990 resultados para ECR ion source
Resumo:
Computations at the RCCSD(T)/aug-cc-pVDZ//B3LYP/6-31G* level of theory indicate that neutral C6CO is a stable species. The ground state of this neutral is the singlet cumulene oxide :C=C=C=C=C=C=C=O. The adiabatic electron affinity and dipole moment of singlet C6CO are 2.47 eV and 4.13 D, respectively, at this level of theory. The anion (C6CO)(-.) should be a possible precursor to this neutral. It has been formed by an unequivocal synthesis in the ion source of a mass spectrometer by the S(N)2(Si) reaction between (CH3)(3)Si-C=C-C=C-C=C-CO-CMe3 and F- to form C-=C-C=C-C=C-CO-CMe3 which loses Me3C in the source to form C6CO-.. Charge stripping of this anion by vertical Franck-Condon oxidation forms C6CO, characterised by the neutralisation-reionisation spectrum (-NR+) of C6CO-., which is stable during the timeframe of this experiment (10(-6) s), Copyright (C) 2000 John Wiley & Sons, Ltd.
Resumo:
2,3-Dimethyl-2,3-dinitrobutane (DMNB) is an explosive taggant added to plastic explosives during manufacture making them more susceptible to vapour-phase detection systems. In this study, the formation and detection of gas-phase \[M+H](+), \[M+Li](+), \[M+NH(4)](+) and \[M+Na](+) adducts of DMNB was achieved using electrospray ionisation on a triple quadrupole mass spectrometer. The \[M+H](+) ion abundance was found to have a strong dependence on ion source temperature, decreasing markedly at source temperatures above 50 degrees C. In contrast, the \[M+Na](+) ion demonstrated increasing ion abundance at source temperatures up to 105 degrees C. The relative susceptibility of DMNB adduct ions toward dissociation was investigated by collision-induced dissociation. Probable structures of product ions and mechanisms for unimolecular dissociation have been inferred based on fragmentation patterns from tandem mass (MS/MS) spectra of source-formed ions of normal and isotopically labelled DMNB, and quantum chemical calculations. Both thermal and collisional activation studies suggest that the \[M+Na](+) adduct ions are significantly more stable toward dissociation than their protonated analogues and, as a consequence, the former provide attractive targets for detection by contemporary rapid screening methods such as desorption electrospray ionisation mass spectrometry. Copyright (C) 2009 Commonwealth of Australia. Published by John Wiley & Sons, Ltd.
Resumo:
Both [C4CO]−· and [C2COC2]−· are formed in the ion source of a VG ZAB 2HF mass spectrometer by the respective processes HO− + Me3Si–CC–CC–CO–CMe3 → [C4CO]−· + Me3SiOH + Me3C·, and Me3Si–CC–CO–CC–SiMe3 + SF6 + e → [C2COC2]−· + 2Me3SiF + SF4. The second synthetic pathway involves a double desilylation reaction similar to that first reported by Squires. The two radical anion isomers produce different and characteristic charge reversal spectra upon collisional activation. In contrast, following collision induced charge stripping, both radical anions produce neutral C4CO as evidenced by the identical neutralisation reionisation (−NR+) spectra. The exclusive rearrangement of C213COC2 to C413CO indicates that 12C–O bond formation is not involved in the reaction. Ab initio calculations (at the RCCSD(T)/aug-cc-pVDZ//B3LYP/6-31G∗ level of theory) have been used to investigate the reaction coordinates on the potential surfaces for both singlet and triplet rearrangements of neutral C2COC2. Singlet C2COC2 is less stable than singlet C4CO by 78.8 kcal mol−1 and requires only 8.5 kcal mol−1 of additional energy to effect conversion to C4CO by a rearrangement sequence involving three C–C ring opening/cyclisation steps.
