952 resultados para correlation coefficient


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study aimed to assess the reliability of intra and inter-examiner subacromial impingement index (SII) measures obtained from radiographs. Thirty-six individuals were enrolled and divided into two groups: control group, composed of 18 volunteers in good general health without shoulder problems, and a group of 18 patients with subacromial impingement syndrome (SIS). Radiographic images were taken with the dominant upper limb in neutral rotation, while the volunteers held their arm at 90A degrees of abduction in the frontal plane. The beam of radiation at 30A degrees craniocaudal inclination was used to provide an antero-posterior image view. Three blinded examiners each performed three measurements from the subacromial space (SS) and the anatomical neck of the humerus (NH). The SII was calculated as the ratio of the SS and the NH measures. The mean values of SII were compared using t-tests. The intra-class correlation coefficient (ICC) was used to assess intra- and inter-examiner reliability of the measures. The mean values of SII were greater for the control group (0.12) than for the SIS group (0.08; p = 0.0071). SII measurements showed excellent intra (0.96-0.99) and inter-examiner reliability (0.94) for both the control and SIS group. The results of this study show the potential use of the SII; a greater mean value for the control group compared to the SIS group and excellent reliability for intra- and inter-examiner measurement. Validation studies of the index should be conducted to correlate the index with clinical findings from subacromial impingement syndrome.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background The aim of this study was to validate a biomagnetic method (alternate current biosusceptometry, ACB) for monitoring gastric wall contractions in rats. Methods In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed in pentobarbital-anesthetized rats with SG and magnetic markers previously implanted under the gastric serosa or after ingestion of magnetic material. Gastric motility was quantified from the tracing amplitudes and frequency profiles obtained by Fast Fourier Transform. Key Results The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation coefficient between the ACB and SG signal amplitude was higher (P < 0.0001) in the postprandial (88.3 +/- 9.1 V) than in the fasting state (31.0 +/- 16.9 V). Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation between techniques for fasting-state recordings. When a magnetic material was ingested, there was also strong correlation in the frequency and signal amplitude and a small phase-difference between the techniques. The contraction frequencies using ACB were 0.068 +/- 0.007 Hz (postprandial) and 0.058 +/- 0.007 Hz (fasting) (P < 0.002) and those using SG were 0.066 +/- 0.006 Hz (postprandial) and 0.059 +/- 0.008 Hz (fasting) (P < 0.005). Conclusions & Inferences In summary, ACB is reliable for monitoring gastric wall contractions using both implanted and ingested magnetic materials, and may serve as an accurate and sensitive technique for gastrointestinal motility studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study investigated morpho-functional relations of the aortic depressor nerve (ADN) 5, 15 and 120 days after the onset of streptozotocin-induced diabetes in rats. Time control animals received vehicle. Under pentobarbital anesthesia, ADN activity was recorded simultaneously with arterial pressure. After the recordings, nerves were prepared for light microscopy study and morphometry. ADN function was accessed by means of pressure-nerve activity curve (fitted by sigmoidal regression) and cross-spectral analysis between mean arterial pressure (MAP) and ADN activity. The relation between morphological (myelinated fibers number and density, total myelin area, total fiber area and percentage of occupancy) and functional (gain, signal/noise relation, frequency) parameters were accessed by linear regression analysis and correlation coefficient calculations. Functional parameters obtained by means of the sigmoidal regression curve as well as by cross-spectral analysis were similar in diabetic and control rats. Morphometric parameters of the ADN were similar between groups 5 days after the onset of diabetes. Average myelin area and myelinated fiber area were significantly smaller on diabetic rats 15 and 120 days after the onset of diabetes, being the myelinated fiber and respective axons area and diameter also smaller on 120 days group. Nevertheless, G ratio (ratio between axon and fiber diameter) was nearly 0.6 and not different between groups or experimental times. No significant relationship between morphological and functional parameters was detected in all experimental groups. The present study suggests that ADN diabetic neuropathy was time-dependent, with damage to myelinated fibers to be the primary event, not evidenced by physiological methods. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective. Endothelial impairment evaluation by sonographic measurement of flow-mediated dilatation (FMD) has become broadly used. However, this method has 2 main caveats: the dilatation depends on the baseline arterial diameter, and a high precision level is required. Vasodilatation leads to an amplified fall in impedance. We hypothesized that assessment of the pulsatility index change (PI-C) 1 minute after 5-minute forearm compression might evaluate that fall in impedance. The aim of this study was to compare the PI-C with FMD. Methods. Flow-mediated dilatation and the PI-C were assessed in 51 healthy women aged between 35.1 and 67.1 years. We correlated both FMD and the PI-C with age, body mass index, waist circumference, cholesterol level, high-density lipoprotein level, glucose level, systolic and diastolic blood pressure, pulse pressure, brachial artery diameter, simplified Framingham score, intima-media thickness, and carotid stiffness index. Intraclass correlation coefficients between 2 FMD and PI-C measurements were also