patients enrolled in long-term hospice care used significantly less chemotherapy, surgery and radiation therapy. In the second journal article, of 611 patients identified for this study, 358 (59%) received no hospice care after their diagnosis, 168 (27%) received 1 to 3 days of hospice care, and 85 (14%) received 4 or more days of hospice care. The median survival time was 181 days for patients with no hospice care, 196 days for patients enrolled in hospice for 1 to 3 days, and 300 days for patients enrolled for 4 or more days (log-rank test, P < 0.001). The estimated hazard ratios (HR) between 4 or more days hospice use and survival were similar within the original cohort Cox proportional hazard model (HR, 0.62; 95% CI, 0.49-0.78, P < 0.0001) and the propensity score-matched model (HR, 0.61; 95% CI, 0.47-0.78, P = 0.0001). Patients with ≥ 4 days of hospice care incurred lower end-of-life costs than the other two groups ($14,298 versus $19,380 for the 1- to 3-days hospice care, and $24,351 for patients with no hospice care; p < 0.0001). In conclusion, Surgery and hospice care use increased over the years of this study while the use of chemotherapy and radiation therapy remained consistent for patients diagnosed with metastatic melanoma. Patients diagnosed with advanced melanoma who enrolled in ≥ 4 days of hospice care experienced longer survival than those who had 1-3 days of hospice or no hospice care, and this longer overall survival was accompanied by lower end-of-life costs.^
Resumo:
Outline: • Introduction • Process Experimental Setup • Experimental Procedure • Experimental Results for Al2024-T351 and Ti6Al4V - Residual stresses - Tensile Strength - Fatigue Life • Discussion and Outlook - Prospects for technological applications of LSP
Resumo:
The interaction of high intensity X-ray lasers with matter is modeled. A collisional-radiative timedependent module is implemented to study radiation transport in matter from ultrashort and ultraintense X-ray bursts. Inverse bremsstrahlung absorption by free electrons, electron conduction or hydrodynamic effects are not considered. The collisional-radiative system is coupled with the electron distribution evolution treated with a Fokker-Planck approach with additional inelastic terms. The model includes spontaneous emission, resonant photoabsorption, collisional excitation and de-excitation, radiative recombination, photoionization, collisional ionization, three-body recombination, autoionization and dielectronic capture. It is found that for high densities, but still below solid, collisions play an important role and thermalization times are not short enough to ensure a thermal electron distribution. At these densities Maxwellian and non-Maxwellian electron distribution models yield substantial differences in collisional rates, modifying the atomic population dynamics.
Resumo:
High Intensity Lasers Application to Advanced Materials Processing: Laser Peening and Related
Resumo:
In the work, the results of an investigation of GaInP/GaInAs/Ge MJ SCs intended for converting concentrated solar radiation, when operating at low temperatures (down to -190 degrees C) are presented. A kink of the cell I-V characteristic has been observed in the region close to V-oc starting from -20 degrees C at operation under concentrated sunlight. The causes for its occurrence have been analyzed and the reasons for formation of a built-in potential barrier for majority charge carriers at the n-GaInP/n-Ge isotype hetero-interface are discussed. The effect of charge carrier transport in n-GaInP/n-p Ge heterostructures on MJ SC output characteristics at low temperatures has been studied including EL technique.
Resumo:
Trata de una conferencia invitada que ganó premio a la mejor comunicación científica.
Resumo:
CPV receivers are made of materials with very different lineal expansion coefficients. Strong variations in DNI due to the passage of clouds can cause sudden temperature changes that creates mechanical stress. For common solder and metal filled polymers the plastic limit could be reached causing substantial fatigue. The best forecast of receiver reliability is therefore achieved by applying an intermittent light source with nominal irradiance level and a number of cycles equal to the expected cloud passages for a given site. The UPM has developed specialized equipment, dubbed the LYSS (Light cYcling Stressing Source), for carrying out such experiments. The small thermal capacity of receivers allows simulating more than 25000 cycles per week. The number of deep transients expected for Madrid in 30 years operation, based on available data, is about 45000. We are currently using the system to cycle a ?Ge/Ag Epoxy/aluminum? receiver, which shows no degradation after 20000 cycles. The equipment can cast up to 200 and 70 W/cm2 on 0.1 and 1 cm2 cells, respectively.
Resumo:
After construction of the LYSS (Light cYcling Stressing Source) in early 2014, several CPV receivers, with and without secondary optical element (SOE) have been aged under fast transient illumination cycling,. The test plan for Madrid consisted of 50000 cycles. Receivers with poor heat spreaders showed low reliability but those with thicker metal layers passed the test well. The operation of LYSS along 8 months, after more than 250000 cycles, did not show any significant failure, except lamp reposition every 120 hours, in average. The equipment seems valid for unveiling weak receiver designs with respect to intensive illumination, in steady and transient modes.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.