Resumo:
Phospholipids are the key structural component of cell membranes, and recent advances in electrospray ionization mass spectrometry provide for the fast and efficient analysis of these compounds in biological extracts.1-3 The application of electrospray ionization tandem mass spectrometry (ESI-MS/MS) to phospholipid analysis has demonstrated several key advantages over the more traditional chromatographic methods, including speed and greater structural information.4 For example, the ESI-MS/MS spectrum of a typical phospholipidsparticularly in negative ion modesreadily identifies the carbon chain length and the degree of unsaturation of each of the fatty acids esterified to the parent molecule.5 A critical limitation of conventional ESI-MS/MS analysis, however, is the inability to uniquely identify the position of double bonds within the fatty acid chains. This is especially problematic given the importance of double bond position in determining the biological function of lipid classes.6 Previous attempts to identify double bond position in intact phospholipids using mass spectrometry employ either MS3 or offline chemical derivatization.7-11 The former method requires specialized instrumentation and is rarely applied, while the latter methods suffer from complications inherent in sample handling prior to analysis. In this communication we outline a novel on-line approach for the identification of double bond position in intact phospholipids. In our method, the double bond(s) present in unsaturated phospholipids are cleaved by ozonolysis within the ion source of a conventional ESI mass spectrometer to give two chemically induced fragment ions that may be used to unambiguously assign the position of the double bond. This is achieved by using oxygen as the electrospray nebulizing gas in combination with high electrospray voltages to initiate the formation of an ozoneproducing.
Resumo:
Consideration of theoretical calculations \[E3LYP/aug-cc-pVDZ//B3LYP/6-31G(d)\] of the structures of ten C7H2 neutral isomers and the nine corresponding C7H2 radical anions have led us to synthesize four stable C7H2 radical anions in the ion source of our ZAB 2HF mass spectrometer, and to convert these to C7H2 neutrals. The four radical anion isomers prepared were (i) \[(HC equivalent to C)(2)C=C=C\](-.) \[from the reaction between (HC equivalent to C)(3)COCH3 and HO- \], (ii) \[HC=C=C=C=C=C=CH\](-.) \[from the reaction between HC equivalent to C-C equivalent to C-CD(OH)-C equivalent to CH and HO-\], (iii) \[C=C=C=C=C=C=CH2\](-.) \[from the reaction between DC equivalent to C-C equivalent to C-C equivalent to C-CH2OCH2CH3 and HO-\], and (iv) \[C equivalent to C-CH2-C equivalent to C-C equivalent to C\](-.) \[from the bis desilylation reaction of (CH3)(3)Si-C equivalent to C-CH2-C equivalent to C-C equivalent to C-Si (CH3)(3)With SF6-.\]. The four anions were further characterized by their collisional activation (negative ion) and charge reversal (CR, positive ion) mass spectra. The anions were converted into their corresponding neutrals by charge stripping, and the correspondence between the charge reversal (CR) and neutralization reionization (-NR+) mass spectra of each anion is taken as evidence that within the time frame of the -NR+ experiment (some 10(-6) s), each neutral is stable and undergoes no major rearrangement or interconversion to a more stable isomer. Theory and experiment are in accord for these systems.
Resumo:
Consideration of theoretical calculations [B3LYP/aug-cc-pVDZ//B3LYP/6-31G(d)] of the structures of ten C7H2 neutral isomers and the nine corresponding C7H2 radical anions have led us to synthesize four stable C7H2 radical anions in the ion source of our ZAB 2HF mass spectrometer, and to convert these to C7H2 neutrals. The four radical anion isomers prepared were (i) [(HC≡C)2C=C=C]-̇ [from the reaction between (HC≡C)3COCH3 and HO- ], (ii) [HC=C=C=C=C=C=CH]-̇ [from the reaction between HC≡C-C≡C- CD(OH)-C≡CH and HO-], (iii) [C=C=C=C=C=C=CH2]-̇ [from the reaction between DC≡C-C≡C- C≡C-CH2OCH2CH3 and HO-], and (iv) [C≡C-CH2-C≡C-C≡C]-̇ [from the bis desilylation reaction of (CH3)3Si-C≡C-CH2-C≡C-C≡C-Si (CH3)3 with SF6 -̇]. The four anions were further characterized by their collisional activation (negative ion) and charge reversal (CR, positive ion) mass spectra. The anions were converted into their corresponding neutrals by charge stripping, and the correspondence between the charge reversal (CR) and neutralization reionization (-NR+) mass spectra of each anion is taken as evidence that within the time frame of the -NR+ experiment (some 10-6 s), each neutral is stable and undergoes no major rearrangement or interconversion to a more stable isomer. Theory and experiment are in accord for these systems.