examined. Results. Only FMD correlated with baseline brachial diameter (r=-0.53). The PI-C had a high correlation with age, body mass index, waist circumference, cholesterol level, systolic blood pressure, pulse pressure, simplified Framingham score, and intima-media thickness. The correlation between FMD and the PI-C was high (r=-0.66). The PI-C had a higher intraclass correlation coefficient (0.991) than FMD (0.836) but not brachial artery diameter (0.989). Conclusions. The PI-C had a large correlation with various markers of cardiovascular risk. Additionally, PI-C measurement does not require offline analysis, extra software, or electrocardiography We think that the PI-C could be considered a marker of endothelial function. However, more studies are required before further conclusions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectives The methods currently available for the measurement of energy expenditure in patients, such as indirect calorimetry and double-labelled water, are expensive and are limited in Brazil to research projects. Thus, equations for the prediction of resting metabolic rate appear to be a viable alternative for clinical practice. However, there are no specific equations for the Brazilian population and few studies have been conducted on Brazilian women in the climacteric period using existing and commonly applied equations. On this basis, the objective of the present study was to investigate the concordance between the predictive equations most frequently used and indirect calorimetry for the measurement of resting metabolic rate. Methods We calculated the St. Laurent concordance correlation coefficient between the equations and resting metabolic rate calculated by indirect calorimetry in 46 climacteric women. Results The equation showing the best concordance was that of the FAO/WHO/UNU formula (0.63), which proved to be better than the Harris & Benedict equation (0.55) for the sample studied. Conclusions On the basis of the results of the present study, we conclude that the FAO/WHO/UNU formula can be used to predict better the resting metabolic rate of climacteric women. Further studies using more homogeneous and larger samples are needed to permit the use of the FAO/WHO/UNU formula for this population group with greater accuracy.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: This study was aimed at assessing the psychometric qualities of the abbreviated versions of the Alcohol Use Disorders Identification Test (AUDIT-3, AUDIT-4, AUDIT-C, AUDIT-PC, AUDIT-QF, FAST, and Five-Shot) and at comparing them to the 10-item AUDIT and the CAGE in 2 samples of Brazilian adults. Methods: The validity and internal consistency of the scales were assessed in a sample of 530 subjects attended at an emergency department and at a Psychosocial Care Center for Alcohol and Drugs. The Structured Clinical Interview for DSM-IV was used as the diagnostic comparative measure for the predictive validity assessment. The concurrent validity between the scales was analyzed by means of Pearson`s correlation coefficient. Results: The assessment of the predictive validity of the abbreviated versions showed high sensitivity (of 0.78 to 0.96) and specificity (of 0.74 to 0.94) indices, with areas under the curve as elevated as those of the AUDIT (0.89 and 0.92 to screen for abuse and 0.93 and 0.95 in the screening of dependence). The CAGE presented lower indices: 0.81 for abuse and 0.87 for dependence. The analysis of the internal consistency of the AUDIT and its versions exhibited Cronbach`s alpha coefficients between 0.83 and 0.94, while the coefficient for the CAGE was 0.78. Significant correlations were found between the 10-item AUDIT and its versions, ranging from 0.91 to 0.99. Again, the results for the CAGE were satisfactory (0.77), although inferior to the other instruments. Conclusions: The results obtained in this study confirm the validity of the abbreviated versions of the AUDIT for the screening of alcohol use disorders and show that their psychometric properties are as satisfactory as those of the 10-item AUDIT and the CAGE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to create an adaptation of the Revised Knox Preschool Play Scale (RKPPS) for the Brazilian population, as well as to apply the instrument with statistical analysis to verify the preliminary intra-rater and inter-rater reliability and repeatability of the instrument. The instructions presented by Beaton et al. regarding adaptation of instruments were followed to perform a cross-cultural adaptation of the RKPPS. A preliminary test of the Portuguese version was performed on 18 children with no motor, cognitive or sensory impairment. The video recordings of this administration were analysed on two separate occasions by two examiners within a 5-month interval, using the scores suggested by Pfeifer. The Spearman`s test was used in the statistical analysis of the obtained data. The author of the RKPPS agreed with the small necessary cultural adaptations. The Spearman test revealed a high correlation coefficient and good significance levels for both intra- and inter-raters values. This study demonstrated the reliability and repeatability of the Brazilian version of the RKPPS. This is a preliminary study and further studies are needed in order to validate the scale to be administered in the Brazilian population. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The mechanical alterations related to the excessive use of accessory respiratory muscles and the mouth breathing observed in children with asthma may lead to the development of alterations in head posture, shoulders, thoracic region and, consequently, in alterations of body posture. The purpose of this study was to assess body posture changes of children with asthma compared to a non-asthmatic control group matched for gender, age, weight, and height. Thirty children with asthma and 30 non-asthmatic children aged 7 to 12 years were enrolled in this study. Digital photographic records were obtained for analysis of the body posture of the children by computed photogrammetry. The intraclass correlation coefficient and Student`s t test (p < 0.05) were used for statistical analysis. There were no significant differences between groups for the angles analyzed, except for the knee flexor angle. These results demonstrate that children with asthma did not present postural alterations compared to non-asthmatic controls since the only angle for which there was a significant difference between groups showed weak reproducibility. The findings of this study do not support the notion that children with asthma present alterations in body posture.