898 resultados para Effect of ethanol on brain DA receptors


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resistivity behaviour of PbO---PbX2 (X=F,Cl) glasses has been investigated as a function of pressure at laboratory temperature. All PbO---PbX2 glasses undergo crystallization under pressure and the resistivities of crystallized samples are lower than the corresponding glasses. Transitions in PbO---PbF2 glasses exhibit a first order behaviour while transitions in PbO---PbCl2 glasses possess features of a continuous transition. The differences in the pressure behaviour of the two glass systems have been attributed to the differences in the ionic sizes of F− and Cl− ions and also to pressure induced modifications of Pb---O bonding.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The crystal structures of (1) L-arginine D-asparate, C6HIsN40~.C4H6NO4 [triclinic, P1, a=5.239(1), b=9.544(1), c=14.064(2)A, a=85"58(1), /3=88.73 (1), ~/=84.35 (1) °, Z=2] and (2) L-arginine D-glutamate trihydrate, C6H15N40~-.CsHsNO4.3H20 [monoclinic, P2~, a=9.968(2), b=4.652(1), c=19.930 (2) A, fl = 101.20 (1) °, Z = 2] have been determined using direct methods. They have been refined to R =0.042 and 0.048 for 2829 and 2035 unique reflections respectively [I>2cr(I)]. The conformations of the two arginine molecules in the aspartate complex are different from those observed so far in the crystal structures of arginine, its salts and complexes. In both complexes, the molecules are organized into double layers stacked along the longest axis. The core of each double layer consists of two parallel sheets made up of main-chain atoms, each involving both types of molecules. The hydrogen bonds within each sheet and those that interconnect the two sheets give rise to EL-, DD- and DE-type head-to-tail sequences. Adjacent double layers in (1) are held together by side-chain-side-chain interactions whereas those in (2) are interconnected through an extensive network of water molecules which interact with sidechain guanidyl and carboxylate groups. The aggregation pattern observed in the two LD complexes is fundamentally different from that found in the corresponding EL complexes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of radiation on the Peierls transition in a one-dimensional metal is investigated. It is pointed out that an external radiation field satisfying appropriate frequency conditions reduces the width of the Peierls gap.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sleepiness remains a primary cause of road crashes, the major cause of death in young adults. Light is known to produce a direct alerting effect, but little is known about its effects on sleepy drivers. This study aimed to compare the effect of blue-green light and caffeine on young drivers’ cognitive performance after chronic-partial sleep loss.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of fungal endophyte (Neotyphodium lolii) infection on the performance of perennial ryegrass (Lolium perenne) growing under irrigation in a subtropical environment was investigated. Seed of 4 cultivars, infected with standard (common toxic or wild-type) endophyte or the novel endophyte AR1, or free of endophyte (Nil), was sown in pure swards, which were fertilised with 50 kg N/ha.month. Seasonal and total yield, persistence, and rust susceptibility were assessed over 3 years, along with details of the presence of endophyte and alkaloids in plant shoots. Endophyte occurrence in tillers in both the standard and AR1 treatments was above 95% for Bronsyn and Impact throughout and rose to that level in Samson by the end of the second year. Meridian AR1 only reached 93% while, in the standard treatment, the endophyte had mostly died before sowing. Nil Zendophyte treatments carried an average of ?0.6% infection throughout. Infection of the standard endophyte was associated with increased dry matter (DM) yields in all 3 years compared with no endophyte. AR1 also significantly increased yields in the second and third years. Over the full 3 years, standard and AR1 increased yields by 18% and 11%, respectively. Infection with both endophytes was associated with increased yields in all 4 seasons, the effects increasing in intensity over time. There was 27% better persistence in standard infected plants compared with Nil at the end of the first year, increasing to 198% by the end of the experiment, while for AR1 the improvements were 20 and 134%, respectively. The effect of endophyte on crown rust (Puccinia coronata) infection was inconsistent, with endophyte increasing rust damage on one occasion and reducing it on another. Cultivar differences in rust infection were greater than endophyte effects. Plants infected with the AR1 endophyte had no detectable ergovaline or lolitrem B in leaf, pseudostem, or dead tissue. In standard infected plants, ergovaline and lolitrem B were highest in pseudostem and considerably lower in leaf. Dead tissue had very low or no detectable ergovaline but high lolitrem B concentrations. Peramine concentration was high and at similar levels in leaf and pseudostem, but not detectable in dead material. Concentration was similar in both AR1 and standard infected plants. Endophyte presence appeared to have a similar effect in the subtropics as has been demonstrated in temperate areas, in terms of improving yields