Resumo:
Using a combination of multivariate statistical techniques and the graphical assessment of major ion ratios, the influences on hydrochemical variability of coal seam gas (or coal bed methane) groundwaters from several sites in the Surat and Clarence-Moreton basins in Queensland, Australia, were investigated. Several characteristic relationships between major ions were observed: 1) strong positive linear correlation between the Na/Cl and alkalinity/Cl ratios; 2) an exponentially decaying trend between the Na/Cl and Na/alkalinity ratios; 3) inverse linear relationships between increasing chloride concentrations and decreasing pH for high salinity groundwaters, and; 4) high residual alkalinity for lower salinity waters, and an inverse relationship between decreasing residual alkalinity and increasing chloride concentrations for more saline waters. The interpretation of the hydrochemical data provides invaluable insights into the hydrochemical evolution of coal seam gas (CSG) groundwaters that considers both the source of major ions in coals and the influence of microbial activity. Elevated chloride and sodium concentrations in more saline groundwaters appear to be influenced by organic-bound chlorine held in the coal matrix; a sodium and chloride ion source that has largely been neglected in previous CSG groundwater studies. However, contrastingly high concentrations of bicarbonate in low salinity waters could not be explained, and are possibly associated with a number of different factors such as coal degradation, methanogenic processes, the evolution of high-bicarbonate NaHCO3 water types earlier on in the evolutionary pathway, and variability in gas reservoir characteristics. Using recently published data for CSG groundwaters in different basins, the characteristic major ion relationships identified for new data presented in this study were also observed in other CSG groundwaters from Australia, as well as for those in the Illinois Basin in the USA. This observation suggests that where coal maceral content and the dominant methanogenic pathway are similar, and where organic-bound chlorine is relatively abundant, distinct hydrochemical responses may be observed. Comparisons with published data of other NaHCO3 water types in non-CSG environments suggest that these characteristic major ion relationships described here can: i) serve as an indicator of potential CSG groundwaters in certain coal-bearing aquifers that contain methane; and ii) help in the development of strategic sampling programmes for CSG exploration and to monitor potential impacts of CSG activities on groundwater resources.
Resumo:
The present challenge in drug discovery is to synthesize new compounds efficiently in minimal time. The trend is towards carefully designed and well-characterized compound libraries because fast and effective synthesis methods easily produce thousands of new compounds. The need for rapid and reliable analysis methods is increased at the same time. Quality assessment, including the identification and purity tests, is highly important since false (negative or positive) results, for instance in tests of biological activity or determination of early-ADME parameters in vitro (the pharmacokinetic study of drug absorption, distribution, metabolism, and excretion), must be avoided. This thesis summarizes the principles of classical planar chromatographic separation combined with ultraviolet (UV) and mass spectrometric (MS) detection, and introduces powerful, rapid, easy, low-cost, and alternative tools and techniques for qualitative and quantitative analysis of small drug or drug-like molecules. High performance thin-layer chromatography (HPTLC) was introduced and evaluated for fast semi-quantitative assessment of the purity of synthesis target compounds. HPTLC methods were compared with the liquid chromatography (LC) methods. Electrospray ionization mass spectrometry (ESI MS) and atmospheric pressure matrix-assisted laser desorption/ionization MS (AP MALDI MS) were used to identify and confirm the product zones on the plate. AP MALDI MS was rapid, and easy to carry out directly on the plate without scraping. The PLC method was used to isolate target compounds from crude synthesized products and purify them for bioactivity and preliminary ADME tests. Ultra-thin-layer chromatography (UTLC) with AP MALDI MS and desorption electrospray ionization mass spectrometry (DESI MS) was introduced and studied for the first time. Because of the thinner adsorbent layer, the monolithic UTLC plate provided 10 100 times better sensitivity in MALDI analysis than did HPTLC plates. The limits of detection (LODs) down to low picomole range were demonstrated for UTLC AP MALDI and UTLC DESI MS. In a comparison of AP and vacuum MALDI MS detection for UTLC plates, desorption from the irregular surface of the plates with the combination of an external AP MALDI ion source and an ion trap instrument provided clearly less variation in mass accuracy than the vacuum MALDI time-of-flight (TOF) instrument. The performance of the two-dimensional (2D) UTLC separation with AP MALDI MS method was studied for the first time. The influence of the urine matrix on the separation and the repeatability was evaluated with benzodiazepines as model substances in human urine. The applicability of 2D UTLC AP MALDI MS was demonstrated in the detection of metabolites in an authentic urine sample.
