Intra and inter-examiner reliability of the subacromial impingement index


Autoria(s): RAMOS, Carlos Eduardo Sala; FERREIRA, Felipe Varella; SPOSITO, Guilherme de Carvalho; NOGUEIRA-BARBOSA, Marcello Henrique; OLIVEIRA, Anamaria Siriani de
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2010

Resumo

The present study aimed to assess the reliability of intra and inter-examiner subacromial impingement index (SII) measures obtained from radiographs. Thirty-six individuals were enrolled and divided into two groups: control group, composed of 18 volunteers in good general health without shoulder problems, and a group of 18 patients with subacromial impingement syndrome (SIS). Radiographic images were taken with the dominant upper limb in neutral rotation, while the volunteers held their arm at 90A degrees of abduction in the frontal plane. The beam of radiation at 30A degrees craniocaudal inclination was used to provide an antero-posterior image view. Three blinded examiners each performed three measurements from the subacromial space (SS) and the anatomical neck of the humerus (NH). The SII was calculated as the ratio of the SS and the NH measures. The mean values of SII were compared using t-tests. The intra-class correlation coefficient (ICC) was used to assess intra- and inter-examiner reliability of the measures. The mean values of SII were greater for the control group (0.12) than for the SIS group (0.08; p = 0.0071). SII measurements showed excellent intra (0.96-0.99) and inter-examiner reliability (0.94) for both the control and SIS group. The results of this study show the potential use of the SII; a greater mean value for the control group compared to the SIS group and excellent reliability for intra- and inter-examiner measurement. Validation studies of the index should be conducted to correlate the index with clinical findings from subacromial impingement syndrome.

State of Sao Paulo Research Foundation (FAPESP)

National Council for Scientific and Technological Development (CNPq)

Identificador

SKELETAL RADIOLOGY, v.39, n.1, p.35-39, 2010

0364-2348

http://producao.usp.br/handle/BDPI/23701

10.1007/s00256-009-0790-y

http://dx.doi.org/10.1007/s00256-009-0790-y

Idioma(s)

eng

Publicador

SPRINGER

Relação

Skeletal Radiology

Direitos

restrictedAccess

Copyright SPRINGER

Palavras-Chave #Reliability #Subacromial impingement index #Radiograph #ICC #ROTATOR CUFF TEARS #CORRELATION-COEFFICIENT #SHOULDER #CLASSIFICATION #RADIOGRAPHS #SPACE #Radiology, Nuclear Medicine & Medical Imaging
Tipo

article

original article

publishedVersion