and persistence and increasing tolerance of plants to stress factors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Auto-ignition temperature of polystyrene, poly(vinyl chloride) and carboxy terminated polybutadiene has been measured at various oxygen pressures (1-28 atm) in a high pressure differential thermal analysis assembly at a heating rate of 10°C/min. The exothermic peak appears between 250-350°C in polystyrene and poly(vinyl chloride) and between 150-200°C for carboxy terminated polybutadiene. Ignition appears to be controlled by in situ forma tion and degradation of polymeric peroxides. Inverse dependence of ignition temperature on oxygen pressure is explained by the rate equation which con siders that ignition of a particular sample, of a fixed geometry, occurs when gasification rate reaches a unique critical value.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

[Excerpt] The effects of framing on decisions has been widely studied, producing research that suggests individuals respond to framing in predictable and fairly consistent ways (Bazerman, 1984, 1990; Tversky & Kahneman, 1986; Thaler, 1980). The essential finding from this body of research is that "individuals treat risks concerning perceived gains (for example, saving jobs and plants) differently from risks concerning perceived losses (losing jobs and plants)" (Bazerman, 1990, pp. 49-50). Specifically, individuals tend to avoid risks concerning gains, and seek risks concerning losses.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The possible occurrence of a generalized (1-wave) nonequilibrium superconducting state in a multiband system under certain conditions is studied. In the model the radiation field causes interband mixing, and phonons of an appropriate mode (branch) are involved in the interband scattering of electrons of two conduction bands of the system. The strength of the generalized 1-wave pairing interaction between quasiparticles belonging to new radiation admixed states depends on the density (n o/V) of quanta in the system. The coupling constant has the form Xl= AiB(n o/V)/[C + B(no/V)], where A1, B, and C are parameters. For C > B(n0/V), the transition temperature T1* increases with (no/V) in the initial stages. It levels off with higher power. With further increase of power, the transition temperature is expected to drop sharply due to heating effects which cause pair breaking. Estimates show that p-wave (triplet state) pairing may be possible under radiation-induced nonequilibrium situations in appropriate systems. Estimates for lifetimes of various processes quasiparticle, phonon, pair relaxation, and photon-induced mixing) show that the coherence required for the mixing and pairing effects will be maintained for the temperature range and photon density considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Markerless motion capture systems are relatively new devices that can significantly speed up capturing full body motion. A precision of the assessment of the finger’s position with this type of equipment was evaluated at 17.30 ± 9.56 mm when compare to an active marker system [1]. The Microsoft Kinect was proposed to standardized and enhanced clinical evaluation of patients with hemiplegic cerebral palsy [2]. Markerless motion capture systems have the potential to be used in a clinical setting for movement analysis, as well as for large cohort research. However, the precision of such system needs to be characterized. Global objectives • To assess the precision within the recording field of the markerless motion capture system Openstage 2 (Organic Motion, NY). • To compare the markerless motion capture system with an optoelectric motion capture system with active markers. Specific objectives • To assess the noise of a static body at 13 different location within the recording field of the markerless motion capture system. • To assess the smallest oscillation detected by the markerless motion capture system. • To assess the difference between both systems regarding the body joint angle measurement. Methods Equipment • OpenStage® 2 (Organic Motion, NY) o Markerless motion capture system o 16 video cameras (acquisition rate : 60Hz) o Recording zone : 4m * 5m * 2.4m (depth * width * height) o Provide position and angle of 23 different body segments • VisualeyezTM VZ4000 (PhoeniX Technologies Incorporated, BC) o Optoelectric motion capture system with active markers o 4 trackers system (total of 12 cameras) o Accuracy : 0.5~0.7mm Protocol & Analysis • Static noise: o Motion recording of an humanoid mannequin was done in 13 different locations o RMSE was calculated for each segment in each location • Smallest oscillation detected: o Small oscillations were induced to the humanoid mannequin and motion was recorded until it stopped. o Correlation between the displacement of the head recorded by both systems was measured. A corresponding magnitude was also measured. • Body joints angle: o Body motion was recorded simultaneously with both systems (left side only). o 6 participants (3 females; 32.7 ± 9.4 years old) • Tasks: Walk, Squat, Shoulder flexion & abduction, Elbow flexion, Wrist extension, Pronation / supination (not in results), Head flexion & rotation (not in results), Leg rotation (not in results), Trunk rotation (not in results) o Several body joint angles were measured