Accuracy of continuous glucose monitoring during differing exercise conditions.


Autoria(s): Bally, Lia; Züger, Thomas; Pasi, Nicola; Ciller, Carlos; Paganini, Daniela; Stettler, Christoph
Data(s)

01/02/2016

Resumo

AIM Depending on intensity, exercise may induce a strong hormonal and metabolic response, including acid-base imbalances and changes in microcirculation, potentially interfering with the accuracy of continuous glucose monitoring (CGM). The present study aimed at comparing the accuracy of the Dexcom G4 Platinum (DG4P) CGM during continuous moderate and intermittent high-intensity exercise (IHE) in adults with type 1 diabetes (T1DM). METHODS Ten male individuals with well-controlled T1DM (HbA1c 7.0±0.6% [54±6mmol/mol]) inserted the DG4P sensor 2 days prior to a 90min cycling session (50% VO2peak) either with (IHE) or without (CONT) a 10s all-out sprint every 10min. Venous blood samples for reference glucose measurement were drawn every 10min and euglycemia (target 7mmol/l) was maintained using an oral glucose solution. Additionally, lactate and venous blood gas variables were determined. RESULTS Mean reference blood glucose was 7.6±0.2mmol/l during IHE and 6.7±0.2mmol/l during CONT (p<0.001). IHE resulted in significantly higher levels of lactate (7.3±0.5mmol/l vs. 2.6±0.3mmol/l, p<0.001), while pH values were significantly lower in the IHE group (7.27 vs. 7.38, p=0.001). Mean absolute relative difference (MARD) was 13.3±2.2% for IHE and 13.6±2.8% for CONT suggesting comparable accuracy (p=0.90). Using Clarke Error Grid Analysis, 100% of CGM values during both IHE and CONT were in zones A and B (IHE: 77% and 23%; CONT: 78% and 22%). CONCLUSIONS The present study revealed good and comparable accuracy of the DG4P CGM system during intermittent high intensity and continuous moderate intensity exercise, despite marked differences in metabolic conditions. This corroborates the clinical robustness of CGM under differing exercise conditions. CLINICAL TRIAL REGISTRATION NUMBER ClinicalTrials.gov NCT02068638.

Formato

application/pdf

Identificador

http://boris.unibe.ch/78550/1/1-s2.0-S0168822715004726-main.pdf

Bally, Lia; Züger, Thomas; Pasi, Nicola; Ciller, Carlos; Paganini, Daniela; Stettler, Christoph (2016). Accuracy of continuous glucose monitoring during differing exercise conditions. Diabetes research and clinical practice, 112, pp. 1-5. Elsevier 10.1016/j.diabres.2015.11.012 <http://dx.doi.org/10.1016/j.diabres.2015.11.012>

doi:10.7892/boris.78550

info:doi:10.1016/j.diabres.2015.11.012

info:pmid:26739116

urn:issn:0168-8227

Idioma(s)

eng

Publicador

Elsevier

Relação

http://boris.unibe.ch/78550/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Bally, Lia; Züger, Thomas; Pasi, Nicola; Ciller, Carlos; Paganini, Daniela; Stettler, Christoph (2016). Accuracy of continuous glucose monitoring during differing exercise conditions. Diabetes research and clinical practice, 112, pp. 1-5. Elsevier 10.1016/j.diabres.2015.11.012 <http://dx.doi.org/10.1016/j.diabres.2015.11.012>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed