987 resultados para Non-rigid registration


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A statistical data analysis methodology was developed to evaluate the field emission properties of many samples of copper oxide nanostructured field emitters. This analysis was largely done in terms of Seppen-Katamuki (SK) charts, field strength and emission current. Some physical and mathematical models were derived to describe the effect of small electric field perturbations in the Fowler-Nordheim (F-N) equation, and then to explain the trend of the data represented in the SK charts. The field enhancement factor and the emission area parameters showed to be very sensitive to variations in the electric field for most of the samples. We have found that the anode-cathode distance is critical in the field emission characterization of samples having a non-rigid nanostructure. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We extend the renormalization operator introduced in [A. de Carvalho, M. Martens and M. Lyubich. Renormalization in the Henon family, I: universality but non-rigidity. J. Stat. Phys. 121(5/6) (2005), 611-669] from period-doubling Henon-like maps to Henon-like maps with arbitrary stationary combinatorics. We show that the renonnalization picture also holds in this case if the maps are taken to be strongly dissipative. We study infinitely renormalizable maps F and show that they have an invariant Cantor set O on which F acts like a p-adic adding machine for some p > 1. We then show, as for the period-doubling case in the work of de Carvalho, Martens and Lyubich [Renormalization in the Henon family, I: universality but non-rigidity. J. Stat. Phys. 121(5/6) (2005), 611-669], that the sequence of renormalizations has a universal form, but that the invariant Cantor set O is non-rigid. We also show that O cannot possess a continuous invariant line field.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Finite element (FE) modelling techniques have become a popular tool for exploring welding and clamping sequence dependence in sheet metal assemblies. In the current paper, the dimensional variability associated with different assembly clamping sequences is investigated with a FE contact modelling approach implemented in the commercial code Abaqus. A simplified channel section assembly consisting of a top hat and bottom plate is the case study investigated. Expected variation modes of bow and twist were used to simulate key variability sources in the main structural component under investigation; the top hat of the channel section. It was found that final assembly variability can change considerably depending on clamp sequence selection. It was also found that different clamp sequences can control particular modes of variation better than others, and that there is not one particular clamping sequence that is the best for containing all variation modes. An adaptable assembly process is therefore suggested, where given the shape of input components the best available clamping sequence is selected. Comparison of the performance of the proposed adaptable clamping sequence to traditional fixed clamping sequences shows improvements for the dimensional control of variability in non-rigid components. While introducing such a method in production would require inspection of each component being assembled and investigation of the alternative clamping sequences, given access to fast and detailed dimensional inspection technology such as optical coordinate measuring machines (OCMM's), the approach shows promise for future application.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Toddlers were observed as they freely explored different 'falling-off' places on a visual cliff. Toddlers played extensively with wet / non-rigid surfaces (e.g. water) and briefly explored dry / rigid surfaces. Edges were crossed intentionally and unintentionally, either as an extension or consequence of edge engagement, by a sub-group of toddlers. The findings have implications for drowning / injury prevention.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Haptic information, provided by a non-rigid tool (i.e., an anchor system), can reduce body sway in individuals who perform a standing postural task. However, it was not known whether or not continuous use of the anchor system would improve postural control after its removal. Additionally, it was unclear as to whether or not frequency of use of the anchor system is related to improved control in older adults. The present study evaluated the effect of the prolonged use of the anchor system on postural control in healthy older individuals, at different frequencies of use, while they performed a postural control task (semi-tandem position). Participants were divided into three groups according to the frequency of the anchor system's use (0%, 50%, and 100%). Pre-practice phase (without anchor) was followed by a practice phase (they used the anchor system at the predefined frequency), and a post-practice phase (immediate and late-without anchor). All three groups showed a persistent effect 15. min after the end of the practice phase (immediate post-practice phase). However, only the 50% group showed a persistent effect in the late post-practice phase (24. h after finishing the practice phase). Older adults can improve their postural control by practicing the standing postural task, and use of the anchor system limited to half of their practice time can provide additional improvement in their postural control. © 2013 Elsevier B.V.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sports biomechanics describes human movement from a performance enhancement and an injury reduction perspective. In this respect, the purpose of sports scientists is to support coaches and physicians with reliable information about athletes’ technique. The lack of methods allowing for in-field athlete evaluation as well as for accurate joint force estimates represents, to date, the main limitation to this purpose. The investigations illustrated in the present thesis aimed at providing a contribution towards the development of the above mentioned methods. Two complementary approaches were adopted: a Low Resolution Approach – related to performance assessment – where the use of wearable inertial measurement units is exploited during different phases of sprint running, and a High Resolution Approach – related to joint kinetics estimate for injury prevention – where subject-specific, non-rigid constraints for knee joint kinematic modelling used in multi-body optimization techniques are defined. Results obtained using the Low Resolution Approach indicated that, due to their portability and inexpensiveness, inertial measurement systems are a valid alternative to laboratory-based instrumentation for in-field performance evaluation of sprint running. Using acceleration and angular velocity data, the following quantities were estimated: trunk inclination and angular velocity, instantaneous horizontal velocity and displacement of a point approximating the centre of mass, and stride and support phase durations. As concerns the High Resolution Approach, results indicated that the length of the anterior cruciate and lateral collateral ligaments decreased, while that of the deep bundle of the medial collateral ligament increased significantly during flexion. Variations of the posterior cruciate and the superficial bundle of the medial collateral ligament lengths were concealed by the experimental indeterminacy. A mathematical model was provided that allowed the estimate of subject-specific ligament lengths as a function of knee flexion and that can be integrated in a multi-body optimization procedure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In 3D human movement analysis performed using stereophotogrammetric systems and skin markers, bone pose can only be estimated in an indirect fashion. During a movement, soft tissue deformations make the markers move with respect to the underlying bone generating soft tissue artefact (STA). STA has devastating effects on bone pose estimation and its compensation remains an open question. The aim of this PhD thesis was to contribute to the solution of this crucial issue. Modelling STA using measurable trial-specific variables is a fundamental prerequisite for its removal from marker trajectories. Two STA model architectures are proposed. Initially, a thigh marker-level artefact model is presented. STA was modelled as a linear combination of joint angles involved in the movement. This model was calibrated using ex-vivo and in-vivo STA invasive measures. The considerable number of model parameters led to defining STA approximations. Three definitions were proposed to represent STA as a series of modes: individual marker displacements, marker-cluster geometrical transformations (MCGT), and skin envelope shape variations. Modes were selected using two criteria: one based on modal energy and another on the selection of modes chosen a priori. The MCGT allows to select either rigid or non-rigid STA components. It was also empirically demonstrated that only the rigid component affects joint kinematics, regardless of the non-rigid amplitude. Therefore, a model of thigh and shank STA rigid component at cluster-level was then defined. An acceptable trade-off between STA compensation effectiveness and number of parameters can be obtained, improving joint kinematics accuracy. The obtained results lead to two main potential applications: the proposed models can generate realistic STAs for simulation purposes to compare different skeletal kinematics estimators; and, more importantly, focusing only on the STA rigid component, the model attains a satisfactory STA reconstruction with less parameters, facilitating its incorporation in an pose estimator.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The sleep-wake disorder narcolepsy with cataplexy is associated with the loss of hypocretin-(orexin-) producing neurons in the lateral hypothalamus. Several studies have reported abnormal cerebral activation in patients with narcolepsy with cataplexy. It remains unclear, however, whether these functional changes are related to structural alterations, particularly at the cortical level. To quantify structural brain changes associated with narcolepsy with cataplexy, we used high-resolution T1-weighted magnetic resonance imaging (MRI) in 12 patients compared with 12 healthy participants matched for age and gender. Subcortical and regional cortical volumes were measured using a method unbiased by non-linear registration. Further whole-brain analyses were conducted, measuring cortical characteristics, such as cortical thickness and gyrification, at thousands of points across each hemisphere using validated algorithms. Statistical analyses accounted for an effect of age and gender. We observed decreased cortical volume in the left paracentral lobule and increased cortical volume in the left caudal part of the middle frontal gyrus in narcoleptic patients compared with controls. Cortical thickness in prefrontal areas was inversely correlated with the severity of narcolepsy. Further, we observed several clusters of cortical thinning in patients with childhood or adolescent onset of narcolepsy compared with patients with adult onset of the disease. Our results suggest that specific anatomical changes may differentiate subgroups of narcolepsy patients with different clinical profiles (such as varying symptom severity or different age at onset). Future studies with larger groups of sleepy patients are required to assess whether distinct patterns of anatomical changes may distinguish narcolepsy from non-hypocretin-deficient hypersomnia disorders.