A standardized measurement technique may improve the reliability of measurements of endometrial thickness and volume


Autoria(s): MARTINS, W. P.; RAINE-FENNING, N. J.; LEITE, S. P.; FERRIANI, R. A.; NASTRI, C. O.
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2011

Resumo

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Identificador

ULTRASOUND IN OBSTETRICS & GYNECOLOGY, v.38, n.1, p.107-115, 2011

0960-7692

http://producao.usp.br/handle/BDPI/24537

10.1002/uog.9016

http://dx.doi.org/10.1002/uog.9016

Idioma(s)

eng

Publicador

WILEY-BLACKWELL

Relação

Ultrasound in Obstetrics & Gynecology

Direitos

restrictedAccess

Copyright WILEY-BLACKWELL

Palavras-Chave #endometrium #imaging #reproductive medicine #standardization #three-dimensional #ultrasonography #3-DIMENSIONAL ULTRASOUND #OVARIAN STIMULATION #DETECT PREGNANCY #EMBRYO-TRANSFER #REPRODUCIBILITY #VALIDITY #AGREEMENT #INTRAOBSERVER #WOMEN #Acoustics #Obstetrics & Gynecology #Radiology, Nuclear Medicine & Medical Imaging
Tipo

article

original article

publishedVersion