with both systems. o RMSE was calculated between signals of both systems. Results Conclusion Results show that the Organic Motion markerless system has the potential to be used for assessment of clinical motor symptoms or motor performances However, the following points should be considered: • Precision of the Openstage system varied within the recording field. • Precision is not constant between limb segments. • The error seems to be higher close to the range of motion extremities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lutein (3,3'-dihydroxy alpha-carotene), a xanthophyll present in plant chloroplasts, increases the permeability of phospholipid vesicles to Ca2+, even though the pigment does not bind the metal ion. Energy-dependent uptake of Ca2+ by mitochondria is inhibited by lutein, which permits a rapid efflux of the ion from Ca2+-loaded mitochondria. These results are consistent with the view that the deleterious action of lutein on mitochondrial oxidative phosphorylation results from its destabilizing action on membrane structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of temperature on height growth of Scots pine in the northern boreal zone in Lapland was studied in two different time scales. Intra-annual growth was monitored in four stands in up to four growing seasons using an approximately biweekly measurement interval. Inter-annual growth was studied using growth records representing seven stands and five geographical locations. All the stands were growing on a dry to semi-dry heath that is a typical site type for pine stands in Finland. The applied methodology is based on applied time-series analysis and multilevel modelling. Intra-annual elongation of the leader shoot correlated with temperature sum accumulation. Height growth ceased when, on average, 41% of the relative temperature sum of the site was achieved (observed minimum and maximum were 38% and 43%). The relative temperature sum was calculated by dividing the actual temperature sum by the long-term mean of the total annual temperature sum for the site. Our results suggest that annual height growth ceases when a location-specific temperature sum threshold is attained. The positive effect of the mean July temperature of the previous year on annual height increment proved to be very strong at high latitudes. The mean November temperature of the year before the previous had a statistically significantly effect on height increment in the three northernmost stands. The effect of mean monthly precipitation on annual height growth was statistically insignificant. There was a non-linear dependence between length and needle density of annual shoots. Exceptionally low height growth results in high needle-density, but the effect is weaker in years of average or good height growth. Radial growth and next year s height growth are both largely controlled by current July temperature. Nevertheless, their growth variation in terms of minimum and maximum is not necessarily strongly correlated. This is partly because height growth is more sensitive to changes in temperature. In addition, the actual effective temperature period is not exactly the same for these two growth components. Yet, there is a long-term balance that was also statistically distinguishable; radial growth correlated significantly with height growth with a lag of 2 years. Temperature periods shorter than a month are more effective variables than mean monthly values, but the improvement is on the scale of modest to good when applying Julian days or growing-degree-days as pointers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An irreversible pressure induced semiconductor-to-metal transition in bulk Ge20Te80 glass is observed at about 5 GPa pressure. The high pressure phase has a face centered cubic structure with a lattice constant 6.42 A° as deduced by X-ray diffraction studies on the pressure quenched samples. The temperature and pressure dependence of the electrical resistivity confirms the observed transition to be a semiconductor-to-metal transition. The temperature dependence of thermo electric power is also reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract In weed biocontrol, similarity of abiotic factors between the native and introduced range of a biocontrol agent is critical to its establishment and effectiveness. This is particularly the case for weeds that have a wide geographical distribution in the native range. For such weeds, the choice of a specialist insect that has narrow tolerance limits to important abiotic factors can diminish its ability to be an effective biocontrol agent. The membracid Aconophora compressa was introduced in Australia from Mexico for biocontrol of Lantana camara, a plant with a wide climatic tolerance. In this study we investigated the effect of constant and alternating temperatures on A. compressa survival. Longevity of adults and nymphs declined with increasing temperatures, and at 39°C individuals survived for less than a day. At lower temperatures, nymphs survived longer than adults. Survival at alternating temperatures was longer than at constant temperatures, but the general trend of lower survival at higher temperatures remained. Spatially and temporally, the climatic tolerance of A. compressa appears to be a subset of that of lantana, thereby limiting its potential impact.