125 resultados para Ophthalmological


Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare disk halo size in response to a glare source in eyes with an aspheric apodized diffractive multifocal intraocular lens (IOL) or aspheric monofocal IOL. SETTING: Rementeria Ophthalmological Clinic, Madrid, Spain. DESIGN: Prospective randomized masked study. METHOD: Halo radius was measured using a vision monitor (MonCv3) with low-luminance optotypes in eyes that had cataract surgery and bilateral implantion of an Acrysof Restor SN6AD1 multifocal IOL or Acrysof IQ monofocal IOL 6 to 9 months previously. The visual angle subtended by the disk halo radius was calculated in minutes of arc (arcmin). Patient complaints of halo disturbances were recorded. Monocular uncorrected distance visual acutity (UDVA) and corrected distance visual acuity (CDVA) were measured using high-contrast (96%) and low-contrast (10%) logMAR letter charts. RESULTS: The study comprised 39 eyes of 39 subjects (aged 70 to 80 years); 21 eyes had a multifocal IOL and 18 eyes a monofocal IOL. The mean halo radius was 35 arcmin larger in the multifocal IOL group than the monofocal group (P<.05). Greater halo effects were reported in the multifocal IOL group (P<.05). The mean monocular high-contrast UDVA and low-contrast UDVA did not vary significantly between groups, whereas the mean monocular high-contrast CDVA and low-contrast CDVA were significantly worse at 0.12 logMAR and 0.13 logMAR in the multifocal than in the monofocal IOL group, respectively (P <.01). A significant positive correlation was detected by multiple linear regression between the halo radius and low-contrast UDVA in the multifocal IOL group (r = 0.72, P<.001). CONCLUSIONS: The diffractive multifocal IOL gave rise to a larger disk halo size, which was correlated with a worse low-contrast UDVA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Roman seals associated with collyria (Latin expression for eye drops /washes and lotions for eye maintenance) provide valuable information about eye care in the antiquity. These small, usually stone-made pieces bore engravings with the names of eye doctors and also the collyria used to treat an eye disease. The collyria seals have been found all over the Roman empire and Celtic territories in particular and were usually associated with military camps. In Hispania (Iberian Peninsula), only three collyria seals have been found. These findings speak about eye care in this ancient Roman province as well as about of the life of the time. This article takes a look at the utility and social significance of the collyria seals and seeks to give an insight in the ophthalmological practice of in the Roman Empire.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the visual and refractive outcomes after phacoemulsification surgery in eyes with isolated lens coloboma. Design: Prospective, consecutive case series. Participants: Eighteen eyes with isolated lens coloboma of 13 patients were included in the study. Mean patient age was 13.9 ± 6.5 years. Methods: Patients underwent phacoemulsification surgery, with combined implantation of capsular tension ring (CTR) and intraocular lens. In colobomas of less than 120°, a CTR was used, whereas in colobomas of more than 120°, a Cionni-modified single eyelet CTR was used to achieve better capsular centration. The main outcome measures were uncorrected distance visual acuity, corrected distance visual acuity, refraction, and keratometry. Results: Mean logMAR uncorrected distance visual acuity and corrected distance visual acuity improved significantly from 1.53 ± 0.35 and 1.02 ± 0.47 before surgery to 0.67 ± 0.51 and 0.52 ± 0.49 at the last visit of the follow-up (p < 0.001). Mean refractive cylinder and spherical equivalent decreased significantly from –6.73 ± 1.73 and –6.72 ± 4.07 D preoperatively to –1.40 ± 1.39 and –0.83 ± 1.31 D at the end of the follow-up (p = 0.001 and p = 0.01, respectively). Mean keratometric astigmatism at preoperative and postoperative visits were 1.58 ± 0.97 and 1.65 ± 0.94 D, respectively (p = 0.70). Conclusions: Phacoemulsification with CTR and intraocular lens implantation is an effective and safe option for providing a refractive correction and a significant visual improvement in eyes with isolated lens coloboma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To evaluate the usefulness of microperimetry in the early detection of the ocular anomalies associated with the use of hydroxychloroquine. Methods. Prospective comparative case series study comprising 14 healthy eyes of 7 patients (group A) and 14 eyes of 7 patients under treatment with hydroxychloroquine for the treatment of rheumatologic diseases and without fundoscopic or perimetric anomalies (group B). A comprehensive ophthalmological examination including microperimetry (MP) and spectraldomain optical coherence tomography was performed in both groups. Results. No significant differences were found in mean MP foveal sensitivity between groups (P = 0.18). However, mean MP overall sensitivity was significantly higher in group A (29.05 ± 0.57 dB versus group B, 26.05 ± 2.75 dB; P < 0.001). Significantly higher sensitivity values were obtained in group A in comparison to group B for the three eccentric loci evaluated (P < 0.001). Conclusion. Microperimetry seems to be a useful tool for the early detection of retinal damage in patients treated with hydroxychloroquine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To assess the usefulness of microperimetry (MP) as an additional objective method for characterizing the fixation pattern in nystagmus. Design: Prospective study. Participants: Fifteen eyes of 8 subjects (age, 12–80 years) with nystagmus from the Lluís Alcanyís Foundation (University of Valencia, Spain) were included. Methods: All patients had a comprehensive ophthalmologic examination including a microperimetric examination (MAIA, CenterVue, Padova, Italy). The following microperimetric parameters were evaluated: average threshold (AT), macular integrity index (MI), fixating points within a circle of 1° (P1) and 2° of radius (P2), bivariate contour ellipse area (BCEA) considering 63% and 95% of fixating points, and horizontal and vertical axes of that ellipse. Results: In monocular conditions, 6 eyes showed a fixation classified as stable, 6 eyes showed a relatively unstable fixation, and 3 eyes showed an unstable fixation. Statistically significant differences were found between the horizontal and vertical components of movement (p = 0.001), as well as in their ranges (p < 0.001). Intereye comparison showed differences between eyes in some subjects, but only statistically significant differences were found in the fixation coordinates X and Y (p < 0.001). No significant intereye differences were found between microperimetric parameters. Between monocular and binocular conditions, statistically significant differences in the X and Y coordinates were found in all eyes (p < 0.02) except one. No significant differences were found between MP parameters for monocular or binocular conditions. Strong correlations of corrected distance visual acuity (CDVA) with AT (r = 0.812, p = 0.014), MI (r = –0.812, p = 0.014), P1 (r = 0.729, p = 0.002), horizontal diameter of BCEA (r = –0.700, p = 0.004), and X range (r = –0.722, p = 0.005) were found. Conclusions: MP seems to be a useful technology for the characterization of the fixation pattern in nystagmus, which seems to be related to the level of visual acuity achieved by the patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Title also romanized as: Nihon Ganka Gakkai zasshi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the clinical and ophthalmological findings in two infants with neonatal Marfan syndrome (nMFS) and primary trabeculodysgenesis (PT). Fibrillin 1 (FBN1) mutations were confirmed in both cases. Numerous eye anomalies have been recognized in infants with nMFS, but PT has not been reported previously. Our report expands the phenotype of nMFS, and highlights the importance of early and careful ophthalmological assessment of these infants. (C) 2004 Wiley-Liss, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The binocular Esterman visual field test (EVFT) is the current visual field test for driving in the UK. Merging of monocular field tests (Integrated Visual Field, IVF) has been proposed as an alternative for glaucoma patients. Aims: To examine the level of agreement between the EVFT and IVF for patients with binocular paracentral scotomata, caused by either ophthalmological or neurological conditions, and to compare outcomes with useful field of view (UFOV) performance, a test of visual attention thought to be important in driving. Methods: 60 patients with binocular paracentral scotomata but normal visual acuity (VA) were recruited prospectively. Subjects completed and were classified as “pass” or “fail” for the EVFT, IVF and UFOV. Results: Good agreement occurred between the EVFT and IVF in classifying subjects as “pass” or “fail” (kappa?=?0.84). Classifications disagreed for four subjects with paracentral scotomata of neurological origin (three “passed” IVF yet “failed” EVFT). Mean UFOV scores did not differ between those who “passed” and those who “failed” both visual field tests (p?=?0.11). Agreement between the visual field tests and UFOV was limited (EVFT kappa?=?0.22, IVF kappa 0.32). Conclusions: Although the IVF and EVFT agree well in classifying visual fields with regard to legal fitness to drive in the UK, the IVF “passes” some individuals currently classed as unfit to drive due to paracentral scotomata of non-glaucomatous origin. The suitability of the UFOV for assessing crash risk in those with visual field loss is questionable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

DESIGN. Retrospective analysis PURPOSE. Macular oedema is not directly visible on two dimensional digital photographs such that surrogate markers need to be used. In the English National Screening Programme these are exudate within one optic disc diameter (DD) of the fovea, group of exudates within two DD of the fovea and haemorrhages or microaneurysms (HMA) within one DD of the fovea with best corrected visual acuity (VA) worse than 6/9. All patients who present with any of these surrogate markers at screening are referred to an ophthalmology clinic for slit lamp examination. The purpose of this audit was to determine how many patients with positive maculopathy diagnosis on photography were truly identified by optical coherence tomography (OCT) with macular oedema. METHODS. Data was collected from patients attending digital diabetic retinopathy screening. Patients who presented with surrogate markers for macular oedema also had an OCT scan. The fast macula scan on the Stratus OCT was used and an ophthalmologist reviewed the scans to determine whether macular oedema was present. RESULTS. Maculopathy by exudates: Of 155 patients 45 (29%) showed thickening on the OCT of these 12 required laser. Those who also had pre-proliferative retinopathy (n=20) were more likely to have macular oedema (75%) than those with background diabetic retinopathy. Maculopathy by HMA and VA worse than 6/9: Of 66 patients 11 (16.7%) showed thickening on the OCT. 5 (7.6%) of these had macular oedema, 5 (7.6%) epi-retinal membrane, and 1 (1.5%) age related macular degeneration. None of these patients required laser. CONCLUSIONS. The likelihood of the presence of macular oedema and requiring laser treatment is greater with macular exudation than HMA within one DD and reduced VA. Overall the surrogate markers used show low specificity for macular oedema, however combining OCT with photography does identify those with macular oedema who require a true referral for an ophthalmological slit lamp examination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Ocular allergies frequently present in pharmacy practices. However, research into the actual management of ocular allergy in pharmacies is lacking. Objective To determine and quantify history and symptom questioning of a patient with presumed allergic conjunctivitis and management strategies employed by pharmacy staff in the UK. Method A mystery shopper technique was used to simulate an episode of allergic conjunctivitis in 100 community pharmacies across the UK. Results The mean number of questions asked by pharmacy staff to the patient was 3.5 ± 2.6, with a range of 0-10. The most common question was whether the patient had a history of allergies (45 %).Ninety-one percent advised on treatment, with the remaining 9 % directly referring to the patient's general practitioner (n = 4) or pharmacist(n = 4), but only two to their optometrist. The most common treatment suggested was sodium cromoglycate 2 % (50 %). However, many pharmacies advising treatment did not ask the patient's age (37 %), if they wore contact lenses (43 %), or gave dosage advice (43 %). Only 5 % of pharmacies advised follow up and 14 % suggested visiting a general practitioner and 1 % an optometrist if symptoms did not resolve with treatment. Conclusion There is a need for improved ophthalmological training for pharmacy staff with respect to the management of allergic conjunctivitis. © Springer Science+Business Media Dordrecht 2012.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose - To investigate the ability of pharmacy staff in the United Kingdom (UK) to diagnose and treat dry eye. Methods - A mystery shopper technique to simulate a patient with presumed dry eye was used in 50 pharmacy practices in major towns and cities across the UK. Pharmacies were unaware of their involvement in the study. With the exception of a predetermined opening statement to initiate the consultation, no further information was volunteered. Questions asked, diagnoses given, management strategy advised and staff type was recorded immediately after the consultation. Results - The mean number of questions was 4.5 (SD 1.7; range 1–10). The most common question was the duration of symptoms (56%) and the least common was whether the patient had a history of headaches (2%). All pharmacy staff gave a diagnosis, but the majority were incorrect (58%), with only 42% correctly identifying dry eye. Treatment was advised by 92% of pharmacy staff, with the remaining 8% advising referral directly to the patient's GP or optometrist. Dry eye treatments involved topical ocular lubrication via eye drops (90%) and lipid based sprays (10%). However, only 10% gave administration advice, 10% gave dosage advice, 9% asked about contact lens wear, and none offered follow up although 15% also advised GP or optometrist referral. Conclusions - There is a need for improved ophthalmological training amongst pharmacists and pharmacy staff and establishment of cross referral relationships between pharmacies and optometry practices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Premium Intraocular Lenses (IOLs) such as toric IOLs, multifocal IOLs (MIOLs) and accommodating IOLs (AIOLs) can provide better refractive and visual outcomes compared to standard monofocal designs, leading to greater levels of post-operative spectacle independence. The principal theme of this thesis relates to the development of new assessment techniques that can help to improve future premium IOL design. IOLs designed to correct astigmatism form the focus of the first part of the thesis. A novel toric IOL design was devised to decrease the effect of toric rotation on patient visual acuity, but found to have neither a beneficial or detrimental impact on visual acuity retention. IOL tilt, like rotation, may curtail visual performance; however current IOL tilt measurement techniques require the use of specialist equipment not readily available in most ophthalmological clinics. Thus a new idea that applied Pythagoras’s theory to digital images of IOL optic symmetricality in order to calculate tilt was proposed, and shown to be both accurate and highly repeatable. A literature review revealed little information on the relationship between IOL tilt, decentration and rotation and so this was examined. A poor correlation between these factors was found, indicating they occur independently of each other. Next, presbyopia correcting IOLs were investigated. The light distribution of different MIOLs and an AIOL was assessed using perimetry, to establish whether this could be used to inform optimal IOL design. Anticipated differences in threshold sensitivity between IOLs were not however found, thus perimetry was concluded to be ineffective in mapping retinal projection of blur. The observed difference between subjective and objective measures of accommodation, arising from the influence of pseudoaccommodative factors, was explored next to establish how much additional objective power would be required to restore the eye’s focus with AIOLs. Blur tolerance was found to be the key contributor to the ocular depth of focus, with an approximate dioptric influence of 0.60D. Our understanding of MIOLs may be limited by the need for subjective defocus curves, which are lengthy and do not permit important additional measures to be undertaken. The use of aberrometry to provide faster objective defocus curves was examined. Although subjective and objective measures related well, the peaks of the MIOL defocus curve profile were not evident with objective prediction of acuity, indicating a need for further refinement of visual quality metrics based on ocular aberrations. The experiments detailed in the thesis evaluate methods to improve visual performance with toric IOLs. They also investigate new techniques to allow more rapid post-operative assessment of premium IOLs, which could allow greater insights to be obtained into several aspects of visual quality, in order to optimise future IOL design and ultimately enhance patient satisfaction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. A 4 year retrospective follow up of 996 patients who pre-sented with no DR and 500 with background DR at baseline digital DR screening in 2006. Purpose. To evaluate the safety of increasing screening intervals in patients with no diabetic retinopathy (DR) or with background DR.Methods. A 4 year retrospective follow up of 996 patients who presented with no DR and 500 with background DR at baseline digital DR screening in 2006.results. Background DR Group: Of the 500 subjects that had back-ground DR in 2006, 231 were referred for DR, with an average DR routine referral rate of 12% (46 subjects) per year. nodrgrouP. Of the 996 patients who had no DR at baseline, 51 were referred over the 4 years for sight threatening DR (STDR), of these 45 patients have definite STDR confirmed by ophthalmological examination. 78% of these had type 2 diabetes and mean age at referral was 60 years (25-87). Mean diabetes duration was 10.7 years (3-32), with a mean HbA1c of 7.8% (5.7-11.3%). Eight patients (0.9%) were referred in the first year, 9 (0.9%) in the second year, 19 (1.9%) in the third year and 15 (1.5%) in the fourth year. 86% of referrals were for maculopathy, and all had observable retinopathy and none required ophthalmology clinic assessment or laser treatment.If biannual screening was adopted for patients with no DR at baseline, allowing for patients who subsequently develop background DR and would then revert to annual screening, a total of 7 (0.7%) patients would not have been appropriately referred for STDR and would have waited a further year for identification. None of the 51 referrals across the 4 years required laser treatment apart from just one patient who developed PDR in year 4 (2010) and had background since 2007.conclusIons. It could be recommended that it is safe to screen pa-tients with no DR biannually due to the low risk of developing STDR. However, patients who present with background DR should continue to be screened annually as there is a significant proportion developing STDR and would not be identified at an appropriate screening interval.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To determine the prevalence of ocular findings of the external structures and anterior segment of the eye, detected by biomicroscopic examination in schoolchildren in Natal (RN) - Brazil. Methods: After previous random selection, 1,024 pupils from elementary and secondary public and private schools in the city of Natal were evaluated from March to June 2001. All were submitted to preestablished standard research norms, consisting of identification, demographic information, ophthalmologic biomicroscopic examination, with slit lamp, performed by ophthalmologists from the “Onofre Lopes” University Hospital. Results: Alterations of the conjunctival and palpebral conditions were the most prevalent (10.4% and 6.2% respectively). Follicles (4.2%) and papillae (3.0%) were the frequent conjunctival lesions, while blepharitis (3.5%) and meibomitis (1.1%) were the most detected abnormalities in the eyelids. Upon examining the cornea, iris, lens and anterior vitreous, the most encountered findings were nubecula (0.5%), papillary membrane reliquiae (0.5%), posterior capsula opacity (0.8%) and hyaloid arteria reliquiae (2.0%). Conclusion: The most prevalent findings affecting the external structures of the eye such as eyelids and conjunctiva, consisted of blepharitis followed by follicular reaction of the conjunctiva. The most prevalent abnormalities in the cornea, iris, lens and anterior vitreous were nubecula, papillary membrane reliquiae, posterior capsular opacity and hyaloid arteria reliquiae, in that order