Fixation pattern analysis with microperimetry in nystagmus patients


Autoria(s): Molina-Martín, Ainhoa; Piñero, David P.; Pérez Cambrodí, Rafael J.
Contribuinte(s)

Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía

Grupo de Óptica y Percepción Visual (GOPV)

Data(s)

01/03/2016

01/03/2016

01/12/2015

Resumo

Objective: To assess the usefulness of microperimetry (MP) as an additional objective method for characterizing the fixation pattern in nystagmus. Design: Prospective study. Participants: Fifteen eyes of 8 subjects (age, 12–80 years) with nystagmus from the Lluís Alcanyís Foundation (University of Valencia, Spain) were included. Methods: All patients had a comprehensive ophthalmologic examination including a microperimetric examination (MAIA, CenterVue, Padova, Italy). The following microperimetric parameters were evaluated: average threshold (AT), macular integrity index (MI), fixating points within a circle of 1° (P1) and 2° of radius (P2), bivariate contour ellipse area (BCEA) considering 63% and 95% of fixating points, and horizontal and vertical axes of that ellipse. Results: In monocular conditions, 6 eyes showed a fixation classified as stable, 6 eyes showed a relatively unstable fixation, and 3 eyes showed an unstable fixation. Statistically significant differences were found between the horizontal and vertical components of movement (p = 0.001), as well as in their ranges (p < 0.001). Intereye comparison showed differences between eyes in some subjects, but only statistically significant differences were found in the fixation coordinates X and Y (p < 0.001). No significant intereye differences were found between microperimetric parameters. Between monocular and binocular conditions, statistically significant differences in the X and Y coordinates were found in all eyes (p < 0.02) except one. No significant differences were found between MP parameters for monocular or binocular conditions. Strong correlations of corrected distance visual acuity (CDVA) with AT (r = 0.812, p = 0.014), MI (r = –0.812, p = 0.014), P1 (r = 0.729, p = 0.002), horizontal diameter of BCEA (r = –0.700, p = 0.004), and X range (r = –0.722, p = 0.005) were found. Conclusions: MP seems to be a useful technology for the characterization of the fixation pattern in nystagmus, which seems to be related to the level of visual acuity achieved by the patient.

Identificador

Canadian Journal of Ophthalmology. 2015, 50(6): 413-421. doi:10.1016/j.jcjo.2015.07.012

0008-4182 (Print)

1715-3360 (Online)

http://hdl.handle.net/10045/53455

10.1016/j.jcjo.2015.07.012

Idioma(s)

eng

Publicador

Elsevier

Relação

http://dx.doi.org/10.1016/j.jcjo.2015.07.012

Direitos

© 2015 Canadian Ophthalmological Society. Published by Elsevier Inc.

info:eu-repo/semantics/restrictedAccess

Palavras-Chave #Microperimetry #Fixation pattern #Nystagmus #Óptica
Tipo

info:eu-repo/semantics/article