Resumo:
Indium-tin oxide films have been deposited by reactive electron beam evaporation of ln+Sn alloy both in neutral and ionized oxygen environments. A low-energy ion source (fabricated in-house) has been used. Films deposited with neutral oxygen exhibited very low optical transmittance (5% at 550 nm). Highly transparent (85%) and low-resistivity (5 X 10(-4) Omega cm) films have been deposited in ionized oxygen at ambient substrate temperature. Optical and electrical properties of the films have been studied as a function of deposition parameters. (C) 2002 Society of Photo-Optical Instrumentation Engineers.
Resumo:
测量了End-Hall离子源在不同条件下的离子束流密度,在不同离子束流密度下进行了心离子辅助沉积ZrO2薄膜的实验,研究了离子束流密度对薄膜折射率、晶相的影响.根据动量传递模型分析了离子束流密度对薄膜折射率的作用;根据热尖峰理论证明了一定条件下离子束流密度不会影响薄膜晶体结构。
Resumo:
多层介质反射镜在非正入射的时候,两个不同的偏振态之间会产生不同的相移.根据空气与膜层、膜层之间的实际情况,建立了界面层和表面吸附层模型,并运用它分析相位延迟产生误差的原因.通过优化设计,入射角为54°,在1285~1345nm之间p,s波获得了270±1°的相移,同时也使反射率在99.5%以上.用离子束溅射技术制备相位延迟膜,用分光光度计测试了光谱特性和用椭偏仪测试了相位特性,在相应波段获得了262.4±1.8°的相移,同时也使反射率在99.6%以上.误差的主要来源是离子源工作特性会产生不均匀的过渡层和最
Resumo:
多层介质反射镜在非正入射的时候,两个不同的偏振态之间会产生不同的相移。利用矩阵法,根据菲涅耳公式和电磁场边界条件,推导出p,s波的相移。通过优化设计.入射角为54°,在1285~1345nm之间p,s波获得了270°±1°的相移,同时也使反射率在99.5%以上。用离子束溅射技术制备相位延迟膜,用分光光度计测试了光谱特性和用椭偏仪测试了相位特性,在相应波段获得了262.4°±1.8°的相移,同时也使反射率在99.6%以上。误差的主要来源是离子源工作特性会产生不均匀的过渡层和最外层会吸收一些水气、灰尘等也产生
Resumo:
We have fabricated surface plasmon modulated nano-aperture vertical-cavity surface-emitting lasers (VCSELs) from common 850 nm VCSELs using focus ion beam etching with Ga+ ion source. The far-field output power is about 0.3 mW at a driving current of 15 mA with a sub-wavelength aperture surrounded by concentric periodic grooves. The enhancement of transmission intensity can be explained by diffraction and enhanced fields associated with surface plasmon. This structure also exhibits beaming properties.
Resumo:
Helicon plasma source is known as an efficient generator of uniform and high density plasma. A helicon plasma source was developed for the investigation of plasma striping and plasma lens at the Institute of Modern Physics, CAS. In this paper, the characteristics of helicon plasma have been studied by using Langmuir four-probe and a high plasma density up to 3.9×1013 /cm3 has been achieved with the Nagoya type III antenna. In the experiment, several important phenomena have been found: (1) for a given magnetic induction intensity, the plasma density became greater with the increase of RF power; (2) the helicon mode appeared at the RF power between 300 W and 400 W; (3) the plasma density gradually tended to saturation as the RF power increased to the higher power; (4) a higher plasma density can be obtained by a good matching between the RF power and the magnetic field distribution. The key issue is how to optimize the matching between the RF power and the magnetic field. Moreover, some tests on the extraction of ion beam were performed, and the preliminary results were given. The problems which existed in the helicon ion source will be discussed and the increase in beam density will be expected by extraction system optimum.