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Reconstruction of patient-specific 3D bone surface from 2D calibrated fluoroscopic images and a point distribution model is discussed. We present a 2D/3D reconstruction scheme combining statistical extrapolation and regularized shape deformation with an iterative image-to-model correspondence establishing algorithm, and show its application to reconstruct the surface of proximal femur. The image-to-model correspondence is established using a non-rigid 2D point matching process, which iteratively uses a symmetric injective nearest-neighbor mapping operator and 2D thin-plate splines based deformation to find a fraction of best matched 2D point pairs between features detected from the fluoroscopic images and those extracted from the 3D model. The obtained 2D point pairs are then used to set up a set of 3D point pairs such that we turn a 2D/3D reconstruction problem to a 3D/3D one. We designed and conducted experiments on 11 cadaveric femurs to validate the present reconstruction scheme. An average mean reconstruction error of 1.2 mm was found when two fluoroscopic images were used for each bone. It decreased to 1.0 mm when three fluoroscopic images were used.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Taking the South African experience as an example, this article considers the interpretive benefits to be reaped from having access to bi- and multilingual versions of a statutory text. The discussion takes place against the backdrop of a history of statutory bi- and multilingualism in the said jurisdiction as well as, at present, constitutional guarantees of language rights and the “parity of esteem” of eleven official languages. It is argued that, if invoked with due discretion and in a non-rigid way, statutory multilingualism can be a boon to statutory and constitutional interpretation. The South African courts – whose traditional approach to statutory inter-pretation has tended to be literalist, formalistic and formulaic – are, generally speaking, to be commended for their supple use of bilingualism as an aid to interpretation over the years. The advent of constitutional multilingualism and the (potential) availability of statutory texts (and the Constitution) in more than two languages, have moreover created conditions conducive to the further development and refinement of reliance on multilingualism in statutory and constitutional interpretation – certain challenges notwithstanding.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND Accurate needle placement is crucial for the success of percutaneous radiological needle interventions. We compared three guiding methods using an optical-based navigation system: freehand, using a stereotactic aiming device and active depth control, and using a stereotactic aiming device and passive depth control. METHODS For each method, 25 punctures were performed on a non-rigid phantom. Five 1 mm metal screws were used as targets. Time requirements were recorded, and target positioning errors (TPE) were measured on control scans as the distance between needle tip and target. RESULTS Time requirements were reduced using the aiming device and passive depth control. The Euclidian TPE was similar for each method (4.6 ± 1.2-4.9 ± 1.7 mm). However, the lateral component was significantly lower when an aiming device was used (2.3 ± 1.3-2.8 ± 1.6 mm with an aiming device vs 4.2 ± 2.0 mm without). DISCUSSION Using an aiming device may increase the lateral accuracy of navigated needle insertion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Standard stereotaxic reference systems play a key role in human brain studies. Stereotaxic coordinate systems have also been developed for experimental animals including non-human primates, dogs, and rodents. However, they are lacking for other species being relevant in experimental neuroscience including sheep. Here, we present a spatial, unbiased ovine brain template with tissue probability maps (TPM) that offer a detailed stereotaxic reference frame for anatomical features and localization of brain areas, thereby enabling inter-individual and cross-study comparability. Three-dimensional data sets from healthy adult Merino sheep (Ovis orientalis aries, 12 ewes and 26 neutered rams) were acquired on a 1.5 T Philips MRI using a T1w sequence. Data were averaged by linear and non-linear registration algorithms. Moreover, animals were subjected to detailed brain volume analysis including examinations with respect to body weight (BW), age, and sex. The created T1w brain template provides an appropriate population-averaged ovine brain anatomy in a spatial standard coordinate system. Additionally, TPM for gray (GM) and white (WM) matter as well as cerebrospinal fluid (CSF) classification enabled automatic prior-based tissue segmentation using statistical parametric mapping (SPM). Overall, a positive correlation of GM volume and BW explained about 15% of the variance of GM while a positive correlation between WM and age was found. Absolute tissue volume differences were not detected, indeed ewes showed significantly more GM per bodyweight as compared to neutered rams. The created framework including spatial brain template and TPM represent a useful tool for unbiased automatic image preprocessing and morphological characterization in sheep. Therefore, the reported results may serve as a starting point for further experimental and/or translational research aiming at in vivo analysis in this species.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Comunicación presentada en la VI Conferencia de la Asociación Española para la Inteligencia Artificial (CAEPIA'95), Alicante, 15-17 noviembre 1995.