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: We aimed to validate three widely used scales in stroke research in a multiethnic Brazilian population. Methods: The National Institutes of Health Stroke Scale (NIHSS), modified Rankin Scale (mRS) and Barthel Index (BI) were translated, culturally adapted and applied by two independent investigators. The mRS was applied with or without a previously validated structured interview. Interobserver agreement (kappa statistics) and intraclass correlation coefficients were calculated. Results: 84 patients underwent mRS (56 with and 28 without a structured interview), 57 BI and 62 NIHSS scoring. Intraclass correlation coefficient was 0.902 for NIHSS and 0.967 for BI. For BI, interobserver agreement was good (kappa = 0.70). For mRS, the structured interview improved interobserver agreement (kappa = 0.34 without a structured interview; 0.75 with a structured interview). Conclusion: The NIHSS, BI and mRS show good validity when translated and culturally adapted. Using a structured interview for the mRS improves interobserver concordance rates. Copyright (C) 2008 S. Karger AG, Basel

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: In the literature there is no validated instrument for the clinical evaluation of the orofacial myofunctional condition of children that will permit the examiner to express numerically his perception of the characteristics and behaviors observed. The proposal of this study is to describe a protocol for the evaluation of children aged 6-12 years in order to establish relations between the orofacial. myofunctional conditions and numerical scales. The protocol validity, reliability of the examiners and agreement between them was analyzed. Methods: Eighty children aged 6-12 years participated in the study. All were evaluated and 30 were selected at random for the analyses (age range: 72-149 months, mean = 103.3, S.D. = 23.57). Individuals with and without orofacial myofunctional. disorders were included. The examiners were two speech therapists property calibrated in orofacial myofunctional evaluation. Two protocols were constructed. One, based on traditional models, was called traditional orofacial. myofunctional. evaluation (TOME), and the other, with the addition of numerical scales, was called orofacial myofunctional. evaluation with scores (OMES). The clinical conditions included were: appearance, posture and mobility of lips, tongue, cheeks and jaws, respiration, mastication and deglutition. Statistical analysis was performed using the split-half reliability method. Means, standard deviations and the Spearman correlation coefficient were also calculated. Results: There was a statistically significant correlation between the evaluations of 30 children assessed with the TOME and OMES protocols (r = 0.85, p < 0.01). The reliability between protocols was 0.92. The test-retest reliability of the OMES instrument was 0.99 and the correlation was 0.98. Reliability between examiners 1 and 2 using the OMES protocol was 0.99, and the correlation was 0.98 (P < 0.01). Conclusion: The OMES protocot proved to be a valid and reliable instrument for orofacial myofunctional evaluation, permitting the grading of orofacial myofunctional conditions within the limits of the selected items. (c) 2007 Elsevier Ireland Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the genetic correlations among real-time ultrasound carcass, BW, and scrotal circumference (SC) traits in Nelore cattle. Carcass traits, measured by real-time ultrasound of the live animal, were recorded from 2002 to 2004 on 10 farms across 6 Brazilian states on 2,590 males and females ranging in age from 450 to 599 d. Ultrasound records of LM area (LMA) and backfat thickness (BF) were obtained from cross-sectional images between the 12th and 13th ribs, and rump fat thickness (RF) was measured between the hook and pin bones over the junction between gluteus medius and biceps femoris muscles. Also, BW (n = 22,778) and SC ( n = 5,695) were recorded on animals born between 1998 and 2003. The BW traits were 120, 210, 365, 450, and 550-d standardized BW (W120, W210, W365, W450, and W550), plus BW (WS) and hip height (HH) on the ultrasound scanning date. The SC traits were 365-, 450-, and 550-d standardized SC (SC365, SC450, and SC550). For the BW and SC traits, the database used was from the Nelore Breeding Program-Nelore Brazil. The genetic parameters were estimated with multivariate animal models and REML. Estimated genetic correlations between LMA and other traits were 0.06 (BF), -0.04 ( RF), 0.05 (HH), 0.58 (WS), 0.53 (W120), 0.62 (W210), 0.67 (W365), 0.64 ( W450 and W550), 0.28 (SC365), 0.24 (SC450), and 0.00 ( SC550). Estimated genetic correlations between BF and with other traits were 0.74 ( RF), -0.32 (HH), 0.19 (WS), -0.03 (W120), -0.10 (W210), 0.04 (W365), 0.01 (W450), 0.06 ( W550), 0.17 (SC365 and SC450), and -0.19 (SC550). Estimated genetic correlations between RF and other traits were -0.41 (HH), -0.09 (WS), -0.13 ( W120), -0.09 ( W210), -0.01 ( W365), 0.02 (W450), 0.03 (W550), 0.05 ( SC365), 0.11 ( SC450), and -0.18 (SC550). These estimates indicate that selection for carcass traits measured by real-time ultrasound should not cause antagonism in the genetic improvement of SC and BW traits. Also, selection to increase HH might decrease subcutaneous fat as correlated response. Therefore, to obtain animals suited to specific tropical production systems, carcass, BW, and SC traits should be considered in selection programs.